메뉴 건너뛰기




Volumn 42, Issue 7, 2015, Pages 1032-1042

Biodistribution and radiation dosimetry of 82Rb at rest and during peak pharmacological stress in patients referred for myocardial perfusion imaging

Author keywords

82Rb dosimetry; 3D PET; Biodistribution; Myocardial perfusion imaging; PET dosimetry; Radiodosimetry

Indexed keywords

RADIOPHARMACEUTICAL AGENT; RUBIDIUM;

EID: 84937765398     PISSN: 16197070     EISSN: 16197089     Source Type: Journal    
DOI: 10.1007/s00259-015-3028-3     Document Type: Article
Times cited : (32)

References (24)
  • 1
    • 84886260869 scopus 로고    scopus 로고
    • 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology
    • Task Force Members, Montalescot G, Sechtem U, Achenbach S, Andreotti F, Arden C, et al. 2013 ESC guidelines on the management of stable coronary artery disease: the Task Force on the management of stable coronary artery disease of the European Society of Cardiology. Eur Heart J. 2013;34:2949–3003.
    • (2013) Eur Heart J , vol.34 , pp. 2949-3003
    • Task Force Members1    Montalescot, G.2    Sechtem, U.3    Achenbach, S.4    Andreotti, F.5    Arden, C.6
  • 2
    • 84867840857 scopus 로고    scopus 로고
    • Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis
    • PID: 23040573
    • Mc Ardle BA, Dowsley TF, deKemp RA, Wells GA, Beanlands RS. Does rubidium-82 PET have superior accuracy to SPECT perfusion imaging for the diagnosis of obstructive coronary disease? A systematic review and meta-analysis. J Am Coll Cardiol. 2012;60:1828–37.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1828-1837
    • Mc Ardle, B.A.1    Dowsley, T.F.2    deKemp, R.A.3    Wells, G.A.4    Beanlands, R.S.5
  • 3
    • 84890806759 scopus 로고    scopus 로고
    • Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods
    • PID: 23982454
    • Tahari AK, Lee A, Rajaram M, Fukushima K, Lodge MA, Lee BC, et al. Absolute myocardial flow quantification with (82)Rb PET/CT: comparison of different software packages and methods. Eur J Nucl Med Mol Imaging. 2014;41:126–35.
    • (2014) Eur J Nucl Med Mol Imaging , vol.41 , pp. 126-135
    • Tahari, A.K.1    Lee, A.2    Rajaram, M.3    Fukushima, K.4    Lodge, M.A.5    Lee, B.C.6
  • 4
    • 84922560700 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow in absolute terms using (82)Rb PET imaging: the RUBY-10 Study
    • PID: 25306543
    • Nesterov SV, Deshayes E, Sciagrà R, Settimo L, Declerck JM, Pan XB, et al. Quantification of myocardial blood flow in absolute terms using (82)Rb PET imaging: the RUBY-10 Study. JACC Cardiovasc Imaging. 2014;7:1119–27. doi:10.1016/j.jcmg.2014.08.003.
    • (2014) JACC Cardiovasc Imaging , vol.7 , pp. 1119-1127
    • Nesterov, S.V.1    Deshayes, E.2    Sciagrà, R.3    Settimo, L.4    Declerck, J.M.5    Pan, X.B.6
  • 7
    • 0038763576 scopus 로고    scopus 로고
    • Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53)
    • ICRP Publication 80: Radiation dose to patients from radiopharmaceuticals (addendum 2 to ICRP publication 53). Ann ICRP. 1998;28:1–126.
    • (1998) Ann ICRP , vol.28 , pp. 1-126
    • Publication 80, I.C.R.P.1
  • 8
    • 0020452126 scopus 로고
    • Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130
    • COI: 1:CAS:528:DyaL3sXisVWksA%3D%3D, PID: 6982966
    • Kearfott KJ. Radiation absorbed dose estimates for positron emission tomography (PET): K-38, Rb-81, Rb-82, and Cs-130. J Nucl Med. 1982;23:1128–32.
    • (1982) J Nucl Med , vol.23 , pp. 1128-1132
    • Kearfott, K.J.1
  • 9
    • 0029047087 scopus 로고
    • A proposed blood circulation model for Reference Man
    • COI: 1:CAS:528:DyaK2MXntFGlsr4%3D, PID: 7622365
    • Leggett RW, Williams LR. A proposed blood circulation model for Reference Man. Health Phys. 1995;69:187–201.
    • (1995) Health Phys , vol.69 , pp. 187-201
    • Leggett, R.W.1    Williams, L.R.2
  • 10
    • 0141430974 scopus 로고    scopus 로고
    • ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging)
    • PID: 12975245
    • Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–18.
    • (2003) Circulation , vol.108 , pp. 1404-1418
    • Klocke, F.J.1    Baird, M.G.2    Lorell, B.H.3    Bateman, T.M.4    Messer, J.V.5    Berman, D.S.6
