-
1
-
-
0038626429
-
Peak contrast enhancement in CT and MR angiography: When does it occur and why? Pharmacokinetic study in a porcine model
-
DOI 10.1148/radiol.2273020102
-
Bae KT. Peak contrast enhancement in CT and MR angiography: when does it occur and why? pharmacokinetic study in a porcine model. Radiology 2003;227(3):809-816. (Pubitemid 36583041)
-
(2003)
Radiology
, vol.227
, Issue.3
, pp. 809-816
-
-
Bae, K.T.1
-
2
-
-
77953948373
-
Intravenous contrast medium administration and scan timing at CT: Considerations and approaches
-
Bae KT. Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology 2010;256(1):32-61.
-
(2010)
Radiology
, vol.256
, Issue.1
, pp. 32-61
-
-
Bae, K.T.1
-
3
-
-
0020503344
-
Dynamic contrast enhancement of the upper abdomen: Effect of contrast medium and body weight
-
Kormano M, Partanen K, Soimakallio S, Kivimäki T. Dynamic contrast enhancement of the upper abdomen: effect of contrast medium and body weight. Invest Radiol 1983;18(4):364-367. (Pubitemid 13033234)
-
(1983)
Investigative Radiology
, vol.18
, Issue.4
, pp. 364-367
-
-
Kormano, M.1
Partanen, K.2
Soimakallio, S.3
Kivimaki, T.4
-
4
-
-
0028944743
-
Dynamic incremental CT: Effect of volume and concentration of contrast material and patient weight on hepatic enhancement
-
Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV. Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology 1995;195(2):353-357.
-
(1995)
Radiology
, vol.195
, Issue.2
, pp. 353-357
-
-
Heiken, J.P.1
Brink, J.A.2
McClennan, B.L.3
Sagel, S.S.4
Crowe, T.M.5
Gaines, M.V.6
-
5
-
-
0032930075
-
Aortic enhancement during abdominal CT angiography: Correlation with test injections, flow rates, and patient demographics
-
Platt JF, Reige KA, Ellis JH. Aortic enhancement during abdominal CT angiography: correlation with test injections, flow rates, and patient demographics. AJR Am J Roentgenol 1999;172(1):53-56. (Pubitemid 29028429)
-
(1999)
American Journal of Roentgenology
, vol.172
, Issue.1
, pp. 53-56
-
-
Platt, J.F.1
Reige, K.A.2
Ellis, J.H.3
-
6
-
-
77955129810
-
Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: An in vitro and in vivo study
-
Schindera ST, Tock I, Marin D, et al. Effect of beam hardening on arterial enhancement in thoracoabdominal CT angiography with increasing patient size: an in vitro and in vivo study. Radiology 2010;256(2):528-535.
-
(2010)
Radiology
, vol.256
, Issue.2
, pp. 528-535
-
-
Schindera, S.T.1
Tock, I.2
Marin, D.3
-
7
-
-
77953935506
-
Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion
-
Kitagawa K, George RT, Arbab-Zadeh A, Lima JAC, Lardo AC. Characterization and correction of beam-hardening artifacts during dynamic volume CT assessment of myocardial perfusion. Radiology 2010;256(1):111-118.
-
(2010)
Radiology
, vol.256
, Issue.1
, pp. 111-118
-
-
Kitagawa, K.1
George, R.T.2
Arbab-Zadeh, A.3
Lima, J.A.C.4
Lardo, A.C.5
-
8
-
-
79953011586
-
Virtual monochromatic spectral imaging with fast kilovoltage switching: Improved image quality as compared with that obtained with conventional 120-kVp CT
-
Matsumoto K, Jinzaki M, Tanami Y, Ueno A, Yamada M, Kuribayashi S. Virtual monochromatic spectral imaging with fast kilovoltage switching: improved image quality as compared with that obtained with conventional 120-kVp CT. Radiology 2011;259(1):257-262.
-
(2011)
Radiology
, vol.259
, Issue.1
, pp. 257-262
-
-
Matsumoto, K.1
Jinzaki, M.2
Tanami, Y.3
Ueno, A.4
Yamada, M.5
Kuribayashi, S.6
-
9
-
-
84867258854
-
Spectral CT in patients with small HCC: Investigation of image quality and diagnostic accuracy
-
Lv P, Lin XZ, Chen K, Gao J. Spectral CT in patients with small HCC: investigation of image quality and diagnostic accuracy. Eur Radiol 2012;22(10):2117-2124.
