메뉴 건너뛰기




Volumn 26, Issue 6, 2016, Pages 1521-1528

Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

Author keywords

Calcium score; Dual source CT; High pitch; Ungated CT

Indexed keywords

ADULT; ARTICLE; CARDIOVASCULAR RISK; CHRONIC OBSTRUCTIVE LUNG DISEASE; COMPARATIVE STUDY; COMPUTED TOMOGRAPHY SCANNER; COMPUTER ASSISTED TOMOGRAPHY; CORONARY ARTERY CALCIFICATION; CORONARY ARTERY CALCIUM SCORE; DIAGNOSTIC TEST ACCURACY STUDY; DUAL SOURCE COMPUTED TOMOGRAPHY; ELECTROCARDIOGRAM; FALSE NEGATIVE RESULT; FEMALE; FOLLOW UP; HEART RATE; HIGH PITCH CHEST COMPUTED TOMOGRAPHY; HUMAN; INTERSTITIAL LUNG DISEASE; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MULTIDETECTOR COMPUTED TOMOGRAPHY; PNEUMONIA; PNEUMOTHORAX; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; SMOKING; AGED; CALCINOSIS; CARDIAC GATED IMAGING; CORONARY ARTERY DISEASE; CORONARY BLOOD VESSEL; DIAGNOSTIC IMAGING; ELECTROCARDIOGRAPHY; PROCEDURES; RADIATION DOSE; REPRODUCIBILITY; RISK FACTOR; VERY ELDERLY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84940875592     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-015-3978-7     Document Type: Article
Times cited : (35)

