메뉴 건너뛰기




Volumn 70, Issue 11, 2015, Pages 1281-1285

A comparison of the ease of tracheal intubation using a McGrath MAC® laryngoscope and a standard Macintosh laryngoscope

Author keywords

[No Author keywords available]

Indexed keywords

ABDUCTION; ADULT; BODY MASS; CONFERENCE PAPER; CONTROLLED STUDY; DEVICE COMPARISON; ENDOTRACHEAL INTUBATION; FEMALE; HUMAN; INTUBATION DIFFICULTY SCORES; LARYNGOSCOPE; MAJOR CLINICAL STUDY; MALE; MEDICAL ASSESSMENT; OPERATOR; VIDEOLARYNGOSCOPE; VOCAL CORD; COMPARATIVE STUDY; DEVICES; EQUIPMENT DESIGN; LARYNGOSCOPY; MIDDLE AGED; VIDEORECORDING;

EID: 84943570021     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.13209     Document Type: Conference Paper
Times cited : (40)

References (12)
  • 2
    • 81155125277 scopus 로고    scopus 로고
    • Evidence for benefit vs novelty in new intubation equipment
    • Kristensen SM, Behringer EC,. Evidence for benefit vs novelty in new intubation equipment. Anaesthesia 2011; 66 (Suppl. 2): 57-64.
    • (2011) Anaesthesia , vol.66 , pp. 57-64
    • Kristensen, S.M.1    Behringer, E.C.2
  • 3
    • 79960345145 scopus 로고    scopus 로고
    • The Difficult Airway Society 'ADEPT' Guidance on selecting airway devices: The basis of a strategy for equipment evaluation
    • Pandit JJ, Popat MT, Cook TM, et al., The Difficult Airway Society 'ADEPT' Guidance on selecting airway devices: the basis of a strategy for equipment evaluation. Anaesthesia 2011; 66: 726-37.
    • (2011) Anaesthesia , vol.66 , pp. 726-737
    • Pandit, J.J.1    Popat, M.T.2    Cook, T.M.3
  • 4
    • 1842746752 scopus 로고    scopus 로고
    • Airway Difficulty Score (ADS); A new score to predict difficulty in airway management
    • Jannsens M, Lamy M,. Airway Difficulty Score (ADS); a new score to predict difficulty in airway management. European Journal of Anaesthesiology 2000; 17 (Suppl): 35.
    • (2000) European Journal of Anaesthesiology , vol.17 , pp. 35
    • Jannsens, M.1    Lamy, M.2
  • 6
    • 0031469105 scopus 로고    scopus 로고
    • The intubation difficulty scale (IDS): Proposal and evaluation of a new score characterising the complexity of endotracheal intubation
    • Adnet F, Borron SW, Racine SX, et al., The intubation difficulty scale (IDS): proposal and evaluation of a new score characterising the complexity of endotracheal intubation. Anesthesiology 1997; 87: 1290-7.
    • (1997) Anesthesiology , vol.87 , pp. 1290-1297
    • Adnet, F.1    Borron, S.W.2    Racine, S.X.3
  • 7
    • 33750041338 scopus 로고    scopus 로고
    • A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial
    • Maharaj CH, O'Croinin D, Curley G, et al., A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: a randomised, controlled clinical trial. Anaesthesia 2006; 61: 1093-99.
    • (2006) Anaesthesia , vol.61 , pp. 1093-1099
    • Maharaj, C.H.1    O'Croinin, D.2    Curley, G.3
  • 8
    • 0037223845 scopus 로고    scopus 로고
    • Laryngoscopic intubation: Learning and performance
    • Mulcaster JT, Mills J, Hung OR, et al., Laryngoscopic intubation: learning and performance. Anesthesiology 2003; 98: 23-7.
    • (2003) Anesthesiology , vol.98 , pp. 23-27
    • Mulcaster, J.T.1    Mills, J.2    Hung, O.R.3
  • 9
    • 84943547187 scopus 로고    scopus 로고
    • Comparison of Macintosh and McGrath in a tertiary head and neck centre
    • Capek AL, Thomson S, Young SP, Cunningham V,. Comparison of Macintosh and McGrath in a tertiary head and neck centre. Anaesthesia 2013; 68: 883-6.
    • (2013) Anaesthesia , vol.68 , pp. 883-886
    • Capek, A.L.1    Thomson, S.2    Young, S.P.3    Cunningham, V.4
  • 10
    • 70350702956 scopus 로고    scopus 로고
    • A comparison of three videolaryngoscopes: The Macintosh blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients
    • Massen R, Lee R, Hermans B, et al., A comparison of three videolaryngoscopes: the Macintosh blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anaesthesia and Analgesia 2009; 109: 1560-5.
    • (2009) Anaesthesia and Analgesia , vol.109 , pp. 1560-1565
    • Massen, R.1    Lee, R.2    Hermans, B.3
  • 11
    • 0034752378 scopus 로고    scopus 로고
    • A case of tracheal injury after emergent intubation: A review of the literature and causalities
    • Chen EH, Logman ZM, Glass PSA, Bilfinger TV,. A case of tracheal injury after emergent intubation: a review of the literature and causalities. Anaesthesia and Analgesia 2001; 93: 1270-1.
    • (2001) Anaesthesia and Analgesia , vol.93 , pp. 1270-1271
    • Chen, E.H.1    Logman, Z.M.2    Glass, P.S.A.3    Bilfinger, T.V.4
  • 12
    • 84894317437 scopus 로고    scopus 로고
    • The traffic light bougie: A study of a novel safety modification
    • Paul A, Gibson A, Robinson ODG, Koch J,. The traffic light bougie: a study of a novel safety modification. Anaesthesia 2014; 69: 214-8.
    • (2014) Anaesthesia , vol.69 , pp. 214-218
    • Paul, A.1    Gibson, A.2    Robinson, O.D.G.3    Koch, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.