-
1
-
-
34247220447
-
Submillimeter total-body murine imaging with U-SPECT-I
-
Vastenhouw, B. & F. Beekman (2007). “Submillimeter total-body murine imaging with U-SPECT-I”, Journal of Nuclear Medicine 48(3): 487-493.
-
(2007)
Journal of Nuclear Medicine
, vol.48
, Issue.3
, pp. 487-493
-
-
Vastenhouw, B.1
Beekman, F.2
-
2
-
-
63849284181
-
U-SPECT-II: An ultra-high-resolution device for molecular small-animal imaging
-
Frans, van der Have, B. Vastenhouw, R. M. Ramakers et al. (2009). “U-SPECT-II: An ultra-high-resolution device for molecular small-animal imaging”, Journal of Nuclear Medicine 50(4): 599-605.
-
(2009)
Journal of Nuclear Medicine
, vol.50
, Issue.4
, pp. 599-605
-
-
Van der Frans, H.1
Vastenhouw, B.2
Ramakers, R.M.3
-
4
-
-
31844444997
-
SemiSPECT: A small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays
-
Hyunki, K., L. R. Furenlid & M. J. Crawford et al. (2006). “SemiSPECT: A small-animal single-photon emission computed tomography (SPECT) imager based on eight cadmium zinc telluride (CZT) detector arrays”, Medical Physics 33(2): 465-474.
-
(2006)
Medical Physics
, vol.33
, Issue.2
, pp. 465-474
-
-
Hyunki, K.1
Furenlid, L.R.2
Crawford, M.J.3
-
5
-
-
59649102711
-
An ultrahigh resolution SPECT system for I-125 mouse brain imaging studies
-
Meng, L. J., G. Fu, et al. (2009). “An ultrahigh resolution SPECT system for I-125 mouse brain imaging studies”, Nuclear Instruments and Methods in Physics Research A 600: 498-505.
-
(2009)
Nuclear Instruments and Methods in Physics Research A
, vol.600
, pp. 498-505
-
-
Meng, L.J.1
Fu, G.2
-
6
-
-
77951202804
-
SPECT mouse imaging on a hybrid micro-PET/SPECT system
-
Ma, T., R. Yao, et al. (2008). “SPECT mouse imaging on a hybrid micro-PET/SPECT system”, The Journal of Nuclear Medicine 49: 119.
-
(2008)
The Journal of Nuclear Medicine
, vol.49
, pp. 119
-
-
Ma, T.1
Yao, R.2
-
7
-
-
48149094741
-
Determination of geometrical parameters for slit-slat SPECT imaging on MicroPET
-
Ma, T., R. Yao, Y. Shao & R. Zhou (2007). “Determination of geometrical parameters for slit-slat SPECT imaging on MicroPET”, IEEE Nuclear Science Symposium Conference Record 6: 4285-4288.
-
(2007)
IEEE Nuclear Science Symposium Conference Record
, vol.6
, pp. 4285-4288
-
-
Ma, T.1
Yao, R.2
Shao, Y.3
Zhou, R.4
-
8
-
-
33747869067
-
SPECT system analysis modeling method based on Boltzmann transfer equation
-
Ma, T. & Y. Jin (2006). “SPECT system analysis modeling method based on Boltzmann transfer equation”, High Energy Physics and Nuclear Physics 30(8): 806-811.
-
(2006)
High Energy Physics and Nuclear Physics
, vol.30
, Issue.8
, pp. 806-811
-
-
Ma, T.1
Jin, Y.2
-
9
-
-
33746810976
-
High-resolution SPECT for small-animal imaging
-
Qi, Y. (2006). “High-resolution SPECT for small-animal imaging”, Nuclear Science and Techniques: 17: 164-169.
-
(2006)
Nuclear Science and Techniques
, vol.17
, pp. 164-169
-
-
Qi, Y.1
-
12
-
-
0016922847
-
Maximum a posteriori estimation of position in scintillation cameras
-
Gray, R. M. & A. Macovski (1976). “Maximum a posteriori estimation of position in scintillation cameras”, IEEE Transactions on Nuclear Science 23: 849-852.
