메뉴 건너뛰기




Volumn 70, Issue 11, 2015, Pages 1230-1234

Accuracy of conventional digital palpation and ultrasound of the cricothyroid membrane in obese women in labour

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANATOMIC LANDMARK; ARTICLE; BODY MASS; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; CONVENTIONAL DIGITAL PALPATION; CRICOID; CRICOTHYROID MEMBRANE; ECHOGRAPHY; FEMALE; GESTATIONAL AGE; HUMAN; LABOR; MATERNAL OBESITY; NECK CIRCUMFERENCE; PALPATION; REAL TIME ULTRASOUND SCANNER; THYROID GLAND; TRACHEOTOMY; ULTRAVIOLET RADIATION; ANATOMY AND HISTOLOGY; COMPLICATION; CONTROLLED CLINICAL TRIAL; ENDOTRACHEAL INTUBATION; LARYNX CARTILAGE; MORPHOMETRICS; OBESITY; PREGNANCY; PREGNANCY COMPLICATION; PROCEDURES; REPRODUCIBILITY; STATISTICS AND NUMERICAL DATA;

EID: 84943585585     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.13167     Document Type: Article
Times cited : (80)

References (20)
  • 1
    • 34248332579 scopus 로고    scopus 로고
    • Trends in pre-pregnancy obesity in nine states, 1993-2003
    • Kim SY, Dietz PM, England L, et al., Trends in pre-pregnancy obesity in nine states, 1993-2003. Obesity 2007; 15: 986-93.
    • (2007) Obesity , vol.15 , pp. 986-993
    • Kim, S.Y.1    Dietz, P.M.2    England, L.3
  • 2
    • 2342438720 scopus 로고    scopus 로고
    • Obesity, obstetric complications and cesarean delivery rate - A population based screening study
    • Weiss JL, Malone FD, Emig D, et al., Obesity, obstetric complications and cesarean delivery rate-A population based screening study. American Journal of Obstetrics and Gynecology 2004; 190: 1091-7.
    • (2004) American Journal of Obstetrics and Gynecology , vol.190 , pp. 1091-1097
    • Weiss, J.L.1    Malone, F.D.2    Emig, D.3
  • 3
    • 84871228622 scopus 로고    scopus 로고
    • Failed tracheal intubation in obstetric anaesthesia: 2 yr national case-control study in the UK
    • Quinn AC, Milne D, Columb M, Gorton H, Knight M,. Failed tracheal intubation in obstetric anaesthesia: 2 yr national case-control study in the UK. British Journal of Anaesthesia 2013; 110: 74-80.
    • (2013) British Journal of Anaesthesia , vol.110 , pp. 74-80
    • Quinn, A.C.1    Milne, D.2    Columb, M.3    Gorton, H.4    Knight, M.5
  • 4
    • 81155146129 scopus 로고    scopus 로고
    • Equipment and strategies for emergency tracheal access in the adult patient
    • Hamaekers AE, Henderson JJ,. Equipment and strategies for emergency tracheal access in the adult patient. Anaesthesia 2011; 66: 65-80.
    • (2011) Anaesthesia , vol.66 , pp. 65-80
    • Hamaekers, A.E.1    Henderson, J.J.2
  • 5
    • 80054036720 scopus 로고    scopus 로고
    • Ultrasonography in the management of the airway
    • Kristensen MS,. Ultrasonography in the management of the airway. Acta Anaesthesiologica Scandinavica 2011; 55: 1155-73.
    • (2011) Acta Anaesthesiologica Scandinavica , vol.55 , pp. 1155-1173
    • Kristensen, M.S.1
  • 6
    • 52949117209 scopus 로고    scopus 로고
    • Bedside sonography by emergency physicians for the rapid identification of landmarks relevant to cricothyroidotomy
    • Nicholls SE, Sweeney TW, Ferre RM, Strout TD,. Bedside sonography by emergency physicians for the rapid identification of landmarks relevant to cricothyroidotomy. American Journal of Emergency Medicine 2008; 26: 852-6.
    • (2008) American Journal of Emergency Medicine , vol.26 , pp. 852-856
    • Nicholls, S.E.1    Sweeney, T.W.2    Ferre, R.M.3    Strout, T.D.4
  • 7
    • 84860305704 scopus 로고    scopus 로고
    • Accuracy of identification of the cricothyroid membrane in female patients using palpation: An observational study
    • Aslani A, Ng SC, Hurley M, McCarthy KF, McNicholas M, McCaul CL,. Accuracy of identification of the cricothyroid membrane in female patients using palpation: an observational study. Anesthesia and Analgesia 2012; 114: 987-92.
    • (2012) Anesthesia and Analgesia , vol.114 , pp. 987-992
    • Aslani, A.1    Ng, S.C.2    Hurley, M.3    McCarthy, K.F.4    McNicholas, M.5    McCaul, C.L.6
  • 9
    • 84939956614 scopus 로고    scopus 로고
    • Accuracy of identifying the cricothyroid membrane by anesthesia trainees and staff in a Canadian institution
    • Lamb A, Zhang J, Hung O, et al., Accuracy of identifying the cricothyroid membrane by anesthesia trainees and staff in a Canadian institution. Canadian Journal of Anesthesia 2015; 62: 495-503.
