Volumn 858, Issue , 2015, Pages 39-46

Variability of transcutaneous oxygen and carbon dioxide pressure measurements associated with sensor location

Author keywords

Blood gas monitoring; Body mass index; Electrode location; Healthy subjects; Transcutaneous carbon dioxide tension; Transcutaneous oxygen tension

Indexed keywords

ADULT; ANATOMIC LANDMARK; ARTERIAL CARBON DIOXIDE TENSION; ARTERIAL OXYGEN SATURATION; ARTERIAL OXYGEN TENSION; ARTICLE; BLOOD GAS ANALYSIS; BLOOD OXYGENATION; BODY COMPOSITION; BODY SURFACE; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; CORRELATIONAL STUDY; ELECTRODE; FEMALE; HUMAN; INNER SURFACE OF THE ARM; LATERAL SURFACE OF THE ABDOMEN; MALE; OBESITY; PRIORITY JOURNAL; PULSE OXIMETRY; SECOND INTERCOSTAL SPACE; SENSOR; SENSOR LOCATION; THORAX; TRANSCUTANEOUS CARBON DIOXIDE MONITORING; TRANSCUTANEOUS OXYGEN MONITORING; ABDOMEN; ARM; BLOOD; DEVICES; DIAGNOSTIC USE; IMPEDANCE; PHYSIOLOGIC MONITORING; PHYSIOLOGY; STANDARDS;

EID: 84938500483     PISSN: 00652598     EISSN: 22148019     Source Type: Book Series    
DOI: 10.1007/5584_2015_126     Document Type: Article
Times cited : (10)

