1
-
-
84907347369
-
Preoperative anaemia is associated with poor clinical outcome in non-cardiac surgery patients
-
Baron DM, Hochrieser H, Posch M, et al,. Preoperative anaemia is associated with poor clinical outcome in non-cardiac surgery patients. Br J Anaesth 2014; 113: 416-423.
-
(2014)
Br J Anaesth
, vol.113
, pp. 416-423
-
-
Baron, D.M.1
Hochrieser, H.2
Posch, M.3
-
2
-
-
79953178906
-
Performance evaluation of a noninvasive hemoglobin monitoring device
-
Gayat E, Bodin A, Sportiello C, et al,. Performance evaluation of a noninvasive hemoglobin monitoring device. Ann Emerg Med 2011; 57: 330-333.
-
(2011)
Ann Emerg Med
, vol.57
, pp. 330-333
-
-
Gayat, E.1
Bodin, A.2
Sportiello, C.3
-
3
-
-
84887945134
-
Comparison of haemoglobin measurement methods in the operating theatre
-
Giraud B, Frasca D, Debaene B, et al,. Comparison of haemoglobin measurement methods in the operating theatre. Br J Anaesth 2013; 111: 946-954.
-
(2013)
Br J Anaesth
, vol.111
, pp. 946-954
-
-
Giraud, B.1
Frasca, D.2
Debaene, B.3
-
4
-
-
84870985576
-
Evaluation of point-of-care haemoglobin measuring devices: A comparison of Radical-7 pulse co-oximetry, HemoCue((R)) and laboratory haemoglobin measurements in obstetric patients
-
Skelton VA, Wijayasinghe N, Sharafudeen S, et al,. Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7 pulse co-oximetry, HemoCue((R)) and laboratory haemoglobin measurements in obstetric patients. Anaesthesia 2013; 68: 40-45.
-
(2013)
Anaesthesia
, vol.68
, pp. 40-45
-
-
Skelton, V.A.1
Wijayasinghe, N.2
Sharafudeen, S.3
-
5
-
-
79953174576
-
A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery
-
Miller RD, Ward TA, Shiboski SC, et al,. A comparison of three methods of hemoglobin monitoring in patients undergoing spine surgery. Anesth Analg 2011; 112: 858-863.
-
(2011)
Anesth Analg
, vol.112
, pp. 858-863
-
-
Miller, R.D.1
Ward, T.A.2
Shiboski, S.C.3
-
6
-
-
84866353899
-
Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery
-
Vos JJ, Kalmar AF, Struys MM, et al,. Accuracy of non-invasive measurement of haemoglobin concentration by pulse co-oximetry during steady-state and dynamic conditions in liver surgery. Br J Anaesth 2012; 109: 522-528.
-
(2012)
Br J Anaesth
, vol.109
, pp. 522-528
-
-
Vos, J.J.1
Kalmar, A.F.2
Struys, M.M.3
-
8
-
-
82255179454
-
Continuous noninvasive hemoglobin monitoring during complex spine surgery
-
Berkow L, Rotolo S, Mirski E,. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg 2011; 113: 1396-1402.
-
(2011)
Anesth Analg
, vol.113
, pp. 1396-1402
-
-
Berkow, L.1
Rotolo, S.2
Mirski, E.3
-
9
-
-
84863089941
-
Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin
-
Colquhoun DA, Forkin KT, Durieux ME, et al,. Ability of the Masimo pulse CO-Oximeter to detect changes in hemoglobin. J Clin Monit Comput 2012; 26: 69-73.
-
(2012)
J Clin Monit Comput
, vol.26
, pp. 69-73
-
-
Colquhoun, D.A.1
Forkin, K.T.2
Durieux, M.E.3
-
10
-
-
84872679972
-
Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients
-
Isosu T, Obara S, Hosono A, et al,. Validation of continuous and noninvasive hemoglobin monitoring by pulse CO-oximetry in Japanese surgical patients. J Clin Monit Comput 2013; 27: 55-60.
-
(2013)
J Clin Monit Comput
, vol.27
, pp. 55-60
-
-
Isosu, T.1
Obara, S.2
Hosono, A.3
-
11
-
-
84655175025
-
Evaluation of pulse cooximetry in patients undergoing abdominal or pelvic surgery
-
Applegate RL 2nd, Barr SJ, Collier CE, et al,. Evaluation of pulse cooximetry in patients undergoing abdominal or pelvic surgery. Anesthesiology 2012; 116: 65-72.
