메뉴 건너뛰기




Volumn 59, Issue 5, 2014, Pages 503-515

Outdoor thermal physiology along human pathways: a study using a wearable measurement system

Author keywords

Globe thermometer; Mean radiant temperature; Mobile observation; Outdoor thermal comfort; Outdoor thermal physiology; Sweat rate

Indexed keywords

ACCLIMATIZATION; ADULT; AGED; AMBULATORY MONITORING; CLIMATE; DAILY LIFE ACTIVITY; ENVIRONMENTAL MONITORING; FEMALE; HUMAN; JAPAN; MALE; MIDDLE AGED; PEDESTRIAN; PHYSIOLOGY; PROCEDURES; SPATIOTEMPORAL ANALYSIS; TEMPERATURE; THERMOREGULATION; WALKING; YOUNG ADULT;

EID: 84939872411     PISSN: 00207128     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00484-014-0864-y     Document Type: Article
Times cited : (70)

References (20)
  • 1
    • 0037210755 scopus 로고    scopus 로고
    • Comfort in urban spaces: defining the boundaries of outdoor thermal comfort for the tropical urban environments
    • Ahmed KS (2003) Comfort in urban spaces: defining the boundaries of outdoor thermal comfort for the tropical urban environments. Energ Build 35:103–110
    • (2003) Energ Build , vol.35 , pp. 103-110
    • Ahmed, K.S.1
  • 2
    • 0031013941 scopus 로고    scopus 로고
    • Relationships between oxygen consumption and heart rate in transitory and steady states of exercise and during recovery: influence of type of exercise
    • COI: 1:STN:280:DyaK2s7nsVamsQ%3D%3D
    • Bernard T, Gavarry O, Bermon S, Glacomoni M, Marconnet P, Flagairette G (1997) Relationships between oxygen consumption and heart rate in transitory and steady states of exercise and during recovery: influence of type of exercise. Eur J Appl Physiol 75:170–176
    • (1997) Eur J Appl Physiol , vol.75 , pp. 170-176
    • Bernard, T.1    Gavarry, O.2    Bermon, S.3    Glacomoni, M.4    Marconnet, P.5    Flagairette, G.6
  • 3
    • 0023670329 scopus 로고
    • Ping pong globe thermometers for mean radiant temperature: heating and ventilating engineer
    • de Dear RJ (1987) Ping pong globe thermometers for mean radiant temperature: heating and ventilating engineer. J Air Cond 60(681):10–12
    • (1987) J Air Cond , vol.60 , Issue.681 , pp. 10-12
    • de Dear, R.J.1
  • 4
    • 79953094218 scopus 로고    scopus 로고
    • Revisiting an old hypothesis of human thermal perception: alliesthesia
    • de Dear R (2011) Revisiting an old hypothesis of human thermal perception: alliesthesia. Build Res Inform 39:108–117
    • (2011) Build Res Inform , vol.39 , pp. 108-117
    • de Dear, R.1
  • 6
    • 0015248608 scopus 로고
    • An effective temperature scale based on a simple model of human physiological regulatory response
    • Gagge AP, Stolwijk JAJ, Nishi Y (1971) An effective temperature scale based on a simple model of human physiological regulatory response. ASHRAE Trans 77:246–262
    • (1971) ASHRAE Trans , vol.77 , pp. 246-262
    • Gagge, A.P.1    Stolwijk, J.A.J.2    Nishi, Y.3
  • 7
    • 0001636091 scopus 로고
    • The technique of measuring radiation and convection
    • COI: 1:CAS:528:DyaA1cXltlGhsA%3D%3D
    • Hardy JD, DuBois EF (1938) The technique of measuring radiation and convection. J Nutr 15:461–475
    • (1938) J Nutr , vol.15 , pp. 461-475
    • Hardy, J.D.1    DuBois, E.F.2
  • 8
    • 84939872382 scopus 로고    scopus 로고
    • Cooling system with water mist sprayers for mitigation of heat-island. In Proceedings of the Seventh International Conference on Urban Climate, ICUC-7, Yokohama, Japan
    • Ishii T, Tsujimoto M, Yoon G, Okumiya M (2009) Cooling system with water mist sprayers for mitigation of heat-island. In Proceedings of the Seventh International Conference on Urban Climate, ICUC-7, Yokohama, Japan, June 28-July 3 2009.
    • (2009) June 28-July , vol.3 , pp. 2009
    • Ishii, T.1    Tsujimoto, M.2    Yoon, G.3    Okumiya, M.4
  • 10
    • 84927966184 scopus 로고    scopus 로고
    • Instruments and methods in outdoor thermal comfort studies—the need for standardization