  • 11
    • 34047252834 scopus 로고    scopus 로고
    • Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography
    • COI: 1:STN:280:DC%2BD2s%2FjtVyktg%3D%3D, PID: 17228112
    • Klein R, Adler A. Precision-controlled elution of a 82Sr/82Rb generator for cardiac perfusion imaging with positron emission tomography. Phys Med Biol. 2007;52:659–73.
    • (2007) Phys Med Biol , vol.52 , pp. 659-673
    • Klein, R.1    Adler, A.2
  • 12
    • 34247204476 scopus 로고    scopus 로고
    • NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes
    • PID: 17138738
    • Kemp BJ, Kim C, Williams JJ, Ganin A, Lowe VJ. NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. J Nucl Med. 2006;47:1960–7.
    • (2006) J Nucl Med , vol.47 , pp. 1960-1967
    • Kemp, B.J.1    Kim, C.2    Williams, J.J.3    Ganin, A.4    Lowe, V.J.5
  • 13
    • 77449106113 scopus 로고    scopus 로고
    • ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms
    • PID: 19897132
    • Menzel HG, Clement C, DeLuca P. ICRP publication 110. Realistic reference phantoms: an ICRP/ICRU joint effort. A report of adult reference computational phantoms. Ann ICRP. 2009;39:1–164.
    • (2009) Ann ICRP , vol.39 , pp. 1-164
    • Menzel, H.G.1    Clement, C.2    DeLuca, P.3
  • 14
    • 23044470017 scopus 로고    scopus 로고
    • OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine
    • PID: 15937315
    • Stabin MG, Sparks RB, Crowe E. OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–7.
    • (2005) J Nucl Med , vol.46 , pp. 1023-1027
    • Stabin, M.G.1    Sparks, R.B.2    Crowe, E.3
  • 15
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 Recommendations of the International Commission on Radiological Protection
    • ICRP Publication 103: The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 2007;37:1–332.
    • (2007) Ann ICRP , vol.37 , pp. 1-332
    • Publication 103, I.C.R.P.1
  • 16
    • 0025930020 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection. Ann ICRP. 1991;21(1–3):1–201.
    • (1991) Ann ICRP , vol.21 , Issue.1-3 , pp. 1-201
  • 17
    • 78649596228 scopus 로고    scopus 로고
    • Proposed revision to the radiation dosimetry of 82Rb
    • COI: 1:CAS:528:DC%2BC3cXhsVWmsLzN, PID: 21068600
    • Stabin MG. Proposed revision to the radiation dosimetry of 82Rb. Health Phys. 2010;99:811–3.
    • (2010) Health Phys , vol.99 , pp. 811-813
    • Stabin, M.G.1
  • 18
    • 84899442343 scopus 로고    scopus 로고
    • Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats
    • PID: 24620906
    • Duan Y, Lockwood J, Wei L, Hunter C, Soueidan K, Bensimon C, et al. Biodistribution and radiodosimetry of a novel myocardial perfusion tracer 123I-CMICE-013 in healthy rats. EJNMMI Res. 2014;4:16.
    • (2014) EJNMMI Res , vol.4 , pp. 16
    • Duan, Y.1    Lockwood, J.2    Wei, L.3    Hunter, C.4    Soueidan, K.5    Bensimon, C.6
  • 19
    • 84973202937 scopus 로고
    • Radiation dose to patients from radiopharmaceuticals
    • ICRP Publication 53: Radiation dose to patients from radiopharmaceuticals. Ann. ICRP. 1987;18(1–4):1–377.
    • (1987) Ann. ICRP , vol.18 , Issue.1-4 , pp. 1-377
    • Publication 53, I.C.R.P.1
  • 21
    • 84973267519 scopus 로고
    • Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge
    • Ryan JW, Harper PV, Stark VS, Peterson EL, Lathrop KA. Radiation absorbed dose estimates for rubidium-82 determined from in vivo measurements in human subjects. Proceedings of the Fourth International Radiopharmaceutical Dosimetry Symposium, Oak Ridge, Tennessee, 5–8 November 1985. p. 346–58.
    • (1985) Tennessee , vol.5-8 , pp. 346-358
  • 22
    • 23744498066 scopus 로고    scopus 로고
    • EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    • COI: 1:STN:280:DC%2BD2Mzpt1Kjsg%3D%3D, PID: 15909197
    • Hesse B, Tagil K, Cuocolo A, Anagnostopoulos C, Bardies M, Bax J, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–97.
    • (2005) Eur J Nucl Med Mol Imaging , vol.32 , pp. 855-897
    • Hesse, B.1    Tagil, K.2    Cuocolo, A.3    Anagnostopoulos, C.4    Bardies, M.5    Bax, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.