메뉴 건너뛰기




Volumn 27, Issue 6, 2012, Pages 376-381

High-pitch dual-source computed tomography pulmonary angiography in freely breathing patients

Author keywords

computed tomography pulmonary angiography; dual source computed tomography; free breathing; high pitch computed tomography; Valsalva maneuver

Indexed keywords

ADULT; AGE DISTRIBUTION; AGED; ARTICLE; ATTENUATION; BREATHING; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; COMPUTED TOMOGRAPHIC PULMONARY ANGIOGRAPHY; CONTROLLED STUDY; DIAPHRAGM; FEMALE; HEART MOVEMENT; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INCIDENCE; LUNG ANGIOGRAPHY; LUNG BLOOD VESSEL; LUNG EMBOLISM; LUNG STRUCTURE; MAJOR CLINICAL STUDY; MALE; NOISE; PULMONARY ARTERY; SEX RATIO; SIGNAL NOISE RATIO; VALSALVA MANEUVER;

EID: 84868301324     PISSN: 08835993     EISSN: 15360237     Source Type: Journal    
DOI: 10.1097/RTI.0b013e318250067e     Document Type: Article
Times cited : (42)

References (23)
  • 1
    • 35349026173 scopus 로고    scopus 로고
    • Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society
    • Remy-Jardin M, Pistolesi M, Goodman LR, et al. Management of suspected acute pulmonary embolism in the era of CT angiography: A statement from the Fleischner Society. Radiology. 2007;245:315-329
    • (2007) Radiology , vol.245 , pp. 315-329
    • Remy-Jardin, M.1    Pistolesi, M.2    Goodman, L.R.3
  • 2
    • 30744457853 scopus 로고    scopus 로고
    • ProkopM.MDCT for the diagnosis of acute pulmonary embolism
    • SCHAEFER-Prokop C, ProkopM.MDCT for the diagnosis of acute pulmonary embolism. Eur Radiol. 2005;15(suppl 4):D37-D41.
    • (2005) Eur Radiol , vol.15 , Issue.SUPPL. 4
    • Schaefer-Prokop, C.1
  • 4
    • 52449110713 scopus 로고    scopus 로고
    • Guidelines on the diagnosis and management of acute pulmonary embolism: The Task Force for the Diagnosis and Management of Acute Pulmonary Embolism of the European Society of Cardiology (ESC
    • Torbicki A, Perrier A, Konstantinides S, et al. Guidelines on the diagnosis and management of acute pulmonary embolism: The Task Force for the Diagnosis and Management of Acute Pulmonary Embolism of the European Society of Cardiology (ESC). Eur Heart J. 2008;29:2276-2315
    • (2008) Eur Heart J. , vol.29 , pp. 2276-2315
    • Torbicki, A.1    Perrier, A.2    Konstantinides, S.3
  • 5
    • 1642575993 scopus 로고    scopus 로고
    • Contrast dynamics during CT pulmonary angiogram: Analysis of an inspiration associated artifact
    • Gosselin MV, Rassner UA, Thieszen SL, et al. Contrast dynamics during CT pulmonary angiogram: Analysis of an inspiration associated artifact. J Thorac Imaging. 2004;19:1-7.
    • (2004) J Thorac Imaging , vol.19 , pp. 1-7
    • Gosselin, M.V.1    Rassner, U.A.2    Thieszen, S.L.3
  • 6
    • 34249905598 scopus 로고    scopus 로고
    • Transient interruption of contrast on CT pulmonary angiography: Proof of mechanism
    • Wittram C, Yoo AJ. Transient interruption of contrast on CT pulmonary angiography: Proof of mechanism. J Thorac Imaging. 2007;22:125-129
    • (2007) J Thorac Imaging , vol.22 , pp. 125-129
    • Wittram, C.1    Yoo, A.J.2
  • 7
    • 43349106419 scopus 로고    scopus 로고
    • Waiting to exhale: Salvaging the nondiagnostic CT pulmonary angiogram by using expiratory imaging to improve contrast dynamics
    • Chen YH, Velayudhan V, Weltman DI, et al. Waiting to exhale: Salvaging the nondiagnostic CT pulmonary angiogram by using expiratory imaging to improve contrast dynamics. Emerg Radiol. 2008;15:161-169
    • (2008) Emerg Radiol , vol.15 , pp. 161-169
    • Chen, Y.H.1    Velayudhan, V.2    Weltman, D.I.3
  • 8
    • 72049130251 scopus 로고    scopus 로고
    • Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality
    • Flohr TG, Leng S, Yu L, et al. Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality. Med Phys. 2009;36:5641-5653
    • (2009) Med Phys , vol.36 , pp. 5641-5653
    • Flohr, T.G.1    Leng, S.2    Yu, L.3
  • 9
    • 77952520540 scopus 로고    scopus 로고
    • Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency
    • Goetti R, Leschka S, Baumuller S, et al. Low dose high-pitch spiral acquisition 128-slice dual-source computed tomography for the evaluation of coronary artery bypass graft patency. Invest Radiol. 2010;45:324-330
    • (2010) Invest Radiol , Issue.45 , pp. 324-330
    • Goetti, R.1    Leschka, S.2    Baumuller, S.3
  • 10
    • 0029400239 scopus 로고
    • Phasecontrast echo-planar MR imaging: Real-time quantification of flow and velocity patterns in the thoracic vessels induced by Valsalva's maneuver
    • Eichenberger AC, Schwitter J, McKinnon GC, et al. Phasecontrast echo-planar MR imaging: Real-time quantification of flow and velocity patterns in the thoracic vessels induced by Valsalva's maneuver. J Magn Reson Imaging. 1995;5: 648-655
    • (1995) J Magn Reson Imaging , vol.5 , pp. 648-655
    • Eichenberger, A.C.1    Schwitter, J.2    McKinnon, G.C.3
  • 11
    • 0025335186 scopus 로고
    • Doppler echocardiographic flow velocity measurements in the superior vena cava during the Valsalva maneuver in normal subjects
    • Gindea AJ, Slater J, Kronzon I. Doppler echocardiographic flow velocity measurements in the superior vena cava during the Valsalva maneuver in normal subjects. Am J Cardiol. 1990;65:1387-1391
    • (1990) Am J Cardiol , vol.65 , pp. 1387-1391
    • Gindea, A.J.1    Slater, J.2    Kronzon, I.3
  • 12
    • 33847238770 scopus 로고    scopus 로고
    • Measurement of caval blood flow with MRI during respiratory maneuvers: Implications for vascular contrast opacification on pulmonary CT angiographic studies
    • Kuzo RS, Pooley RA, Crook JE, et al. Measurement of caval blood flow with MRI during respiratory maneuvers: Implications for vascular contrast opacification on pulmonary CT angiographic studies. Am J Roentgenol. 2007;188:839-842
    • (2007) Am J Roentgenol , vol.188 , pp. 839-842
    • Kuzo, R.S.1    Pooley, R.A.2    Crook, J.E.3
  • 13
    • 81455154454 scopus 로고    scopus 로고
    • Use of expiratory CT pulmonary angiography to reduce inspiration and breathhold associated artefact: Contrast dynamics and implications for scan protocol
    • Mortimer AM, Singh RK, Hughes J, et al. Use of expiratory CT pulmonary angiography to reduce inspiration and breathhold associated artefact: Contrast dynamics and implications for scan protocol. Clin Radiol. 2011;66:1159-1166
    • (2011) Clin Radiol , Issue.66 , pp. 1159-1166
    • Mortimer, A.M.1    Singh, R.K.2    Hughes, J.3
  • 14
    • 77749304526 scopus 로고    scopus 로고
    • Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality
    • Bjorkdahl P, Nyman U. Using 100- instead of 120-kVp computed tomography to diagnose pulmonary embolism almost halves the radiation dose with preserved diagnostic quality. Acta Radiol. 2010;51:260-270
    • (2010) Acta Radiol , Issue.51 , pp. 260-270
    • Bjorkdahl, P.1    Nyman, U.2
  • 15
    • 35348977748 scopus 로고    scopus 로고
    • Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study
    • Heyer CM, Mohr PS, Lemburg SP, et al. Image quality and radiation exposure at pulmonary CT angiography with 100- or 120-kVp protocol: Prospective randomized study. Radiology. 2007;245:577-583
    • (2007) Radiology , vol.245 , pp. 577-583
    • Heyer, C.M.1    Mohr, P.S.2    Lemburg, S.P.3
  • 16
    • 59649088090 scopus 로고    scopus 로고
    • Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols
