메뉴 건너뛰기




Volumn 204, Issue 6, 2015, Pages W640-W647

Dual-energy MDCT for imaging the renal mass

Author keywords

Dual energy MDCT; Iodine map; Renal cell carcinoma; Renal cyst; Renal mass

Indexed keywords

ARTICLE; CLINICAL PROTOCOL; CONTRAST ENHANCEMENT; DIAGNOSTIC VALUE; DUAL ENERGY MULTIDETECTOR COMPUTED TOMOGRAPHY; EVIDENCE BASED MEDICINE; HEALTH CARE QUALITY; HUMAN; IMAGE ANALYSIS; IMAGE PROCESSING; IMAGING AND DISPLAY; INCIDENTAL FINDING; KIDNEY CYST; KIDNEY INJURY; KIDNEY TUMOR; MATERIAL DECOMPOSITION ANALYSIS; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT POSITIONING; PATIENT SELECTION; PRIORITY JOURNAL; PSEUDOENHANCEMENT; RADIATION ATTENUATION; RADIATION EXPOSURE; RADIOLOGIST; RENOGRAPHY; SINGLE PHASE NEPHROGRAPHIC DUAL ENERGY IMAGING; TUMOR DIAGNOSIS; TUMOR VOLUME; ADULT; DIFFERENTIAL DIAGNOSIS; FEMALE; IMAGE QUALITY; KIDNEY; KIDNEY DISEASE; MALE; MIDDLE AGED; PROCEDURES; RADIOGRAPHY;

EID: 84937718128     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.14.14094     Document Type: Article
Times cited : (56)

References (45)
  • 3
    • 70349565395 scopus 로고    scopus 로고
    • Pitfalls in renal mass evaluation and how to avoid them
    • Israel GM, Bosniak MA. Pitfalls in renal mass evaluation and how to avoid them. RadioGraphics 2008; 28:1325-1338
    • (2008) RadioGraphics , vol.28 , pp. 1325-1338
    • Israel, G.M.1    Bosniak, M.A.2
  • 4
    • 22544471493 scopus 로고    scopus 로고
    • How i do it: Evaluating renal masses
    • Israel GM, Bosniak MA. How I do it: evaluating renal masses. Radiology 2005; 236:441-450
    • (2005) Radiology , vol.236 , pp. 441-450
    • Israel, G.M.1    Bosniak, M.A.2
  • 5
    • 84859493291 scopus 로고    scopus 로고
    • Contemporary imaging of the renal mass
    • Kang SK, Chandarana H. Contemporary imaging of the renal mass. Urol Clin North Am 2012; 39:161-170
    • (2012) Urol Clin North Am , vol.39 , pp. 161-170
    • Kang, S.K.1    Chandarana, H.2
  • 7
    • 0041341835 scopus 로고    scopus 로고
    • Distinction of renal cell carcinomas from high-attenuation renal cysts at portal venous phase contrast-enhanced CT
    • Suh M, Coakley FV, Qayyum A, Yeh BM, Breiman SB, Lu Y. Distinction of renal cell carcinomas from high-attenuation renal cysts at portal venous phase contrast-enhanced CT. Radiology 2003; 228:330-334
    • (2003) Radiology , vol.228 , pp. 330-334
    • Suh, M.1    Coakley, F.V.2    Qayyum, A.3    Yeh, B.M.4    Breiman, S.B.5    Lu, Y.6
  • 8
    • 0345534822 scopus 로고    scopus 로고
    • Delayed CT to evaluate renal masses incidentally discovered at contrastenhanced CT: Demonstration of vascularity with deenhancement
    • Macari M, Bosniak MA. Delayed CT to evaluate renal masses incidentally discovered at contrastenhanced CT: demonstration of vascularity with deenhancement. Radiology 1999; 213:674-680
    • (1999) Radiology , vol.213 , pp. 674-680
    • Macari, M.1    Bosniak, M.A.2
  • 9
    • 2942715232 scopus 로고    scopus 로고
    • Evaluation of small (? 3 cm) renal masses with MDCT: Benefits of thin overlapping reconstructions
    • Jinzaki M, McTavish JD, Zou KH, Judy PF, Silverman SG. Evaluation of small (? 3 cm) renal masses with MDCT: benefits of thin overlapping reconstructions. AJR 2004; 183:223-228
    • (2004) AJR , vol.183 , pp. 223-228
    • Jinzaki, M.1    McTavish, J.D.2    Zou, K.H.3    Judy, P.F.4    Silverman, S.G.5
  • 10
    • 84890080388 scopus 로고    scopus 로고
    • Simple cyst-appearing renal masses at unenhanced CT: Can they be presumed to be benign?