References (25)
  • 1
    • 0041429139 scopus 로고    scopus 로고
    • Prognostic value of cardiac risk factors and coronary calcium screening for all-cause mortality
    • PID: 12869688
    • Shaw LJ, Raggi P, Schisterman E, Berman DS, Callister TQ (2003) Prognostic value of cardiac risk factors and coronary calcium screening for all-cause mortality. Radiology 228:826–833
    • (2003) Radiology , vol.228 , pp. 826-833
    • Shaw, L.J.1    Raggi, P.2    Schisterman, E.3    Berman, D.S.4    Callister, T.Q.5
  • 2
    • 33646070564 scopus 로고    scopus 로고
    • Frequency of coronary artery calcification on low-dose computed tomography screening for lung cancer
    • PID: 16632153
    • Shemesh J, Henschke CI, Farooqi A et al (2006) Frequency of coronary artery calcification on low-dose computed tomography screening for lung cancer. Clin Imaging 30:181–185
    • (2006) Clin Imaging , vol.30 , pp. 181-185
    • Shemesh, J.1    Henschke, C.I.2    Farooqi, A.3
  • 3
    • 77249139130 scopus 로고    scopus 로고
    • Coronary artery calcium quantification with non-ECG-gated low-dose CT of the chest
    • COI: 1:STN:280:DC%2BC3c3msVeqtA%3D%3D, PID: 20035960
    • Bastarrika G, Alonso A, Saiz-Mendiguren R, Arias J, Cosin O (2010) Coronary artery calcium quantification with non-ECG-gated low-dose CT of the chest. Radiologia 52:30–36
    • (2010) Radiologia , vol.52 , pp. 30-36
    • Bastarrika, G.1    Alonso, A.2    Saiz-Mendiguren, R.3    Arias, J.4    Cosin, O.5
  • 4
    • 42449103419 scopus 로고    scopus 로고
    • Coronary arterial calcification on low-dose ungated MDCT for lung cancer screening: concordance study with dedicated cardiac CT
    • PID: 18356438
    • Wu MT, Yang P, Huang YL et al (2008) Coronary arterial calcification on low-dose ungated MDCT for lung cancer screening: concordance study with dedicated cardiac CT. AJR Am J Roentgenol 190:923–928
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 923-928
    • Wu, M.T.1    Yang, P.2    Huang, Y.L.3
  • 5
    • 79953721924 scopus 로고    scopus 로고
    • Coronary artery and thoracic calcium on noncontrast thoracic CT scans: comparison of ungated and gated examinations in patients from the COPD Gene cohort
    • PID: 21167806
    • Budoff MJ, Nasir K, Kinney GL et al (2011) Coronary artery and thoracic calcium on noncontrast thoracic CT scans: comparison of ungated and gated examinations in patients from the COPD Gene cohort. J Cardiovasc Comput Tomogr 5:113–118
    • (2011) J Cardiovasc Comput Tomogr , vol.5 , pp. 113-118
    • Budoff, M.J.1    Nasir, K.2    Kinney, G.L.3
  • 6
    • 77952097970 scopus 로고    scopus 로고
    • Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients
    • PID: 19890644
    • Tacelli N, Remy-Jardin M, Flohr T et al (2010) Dual-source chest CT angiography with high temporal resolution and high pitch modes: evaluation of image quality in 140 patients. Eur Radiol 20:1188–1196
    • (2010) Eur Radiol , vol.20 , pp. 1188-1196
    • Tacelli, N.1    Remy-Jardin, M.2    Flohr, T.3
  • 7
    • 84865620192 scopus 로고    scopus 로고
    • Ultrafast imaging of the entire chest without ECG synchronization or beta-blockade : to what extent can we analyze the coronary arteries ?
    • PID: 22696000
    • de Malherbe M, Duhamel A, Tacelli N et al (2012) Ultrafast imaging of the entire chest without ECG synchronization or beta-blockade: to what extent can we analyze the coronary arteries ? Insights Imaging 3:73–79
    • (2012) Insights Imaging , vol.3 , pp. 73-79
    • de Malherbe, M.1    Duhamel, A.2    Tacelli, N.3
  • 8
    • 84887321671 scopus 로고    scopus 로고
    • High-pitch, dual-source chest computed tomography angiography without electrocardiographic synchronization. Evaluation of cardiac motion artifacts on pulmonary circulation
    • PID: 23615574
    • Tacelli N, Darchis C, Pontana F et al (2013) High-pitch, dual-source chest computed tomography angiography without electrocardiographic synchronization. Evaluation of cardiac motion artifacts on pulmonary circulation. J Thorac Imaging 28:376–382
    • (2013) J Thorac Imaging , vol.28 , pp. 376-382
    • Tacelli, N.1    Darchis, C.2    Pontana, F.3
  • 9
    • 79952440432 scopus 로고    scopus 로고
    • Computed tomography of the lung in the high-pitch mode: is breath holding still required?
    • PID: 21217528
    • Baumueller S, Alkadhi A, Stolzmann P et al (2011) Computed tomography of the lung in the high-pitch mode: is breath holding still required? Invest Radiol 46:240–245
    • (2011) Invest Radiol , vol.46 , pp. 240-245
    • Baumueller, S.1    Alkadhi, A.2    Stolzmann, P.3
  • 10
    • 84868303687 scopus 로고    scopus 로고
    • Quantitative analysis of motion artifacts in high-pitch dual-source computed tomography of the thorax
    • PID: 22627616
    • Schulz B, Jacobi V, Beeres M et al (2012) Quantitative analysis of motion artifacts in high-pitch dual-source computed tomography of the thorax. J Thorac Imaging 27:382–386
    • (2012) J Thorac Imaging , vol.27 , pp. 382-386
    • Schulz, B.1    Jacobi, V.2    Beeres, M.3
  • 11
    • 84868301324 scopus 로고    scopus 로고
    • High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients
    • PID: 22487993
    • Bauer RW, Schell B, Beeres M et al (2012) High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients. J Thorac Imaging 27:376–381
    • (2012) J Thorac Imaging , vol.27 , pp. 376-381
    • Bauer, R.W.1    Schell, B.2    Beeres, M.3
  • 13
    • 51549088875 scopus 로고    scopus 로고
    • Converting dose-length-product to effective dose at CT
    • PID: 18710988
    • Huda W, Ogden KM, Khorasani MR (2008) Converting dose-length-product to effective dose at CT. Radiology 248:995–1003
    • (2008) Radiology , vol.248 , pp. 995-1003
    • Huda, W.1    Ogden, K.M.2    Khorasani, M.R.3
  • 14
    • 84884488278 scopus 로고    scopus 로고
