메뉴 건너뛰기




Volumn 9, Issue 6, 2012, Pages 919-925

The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies

Author keywords

Ablation; Atrial fibrillation; Endoscopic visualization; Laser; Paroxysmal; Pulmonary veins

Indexed keywords

ADULT; AGED; ARTICLE; BALLOON CATHETER; CATHETER ABLATION; FEMALE; FOLLOW UP; GROIN HEMATOMA; HEART ATRIUM FIBRILLATION; HEART TAMPONADE; HUMAN; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; NERVE INJURY; PRIORITY JOURNAL; PULMONARY VEIN; PULMONARY VEIN ISOLATION; TREATMENT OUTCOME; VISUALLY GUIDED LASER ABLATION CATHETER;

EID: 84861333040     PISSN: 15475271     EISSN: 15563871     Source Type: Journal    
DOI: 10.1016/j.hrthm.2012.01.019     Document Type: Article
Times cited : (130)

References (24)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • M. Haissaguerre, P. Jais, D.C. Shah Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins N Engl J Med 339 1998 659 666
    • (1998) N Engl J Med , vol.339 , pp. 659-666
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 2
    • 0033517860 scopus 로고    scopus 로고
    • Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: Electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation
    • S.A. Chen, M.H. Hsieh, C.T. Tai Initiation of atrial fibrillation by ectopic beats originating from the pulmonary veins: electrophysiological characteristics, pharmacological responses, and effects of radiofrequency ablation Circulation 100 1999 1879 1886
    • (1999) Circulation , vol.100 , pp. 1879-1886
    • Chen, S.A.1    Hsieh, M.H.2    Tai, C.T.3
  • 3
    • 0343729318 scopus 로고    scopus 로고
    • Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    • M. Haissaguerre, P. Jais, D.C. Shah Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci Circulation 101 2000 1409 1417
    • (2000) Circulation , vol.101 , pp. 1409-1417
    • Haissaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 4
    • 0037022841 scopus 로고    scopus 로고
    • Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    • H. Oral, B.P. Knight, H. Tada Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation Circulation 105 2002 1077 1081
    • (2002) Circulation , vol.105 , pp. 1077-1081
    • Oral, H.1    Knight, B.P.2    Tada, H.3
  • 5
    • 78649349439 scopus 로고    scopus 로고
    • Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome
    • S. Willems, D. Steven, H. Servatius Persistence of pulmonary vein isolation after robotic remote-navigated ablation for atrial fibrillation and its relation to clinical outcome J Cardiovasc Electrophysiol 21 2010 1079 1084
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 1079-1084
    • Willems, S.1    Steven, D.2    Servatius, H.3
  • 6
    • 1642398327 scopus 로고    scopus 로고
    • Resumption of electrical conduction in previously isolated pulmonary veins: Rationale for a different strategy?
    • K. Nanthakumar, V.J. Plumb, A.E. Epstein, G.D. Veenhuyzen, D. Link, G.N. Kay Resumption of electrical conduction in previously isolated pulmonary veins: rationale for a different strategy? Circulation 109 2004 1226 1229
    • (2004) Circulation , vol.109 , pp. 1226-1229
    • Nanthakumar, K.1    Plumb, V.J.2    Epstein, A.E.3    Veenhuyzen, G.D.4    Link, D.5    Kay, G.N.6
  • 7
    • 23244456677 scopus 로고    scopus 로고
    • Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction
    • A. Verma, F. Kilicaslan, E. Pisano Response of atrial fibrillation to pulmonary vein antrum isolation is directly related to resumption and delay of pulmonary vein conduction Circulation 112 2005 627 635
    • (2005) Circulation , vol.112 , pp. 627-635