    • O'Connor SD, Silverman SG, Ip IK, Maehara CK, Khorasani R. Simple cyst-appearing renal masses at unenhanced CT: can they be presumed to be benign? Radiology 2013; 269:793-800
    • (2013) Radiology , vol.269 , pp. 793-800
    • O'Connor, S.D.1    Silverman, S.G.2    Ip, I.K.3    Maehara, C.K.4    Khorasani, R.5
  • 11
    • 77956128814 scopus 로고    scopus 로고
    • Renal mass biopsy to guide treatment decisions for small incidental renal tumors: A cost-effectiveness analysis
    • Pandharipande PV, Gervais DA, Hartman RI, et al. Renal mass biopsy to guide treatment decisions for small incidental renal tumors: a cost-effectiveness analysis. Radiology 2010; 256:836-846
    • (2010) Radiology , vol.256 , pp. 836-846
    • Pandharipande, P.V.1    Gervais, D.A.2    Hartman, R.I.3
  • 12
    • 0028834742 scopus 로고
    • The current role of percutaneous biopsy in the evaluation of renal masses
    • Herts BR, Baker ME. The current role of percutaneous biopsy in the evaluation of renal masses. Semin Urol Oncol 1995; 13:254-261
    • (1995) Semin Urol Oncol , vol.13 , pp. 254-261
    • Herts, B.R.1    Baker, M.E.2
  • 13
    • 77649165859 scopus 로고    scopus 로고
    • Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses
    • Leschka S, Stolzmann P, Baumüller S, et al. Performance of dual-energy CT with tin filter technology for the discrimination of renal cysts and enhancing masses. Acad Radiol 2010; 17:526-534
    • (2010) Acad Radiol , vol.17 , pp. 526-534
    • Leschka, S.1    Stolzmann, P.2    Baumüller, S.3
  • 14
    • 84858124994 scopus 로고    scopus 로고
    • Dual energy CT with single-and dual-source scanners: Current applications in evaluating the genitourinary tract
    • Kaza RK, Platt JF, Cohan RH, Caoili EM, Al-Hawary MM, Wasnik A. Dual energy CT with single-and dual-source scanners: current applications in evaluating the genitourinary tract. Radio-Graphics 2012; 32:353-369
    • (2012) Radio-Graphics , vol.32 , pp. 353-369
    • Kaza, R.K.1    Platt, J.F.2    Cohan, R.H.3    Caoili, E.M.4    Al-Hawary, M.M.5    Wasnik, A.6
  • 15
    • 79951948387 scopus 로고    scopus 로고
    • Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent: An experimental phantom study
    • Karlo C, Lauber A, Götti RP, et al. Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent: an experimental phantom study. Eur Radiol 2011; 21:385-392
    • (2011) Eur Radiol , vol.21 , pp. 385-392
    • Karlo, C.1    Lauber, A.2    Götti, R.P.3
  • 16
    • 64249100198 scopus 로고    scopus 로고
    • Dual energy CT iodine overlay technique for characterisation of renal masses as cyst or solid: A phantom feasibility study
    • Brown CL, Hartman RP, Dzyubak OP, et al. Dual energy CT iodine overlay technique for characterisation of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol 2009; 19:1289-1295
    • (2009) Eur Radiol , vol.19 , pp. 1289-1295
    • Brown, C.L.1    Hartman, R.P.2    Dzyubak, O.P.3
  • 17
    • 58949099700 scopus 로고    scopus 로고
    • Dualenergy and dual-source CT: Is there a role in the abdomen and pelvis?