-
(1976)
IEEE Transactions on Nuclear Science
, vol.23
, pp. 849-852
-
-
Gray, R.M.1
Macovski, A.2
-
13
-
-
0024611927
-
Experimental evaluation of a modular Scintillation Camera for SPECT
-
Regers, W. L. (1989). “Experimental evaluation of a modular Scintillation Camera for SPECT”, IEEE Transactions on Nuclear Science 36: 1122-1126.
-
(1989)
IEEE Transactions on Nuclear Science
, vol.36
, pp. 1122-1126
-
-
Regers, W.L.1
-
14
-
-
0034204675
-
Implementation of ML based positioning algorithms for scintillation cameras
-
Joung, J., et al. (2000). “Implementation of ML based positioning algorithms for scintillation cameras”, IEEE Transactions on Nuclear Science 47(3): 1104-1111.
-
(2000)
IEEE Transactions on Nuclear Science
, vol.47
, Issue.3
, pp. 1104-1111
-
-
Joung, J.1
-
16
-
-
0036668834
-
Analytic determination of the pinhole collimator’s point-spread function and RMS resolution with penetration
-
Metzler, S., J. Bowsher, K. Greer & R. Jaszczak (2002). “Analytic determination of the pinhole collimator’s point-spread function and RMS resolution with penetration”, IEEE Transactions on Medical Imaging 21(8): 878-887.
-
(2002)
IEEE Transactions on Medical Imaging
, vol.21
, Issue.8
, pp. 878-887
-
-
Metzler, S.1
Bowsher, J.2
Greer, K.3
Jaszczak, R.4
-
17
-
-
0035413309
-
Analytic determination of pinhole collimator sensitivity with penetration
-
Metzler, S., J. Bowsher, M. Smith & R. Jaszczak (2001). “Analytic determination of pinhole collimator sensitivity with penetration”, IEEE Transactions on Medical Imaging 20(8): 730-741.
-
(2001)
IEEE Transactions on Medical Imaging
, vol.20
, Issue.8
, pp. 730-741
-
-
Metzler, S.1
Bowsher, J.2
Smith, M.3
Jaszczak, R.4
-
19
-
-
0001169360
-
On the determination of functions from their integrals along certain manifolds (Translated)
-
Radon, J. (1917). “On the determination of functions from their integrals along certain manifolds (translated)”, Ber. Verbhandl. Sachs. Akad. Wiss. Leipzig Math-Phys 69: 262-277.
-
(1917)
Ber. Verbhandl. Sachs. Akad. Wiss. Leipzig Math-Phys
, vol.69
, pp. 262-277
-
-
Radon, J.1
-
22
-
-
0029521071
-
A unified analysis of exact methods of inverting the 2D exponential radon transform, with implications for noise control in SPECT
-
Metz, C. E. & X. C. Pan (1995). “A unified analysis of exact methods of inverting the 2D exponential radon transform, with implications for noise control in SPECT”, IEEE Transactions on Medical Imaging 14: 643-658.
-
(1995)
IEEE Transactions on Medical Imaging
, vol.14
, pp. 643-658
-
-
Metz, C.E.1
Pan, X.C.2
-
24
-
-
0027659307
-
A general cone-beam reconstruction algorithm
-
Wang, G., T. H. Lin, P. C. Cheng & D. M. Shinozaki (1993). “A general cone-beam reconstruction algorithm”, IEEE Transactions on Medical Imaging 12: 486-496.
-
(1993)
IEEE Transactions on Medical Imaging
, vol.12
, pp. 486-496
-
-
Wang, G.1
Lin, T.H.2
Cheng, P.C.3
Shinozaki, D.M.4
-
25
-
-
0014905513
-
Algebraic reconstruction techniques (ART) for 3-dimensional electron microscopy and X-ray photography
-
Gordon, R., R. Bender & G. T. Herman (1970). “Algebraic reconstruction techniques (ART) for 3-dimensional electron microscopy and X-ray photography”, Journal of Theoretical Biology 29: 471-481.
