메뉴 건너뛰기




Volumn 35, Issue 3, 2015, Pages 521-526

Evaluation of cerebrovascular impedance and wave reflection in mouse by ultrasound

Author keywords

cerebrovascular reactivity; hypercapnia; impedance; mice; reflection; ultrasound

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTERY COMPLIANCE; ARTICLE; BRAIN BLOOD FLOW; CEREBROVASCULAR IMPEDANCE; CONTROLLED STUDY; HEMODYNAMICS; HYPERCAPNIA; IMPEDANCE; INTERNAL CAROTID ARTERY; LEFT COMMON CAROTID ARTERY; MALE; MEASUREMENT; MICROVASCULATURE; MOUSE; NONHUMAN; PRIORITY JOURNAL; PULSE WAVE; ULTRASOUND; VASCULAR RESISTANCE; WAVEFORM; ANIMAL; BRAIN CIRCULATION; C57BL MOUSE; COMMON CAROTID ARTERY; ECHOGRAPHY; PATHOPHYSIOLOGY; PHYSIOLOGY;

EID: 84938508778     PISSN: 07438346     EISSN: 14765543     Source Type: Journal    
DOI: 10.1038/jcbfm.2014.229     Document Type: Article
Times cited : (15)

References (38)
  • 2
    • 33749014907 scopus 로고    scopus 로고
    • Age-related changes in carotid artery flow and pressure pulses: Possible implications for cerebral microvascular disease
    • Hirata K, Yaginuma T, O'Rourke MF, Kawakami M. Age-related changes in carotid artery flow and pressure pulses: possible implications for cerebral microvascular disease. Stroke 2006; 37: 2552-2556.
    • (2006) Stroke , vol.37 , pp. 2552-2556
    • Hirata, K.1    Yaginuma, T.2    O'Rourke, M.F.3    Kawakami, M.4
  • 6
    • 84891749685 scopus 로고    scopus 로고
    • Impaired cerebral autoregulation and vasomotor reactivity in sporadic Alzheimer's disease
    • den Abeelen AS, Lagro J, van Beek AH, Claassen JA. Impaired cerebral autoregulation and vasomotor reactivity in sporadic Alzheimer's disease. Curr Alzheimer Res 2014; 11: 11-17.
    • (2014) Curr Alzheimer Res , vol.11 , pp. 11-17
    • Den Abeelen, A.S.1    Lagro, J.2    Van Beek, A.H.3    Claassen, J.A.4
  • 7
    • 0018826031 scopus 로고
    • Aortic input impedance in normal man: Relationship to pressure wave forms
    • Murgo JP, Westerhof N, Giolma JP, Altobelli SA. Aortic input impedance in normal man: relationship to pressure wave forms. Circulation 1980; 62: 105-116.
    • (1980) Circulation , vol.62 , pp. 105-116
    • Murgo, J.P.1    Westerhof, N.2    Giolma, J.P.3    Altobelli, S.A.4
  • 9
    • 2942744379 scopus 로고    scopus 로고
    • Feasibility of routine pulmonary arterial impedance measurements in pulmonary hypertension
    • Huez S, Brimioulle S, Naeije R, Vachiery JL. Feasibility of routine pulmonary arterial impedance measurements in pulmonary hypertension. Chest 2004; 125: 2121-2128.
    • (2004) Chest , vol.125 , pp. 2121-2128
    • Huez, S.1    Brimioulle, S.2    Naeije, R.3    Vachiery, J.L.4
  • 10
    • 36849011710 scopus 로고    scopus 로고
    • Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension
    • Hunter KS, Lee PF, Lanning CJ, Ivy DD, Kirby KS, Claussen LR et al. Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension. Am Heart J 2008; 155: 166-174.
    • (2008) Am Heart J , vol.155 , pp. 166-174
    • Hunter, K.S.1    Lee, P.F.2    Lanning, C.J.3    Ivy, D.D.4    Kirby, K.S.5    Claussen, L.R.6
  • 11
    • 84866975306 scopus 로고    scopus 로고
    • Doppler changes in the vertebral, middle cerebral, and umbilical arteries in fetuses delivered after 34 weeks: Relationship to severity of growth restriction
    • Morales Rosello J, Hervas Marin D, Fillol Crespo M, Perales Marin A. Doppler changes in the vertebral, middle cerebral, and umbilical arteries in fetuses delivered after 34 weeks: relationship to severity of growth restriction. Prenat Diagn 2012; 32: 960-967.
    • (2012) Prenat Diagn , vol.32 , pp. 960-967
    • Morales Rosello, J.1    Hervas Marin, D.2    Fillol Crespo, M.3    Perales Marin, A.4
  • 12
    • 0033755380 scopus 로고    scopus 로고
    • Use of transcranial doppler ultrasound to predict outcome in patients with intracranial large-Artery occlusive disease
    • Wong KS, Li H, Chan YL, Ahuja A, Lam WW, Wong A et al. Use of transcranial Doppler ultrasound to predict outcome in patients with intracranial large-Artery occlusive disease. Stroke 2000; 31: 2641-2647.
    • (2000) Stroke , vol.31 , pp. 2641-2647
    • Wong, K.S.1    Li, H.2    Chan, Y.L.3    Ahuja, A.4    Lam, W.W.5    Wong, A.6
  • 13
    • 0026496365 scopus 로고
