Volumn 45, Issue 10, 2015, Pages 1455-1464

Optimized protocols for cardiac magnetic resonance imaging in patients with thoracic metallic implants

Author keywords

Artifact; Children; Congenital heart disease; Heart; Magnetic resonance imaging; Metal

Indexed keywords

ADOLESCENT; ADULT; AMPLATZER VASCULAR PLUG; ARTICLE; ARTIFACT REDUCTION; CARDIOVASCULAR MAGNETIC RESONANCE; CHILD; CLINICAL PROTOCOL; CONGENITAL HEART DISEASE; FEMALE; HUMAN; IN VITRO STUDY; IN VIVO STUDY; MAJOR CLINICAL STUDY; MALE; METAL IMPLANT; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROCESS OPTIMIZATION; SCORING SYSTEM; SIGNAL NOISE RATIO; STEADY STATE; VENTRICULAR SEPTAL OCCLUDER; ARTIFACT; CARDIAC MUSCLE; HEART DEFECTS, CONGENITAL; IMAGING PHANTOM; PATHOLOGY; PRESCHOOL CHILD; PROSTHESES AND ORTHOSES; REPRODUCIBILITY; THORACIC AORTA; YOUNG ADULT;

EID: 84940580420     PISSN: 03010449     EISSN: 14321998     Source Type: Journal    
DOI: 10.1007/s00247-015-3366-0     Document Type: Article
Times cited : (17)

