메뉴 건너뛰기




Volumn 115, Issue 3, 2015, Pages 403-410

Ability of esCCO to track changes in cardiac output

Author keywords

cardiac output; echocardiography; hemodynamics; monitoring

Indexed keywords

NORADRENALIN; SODIUM CHLORIDE; VASOCONSTRICTOR AGENT;

EID: 84942245476     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aev219     Document Type: Article
Times cited : (29)

References (23)
  • 1
    • 23444461703 scopus 로고    scopus 로고
    • Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): A randomised controlled trial
    • Harvey S, Harrison DA, Singer M, et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man): a randomised controlled trial. Lancet 2005; 366: 472-7
    • (2005) Lancet , vol.366 , pp. 472-477
    • Harvey, S.1    Harrison, D.A.2    Singer, M.3
  • 2
    • 0034089262 scopus 로고    scopus 로고
    • Insertion time of the pulmonary artery catheter in critically ill patients
    • Lefrant JY, Muller L, Bruelle P, et al. Insertion time of the pulmonary artery catheter in critically ill patients. Crit Care Med 2000; 28: 355-9
    • (2000) Crit Care Med , vol.28 , pp. 355-359
    • Lefrant, J.Y.1    Muller, L.2    Bruelle, P.3
  • 3
    • 0037413466 scopus 로고    scopus 로고
    • Arandomized controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients
    • Sandham JD, Hull RD, Brant RF, et al.Arandomized, controlled trial of the use of pulmonary-artery catheters in high-risk surgical patients. N Engl J Med 2003; 348: 5-14
    • (2003) N Engl J Med , vol.348 , pp. 5-14
    • Sandham, J.D.1    Hull, R.D.2    Brant, R.F.3
  • 4
    • 84881032084 scopus 로고    scopus 로고
    • The comparison of a novel continuous cardiac output monitor based on pulse wave transit time and echo Doppler during exercise
    • Sugo Y, Sakai T, Terao M, Ukawa T, Ochiai R. The comparison of a novel continuous cardiac output monitor based on pulse wave transit time and echo Doppler during exercise. Conf Proc IEEE Eng Med Biol Soc 2012; 2012: 236-9
    • (2012) Conf Proc IEEE Eng Med Biol Soc , vol.2012 , pp. 236-239
    • Sugo, Y.1    Sakai, T.2    Terao, M.3    Ukawa, T.4    Ochiai, R.5
  • 5
    • 20944444823 scopus 로고    scopus 로고
    • A newnon-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors
    • Ishihara H, Okawa H, Tanabe K, et al. A newnon-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors. J Clin Monit Comput 2004; 18: 313-20
    • (2004) J Clin Monit Comput , vol.18 , pp. 313-320
    • Ishihara, H.1    Okawa, H.2    Tanabe, K.3
  • 6
    • 84869386502 scopus 로고    scopus 로고
    • Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care
    • Bataille B, Bertuit M, Mora M, et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br J Anaesth 2012; 109: 879-86
    • (2012) Br J Anaesth , vol.109 , pp. 879-886
    • Bataille, B.1    Bertuit, M.2    Mora, M.3
  • 7
    • 84877106251 scopus 로고    scopus 로고
    • The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm
    • Ishihara H, Sugo Y, Tsutsui M, et al. The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm. J Clin Monit Comput 2012; 26: 465-71
    • (2012) J Clin Monit Comput , vol.26 , pp. 465-471
    • Ishihara, H.1    Sugo, Y.2    Tsutsui, M.3
  • 8
    • 79957656409 scopus 로고    scopus 로고
    • Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine
    • Monnet X, Letierce A, Hamzaoui O, et al. Arterial pressure allows monitoring the changes in cardiac output induced by volume expansion but not by norepinephrine. Crit Care Med 2011; 39: 1394-9
    • (2011) Crit Care Med , vol.39 , pp. 1394-1399
    • Monnet, X.1    Letierce, A.2    Hamzaoui, O.3
  • 10
    • 33646577770 scopus 로고    scopus 로고
    • Passive leg raising predicts fluid responsiveness in the critically ill
    • Monnet X, Rienzo M, Osman D, et al. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006; 34: 1402-7
    • (2006) Crit Care Med , vol.34 , pp. 1402-1407
    • Monnet, X.1    Rienzo, M.2    Osman, D.3
  • 11
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327: 307-10
    • (1986) Lancet , vol.327 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 12
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 13
    • 78149469431 scopus 로고    scopus 로고
    • A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output
    • Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010; 111: 1180-92
    • (2010) Anesth Analg , vol.111 , pp. 1180-1192