    • Szucs-Farkas Z, Kurmann L, Strautz T, et al. Patient exposure and image quality of low-dose pulmonary computed tomography angiography: Comparison of 100- and 80-kVp protocols. Invest Radiol. 2008;43:871-876
    • (2008) Invest Radiol , vol.43 , pp. 871-876
    • Szucs-Farkas, Z.1    Kurmann, L.2    Strautz, T.3
  • 17
    • 80053895681 scopus 로고    scopus 로고
    • Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice C.T
    • Bauer RW, Kramer S, Renker M, et al. Dose and image quality at CT pulmonary angiography-comparison of first and second generation dual-energy CT and 64-slice CT. Eur Radiol. 2011;21:2139-2147
    • (2011) Eur Radiol , Issue.21 , pp. 2139-2147
    • Bauer, R.W.1    Kramer, S.2    Renker, M.3
  • 18
    • 84856599481 scopus 로고    scopus 로고
    • Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: High-pitch dual source CT, dual energy CT and conventional spiral C.T
    • De Zordo T, von Lutterotti K, Dejaco C, et al. Comparison of image quality and radiation dose of different pulmonary CTA protocols on a 128-slice CT: High-pitch dual source CT, dual energy CT and conventional spiral CT. Eur Radiol. 2012;22: 279-286
    • (2012) Eur Radiol , Issue.22 , pp. 279-286
    • De Zordo, T.1    Von Lutterotti, K.2    Dejaco, C.3
  • 19
    • 70349868350 scopus 로고    scopus 로고
    • Cardiac spiral dual-source CT with high pitch: A feasibility study
    • Ertel D, Lell MM, Harig F, et al. Cardiac spiral dual-source CT with high pitch: A feasibility study. Eur Radiol. 2009;19: 2357-2362
    • (2009) Eur Radiol , vol.19 , pp. 2357-2362
    • Ertel, D.1    Lell, M.M.2    Harig, F.3
  • 20
    • 70350210490 scopus 로고    scopus 로고
    • Prospectively ECGtriggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience
    • Lell M, Marwan M, Schepis T, et al. Prospectively ECGtriggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: Technique and initial experience. Eur Radiol. 2009;19:2576-2583
    • (2009) Eur Radiol , vol.19 , pp. 2576-2583
    • Lell, M.1    Marwan, M.2    Schepis, T.3
  • 21
    • 71449119488 scopus 로고    scopus 로고
    • Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: First experience
    • Leschka S, Stolzmann P, Desbiolles L, et al. Diagnostic accuracy of high-pitch dual-source CT for the assessment of coronary stenoses: First experience. Eur Radiol. 2009;19: 2896-2903
    • (2009) Eur Radiol , vol.19 , pp. 2896-2903
    • Leschka, S.1    Stolzmann, P.2    Desbiolles, L.3
  • 22
    • 80052721781 scopus 로고    scopus 로고
    • Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - Correlation with D-dimer level, right heart strain and clinical outcome
    • Bauer RW, Frellesen C, Renker M, et al. Dual energy CT pulmonary blood volume assessment in acute pulmonary embolism - correlation with D-dimer level, right heart strain and clinical outcome. Eur Radiol. 2011;21:1914-1921
    • (2011) Eur Radiol , vol.21 , pp. 1914-1921
    • Bauer, R.W.1    Frellesen, C.2    Renker, M.3
  • 23
    • 84856619004 scopus 로고    scopus 로고
    • Severity assessment of pulmonary embolism using dual energy CT - Correlation of a pulmonary perfusion defect score with clinical and morphological parameters of blood oxygenation and right ventricular failure
    • Thieme SF, Ashoori N, Bamberg F, et al. Severity assessment of pulmonary embolism using dual energy CT - correlation of a pulmonary perfusion defect score with clinical and morphological parameters of blood oxygenation and right ventricular failure. Eur Radiol. 2012;22:269-278.
    • (2012) Eur Radiol , Issue.22 , pp. 269-278
    • Thieme, S.F.1    Ashoori, N.2    Bamberg, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.