    • Noninvasive determination of aortic input impedance and external left ventricular power output: A validation and repeatability study of a new technique
    • Kelly R, Fitchett D. Noninvasive determination of aortic input impedance and external left ventricular power output: a validation and repeatability study of a new technique. J Am Coll Cardiol 1992; 20: 952-963.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 952-963
    • Kelly, R.1    Fitchett, D.2
  • 14
    • 33644875186 scopus 로고    scopus 로고
    • Cross-sectional relations of peripheral microvascular function, cardiovascular disease risk factors, and aortic stiffness: The framingham heart study
    • Mitchell GF, Vita JA, Larson MG, Parise H, Keyes MJ, Warner E et al. Cross-sectional relations of peripheral microvascular function, cardiovascular disease risk factors, and aortic stiffness: the Framingham Heart Study. Circulation 2005; 112: 3722-3728.
    • (2005) Circulation , vol.112 , pp. 3722-3728
    • Mitchell, G.F.1    Vita, J.A.2    Larson, M.G.3    Parise, H.4    Keyes, M.J.5    Warner, E.6
  • 15
    • 0033858009 scopus 로고    scopus 로고
    • Relationship between the pressure and diameter of the carotid artery in humans
    • Sugawara M, Niki K, Furuhata H, Ohnishi S, Suzuki S. Relationship between the pressure and diameter of the carotid artery in humans. Heart Vessels. 2000; 15: 49-51.
    • (2000) Heart Vessels , vol.15 , pp. 49-51
    • Sugawara, M.1    Niki, K.2    Furuhata, H.3    Ohnishi, S.4    Suzuki, S.5
  • 16
  • 18
    • 84880255152 scopus 로고    scopus 로고
    • A chronic scheme of cranial window preparation to study pial vascular reactivity in murine cerebral malaria
    • Ong PK, Meays D, Frangos JA, Carvalho LJ. A chronic scheme of cranial window preparation to study pial vascular reactivity in murine cerebral malaria. Microcirculation 2013; 20: 394-404.
    • (2013) Microcirculation , vol.20 , pp. 394-404
    • Ong, P.K.1    Meays, D.2    Frangos, J.A.3    Carvalho, L.J.4
  • 22
    • 75749128640 scopus 로고    scopus 로고
    • Blood-oxygen level dependent mri measures of cerebrovascular reactivity using a controlled respiratory challenge: Reproducibility and gender differences
    • Kassner A, Winter JD, Poublanc J, Mikulis DJ, Crawley AP. Blood-oxygen level dependent MRI measures of cerebrovascular reactivity using a controlled respiratory challenge: reproducibility and gender differences. J Magn Reson Imaging 2010; 31: 298-304.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 298-304
    • Kassner, A.1    Winter, J.D.2    Poublanc, J.3    Mikulis, D.J.4    Crawley, A.P.5
  • 23
    • 0034044082 scopus 로고    scopus 로고
    • Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement
    • Boese JM, Bock M, Schoenberg SO, Schad LR. Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement. Phys Med Biol 2000; 45: 1703-1713.
    • (2000) Phys Med Biol , vol.45 , pp. 1703-1713
    • Boese, J.M.1    Bock, M.2    Schoenberg, S.O.3    Schad, L.R.4
  • 24
    • 0034892079 scopus 로고    scopus 로고
    • Determination of wave speed and wave separation in the arteries
    • Khir AW, O'Brien A, Gibbs JS, Parker KH. Determination of wave speed and wave separation in the arteries. J Biomech 2001; 34: 1145-1155.
    • (2001) J Biomech , vol.34 , pp. 1145-1155
    • Khir, A.W.1    O'Brien, A.2    Gibbs, J.S.3    Parker, K.H.4
  • 25
    • 0036204320 scopus 로고    scopus 로고
    • Estimation of local aortic elastic properties with mri
    • Vulliemoz S, Stergiopulos N, Meuli R. Estimation of local aortic elastic properties with MRI. Magn Reson Med 2002; 47: 649-654.
    • (2002) Magn Reson Med , vol.47 , pp. 649-654
    • Vulliemoz, S.1    Stergiopulos, N.2    Meuli, R.3
  • 26
    • 84879064958 scopus 로고    scopus 로고
    • Least squares revisited
    • Glaister P. Least squares revisited. Math Gazette 2001; 85, S 104-107.
    • (2001) Math Gazette , vol.85 , Issue.S , pp. 104-107
    • Glaister, P.1
  • 28
    • 0018397141 scopus 로고
    • The calculation of forward and backward waves in the arterial system
    • Laxminarayan S. The calculation of forward and backward waves in the arterial system. Med Biol Eng Comput 1979; 17: 130.
    • (1979) Med Biol Eng Comput , vol.17 , pp. 130
    • Laxminarayan, S.1