-
(1970)
Journal of Theoretical Biology
, vol.29
, pp. 471-481
-
-
Gordon, R.1
Bender, R.2
Herman, G.T.3
-
26
-
-
0029536534
-
A comparison of transform and iterative reconstruction techniques for a volume-imaging PET scanner with a large axial acceptance angle
-
Kinahan, P. E., S. Matej, J. S. Karp, G. T. Herman & R. M. Lewitt (1995). “A comparison of transform and iterative reconstruction techniques for a volume-imaging PET scanner with a large axial acceptance angle”, IEEE Transactions on Nuclear Science 42: 2281-2287.
-
(1995)
IEEE Transactions on Nuclear Science
, vol.42
, pp. 2281-2287
-
-
Kinahan, P.E.1
Matej, S.2
Karp, J.S.3
Herman, G.T.4
Lewitt, R.M.5
-
27
-
-
0028700063
-
Accelerated image reconstruction using ordered subsets of projection data
-
Hudson, H. M. & R. S. Larkin (1994). “Accelerated image reconstruction using ordered subsets of projection data”, IEEE Transactions on Medical Imaging 13: 601-609.
-
(1994)
IEEE Transactions on Medical Imaging
, vol.13
, pp. 601-609
-
-
Hudson, H.M.1
Larkin, R.S.2
-
29
-
-
0031972212
-
Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT
-
Lalush, D. S. & B. M. W. Tsui (1998). “Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT”, Physics in Medicine and Biology 43(4): 875-886.
-
(1998)
Physics in Medicine and Biology
, vol.43
, Issue.4
, pp. 875-886
-
-
Lalush, D.S.1
Tsui, B.M.W.2
-
30
-
-
0026532033
-
Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in 3 dimensions
-
Liang, Z., T. G. Turkington, D. R. Gilland, R. J. Jaszczak & R. E. Coleman (1992). “Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in 3 dimensions”, Physics in Medicine and Biology 37: 587-603.
-
(1992)
Physics in Medicine and Biology
, vol.37
, pp. 587-603
-
-
Liang, Z.1
Turkington, T.G.2
Gilland, D.R.3
Jaszczak, R.J.4
Coleman, R.E.5
-
31
-
-
0038743236
-
An overview of attenuation and scatter correction of planar and SPECT data for dosimetry studies
-
King, M. & T. Farncombe (2003). “An overview of attenuation and scatter correction of planar and SPECT data for dosimetry studies”, Cancer biotherapy and radiopharmaceuticals 18: 181-190.
-
(2003)
Cancer Biotherapy and Radiopharmaceuticals
, vol.18
, pp. 181-190
-
-
King, M.1
Farncombe, T.2
-
32
-
-
0018983328
-
Physical factors affecting quantitative measurements using camera-based single photonemission computed-tomography (SPECT)
-
Jaszczak, R. J., R. E. Coleman & F. R. Whitehead (1981). “Physical factors affecting quantitative measurements using camera-based single photonemission computed-tomography (SPECT)”, IEEE Transactions on Nuclear Science 28: 69-80.
-
(1981)
IEEE Transactions on Nuclear Science
, vol.28
, pp. 69-80
-
-
Jaszczak, R.J.1
Coleman, R.E.2
Whitehead, F.R.3
-
33
-
-
0029119748
-
Quantitative SPECT imaging—a review and recommendations by the focus committee of the Society of Nuclear Medicine Computer and Instrumentation Council
-
Rosenthal, M. S., J. Cullom, W. Hawkins, S. C.Moore, B. M. W. Tsui & M. Yester (1995). “Quantitative SPECT imaging—a review and recommendations by the focus committee of the Society of Nuclear Medicine Computer and Instrumentation Council”, The Journal of Nuclear Medicine 36: 1489-1513.