    • Fletcher JG, Takahashi N, Hartman R, et al. Dualenergy and dual-source CT: is there a role in the abdomen and pelvis? Radiol Clin North Am 2009; 47:41-57
    • (2009) Radiol Clin North Am , vol.47 , pp. 41-57
    • Fletcher, J.G.1    Takahashi, N.2    Hartman, R.3
  • 18
    • 77954089654 scopus 로고    scopus 로고
    • Singlephase dual energy CT allows for characterisation of renal masses as benign or malignant
    • Graser A, Becker CR, Staehler M, et al. Singlephase dual energy CT allows for characterisation of renal masses as benign or malignant. Invest Radiol 2010; 45:399-405
    • (2010) Invest Radiol , vol.45 , pp. 399-405
    • Graser, A.1    Becker, C.R.2    Staehler, M.3
  • 19
    • 82455217291 scopus 로고    scopus 로고
    • Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual energy CT
    • Kaza RK, Caoili EM, Cohan RH, Platt JF. Distinguishing enhancing from nonenhancing renal lesions with fast kilovoltage-switching dual energy CT. AJR 2011; 197:1375-1381
    • (2011) AJR , vol.197 , pp. 1375-1381
    • Kaza, R.K.1    Caoili, E.M.2    Cohan, R.H.3    Platt, J.F.4
  • 20
    • 84865778492 scopus 로고    scopus 로고
    • Dual-energy computed tomography (DECT) in renal masses: Nonlinear versus linear blending
    • Ascenti G, Krauss B, Mazziotti S, et al. Dual-energy computed tomography (DECT) in renal masses: nonlinear versus linear blending. Acad Radiol 2012; 19:1186-1193
    • (2012) Acad Radiol , vol.19 , pp. 1186-1193
    • Ascenti, G.1    Krauss, B.2    Mazziotti, S.3
  • 22
    • 84880332561 scopus 로고    scopus 로고
    • Distinguishing enhancing from nonenhancing renal masses with dual-source dual energy CT: Iodine quantification versus standard enhancement measurements
    • Ascenti G, Mileto A, Krauss B, et al. Distinguishing enhancing from nonenhancing renal masses with dual-source dual energy CT: iodine quantification versus standard enhancement measurements. Eur Radiol 2013; 23:2288-2295
    • (2013) Eur Radiol , vol.23 , pp. 2288-2295
    • Ascenti, G.1    Mileto, A.2    Krauss, B.3
  • 23
    • 82455203955 scopus 로고    scopus 로고
    • Utility of iodine overlay technique and virtual unenhanced images for the characterization of renal masses by dual-energy CT
    • Song KD, Kim CK, Park BK, Kim B. Utility of iodine overlay technique and virtual unenhanced images for the characterization of renal masses by dual-energy CT. AJR 2011; 197:[web]W1076-W1082
    • (2011) AJR , vol.197 , pp. W1076-W1082
    • Song, K.D.1    Kim, C.K.2    Park, B.K.3    Kim, B.4
  • 25
    • 84899540224 scopus 로고    scopus 로고
    • State of the art: Dual-energy CT of the abdomen
    • Marin D, Boll DT, Mileto A, Nelson RC. State of the art: dual-energy CT of the abdomen. Radiology 2014; 271:327-342
    • (2014) Radiology , vol.271 , pp. 327-342
    • Marin, D.1    Boll, D.T.2    Mileto, A.3    Nelson, R.C.4
  • 27
    • 84872043780 scopus 로고    scopus 로고
    • Best practice: Implementation and use of abdominal dual-energy CT in routine patient care
    • Megibow AJ, Sahani DV. Best practice: implementation and use of abdominal dual-energy CT in routine patient care. AJR 2012; 199:S71-S77
    • (2012) AJR , vol.199 , pp. S71-S77
    • Megibow, A.J.1    Sahani, D.V.2
  • 28
    • 70249111173 scopus 로고    scopus 로고
    • Dualenergy CT in patients suspected of having renal masses: Can virtual nonenhanced images replace true nonenhanced images?