References (18)
  • 1
    • 79958785454 scopus 로고    scopus 로고
    • Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association
    • PID: 21536996
    • Feltes TF, Bacha E, Beekman RH 3rd et al (2011) Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association. Circulation 123:2607–2652
    • (2011) Circulation , vol.123 , pp. 2607-2652
    • Feltes, T.F.1    Bacha, E.2    Beekman, R.H.3
  • 2
    • 0031783747 scopus 로고    scopus 로고
    • Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI
    • COI: 1:STN:280:DyaK1M%2FmtlCqtw%3D%3D, PID: 9848749
    • Shellock FG, Shellock VJ (1998) Cardiovascular catheters and accessories: ex vivo testing of ferromagnetism, heating, and artifacts associated with MRI. J Magn Reson Imaging 8:1338–1342
    • (1998) J Magn Reson Imaging , vol.8 , pp. 1338-1342
    • Shellock, F.G.1    Shellock, V.J.2
  • 3
    • 14844362253 scopus 로고    scopus 로고
    • Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent
    • PID: 15723984
    • Spuentrup E, Ruebben A, Mahnken A et al (2005) Artifact-free coronary magnetic resonance angiography and coronary vessel wall imaging in the presence of a new, metallic, coronary magnetic resonance imaging stent. Circulation 111:1019–1026
    • (2005) Circulation , vol.111 , pp. 1019-1026
    • Spuentrup, E.1    Ruebben, A.2    Mahnken, A.3
  • 4
    • 84893656980 scopus 로고    scopus 로고
    • Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: late gadolinium enhancement correlation with electroanatomic mapping
    • PID: 24140812
    • Stevens SM, Tung R, Rashid S et al (2014) Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: late gadolinium enhancement correlation with electroanatomic mapping. Heart Rhythm 11:289–298
    • (2014) Heart Rhythm , vol.11 , pp. 289-298
    • Stevens, S.M.1    Tung, R.2    Rashid, S.3
  • 5
    • 0033087272 scopus 로고    scopus 로고
    • Fat suppression in MR imaging: techniques and pitfalls
    • COI: 1:STN:280:DyaK1M3htVKruw%3D%3D
    • Delfaut EM, Beltran J, Johnson G et al (1999) Fat suppression in MR imaging: techniques and pitfalls. Radiogr Rev 19:373–382
    • (1999) Radiogr Rev , vol.19 , pp. 373-382
    • Delfaut, E.M.1    Beltran, J.2    Johnson, G.3
  • 6
    • 0037950204 scopus 로고    scopus 로고
    • Metallic renal artery MR imaging stent: artifact-free lumen visualization with projection and standard renal MR angiography
    • PID: 12773688
    • Spuentrup E, Ruebben A, Stuber M et al (2003) Metallic renal artery MR imaging stent: artifact-free lumen visualization with projection and standard renal MR angiography. Radiology 227:897–902
    • (2003) Radiology , vol.227 , pp. 897-902
    • Spuentrup, E.1    Ruebben, A.2    Stuber, M.3
  • 8
    • 79952196693 scopus 로고    scopus 로고
    • Magnetic resonance imaging near metal implants
    • COI: 1:STN:280:DC%2BC3cfmtFOqug%3D%3D, PID: 20882607
    • Koch KM, Hargreaves BA, Pauly KB et al (2010) Magnetic resonance imaging near metal implants. J Magn Reson Imaging 32:773–787
    • (2010) J Magn Reson Imaging , vol.32 , pp. 773-787
    • Koch, K.M.1    Hargreaves, B.A.2    Pauly, K.B.3
  • 9
    • 37349049968 scopus 로고    scopus 로고
    • Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance
    • PID: 18025533
    • Levine GN, Gomes AS, Arai AE et al (2007) Safety of magnetic resonance imaging in patients with cardiovascular devices: an American Heart Association scientific statement from the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance. Circulation 116:2878–2891
    • (2007) Circulation , vol.116 , pp. 2878-2891
    • Levine, G.N.1    Gomes, A.S.2    Arai, A.E.3
  • 10
    • 0036948213 scopus 로고    scopus 로고
    • Comparative MRI compatibility of 316 L stainless steel alloy and nickel-titanium alloy stents
    • PID: 12549230
    • Holton A, Walsh E, Anayiotos A et al (2002) Comparative MRI compatibility of 316 L stainless steel alloy and nickel-titanium alloy stents. J Cardiovasc Magn Reson 4:423–430
    • (2002) J Cardiovasc Magn Reson , vol.4 , pp. 423-430
    • Holton, A.1    Walsh, E.2    Anayiotos, A.3
  • 11
    • 0035667949 scopus 로고    scopus 로고
    • Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 tesla
    • COI: 1:STN:280:DC%2BD38%2FkvF2isw%3D%3D, PID: 11777223
    • Shellock FG (2001) Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 tesla. J Cardiovasc Magn Reson 3:317–324
    • (2001) J Cardiovasc Magn Reson , vol.3 , pp. 317-324
    • Shellock, F.G.1
  • 12
    • 29244442275 scopus 로고    scopus 로고
    • Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T
    • PID: 16376188
    • Shellock FG, Valencerina S (2005) Septal repair implants: evaluation of magnetic resonance imaging safety at 3 T. Magn Reson Imaging 23:1021–1025
    • (2005) Magn Reson Imaging , vol.23 , pp. 1021-1025
    • Shellock, F.G.1    Valencerina, S.2
  • 13
    • 77950963615 scopus 로고    scopus 로고
    • ACC/AHA 2008 guidelines for the management of adults with congenital heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to develop guidelines on the management of adults with congenital heart disease). Developed in collaboration with the American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons
    • PID: 19038677
    • Warnes CA, Williams RG, Bashore TM et al (2008) ACC/AHA 2008 guidelines for the management of adults with congenital heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing committee to develop guidelines on the management of adults with congenital heart disease). Developed in collaboration with the American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J Am Coll Cardiol 52:e143–263
    • (2008) J Am Coll Cardiol , vol.52 , pp. 143-263
    • Warnes, C.A.1    Williams, R.G.2    Bashore, T.M.3
  • 14
    • 77950605352 scopus 로고    scopus 로고
    • Canadian Cardiovascular Society 2009 consensus conference on the management of adults with congenital heart disease: executive summary
    • PID: 20352134
    • Silversides CK, Marelli A, Beauchesne L et al (2010) Canadian Cardiovascular Society 2009 consensus conference on the management of adults with congenital heart disease: executive summary. Can J Cardiol 26:143–150
    • (2010) Can J Cardiol , vol.26 , pp. 143-150
    • Silversides, C.K.1    Marelli, A.2    Beauchesne, L.3
  • 15
    • 84878818144 scopus 로고    scopus 로고
    • Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease
    • PID: 23763839
    • Fratz S, Chung T, Greil GF et al (2013) Guidelines and protocols for cardiovascular magnetic resonance in children and adults with congenital heart disease: SCMR expert consensus group on congenital heart disease. J Cardiovasc Magn Reson 15:51
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 51
    • Fratz, S.1    Chung, T.2    Greil, G.F.3
  • 16
    • 0037407468 scopus 로고    scopus 로고
    • Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, cobalt-alloy, and stainless steel stents
    • PID: 12704782
    • Wang Y, Truong TN, Yen C et al (2003) Quantitative evaluation of susceptibility and shielding effects of nitinol, platinum, cobalt-alloy, and stainless steel stents. Magn Reson Med 49:972–976
    • (2003) Magn Reson Med , vol.49 , pp. 972-976
    • Wang, Y.1    Truong, T.N.2    Yen, C.3
  • 17
    • 84879063853 scopus 로고    scopus 로고
    • Pediatric cardiovascular interventional devices: effect on CMR images at 1.5 and 3 tesla
    • PID: 23782716
    • Khan SN, Rapacchi S, Levi DS et al (2013) Pediatric cardiovascular interventional devices: effect on CMR images at 1.5 and 3 tesla. J Cardiovasc Magn Reson 15:54
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 54
    • Khan, S.N.1    Rapacchi, S.2    Levi, D.S.3
  • 18
    • 84887357485 scopus 로고    scopus 로고
    • High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions
    • PID: 24228930
    • Xue H, Kellman P, Larocca G et al (2013) High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions. J Cardiovasc Magn Reson 15:102
    • (2013) J Cardiovasc Magn Reson , vol.15 , pp. 102
    • Xue, H.1    Kellman, P.2    Larocca, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.