Volumn 66, Issue 12, 2015, Pages 1350-1360

Pulmonary Vein Isolation Using the Visually Guided Laser Balloon A Prospective, Multicenter, and Randomized Comparison to Standard Radiofrequency Ablation

Author keywords

antiarrhythmic drug; atrial fibrillation; catheter ablation; paroxysmal

Indexed keywords

DABIGATRAN; RIVAROXABAN; WARFARIN;

EID: 84942512070     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2015.07.036     Document Type: Article
Times cited : (169)

References (18)
  • 1
    • 84865278119 scopus 로고    scopus 로고
    • 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation
    • H. Calkins, K.H. Kuck, R. Cappato, and et al. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation Heart Rhythm 9 2012 632 696.e21
    • (2012) Heart Rhythm , vol.9 , pp. 632-696e21
    • Calkins, H.1    Kuck, K.H.2    Cappato, R.3
  • 2
    • 78650714879 scopus 로고    scopus 로고
    • Long-term results of catheter ablation in paroxysmal atrial fibrillation: Lessons from a 5-year follow-up
    • F. Ouyang, R. Tilz, J. Chun, and et al. Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up Circulation 122 2010 2368 2377
    • (2010) Circulation , vol.122 , pp. 2368-2377
    • Ouyang, F.1    Tilz, R.2    Chun, J.3
  • 3
    • 78650898232 scopus 로고    scopus 로고
    • Catheter ablation for atrial fibrillation: Are results maintained at 5 years of follow-up?
    • R. Weerasooriya, P. Khairy, J. Litalien, and et al. Catheter ablation for atrial fibrillation: are results maintained at 5 years of follow-up? J Am Coll Cardiol 57 2011 160 166
    • (2011) J Am Coll Cardiol , vol.57 , pp. 160-166
    • Weerasooriya, R.1    Khairy, P.2    Litalien, J.3
  • 4
    • 84876283750 scopus 로고    scopus 로고
    • Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: First results of the North American Arctic Front (STOP AF) pivotal trial
    • D.L. Packer, R.C. Kowal, K.R. Wheelan, and et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial J Am Coll Cardiol 61 2013 1713 1723
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1713-1723
    • Packer, D.L.1    Kowal, R.C.2    Wheelan, K.R.3
  • 5
    • 70349437458 scopus 로고    scopus 로고
    • Feasibility of the radiofrequency hot balloon catheter for isolation of the posterior left atrium and pulmonary veins for the treatment of atrial fibrillation
    • H. Sohara, H. Takeda, H. Ueno, T. Oda, and S. Satake Feasibility of the radiofrequency hot balloon catheter for isolation of the posterior left atrium and pulmonary veins for the treatment of atrial fibrillation Circ Arrhythm Electrophysiol 2 2009 225 232
    • (2009) Circ Arrhythm Electrophysiol , vol.2 , pp. 225-232
    • Sohara, H.1    Takeda, H.2    Ueno, H.3    Oda, T.4    Satake, S.5
  • 6
    • 84883011022 scopus 로고    scopus 로고
    • Pulmonary vein isolation using a visually guided laser balloon catheter: The first 200-patient multicenter clinical experience
    • S.R. Dukkipati, K.H. Kuck, P. Neuzil, and et al. Pulmonary vein isolation using a visually guided laser balloon catheter: the first 200-patient multicenter clinical experience Circ Arrhythm Electrophysiol 6 2013 467 472
    • (2013) Circ Arrhythm Electrophysiol , vol.6 , pp. 467-472
    • Dukkipati, S.R.1    Kuck, K.H.2    Neuzil, P.3
  • 7
    • 84871953765 scopus 로고    scopus 로고
    • Acute and long-term clinical outcome after endoscopic pulmonary vein isolation: Results from the first prospective, multicenter study
    • A. Metzner, E. Wissner, B. Schmidt, and et al. Acute and long-term clinical outcome after endoscopic pulmonary vein isolation: results from the first prospective, multicenter study J Cardiovasc Electrophysiol 24 2013 7 13
    • (2013) J Cardiovasc Electrophysiol , vol.24 , pp. 7-13
    • Metzner, A.1    Wissner, E.2    Schmidt, B.3
  • 8
    • 84861333040 scopus 로고    scopus 로고
    • The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies
    • S.R. Dukkipati, P. Neuzil, J. Kautzner, and et al. The durability of pulmonary vein isolation using the visually guided laser balloon catheter: multicenter results of pulmonary vein remapping studies Heart Rhythm 9 2012 919 925
    • (2012) Heart Rhythm , vol.9 , pp. 919-925
    • Dukkipati, S.R.1    Neuzil, P.2    Kautzner, J.3
  • 9
    • 84925515688 scopus 로고    scopus 로고
    • Visually guided laser ablation: A single-centre long-term experience