    • Johansson E, Thorsson S, Emmanuel R, Kruger E (2014) Instruments and methods in outdoor thermal comfort studies—the need for standardization. Urban climate (in printing).
    • (2014) Urban climate
    • Johansson, E.1    Thorsson, S.2    Emmanuel, R.3    Kruger, E.4
  • 11
    • 33750627633 scopus 로고    scopus 로고
    • Spatial variability of both turbulent fluxes and temperature profiles in an urban roughness layer
    • Kanda M, Moriwaki R, Kasamatsu F (2006) Spatial variability of both turbulent fluxes and temperature profiles in an urban roughness layer. Bound-Layer Meteorol 121:339–350
    • (2006) Bound-Layer Meteorol , vol.121 , pp. 339-350
    • Kanda, M.1    Moriwaki, R.2    Kasamatsu, F.3
  • 12
    • 65249132892 scopus 로고    scopus 로고
    • Modification and miniaturization of Thermochron iButtons for surgical implantation into small animals
    • Lovegrove BG (2009) Modification and miniaturization of Thermochron iButtons for surgical implantation into small animals. J Comp Physiol B 179:451–458
    • (2009) J Comp Physiol B , vol.179 , pp. 451-458
    • Lovegrove, B.G.1
  • 13
    • 84939918710 scopus 로고    scopus 로고
    • Nakayoshi M, Kanda K, de Dear R (submitted) Globe anemo-radiometer. The above unpublished paper is uploaded in the following link for our reviewers.
    • Nakayoshi M, Kanda K, de Dear R (submitted) Globe anemo-radiometer. The above unpublished paper is uploaded in the following link for our reviewers. https://dl.dropboxusercontent.com/u/76785677/GAR_Nakayoshi_et_al.pdf
  • 15
    • 84878144298 scopus 로고    scopus 로고
    • Outdoor thermal sensation of pedestrians in a Mediterranean climate and a comparison with UTCI
    • Pantavou K, Theoharatos G, Santamouris M, Asimakopoulos D (2013) Outdoor thermal sensation of pedestrians in a Mediterranean climate and a comparison with UTCI. Build Environ 66:82–95
    • (2013) Build Environ , vol.66 , pp. 82-95
    • Pantavou, K.1    Theoharatos, G.2    Santamouris, M.3    Asimakopoulos, D.4
  • 16
    • 0037400604 scopus 로고    scopus 로고
    • A field study of thermal comfort in outdoor and semi-outdoor environments in subtropical Sydney Australia
    • Spagnolo J, de Dear R (2003) A field study of thermal comfort in outdoor and semi-outdoor environments in subtropical Sydney Australia. Build Environ 38:721–738
    • (2003) Build Environ , vol.38 , pp. 721-738
    • Spagnolo, J.1    de Dear, R.2
  • 17
    • 4444364015 scopus 로고    scopus 로고
    • Representative air temperature of thermally heterogeneous urban areas using the measured pressure gradient
    • Sugawara H, Narita K, Mikami T (2004) Representative air temperature of thermally heterogeneous urban areas using the measured pressure gradient. J Appl Meteorol 43:1168–1179
    • (2004) J Appl Meteorol , vol.43 , pp. 1168-1179
    • Sugawara, H.1    Narita, K.2    Mikami, T.3
  • 18
    • 34548651806 scopus 로고    scopus 로고
    • Thermal comfort and outdoor activity in Japanese urban public places
    • Thorsson S, Honjo T, Lindberg F, Eliasson I, Lim E-M (2007a) Thermal comfort and outdoor activity in Japanese urban public places. Environ Behav 39:660–684
    • (2007) Environ Behav , vol.39 , pp. 660-684
    • Thorsson, S.1    Honjo, T.2    Lindberg, F.3    Eliasson, I.4    Lim, E.-M.5
  • 19
    • 34548714506 scopus 로고    scopus 로고
    • Different methods for estimating the mean radiant temperature in an outdoor urban setting
    • Thorsson S, Lindberg F, Eliasson I, Holmer B (2007b) Different methods for estimating the mean radiant temperature in an outdoor urban setting. Int J Climatol 27:1983–1993
    • (2007) Int J Climatol , vol.27 , pp. 1983-1993
    • Thorsson, S.1    Lindberg, F.2    Eliasson, I.3    Holmer, B.4
  • 20
    • 0004143242 scopus 로고
    • The measurement of radiant heat in relation to human comfort
    • Vennon HM (1932) The measurement of radiant heat in relation to human comfort. J Ind Hyg 14:95–111
    • (1932) J Ind Hyg , vol.14 , pp. 95-111
    • Vennon, H.M.1