    • Critchley, L.A.1    Lee, A.2    Ho, A.M.3
  • 14
    • 79957736830 scopus 로고    scopus 로고
    • Assessment of trending ability of cardiac output monitors by polar plot methodology
    • Critchley LA, Yang XX, Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J Cardiothorac Vasc Anesth 2011; 25: 536-46
    • (2011) J Cardiothorac Vasc Anesth , vol.25 , pp. 536-546
    • Critchley, L.A.1    Yang, X.X.2    Lee, A.3
  • 15
    • 34347222567 scopus 로고    scopus 로고
    • Hemodynamic monitoring in shock and implications for management. International Consensus Conference Paris France 27-28 April 2006
    • Antonelli M, Levy M, Andrews PJ, et al. Hemodynamic monitoring in shock and implications for management. International Consensus Conference, Paris, France, 27-28 April 2006. Intensive Care Med 2007; 33: 575-90
    • (2007) Intensive Care Med , vol.33 , pp. 575-590
    • Antonelli, M.1    Levy, M.2    Andrews, P.J.3
  • 16
    • 69349089330 scopus 로고    scopus 로고
    • Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: A systematic review of the literature
    • Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009; 37: 2642-7
    • (2009) Crit Care Med , vol.37 , pp. 2642-2647
    • Marik, P.E.1    Cavallazzi, R.2    Vasu, T.3    Hirani, A.4
  • 17
    • 84870253072 scopus 로고    scopus 로고
    • Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period
    • Le Manach Y, Hofer CK, Lehot JJ, et al. Can changes in arterial pressure be used to detect changes in cardiac output during volume expansion in the perioperative period? Anesthesiology 2012; 117: 1165-74
    • (2012) Anesthesiology , vol.117 , pp. 1165-1174
    • Le Manach, Y.1    Hofer, C.K.2    Lehot, J.J.3
  • 18
    • 84888303535 scopus 로고    scopus 로고
    • Accuracy of noninvasive estimated continuous cardiac output (esCCO) compared to thermodilution cardiac output: A pilot study in cardiac patients
    • Ball TR, Tricinella AP, Kimbrough BA, et al. Accuracy of noninvasive estimated continuous cardiac output (esCCO) compared to thermodilution cardiac output: a pilot study in cardiac patients. J Cardiothorac Vasc Anesth 2013; 27: 1128-32
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 1128-1132
    • Ball, T.R.1    Tricinella, A.P.2    Kimbrough, B.A.3
  • 19
    • 84893745633 scopus 로고    scopus 로고
    • The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography
    • Fischer MO, Balaire X, Le Mauff de Kergal C, et al. The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography. Can J Anaesth 2014; 61: 19-26
    • (2014) Can J Anaesth , vol.61 , pp. 19-26
    • Fischer, M.O.1    Balaire, X.2    Le Mauff De Kergal, C.3
  • 20
    • 84862986509 scopus 로고    scopus 로고
    • Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: A comparison with intermittent bolus thermodilution cardiac output
    • Yamada T, Tsutsui M, Sugo Y, et al. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output. Anesth Analg 2012; 115: 82-7
    • (2012) Anesth Analg , vol.115 , pp. 82-87
    • Yamada, T.1    Tsutsui, M.2    Sugo, Y.3
  • 21
    • 0028150641 scopus 로고
    • Invasive monitoring combined with two-dimensional echocardiographic study in septic shock
    • Jardin F, Valtier B, Beauchet A, Dubourg O, Bourdarias JP. Invasive monitoring combined with two-dimensional echocardiographic study in septic shock. Intensive Care Med 1994; 20: 550-4
    • (1994) Intensive Care Med , vol.20 , pp. 550-554
    • Jardin, F.1    Valtier, B.2    Beauchet, A.3    Dubourg, O.4    Bourdarias, J.P.5
  • 22
    • 0021173362 scopus 로고
    • Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: Clinical validation of two new methods using the apical window
    • Lewis JF, Kuo LC, Nelson JG, Limacher MC, Quinones MA. Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window. Circulation 1984; 70: 425-31
    • (1984) Circulation , vol.70 , pp. 425-431
    • Lewis, J.F.1    Kuo, L.C.2    Nelson, J.G.3    Limacher, M.C.4    Quinones, M.A.5
  • 23
    • 0030742696 scopus 로고    scopus 로고
    • Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject
    • McLean AS, Needham A, Stewart D, Parkin R. Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject. Anaesth Intensive Care 1997; 25: 250-4
    • (1997) Anaesth Intensive Care , vol.25 , pp. 250-254
    • McLean, A.S.1    Needham, A.2    Stewart, D.3    Parkin, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.