    • L. Sediva, J. Petru, J. Skoda, and et al. Visually guided laser ablation: a single-centre long-term experience Europace 16 2014 1746 1751
    • (2014) Europace , vol.16 , pp. 1746-1751
    • Sediva, L.1    Petru, J.2    Skoda, J.3
  • 10
    • 84883748037 scopus 로고    scopus 로고
    • Comparison of balloon catheter ablation technologies for pulmonary vein isolation: The laser versus cryo study
    • S. Bordignon, K.R. Chun, M. Gunawardene, and et al. Comparison of balloon catheter ablation technologies for pulmonary vein isolation: the laser versus cryo study J Cardiovasc Electrophysiol 24 2013 987 994
    • (2013) J Cardiovasc Electrophysiol , vol.24 , pp. 987-994
    • Bordignon, S.1    Chun, K.R.2    Gunawardene, M.3
  • 11
    • 84905983949 scopus 로고    scopus 로고
    • Paroxysmal AF catheter ablation with a contact force sensing catheter: Results of the prospective, multicenter SMART-AF trial
    • A. Natale, V.Y. Reddy, G. Monir, and et al. Paroxysmal AF catheter ablation with a contact force sensing catheter: results of the prospective, multicenter SMART-AF trial J Am Coll Cardiol 64 2014 647 656
    • (2014) J Am Coll Cardiol , vol.64 , pp. 647-656
    • Natale, A.1    Reddy, V.Y.2    Monir, G.3
  • 12
    • 84855489815 scopus 로고    scopus 로고
    • Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies
    • J.G. Andrade, P. Khairy, P.G. Guerra, and et al. Efficacy and safety of cryoballoon ablation for atrial fibrillation: a systematic review of published studies Heart Rhythm 8 2011 1444 1451
    • (2011) Heart Rhythm , vol.8 , pp. 1444-1451
    • Andrade, J.G.1    Khairy, P.2    Guerra, P.G.3
  • 13
    • 84924352457 scopus 로고    scopus 로고
    • Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon
    • K. Aytemir, K.M. Gurses, M.U. Yalcin, and et al. Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon Europace 17 2014 379 387
    • (2014) Europace , vol.17 , pp. 379-387
    • Aytemir, K.1    Gurses, K.M.2    Yalcin, M.U.3
  • 14
    • 84894533867 scopus 로고    scopus 로고
    • Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation
    • R.P. Martins, D. Hamon, O. Cesari, and et al. Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation Heart Rhythm 11 2014 386 393
    • (2014) Heart Rhythm , vol.11 , pp. 386-393
    • Martins, R.P.1    Hamon, D.2    Cesari, O.3
  • 15
    • 75749090779 scopus 로고    scopus 로고
    • Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: A randomized controlled trial
    • D.J. Wilber, C. Pappone, P. Neuzil, and et al. Comparison of antiarrhythmic drug therapy and radiofrequency catheter ablation in patients with paroxysmal atrial fibrillation: a randomized controlled trial JAMA 303 2010 333 340
    • (2010) JAMA , vol.303 , pp. 333-340
    • Wilber, D.J.1    Pappone, C.2    Neuzil, P.3
  • 16
    • 77649308976 scopus 로고    scopus 로고
    • Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
    • R. Cappato, H. Calkins, S.A. Chen, and et al. Updated worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation Circ Arrhythm Electrophysiol 3 2010 32 38
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 32-38
    • Cappato, R.1    Calkins, H.2    Chen, S.A.3
  • 17
    • 84926343871 scopus 로고    scopus 로고
    • How to learn pulmonary vein isolation with a novel ablation device: Learning curve effects using the endoscopic ablation system
    • L. Perrotta, S. Bordignon, D. Dugo, A. Furnkranz, K.J. Chun, and B. Schmidt How to learn pulmonary vein isolation with a novel ablation device: learning curve effects using the endoscopic ablation system J Cardiovasc Electrophysiol 25 2014 1293 1298
    • (2014) J Cardiovasc Electrophysiol , vol.25 , pp. 1293-1298
    • Perrotta, L.1    Bordignon, S.2    Dugo, D.3    Furnkranz, A.4    Chun, K.J.5    Schmidt, B.6
  • 18
    • 84874855728 scopus 로고    scopus 로고
    • Energy titration strategies with the endoscopic ablation system: Lessons from the high-dose vs. Low-dose laser ablation study
    • S. Bordignon, K.R. Chun, M. Gunawardene, and et al. Energy titration strategies with the endoscopic ablation system: lessons from the high-dose vs. low-dose laser ablation study Europace 15 2013 685 689
    • (2013) Europace , vol.15 , pp. 685-689
    • Bordignon, S.1    Chun, K.R.2    Gunawardene, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.