    • Verma, A.1    Kilicaslan, F.2    Pisano, E.3
  • 8
    • 78650898232 scopus 로고    scopus 로고
    • Catheter ablation for atrial fibrillation: Are results maintained at 5 years of follow-up?
    • R. Weerasooriya, P. Khairy, J. Litalien Catheter ablation for atrial fibrillation: are results maintained at 5 years of follow-up? J Am Coll Cardiol 57 2011 160 166
    • (2011) J Am Coll Cardiol , vol.57 , pp. 160-166
    • Weerasooriya, R.1    Khairy, P.2    Litalien, J.3
  • 9
    • 78650714879 scopus 로고    scopus 로고
    • Long-term results of catheter ablation in paroxysmal atrial fibrillation: Lessons from a 5-year follow-up
    • F. Ouyang, R. Tilz, J. Chun Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up Circulation 122 2010 2368 2377
    • (2010) Circulation , vol.122 , pp. 2368-2377
    • Ouyang, F.1    Tilz, R.2    Chun, J.3
  • 10
    • 77954672429 scopus 로고    scopus 로고
    • Long-term outcome after successful catheter ablation of atrial fibrillation
    • W.S. Tzou, F.E. Marchlinski, E.S. Zado Long-term outcome after successful catheter ablation of atrial fibrillation Circ Arrhythm Electrophysiol 3 2010 237 242
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 237-242
    • Tzou, W.S.1    Marchlinski, F.E.2    Zado, E.S.3
  • 11
    • 67651159162 scopus 로고    scopus 로고
    • Five-year outcomes after segmental pulmonary vein isolation for paroxysmal atrial fibrillation
    • N. Sawhney, R. Anousheh, W.C. Chen, S. Narayan, G.K. Feld Five-year outcomes after segmental pulmonary vein isolation for paroxysmal atrial fibrillation Am J Cardiol 104 2009 366 372
    • (2009) Am J Cardiol , vol.104 , pp. 366-372
    • Sawhney, N.1    Anousheh, R.2    Chen, W.C.3    Narayan, S.4    Feld, G.K.5
  • 12
    • 74649083503 scopus 로고    scopus 로고
    • Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: Results from a multicenter study
    • M. Bhargava, L. Di Biase, P. Mohanty Impact of type of atrial fibrillation and repeat catheter ablation on long-term freedom from atrial fibrillation: results from a multicenter study Heart Rhythm 6 2009 1403 1412
    • (2009) Heart Rhythm , vol.6 , pp. 1403-1412
    • Bhargava, M.1    Di Biase, L.2    Mohanty, P.3
  • 13
    • 67651121538 scopus 로고    scopus 로고
    • Visually-guided balloon catheter ablation of atrial fibrillation: Experimental feasibility and first-in-human multicenter clinical outcome
    • V.Y. Reddy, P. Neuzil, S. Themistoclakis Visually-guided balloon catheter ablation of atrial fibrillation: experimental feasibility and first-in-human multicenter clinical outcome Circulation 120 2009 12 20
    • (2009) Circulation , vol.120 , pp. 12-20
    • Reddy, V.Y.1    Neuzil, P.2    Themistoclakis, S.3
  • 14
    • 77954677669 scopus 로고    scopus 로고
    • Visual balloon-guided point-by-point ablation: Reliable, reproducible, and persistent pulmonary vein isolation
    • S.R. Dukkipati, P. Neuzil, J. Skoda Visual balloon-guided point-by-point ablation: reliable, reproducible, and persistent pulmonary vein isolation Circ Arrhythm Electrophysiol 3 2010 266 273
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 266-273
    • Dukkipati, S.R.1    Neuzil, P.2    Skoda, J.3
  • 15
    • 78049513556 scopus 로고    scopus 로고
    • Feasibility of circumferential pulmonary vein isolation using a novel endoscopic ablation system
    • B. Schmidt, A. Metzner, K.R. Chun Feasibility of circumferential pulmonary vein isolation using a novel endoscopic ablation system Circ Arrhythm Electrophysiol 3 2010 481 488
    • (2010) Circ Arrhythm Electrophysiol , vol.3 , pp. 481-488
    • Schmidt, B.1    Metzner, A.2    Chun, K.R.3
  • 16