    • Graser A, Johnson TR, Hecht EM, et al. Dualenergy CT in patients suspected of having renal masses: can virtual nonenhanced images replace true nonenhanced images? Radiology 2009; 252:433-440
    • (2009) Radiology , vol.252 , pp. 433-440
    • Graser, A.1    Johnson, T.R.2    Hecht, E.M.3
  • 29
    • 84865726979 scopus 로고    scopus 로고
    • Dualsource dual-energy CT evaluation of complex cystic renal masses
    • Ascenti G, Mazziotti S, Mileto A, et al. Dualsource dual-energy CT evaluation of complex cystic renal masses. AJR 2012; 199:1026-1034
    • (2012) AJR , vol.199 , pp. 1026-1034
    • Ascenti, G.1    Mazziotti, S.2    Mileto, A.3
  • 30
    • 84899512453 scopus 로고    scopus 로고
    • Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions
    • Mileto A, Marin D, Ramirez-Giraldo JC. Accuracy of contrast-enhanced dual-energy MDCT for the assessment of iodine uptake in renal lesions. AJR 2014; 202:[web]W466-W474
    • (2014) AJR , vol.202 , pp. W466-W474
    • Mileto, A.1    Marin, D.2    Ramirez-Giraldo, J.C.3
  • 31
    • 79960551830 scopus 로고    scopus 로고
    • Iodine quantification with dual-energy CT: Phantom study and preliminary experience with renal masses
    • Chandarana H, Megibow AJ, Cohen BA, et al. Iodine quantification with dual-energy CT: phantom study and preliminary experience with renal masses. AJR 2011; 196:[web]W693-W700
    • (2011) AJR , vol.196 , pp. W693-W700
    • Chandarana, H.1    Megibow, A.J.2    Cohen, B.A.3
  • 32
    • 84870948219 scopus 로고    scopus 로고
    • Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: A phantom study
    • Jung DC, Oh YT, Kim MD, Park M. Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR 2012; 199:1316-1319
    • (2012) AJR , vol.199 , pp. 1316-1319
    • Jung, D.C.1    Oh, Y.T.2    Kim, M.D.3    Park, M.4
  • 33
    • 79953011586 scopus 로고    scopus 로고
    • Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT
    • Matsumoto K, Jinzaki M, Tanami Y, Ueno A, Yamada M, Kuribayashi S. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 2011; 259:257-262
    • (2011) Radiology , vol.259 , pp. 257-262
    • Matsumoto, K.1    Jinzaki, M.2    Tanami, Y.3    Ueno, A.4    Yamada, M.5    Kuribayashi, S.6
  • 34
    • 82755163901 scopus 로고    scopus 로고
    • Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
    • Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 2011; 38:6371-6379
    • (2011) Med Phys , vol.38 , pp. 6371-6379
    • Yu, L.1    Christner, J.A.2    Leng, S.3    Wang, J.4    Fletcher, J.G.5    McCollough, C.H.6
  • 35
    • 79953672323 scopus 로고    scopus 로고
    • Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner
    • Goodsitt MM, Christodoulou EG, Larson SC. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Med Phys 2011; 38:2222-2232
    • (2011) Med Phys , vol.38 , pp. 2222-2232
    • Goodsitt, M.M.1    Christodoulou, E.G.2    Larson, S.C.3
  • 36
    • 84906871924 scopus 로고    scopus 로고
    • Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: In vitro and in vivo study
    • Mileto A, Nelson RC, Samei E, et al. Impact of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study. Radiology 2014; 272:767-776
    • (2014) Radiology , vol.272 , pp. 767-776
    • Mileto, A.1    Nelson, R.C.2    Samei, E.3
  • 37
    • 84906875948 scopus 로고    scopus 로고
    • Dual-energy multidetector row CT with virtual monochromatic imaging for improving patient-to-patient uniformity of aortic enhancement during CT angiography: An in vitro and in vivo study
    • Marin D, Fananapazir G, Mileto A, Choudhury KR, Wilson JM, Nelson RC. Dual-energy multidetector row CT with virtual monochromatic imaging for improving patient-to-patient uniformity of aortic enhancement during CT angiography: an in vitro and in vivo study. Radiology 2014; 272:895-902