  • 29
    • 0022765180 scopus 로고
    • Time domain resolution of forward and reflected waves in the aorta
    • Li JK. Time domain resolution of forward and reflected waves in the aorta. IEEE Trans Biomed Eng 1986; 33: 783-785.
    • (1986) IEEE Trans Biomed Eng , vol.33 , pp. 783-785
    • Li, J.K.1
  • 30
    • 73149090111 scopus 로고    scopus 로고
    • High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent
    • Howles GP, Ghaghada KB, Qi Y, Mukundan S, Jr, Johnson GA. High-resolution magnetic resonance angiography in the mouse using a nanoparticle blood-pool contrast agent. Magn Reson Med 2009; 62: 1447-1456.
    • (2009) Magn Reson Med , vol.62 , pp. 1447-1456
    • Howles, G.P.1    Ghaghada, K.B.2    Qi, Y.3    Mukundan, S.4    Johnson, G.A.5
  • 31
    • 0036584937 scopus 로고    scopus 로고
    • Cardiovascular flow measurement with phase-contrast mr imaging: Basic facts and implementation
    • Lotz J, Meier C, Leppert A, Galanski M. Cardiovascular flow measurement with phase-contrast MR imaging: basic facts and implementation.Radiographics 2002; 22: 651-671.
    • (2002) Radiographics , vol.22 , pp. 651-671
    • Lotz, J.1    Meier, C.2    Leppert, A.3    Galanski, M.4
  • 32
    • 0030797924 scopus 로고    scopus 로고
    • Assessment of cerebral blood flow and co2 reactivity after controlled cortical impact by perfusion magnetic resonance imaging using arterial spin-labeling in rats
    • Forbes ML, Hendrich KS, Kochanek PM, Williams DS, Schiding JK, Wisniewski SR et al. Assessment of cerebral blood flow and CO2 reactivity after controlled cortical impact by perfusion magnetic resonance imaging using arterial spin-labeling in rats. J Cereb Blood Flow Metab 1997; 17: 865-874.
    • (1997) J Cereb Blood Flow Metab , vol.17 , pp. 865-874
    • Forbes, M.L.1    Hendrich, K.S.2    Kochanek, P.M.3    Williams, D.S.4    Schiding, J.K.5    Wisniewski, S.R.6
  • 33
    • 0034997207 scopus 로고    scopus 로고
    • Perfusion imaging using dynamic arterial spin labeling (dasl)
    • Barbier EL, Silva AC, Kim SG, Koretsky AP. Perfusion imaging using dynamic arterial spin labeling (DASL). Magn Reson Med 2001; 45: 1021-1029.
    • (2001) Magn Reson Med , vol.45 , pp. 1021-1029
    • Barbier, E.L.1    Silva, A.C.2    Kim, S.G.3    Koretsky, A.P.4
  • 34
    • 84864153728 scopus 로고    scopus 로고
    • Differential blood flow responses to co(2) in human internal and external carotid and vertebral arteries
    • Sato K, Sadamoto T, Hirasawa A, Oue A, Subudhi AW, Miyazawa T et al. Differential blood flow responses to CO(2) in human internal and external carotid and vertebral arteries. J Physiol 2012; 590: 3277-3290.
    • (2012) J Physiol , vol.590 , pp. 3277-3290
    • Sato, K.1    Sadamoto, T.2    Hirasawa, A.3    Oue, A.4    Subudhi, A.W.5    Miyazawa, T.6
  • 35
    • 33745968478 scopus 로고    scopus 로고
    • In vivo x-ray angiography in the mouse brain using synchrotron radiation
    • Kidoguchi K, Tamaki M, Mizobe T, Koyama J, Kondoh T, Kohmura E et al. In vivo X-ray angiography in the mouse brain using synchrotron radiation. Stroke 2006; 37: 1856-1861.
    • (2006) Stroke , vol.37 , pp. 1856-1861
    • Kidoguchi, K.1    Tamaki, M.2    Mizobe, T.3    Koyama, J.4    Kondoh, T.5    Kohmura, E.6
  • 37
    • 84898989022 scopus 로고    scopus 로고
    • Wave reflection leads to over-And underestimation of local wave speed by the pu-And qa-loop methods: Theoretical basis and solution to the problem
    • Segers P, Swillens A, Taelman L, Vierendeels J. Wave reflection leads to over-And underestimation of local wave speed by the PU-And QA-loop methods: theoretical basis and solution to the problem. Physiol Meas 2014; 35: 847-861.
    • (2014) Physiol Meas , vol.35 , pp. 847-861
    • Segers, P.1    Swillens, A.2    Taelman, L.3    Vierendeels, J.4
  • 38
    • 0021928948 scopus 로고
    • Contribution of internal and external carotid beds to common carotid artery input impedance in the dog
    • Taylor DE, Tukmachi ES. Contribution of internal and external carotid beds to common carotid artery input impedance in the dog. Q J Exp Physiol 1985; 70: 177-187.
    • (1985) Q J Exp Physiol , vol.70 , pp. 177-187
    • Taylor, D.E.1    Tukmachi, E.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.