-
(2012)
Anesthesiology
, vol.116
, pp. 65-72
-
-
Applegate, R.L.1
Barr, S.J.2
Collier, C.E.3
-
12
-
-
80052968149
-
Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients
-
Frasca D, Dahyot-Fizelier C, Catherine K, et al,. Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients. Crit Care Med 2011; 39: 2277-2282.
-
(2011)
Crit Care Med
, vol.39
, pp. 2277-2282
-
-
Frasca, D.1
Dahyot-Fizelier, C.2
Catherine, K.3
-
13
-
-
84865524824
-
Precision of noninvasive hemoglobin-level measurement by pulse co-oximetry in patients admitted to intensive care units for severe gastrointestinal bleeds
-
Coquin J, Dewitte A, Manach YL, et al,. Precision of noninvasive hemoglobin-level measurement by pulse co-oximetry in patients admitted to intensive care units for severe gastrointestinal bleeds. Crit Care Med 2012; 40: 2576-2582.
-
(2012)
Crit Care Med
, vol.40
, pp. 2576-2582
-
-
Coquin, J.1
Dewitte, A.2
Manach, Y.L.3
-
14
-
-
80055096355
-
The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery
-
Nguyen BV, Vincent JL, Nowak E, et al,. The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery. Anesth Analg 2011; 113: 1052-1057.
-
(2011)
Anesth Analg
, vol.113
, pp. 1052-1057
-
-
Nguyen, B.V.1
Vincent, J.L.2
Nowak, E.3
-
15
-
-
79955688079
-
Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station
-
Causey MW, Miller S, Foster A, et al,. Validation of noninvasive hemoglobin measurements using the Masimo Radical-7 SpHb Station. Am J Surg 2011; 201: 592-598.
-
(2011)
Am J Surg
, vol.201
, pp. 592-598
-
-
Causey, M.W.1
Miller, S.2
Foster, A.3
-
16
-
-
84885020676
-
Review article: Noninvasive hemoglobin monitoring: How accurate is enough?
-
Rice MJ, Gravenstein N, Morey TE,. Review article: noninvasive hemoglobin monitoring: how accurate is enough? Anesth Analg 2013; 117: 902-907.
-
(2013)
Anesth Analg
, vol.117
, pp. 902-907
-
-
Rice, M.J.1
Gravenstein, N.2
Morey, T.E.3
-
17
-
-
84904740603
-
Accuracy of continuous noninvasive hemoglobin monitoring: A systematic review and meta-analysis
-
Kim SH, Lilot M, Murphy LS, et al,. Accuracy of continuous noninvasive hemoglobin monitoring: a systematic review and meta-analysis. Anesth Analg 2014; 119: 332-346.
-
(2014)
Anesth Analg
, vol.119
, pp. 332-346
-
-
Kim, S.H.1
Lilot, M.2
Murphy, L.S.3
-
18
-
-
84870242563
-
The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery
-
Park YH, Lee JH, Song HG, et al,. The accuracy of noninvasive hemoglobin monitoring using the radical-7 pulse CO-Oximeter in children undergoing neurosurgery. Anesth Analg 2012; 115: 1302-1307.
-
(2012)
Anesth Analg
, vol.115
, pp. 1302-1307
-
-
Park, Y.H.1
Lee, J.H.2
Song, H.G.3
-
19
-
-
84873129901
-
The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates
-
Jung YH, Lee J, Kim HS, et al,. The efficacy of noninvasive hemoglobin measurement by pulse CO-oximetry in neonates. Pediatr Crit Care Med 2013; 14: 70-73.
-
(2013)
Pediatr Crit Care Med
, vol.14
, pp. 70-73
-
-
Jung, Y.H.1
Lee, J.2
Kim, H.S.3
-
20
-
-
84890485688
-
Use of non-invasive total hemoglobin measurement as a screening tool for anemia in children
-
Amano I, Murakami A,. Use of non-invasive total hemoglobin measurement as a screening tool for anemia in children. Pediatr Int 2013; 55: 803-805.