    • Validation and prognosis of coronary artery calcium scoring in nontriggered thoracic computed tomography. Systematic review and meta-analysis
    • PID: 23756678
    • Xie X, Zhao Y, de Bock G et al (2013) Validation and prognosis of coronary artery calcium scoring in nontriggered thoracic computed tomography. Systematic review and meta-analysis. Circ Cardiovasc Imaging 6:514–521
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 514-521
    • Xie, X.1    Zhao, Y.2    de Bock, G.3
  • 15
    • 84962885514 scopus 로고    scopus 로고
    • Coronary artery calcium score on low-dose computed tomography for lung cancer screening
    • PID: 24976939
    • Arcadi T, Maffei E, Sverzellati N et al (2014) Coronary artery calcium score on low-dose computed tomography for lung cancer screening. World J Radiol 6:381–387
    • (2014) World J Radiol , vol.6 , pp. 381-387
    • Arcadi, T.1    Maffei, E.2    Sverzellati, N.3
  • 16
    • 70350705556 scopus 로고    scopus 로고
    • A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density and temporal resolution: a cardiac phantom study
    • COI: 1:STN:280:DC%2BD1MfhtF2hsg%3D%3D, PID: 19994518
    • Greuter MJ, Groen JM, Nicolai LJ, Dijkstra H, Oudkerk M (2009) A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density and temporal resolution: a cardiac phantom study. Med Phys 36:5079–5088
    • (2009) Med Phys , vol.36 , pp. 5079-5088
    • Greuter, M.J.1    Groen, J.M.2    Nicolai, L.J.3    Dijkstra, H.4    Oudkerk, M.5
  • 17
    • 0031860874 scopus 로고    scopus 로고
    • Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification
    • COI: 1:STN:280:DyaK1c3ovVGmuw%3D%3D, PID: 9626870
    • Hofman MB, Wickline SA, Lorenz CH (1998) Quantification of in-plane motion of the coronary arteries during the cardiac cycle: implications for acquisition window duration for MR flow quantification. J Magn Reson Imaging 8:568–76
    • (1998) J Magn Reson Imaging , vol.8 , pp. 568-576
    • Hofman, M.B.1    Wickline, S.A.2    Lorenz, C.H.3
  • 18
    • 84863952703 scopus 로고    scopus 로고
    • Comorbidities and risk of mortality in patients with chronic obstructive pulmonary disease
    • PID: 22561964
    • Divo M, Cote C, de Torres JP et al (2012) Comorbidities and risk of mortality in patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med 186:155–161
    • (2012) Am J Respir Crit Care Med , vol.186 , pp. 155-161
    • Divo, M.1    Cote, C.2    de Torres, J.P.3
  • 19
    • 84867149937 scopus 로고    scopus 로고
    • Computed tomographic screening for lung cancer: an opportunity to evaluate other diseases
    • COI: 1:CAS:528:DC%2BC38XhsFChsr3N, PID: 23047354
    • Mets OM, de Jong PA, Prokop M (2012) Computed tomographic screening for lung cancer: an opportunity to evaluate other diseases. JAMA 308:1433–1434
    • (2012) JAMA , vol.308 , pp. 1433-1434
    • Mets, O.M.1    de Jong, P.A.2    Prokop, M.3
  • 20
    • 71949090707 scopus 로고    scopus 로고
    • Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography
    • PID: 20083060
    • Nakazato R, Dey D, Gutstein A et al (2009) Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography. J Cardiovasc Comput Tomogr 3:394–400
    • (2009) J Cardiovasc Comput Tomogr , vol.3 , pp. 394-400
    • Nakazato, R.1    Dey, D.2    Gutstein, A.3
  • 21
    • 33747038401 scopus 로고    scopus 로고
    • Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol
    • PID: 16896301
    • Thomas CK, Mühlenbruch G, Wildberger JE et al (2006) Coronary artery calcium scoring with multislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol 41:668–673
    • (2006) Invest Radiol , vol.41 , pp. 668-673
    • Thomas, C.K.1    Mühlenbruch, G.2    Wildberger, J.E.3
  • 22
    • 80052800431 scopus 로고    scopus 로고
    • Quantitative evaluation of calcium (content) in the coronary artery using hybrid iterative reconstruction (iDose) algorithm on low-dose 64-detector CT: comparison of iDose and filtered back projection
    • PID: 21532246
    • Murazaki H, Funama Y, Hatemura M, Fujioka C, Tomiguchi S (2011) Quantitative evaluation of calcium (content) in the coronary artery using hybrid iterative reconstruction (iDose) algorithm on low-dose 64-detector CT: comparison of iDose and filtered back projection. Nihon Hoshasen Gijutsu Gakkai Zasshi 67:360–366
    • (2011) Nihon Hoshasen Gijutsu Gakkai Zasshi , vol.67 , pp. 360-366
    • Murazaki, H.1    Funama, Y.2    Hatemura, M.3    Fujioka, C.4    Tomiguchi, S.5
  • 23
    • 84883805766 scopus 로고    scopus 로고
    • Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT
    • PID: 22959869
    • Gebhard C, Fiechter M, Fuchs TA et al (2013) Coronary artery calcium scoring: Influence of adaptive statistical iterative reconstruction using 64-MDCT. Int J Cardiol 167:2932–2937
    • (2013) Int J Cardiol , vol.167 , pp. 2932-2937
    • Gebhard, C.1    Fiechter, M.2    Fuchs, T.A.3
  • 24
    • 84905678573 scopus 로고    scopus 로고
    • Influence of iterative image reconstruction on CT-based calcium score measurements
    • PID: 24676668
    • van Osch JA, Mouden M, van Dalen JA et al (2014) Influence of iterative image reconstruction on CT-based calcium score measurements. Int J Cardiovasc Imaging 30:961–967
    • (2014) Int J Cardiovasc Imaging , vol.30 , pp. 961-967
    • van Osch, J.A.1    Mouden, M.2    van Dalen, J.A.3
  • 25
    • 84922017571 scopus 로고    scopus 로고
    • Radiation dose reduction at coronary artery calcium scoring by using a low tube current technique and hybrid iterative reconstruction
    • Matsuura N, Urashima M, Fukumoto W et al (2015) Radiation dose reduction at coronary artery calcium scoring by using a low tube current technique and hybrid iterative reconstruction. J Comput Asssit Tomogr 39:119–124
    • (2015) J Comput Asssit Tomogr , vol.39 , pp. 119-124
    • Matsuura, N.1    Urashima, M.2    Fukumoto, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.