    • (2015) Canadian Journal of Anesthesia , vol.62 , pp. 495-503
    • Lamb, A.1    Zhang, J.2    Hung, O.3
  • 10
    • 79954538887 scopus 로고    scopus 로고
    • Major complications of airway management in the UK: Results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
    • Fourth National Audit Project.
    • Cook TM, Woodall N, Frerk C,; Fourth National Audit Project. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. British Journal of Anaesthesia 2011; 106: 617-31.
    • (2011) British Journal of Anaesthesia , vol.106 , pp. 617-631
    • Cook, T.M.1    Woodall, N.2    Frerk, C.3
  • 11
    • 84916613169 scopus 로고    scopus 로고
    • MBRRACE-UK-the new home for the Confidential Enquiries into Maternal Deaths-reports for the first time
    • Bamber JH, Kinsella SM,. MBRRACE-UK-the new home for the Confidential Enquiries into Maternal Deaths-reports for the first time. Anaesthesia 2015; 70: 5-9.
    • (2015) Anaesthesia , vol.70 , pp. 5-9
    • Bamber, J.H.1    Kinsella, S.M.2
  • 13
    • 0242637296 scopus 로고    scopus 로고
    • Prediction of difficult laryngoscopy in obese patients by ultrasound quantification of anterior neck soft tissue
    • Ezri T, Gewürtz G, Sessler DI, et al., Prediction of difficult laryngoscopy in obese patients by ultrasound quantification of anterior neck soft tissue. Anaesthesia 2003; 58: 1111-4.
    • (2003) Anaesthesia , vol.58 , pp. 1111-1114
    • Ezri, T.1    Gewürtz, G.2    Sessler, D.I.3
  • 14
    • 0029738593 scopus 로고    scopus 로고
    • The dimensions and vascular anatomy of the cricothyroid membrane: Relevance to emergent surgical airway access
    • Dover K, Howdieshell TR, Colborn GL,. The dimensions and vascular anatomy of the cricothyroid membrane: relevance to emergent surgical airway access. Clinical Anatomy 1996; 9: 291-5.
    • (1996) Clinical Anatomy , vol.9 , pp. 291-295
    • Dover, K.1    Howdieshell, T.R.2    Colborn, G.L.3
  • 16
    • 84900384458 scopus 로고    scopus 로고
    • Ultrasonographic identification of the cricothyroid membrane
    • Teoh WH, Kristensen MS,. Ultrasonographic identification of the cricothyroid membrane. Anaesthesia 2014; 69: 649-650.
    • (2014) Anaesthesia , vol.69 , pp. 649-650
    • Teoh, W.H.1    Kristensen, M.S.2
  • 17
    • 84872861140 scopus 로고    scopus 로고
    • American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice guidelines for management of the difficult airway: An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway
    • Apfelbaum JL, Hagberg CA, Caplan RA, et al., American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Practice guidelines for management of the difficult airway: an updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway. Anesthesiology 2013; 118: 251-70.
    • (2013) Anesthesiology , vol.118 , pp. 251-270
    • Apfelbaum, J.L.1    Hagberg, C.A.2    Caplan, R.A.3
  • 18
    • 84887420838 scopus 로고    scopus 로고
    • The difficult airway with recommendations for management-part 2-the anticipated difficult airway. Canadian Airway Focus Group
    • Law JA, Broemling N, Cooper RM, et al., The difficult airway with recommendations for management-part 2-the anticipated difficult airway. Canadian Airway Focus Group. Canadian Journal of Anesthesia 2013; 60: 1119-38.
    • (2013) Canadian Journal of Anesthesia , vol.60 , pp. 1119-1138
    • Law, J.A.1    Broemling, N.2    Cooper, R.M.3
  • 19
    • 2142715915 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous dilatational tracheostomy with laryngeal mask airway control in a morbidly obese patient
    • Sustic A, Zupan Z, Antoncic I,. Ultrasound-guided percutaneous dilatational tracheostomy with laryngeal mask airway control in a morbidly obese patient. Journal of Clinical Anesthesia 2004; 16: 121-3.
    • (2004) Journal of Clinical Anesthesia , vol.16 , pp. 121-123
    • Sustic, A.1    Zupan, Z.2    Antoncic, I.3
  • 20
    • 84893455434 scopus 로고    scopus 로고
    • Usefulness of ultrasound pre-scanning for cricothyroid membrane puncture in a patient with rupture of a pseudoaneurysm
    • Owada G, Inagawa G, Nakamura K, Kariya T, Goto T,. Usefulness of ultrasound pre-scanning for cricothyroid membrane puncture in a patient with rupture of a pseudoaneurysm. Masui 2014; 63: 77-80.
    • (2014) Masui , vol.63 , pp. 77-80
    • Owada, G.1    Inagawa, G.2    Nakamura, K.3    Kariya, T.4    Goto, T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.