-
(2013)
Pediatr Int
, vol.55
, pp. 803-805
-
-
Amano, I.1
Murakami, A.2
-
21
-
-
84914152389
-
Trending and accuracy of noninvasive hemoglobin monitoring in pediatric perioperative patients
-
Patino M, Schultz L, Hossain M, et al,. Trending and accuracy of noninvasive hemoglobin monitoring in pediatric perioperative patients. Anesth Analg 2014; 119: 920-925.
-
(2014)
Anesth Analg
, vol.119
, pp. 920-925
-
-
Patino, M.1
Schultz, L.2
Hossain, M.3
-
23
-
-
15944373557
-
Performance evaluation of the ADVIA 2120 hematology analyzer: An international multicenter clinical trial
-
Harris N, Jou JM, Devoto G, et al,. Performance evaluation of the ADVIA 2120 hematology analyzer: an international multicenter clinical trial. Lab Hematol 2005; 11: 62-70.
-
(2005)
Lab Hematol
, vol.11
, pp. 62-70
-
-
Harris, N.1
Jou, J.M.2
Devoto, G.3
-
24
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
25
-
-
78650304152
-
The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution
-
Macknet MR, Allard M, Applegate RL 2nd, et al,. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution. Anesth Analg 2010; 111: 1424-1426.
-
(2010)
Anesth Analg
, vol.111
, pp. 1424-1426
-
-
Macknet, M.R.1
Allard, M.2
Applegate, R.L.3
-
26
-
-
0033369894
-
Current databases on biological variation: Pros, cons and progress
-
Ricos C, Alvarez V, Cava F, et al,. Current databases on biological variation: pros, cons and progress. Scand J Clin Lab Invest 1999; 59: 491-500.
-
(1999)
Scand J Clin Lab Invest
, vol.59
, pp. 491-500
-
-
Ricos, C.1
Alvarez, V.2
Cava, F.3
-
27
-
-
0028791287
-
Comparing methods of measurement: Why plotting difference against standard method is misleading
-
Bland JM, Altman DG,. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 1995; 346: 1085-1087.
-
(1995)
Lancet
, vol.346
, pp. 1085-1087
-
-
Bland, J.M.1
Altman, D.G.2
-
28
-
-
84655170265
-
Agreed statistics: Measurement method comparison
-
Bland JM, Altman DG,. Agreed statistics: measurement method comparison. Anesthesiology 2012; 116: 182-185.
-
(2012)
Anesthesiology
, vol.116
, pp. 182-185
-
-
Bland, J.M.1
Altman, D.G.2
-
29
-
-
79960271753
-
Let's think clinically instead of mathematically about device accuracy
-
Morey TE, Gravenstein N, Rice MJ,. Let's think clinically instead of mathematically about device accuracy. Anesth Analg 2011; 113: 89-91.
-
(2011)
Anesth Analg
, vol.113
, pp. 89-91
-
-
Morey, T.E.1
Gravenstein, N.2
Rice, M.J.3
-
30
-
-
84941133783
-
-
Masimo Corp. Irvine, CA: Masimo Corp
-
Masimo Corp. Masimo Radical-7 Operator Manual. Irvine, CA: Masimo Corp., 2012.
-
(2012)
Masimo Radical-7 Operator Manual
-
-
-
31
-
-
35548993658
-
Point of care hematocrit and hemoglobin in cardiac surgery: A review
-
Myers GJ, Browne J,. Point of care hematocrit and hemoglobin in cardiac surgery: a review. Perfusion 2007; 22: 179-183.
-
(2007)
Perfusion
, vol.22
, pp. 179-183
-
-
Myers, G.J.1
Browne, J.2
-
32
-
-
79960699090
-
Comparison of 3 different multianalyte point-of-care devices during clinical routine on a medical intensive care unit
-
Stadlbauer V, Wallner S, Stojakovic T, et al,. Comparison of 3 different multianalyte point-of-care devices during clinical routine on a medical intensive care unit. J Crit Care 2011; 26: e1-e11.
-
(2011)
J Crit Care
, vol.26
, pp. e1-e11
-
-
Stadlbauer, V.1
Wallner, S.2
Stojakovic, T.3
|