-
(1995)
The Journal of Nuclear Medicine
, vol.36
, pp. 1489-1513
-
-
Rosenthal, M.S.1
Cullom, J.2
Hawkins, W.3
Moore, S.C.4
Tsui, B.M.W.5
Yester, M.6
-
34
-
-
0027649005
-
Noise properties of filtered backprojection and ML-EM reconstructed emission tomographic images
-
Wilson, D. W. & B. M. W. Tsui (1993). “Noise properties of filtered backprojection and ML-EM reconstructed emission tomographic images”, IEEE Transactions on Nuclear Science 40: 1198-1203.
-
(1993)
IEEE Transactions on Nuclear Science
, vol.40
, pp. 1198-1203
-
-
Wilson, D.W.1
Tsui, B.M.W.2
-
37
-
-
0028224395
-
The importance and implementation of accurate 3D compensation methods for quantitative SPECT
-
Tsui, B. M. W., E. C. Frey, X. Zhao, D. S. Lalush, R. E. Johnston & W. H. McCartney (1994). “The importance and implementation of accurate 3D compensation methods for quantitative SPECT”, Physics in Medicine and Biology 39: 509-530.
-
(1994)
Physics in Medicine and Biology
, vol.39
, pp. 509-530
-
-
Tsui, B.M.W.1
Frey, E.C.2
Zhao, X.3
Lalush, D.S.4
Johnston, R.E.5
McCartney, W.H.6
-
38
-
-
0028818273
-
A transmission-map based scatter correction technique for SPECT in inhomogeneous-media
-
Welch, A., G. T. Gullberg, P. E. Christian, F. L. Datz & T. Morgan (1995). “A transmission-map based scatter correction technique for SPECT in inhomogeneous-media”, Medical Physics 22: 1627-1635.
-
(1995)
Medical Physics
, vol.22
, pp. 1627-1635
-
-
Welch, A.1
Gullberg, G.T.2
Christian, P.E.3
Datz, F.L.4
Morgan, T.5
-
39
-
-
0019526041
-
Analysis of SPECT including scatter and attenuation using sophisticated Monte-Carlo modeling methods
-
Beck, J. W., R. J. Jaszczak, R. E. Coleman, C. F. Starmer & L. W. Nolte (1982). “Analysis of SPECT including scatter and attenuation using sophisticated Monte-Carlo modeling methods”, IEEE Transactions on Nuclear Science 29: 506-511.
-
(1982)
IEEE Transactions on Nuclear Science
, vol.29
, pp. 506-511
-
-
Beck, J.W.1
Jaszczak, R.J.2
Coleman, R.E.3
Starmer, C.F.4
Nolte, L.W.5
-
40
-
-
0033781494
-
Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography
-
Noo, F., R. Clackdoyle, et al. (2000). “Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography”, Physics in Medicine and Biology 45(11): 3489-3508.
-
(2000)
Physics in Medicine and Biology
, vol.45
, Issue.11
, pp. 3489-3508
-
-
Noo, F.1
Clackdoyle, R.2
-
41
-
-
0034764479
-
Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates
-
Karolczak, M., S. Schaller, et al. (2001). “Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates”, Medical Physics 28(10): 2050-2069.
-
(2001)
Medical Physics
, vol.28
, Issue.10
, pp. 2050-2069
-
-
Karolczak, M.1
Schaller, S.2
-
42
-
-
0037767575
-
Characterization of pinhole SPECT acquisition geometry
-
Bequé, D., J. Nuyts, et al. (2003). “Characterization of pinhole SPECT acquisition geometry”, IEEE Transactions on Medical Imaging 22(5): 599-612.
-
(2003)
IEEE Transactions on Medical Imaging
, vol.22
, Issue.5
, pp. 599-612
-
-
Bequé, D.1
Nuyts, J.2
-
43
-
-
33847792326
-
Pinhole SPECT with different data acquisition geometries: Usefulness of unified projection operators in homogeneous coordinates
-
Wang, Y. & B. M. W. Tsui (2007). “Pinhole SPECT with different data acquisition geometries: usefulness of unified projection operators in homogeneous coordinates”, IEEE Transactions on Medical Imaging 26(3): 298-308.
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.3
, pp. 298-308
-
-
Wang, Y.1
Tsui, B.M.W.2
|