    • 77954318686 scopus 로고    scopus 로고
    • Pulmonary vein isolation using a compliant endoscopic laser balloon ablation system in a swine model
    • E.P. Gerstenfeld, J. Michele Pulmonary vein isolation using a compliant endoscopic laser balloon ablation system in a swine model J Interv Card Electrophysiol 29 2010 1 9
    • (2010) J Interv Card Electrophysiol , vol.29 , pp. 1-9
    • Gerstenfeld, E.P.1    Michele, J.2
  • 17
    • 79960023028 scopus 로고    scopus 로고
    • One-year clinical outcome after pulmonary vein isolation using the novel Endoscopic Ablation System in patients with paroxysmal atrial fibrillation
    • A. Metzner, B. Schmidt, A. Fuernkranz One-year clinical outcome after pulmonary vein isolation using the novel Endoscopic Ablation System in patients with paroxysmal atrial fibrillation Heart Rhythm 8 2011 988 993
    • (2011) Heart Rhythm , vol.8 , pp. 988-993
    • Metzner, A.1    Schmidt, B.2    Fuernkranz, A.3
  • 18
    • 34250697881 scopus 로고    scopus 로고
    • Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study
    • T. Arentz, R. Weber, G. Bürkle Small or large isolation areas around the pulmonary veins for the treatment of atrial fibrillation? Results from a prospective randomized study Circulation 115 2007 3057 3063
    • (2007) Circulation , vol.115 , pp. 3057-3063
    • Arentz, T.1    Weber, R.2    Bürkle, G.3
  • 19
    • 39649105652 scopus 로고    scopus 로고
    • Balloon catheter ablation to treat paroxysmal atrial fibrillation: What is the level of pulmonary vein isolation?
    • V.Y. Reddy, P. Neuzil, A. d'Avila Balloon catheter ablation to treat paroxysmal atrial fibrillation: what is the level of pulmonary vein isolation? Heart Rhythm 5 2008 353 360
    • (2008) Heart Rhythm , vol.5 , pp. 353-360
    • Reddy, V.Y.1    Neuzil, P.2    D'Avila, A.3
  • 20
    • 0038417550 scopus 로고    scopus 로고
    • Catheter ablation of paroxysmal atrial fibrillation initiated by non-pulmonary vein ectopy
    • W.S. Lin, C.T. Tai, M.H. Hsieh Catheter ablation of paroxysmal atrial fibrillation initiated by non-pulmonary vein ectopy Circulation 107 2003 3176 3183
    • (2003) Circulation , vol.107 , pp. 3176-3183
    • Lin, W.S.1    Tai, C.T.2    Hsieh, M.H.3
  • 22
    • 14644429676 scopus 로고    scopus 로고
    • Catheter ablation of atrial fibrillation originating from the non-pulmonary vein foci
    • S.A. Chen, C.T. Tai Catheter ablation of atrial fibrillation originating from the non-pulmonary vein foci J Cardiovasc Electrophysiol 16 2005 229 232
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 229-232
    • Chen, S.A.1    Tai, C.T.2
  • 23
    • 24944455932 scopus 로고    scopus 로고
    • Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: Implications for catheter ablation
    • S.H. Lee, C.T. Tai, M.H. Hsieh Predictors of non-pulmonary vein ectopic beats initiating paroxysmal atrial fibrillation: implications for catheter ablation J Am Coll Cardiol 46 2005 1054 1059
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1054-1059
    • Lee, S.H.1    Tai, C.T.2    Hsieh, M.H.3
  • 24
    • 78649386400 scopus 로고    scopus 로고
    • Characterization of non-pulmonary vein foci with an EnSite array in patients with paroxysmal atrial fibrillation
    • T. Yamaguchi, T. Tsuchiya, K. Miyamoto, Y. Nagamoto, N. Takahashi Characterization of non-pulmonary vein foci with an EnSite array in patients with paroxysmal atrial fibrillation Europace 12 2010 1698 1706
    • (2010) Europace , vol.12 , pp. 1698-1706
    • Yamaguchi, T.1    Tsuchiya, T.2    Miyamoto, K.3    Nagamoto, Y.4    Takahashi, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.