    • (2014) Radiology , vol.272 , pp. 895-902
    • Marin, D.1    Fananapazir, G.2    Mileto, A.3    Choudhury, K.R.4    Wilson, J.M.5    Nelson, R.C.6
  • 38
    • 84925231339 scopus 로고    scopus 로고
    • Dual-energy MDCT in hypervascular liver tumors: Effect of body size on selection of the optimal monochromatic energy level
    • Mileto A, Nelson RC, Samei E, et al. Dual-energy MDCT in hypervascular liver tumors: effect of body size on selection of the optimal monochromatic energy level. AJR 2014; 203:1257-1264
    • (2014) AJR , vol.203 , pp. 1257-1264
    • Mileto, A.1    Nelson, R.C.2    Samei, E.3
  • 39
    • 84859500657 scopus 로고    scopus 로고
    • Applications of dual-energy CT in urologic imaging: An update
    • Hartman R, Kawashima A, Takahashi N, et al. Applications of dual-energy CT in urologic imaging: an update. Radiol Clin North Am 2012; 50:191-205
    • (2012) Radiol Clin North Am , vol.50 , pp. 191-205
    • Hartman, R.1    Kawashima, A.2    Takahashi, N.3
  • 40
    • 84916608502 scopus 로고    scopus 로고
    • Iodine quantification to distinguish clear cell from papillary renal cell carcinoma at dual-energy multidetector CT: A multireader diagnostic performance study
    • Mileto A, Marin D, Alfaro-Cordoba M, et al. Iodine quantification to distinguish clear cell from papillary renal cell carcinoma at dual-energy multidetector CT: a multireader diagnostic performance study. Radiology 2014; 273:813-820
    • (2014) Radiology , vol.273 , pp. 813-820
    • Mileto, A.1    Marin, D.2    Alfaro-Cordoba, M.3
  • 41
    • 65449156824 scopus 로고    scopus 로고
    • Quantitative imaging of element composition and mass fraction using dual-energy CT: Three-material decomposition
    • Liu X, Yu L, Primak AN, McCollough CH. Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition. Med Phys 2009; 36:1602-1609
    • (2009) Med Phys , vol.36 , pp. 1602-1609
    • Liu, X.1    Yu, L.2    Primak, A.N.3    McCollough, C.H.4
  • 42
    • 84874764053 scopus 로고    scopus 로고
    • Quantitative material characterization from multi-energy photon counting CT
    • Alessio AM, MacDonald LR. Quantitative material characterization from multi-energy photon counting CT. Med Phys 2013; 40:031108
    • (2013) Med Phys , vol.40 , pp. 031108
    • Alessio, A.M.1    MacDonald, L.R.2
  • 43
    • 84862639230 scopus 로고    scopus 로고
    • Virtual nonenhanced dual-energy CT urography with tinfilter technology: Determinants of detection of urinary calculi in the renal collecting system
    • Mangold S, Thomas C, Fenchel M, et al. Virtual nonenhanced dual-energy CT urography with tinfilter technology: determinants of detection of urinary calculi in the renal collecting system. Radiology 2012; 264:119-125
    • (2012) Radiology , vol.264 , pp. 119-125
    • Mangold, S.1    Thomas, C.2    Fenchel, M.3
  • 44
    • 84906875942 scopus 로고    scopus 로고
    • Increasing the precision of CT measurements with dual-energy scanning
    • Megibow AJ, Chandarana H, Hindman NM. Increasing the precision of CT measurements with dual-energy scanning. Radiology 2014; 272:618-621
    • (2014) Radiology , vol.272 , pp. 618-621
    • Megibow, A.J.1    Chandarana, H.2    Hindman, N.M.3
  • 45
    • 78649653575 scopus 로고    scopus 로고
    • Appropriate patient selection at abdominal dualenergy CT using 80 kV: Relationship between patient size, image noise, and image quality
    • Guimarães LS, Fletcher JG, Harmsen WS, et al. Appropriate patient selection at abdominal dualenergy CT using 80 kV: relationship between patient size, image noise, and image quality. Radiology 2010; 257:732-742
    • (2010) Radiology , vol.257 , pp. 732-742
    • Guimarães, L.S.1    Fletcher, J.G.2    Harmsen, W.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.