References (23)
  • 1
    • 16844370763 scopus 로고    scopus 로고
    • Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients
    • Bernet-Buettiker V, Ugarte MJ, Frey B, Hug MI, Baenziger O, Weiss M (2005) Evaluation of a new combined transcutaneous measurement of PCO2/pulse oximetry oxygen saturation ear sensor in newborn patients. Pediatrics 115:e64–e68
    • (2005) Pediatrics , vol.115 , pp. e64-e68
    • Bernet-Buettiker, V.1    Ugarte, M.J.2    Frey, B.3    Hug, M.I.4    Baenziger, O.5    Weiss, M.6
  • 2
    • 0031840878 scopus 로고    scopus 로고
    • Changes in oxygen saturation and transcutaneous carbon dioxide and oxygen levels in patients undergoing fiber optic bronchoscopy
    • Evans EN, Ganeshalingam K, Ebden P (1998) Changes in oxygen saturation and transcutaneous carbon dioxide and oxygen levels in patients undergoing fiber optic bronchoscopy. Respir Med 92:739–742
    • (1998) Respir Med , vol.92 , pp. 739-742
    • Evans, E.N.1    Ganeshalingam, K.2    Ebden, P.3
  • 3
    • 79952281709 scopus 로고    scopus 로고
    • Transcutaneous carbon dioxide in severe COPD patients during bronchoscopic lung volume reduction
    • Fruchter O, Carmi U, Ingenito EP, Refaeli Y, Kramer MR (2011) Transcutaneous carbon dioxide in severe COPD patients during bronchoscopic lung volume reduction. Respir Med 105:602–607
    • (2011) Respir Med , vol.105 , pp. 602-607
    • Fruchter, O.1    Carmi, U.2    Ingenito, E.P.3    Refaeli, Y.4    Kramer, M.R.5
  • 4
    • 63849279518 scopus 로고    scopus 로고
    • Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjects
    • Fuke S, Miyamoto K, Ohira H, Ohira M, Odajima N, Nishimura M (2009) Evaluation of transcutaneous CO2 responses following acute changes in PaCO2 in healthy subjects. Respirology 14:436–442
    • (2009) Respirology , vol.14 , pp. 436-442
    • Fuke, S.1    Miyamoto, K.2    Ohira, H.3    Ohira, M.4    Odajima, N.5    Nishimura, M.6
  • 8
    • 0031594179 scopus 로고    scopus 로고
    • Transcutaneous pCO2 to monitor noninvasive mechanical ventilation in adults: Assessment of a new transcutaneous PCO2 device
    • Janssens JP, Howarth-Frey C, Chevrolet JC, Abajo B, Rochat T (1998) Transcutaneous pCO2 to monitor noninvasive mechanical ventilation in adults: assessment of a new transcutaneous PCO2 device. Chest 113:768–773
    • (1998) Chest , vol.113 , pp. 768-773
    • Janssens, J.P.1    Howarth-Frey, C.2    Chevrolet, J.C.3    Abajo, B.4    Rochat, T.5
  • 11
    • 0025809440 scopus 로고
    • Response characteristics of a dual transcutaneous oxygen/carbon dioxide monitoring system
    • Kesten S, Chapman KR, Rebuck AS (1991) Response characteristics of a dual transcutaneous oxygen/carbon dioxide monitoring system. Chest 99:1211–1215
    • (1991) Chest , vol.99 , pp. 1211-1215
    • Kesten, S.1    Chapman, K.R.2    Rebuck, A.S.3
  • 12
  • 13
    • 33750370315 scopus 로고    scopus 로고
    • Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia
    • Nishiyama T, Nakamura S, Yamashita K (2006) Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia. Eur J Anaesthesiol 12:1049–1054
    • (2006) Eur J Anaesthesiol , vol.12 , pp. 1049-1054
    • Nishiyama, T.1    Nakamura, S.2    Yamashita, K.3
  • 14
    • 0025194090 scopus 로고
    • Transcutaneous PCO2 and PO2: A multicenter study of accuracy
    • Palmisano BW, Seberinghaus JW (1990) Transcutaneous PCO2 and PO2: a multicenter study of accuracy. J Clin Monit 6:189–195
    • (1990) J Clin Monit , vol.6 , pp. 189-195
    • Palmisano, B.W.1    Seberinghaus, J.W.2
  • 15
    • 84868370105 scopus 로고    scopus 로고
    • AARC Clinical Practice Guideline: Transcutaneous monitoring of carbon dioxide and oxygen: 2012
    • Restrepo R, Hirst K, Wittnebel L, Wettstein R (2012) AARC Clinical Practice Guideline: transcutaneous monitoring of carbon dioxide and oxygen: 2012. Respir Care 57:1955–1962
    • (2012) Respir Care , vol.57 , pp. 1955-1962
    • Restrepo, R.1    Hirst, K.2    Wittnebel, L.3    Wettstein, R.4
  • 16
    • 84938491255 scopus 로고    scopus 로고
    • A survey of transcutaneous blood gas monitoring among European neonatal intensive care units
    • Rudiger M, Topfer K, Hammer H, Schmalisch G, Wauer RR (2007) A survey of transcutaneous blood gas monitoring among European neonatal intensive care units. Neonatal Intensive Care 20:37–40
    • (2007) Neonatal Intensive Care , vol.20 , pp. 37-40
    • Rudiger, M.1    Topfer, K.2    Hammer, H.3    Schmalisch, G.4    Wauer, R.R.5
  • 17
    • 24944543851 scopus 로고    scopus 로고
    • Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea
    • Senn O, Clarenbach CF, Kaplan V, Maggiorini M, Bloch KE (2005) Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea. Chest 128:1291–1296
    • (2005) Chest , vol.128 , pp. 1291-1296
    • Senn, O.1    Clarenbach, C.F.2    Kaplan, V.3    Maggiorini, M.4    Bloch, K.E.5
  • 18
    • 84901649152 scopus 로고    scopus 로고
    • A comparison of incidence of hypercapnia in non-obese and morbidly obese peri-operative patients using the SenTec transcutaneous pCO2 monitor
    • Soto RG, Davis M, Faulkner MJ (2014) A comparison of incidence of hypercapnia in non-obese and morbidly obese peri-operative patients using the SenTec transcutaneous pCO2 monitor. J Clin Monit Comput 28:293–298
    • (2014) J Clin Monit Comput , vol.28 , pp. 293-298
    • Soto, R.G.1    Davis, M.2    Faulkner, M.J.3
  • 19
    • 84938521952 scopus 로고    scopus 로고
    • Radiometer Medical ApS, Denmark
    • Thomsen AM (2011) The PtcCO2 handbook. Radiometer Medical ApS, Denmark, p 20
    • (2011) The Ptcco2 Handbook , pp. 20
    • Thomsen, A.M.1
  • 20
    • 85027951941 scopus 로고    scopus 로고
    • End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates
    • Tingay DG, Mun KS, Perkins EJ (2013) End tidal carbon dioxide is as reliable as transcutaneous monitoring in ventilated postsurgical neonates. Arch Dis Child Fetal Neonatal Ed 98:F161–F164
    • (2013) Arch Dis Child Fetal Neonatal Ed , vol.98 , pp. F161-F164
    • Tingay, D.G.1    Mun, K.S.2    Perkins, E.J.3
  • 21
    • 65349189920 scopus 로고    scopus 로고
    • Transcutaneous carbon dioxide monitoring in infants and children
    • Tobias JD (2009) Transcutaneous carbon dioxide monitoring in infants and children. Pediatr Anesth 19:434–444
    • (2009) Pediatr Anesth , vol.19 , pp. 434-444
    • Tobias, J.D.1
  • 22
    • 38549148539 scopus 로고    scopus 로고
    • Transcutaneous oxygen and carbon dioxide tension compared to arterial blood gases in normals
    • Weaver LK (2007) Transcutaneous oxygen and carbon dioxide tension compared to arterial blood gases in normals. Respir Care 52:1490–1496
    • (2007) Respir Care , vol.52 , pp. 1490-1496
    • Weaver, L.K.1
  • 23
    • 0022250145 scopus 로고
    • Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults
    • Wimberley PD, Pedersen KG, Olsson J, Siggaard- Andersen O (1985) Transcutaneous carbon dioxide and oxygen tension measured at different temperatures in healthy adults. Clin Chem 31:1611–1615
    • (1985) Clin Chem , vol.31 , pp. 1611-1615
    • Wimberley, P.D.1    Pedersen, K.G.2    Olsson, J.3    Siggaard- Andersen, O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.