-
(2012)
Eur Radiol
, vol.22
, Issue.10
, pp. 2117-2124
-
-
Lv, P.1
Lin, X.Z.2
Chen, K.3
Gao, J.4
-
10
-
-
84872006135
-
Dual-energy CT-based monochromatic imaging
-
Yu L, Leng S, McCollough CH. Dual-energy CT-based monochromatic imaging. AJR Am J Roentgenol 2012;199(5 Suppl):S9-S15.
-
(2012)
AJR Am J Roentgenol
, vol.199
, Issue.5 SUPPL.
-
-
Yu, L.1
Leng, S.2
McCollough, C.H.3
-
11
-
-
66749125974
-
Monochromatic CT image representation via fast switching dual kVp
-
Samei E, Hsieh J, eds. Bellingham, Wash: SPIE-The International Society for Optical Engineering
-
Wu X, Langan DA, Xu D, et al. Monochromatic CT image representation via fast switching dual kVp. In: Samei E, Hsieh J, eds. Proceedings of SPIE: medical imaging 2009 - physics of medical imaging. Vol 7258. Bellingham, Wash: SPIE-The International Society for Optical Engineering, 2009; 725845.
-
(2009)
Proceedings of SPIE: Medical Imaging 2009 - Physics of Medical Imaging
, vol.7258
, pp. 725845
-
-
Wu, X.1
Langan, D.A.2
Xu, D.3
-
12
-
-
79953672323
-
Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner
-
Goodsitt MM, Christodoulou EG, Larson SC. Accuracies of the synthesized monochromatic CT numbers and effective atomic numbers obtained with a rapid kVp switching dual energy CT scanner. Med Phys 2011;38(4):2222-2232.
-
(2011)
Med Phys
, vol.38
, Issue.4
, pp. 2222-2232
-
-
Goodsitt, M.M.1
Christodoulou, E.G.2
Larson, S.C.3
-
13
-
-
82755163901
-
Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality
-
Yu L, Christner JA, Leng S, Wang J, Fletcher JG, McCollough CH. Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality. Med Phys 2011;38(12):6371-6379.
-
(2011)
Med Phys
, vol.38
, Issue.12
, pp. 6371-6379
-
-
Yu, L.1
Christner, J.A.2
Leng, S.3
Wang, J.4
Fletcher, J.G.5
McCollough, C.H.6
-
14
-
-
84875147000
-
Virtual monochromatic spectral imaging with fast kilovoltage switching: Reduction of metal artifacts at CT
-
Pessis E, Campagna R, Sverzut JM, et al. Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT. RadioGraphics 2013;33(2):573-583.
-
(2013)
RadioGraphics
, vol.33
, Issue.2
, pp. 573-583
-
-
Pessis, E.1
Campagna, R.2
Sverzut, J.M.3
-
15
-
-
84870948219
-
Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: A phantom study
-
Jung DC, Oh YT, Kim MD, Park M. Usefulness of the virtual monochromatic image in dual-energy spectral CT for decreasing renal cyst pseudoenhancement: a phantom study. AJR Am J Roentgenol 2012;199(6):1316-1319.
-
(2012)
AJR Am J Roentgenol
, vol.199
, Issue.6
, pp. 1316-1319
-
-
Jung, D.C.1
Oh, Y.T.2
Kim, M.D.3
Park, M.4
-
16
-
-
79959373981
-
Development of a fillable, tapered PET/CT phantom
-
Wilson JM, Lokitz SJ, Turkington TG. Development of a fillable, tapered PET/CT phantom. IEEE Trans Nucl Sci 2011;58(3):651-659.
-
(2011)
IEEE Trans Nucl Sci
, vol.58
, Issue.3
, pp. 651-659
-
-
Wilson, J.M.1
Lokitz, S.J.2
Turkington, T.G.3
-
18
-
-
84870040137
-
Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation
-
Brady SL, Kaufman RA. Investigation of American Association of Physicists in Medicine Report 204 size-specific dose estimates for pediatric CT implementation. Radiology 2012;265(3):832-840.
-
(2012)
Radiology
, vol.265
, Issue.3
, pp. 832-840
-
-
Brady, S.L.1
Kaufman, R.A.2
-
19
-
-
84906871924
-
Effect of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: In vitro and in vivo study
-
Mileto A, Nelson RC, Samei E, et al. Effect of dual-energy multi-detector row CT with virtual monochromatic imaging on renal cyst pseudoenhancement: in vitro and in vivo study. Radiology 2014;273(2):767-776.
-
(2014)
Radiology
, vol.273
, Issue.2
, pp. 767-776
-
-
Mileto, A.1
Nelson, R.C.2
Samei, E.3
|