메뉴 건너뛰기




Volumn 204, Issue 6, 2015, Pages 1197-1202

Ultra-low-dose CT of the thorax using iterative reconstruction: Evaluation of image quality and radiation dose reduction

Author keywords

Chest; CT; Iterative reconstruction; Low dose

Indexed keywords

ADULT; AGED; ARTICLE; BODY MASS; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DOSE LENGTH PRODUCT; DOSE RESPONSE; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE NOISE; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; LOW DOSE COMPUTED TOMOGRAPHY; LUNG EMPHYSEMA; MALE; MIDDLE AGED; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIATION DOSE; RADIATION DOSE INDEX; RADIATION DOSE REDUCTION; RADIOLOGICAL PARAMETERS; SINOGRAM AFFIRMED ITERATIVE RECONSTRUCTION; THORAX RADIOGRAPHY; COMPUTER ASSISTED DIAGNOSIS; LUNG DISEASE; OBSERVER VARIATION; PATIENT SAFETY; PROCEDURES; RADIATION PROTECTION; RADIOGRAPHY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; YOUNG ADULT;

EID: 84937694172     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.14.13629     Document Type: Article
Times cited : (115)

References (21)
  • 1
    • 38849084698 scopus 로고    scopus 로고
    • Radiation dose reduction in chest CT: A review
    • Kubo T, Lin PJ, Stiller W, et al. Radiation dose reduction in chest CT: a review. AJR 2008; 190:335-343
    • (2008) AJR , vol.190 , pp. 335-343
    • Kubo, T.1    Lin, P.J.2    Stiller, W.3
  • 2
    • 84878743872 scopus 로고    scopus 로고
    • Iterative reconstruction techniques for computed tomography Part 2 Initial results in dose reduction and image quality
    • Willemink MJ, Leiner T, de Jong PA, et al. Iterative reconstruction techniques for computed tomography. Part 2 Initial results in dose reduction and image quality. Eur Radiol 2013; 23:1632-1642
    • (2013) Eur Radiol , vol.23 , pp. 1632-1642
    • Willemink, M.J.1    Leiner, T.2    De Jong, P.A.3
  • 3
    • 84870380018 scopus 로고    scopus 로고
    • Lowdose CT of the lung: Potential value of iterative reconstructions
    • Baumueller S, Winklehner A, Karlo C, et al. Lowdose CT of the lung: potential value of iterative reconstructions. Eur Radiol 2012; 22:2597-2606
    • (2012) Eur Radiol , vol.22 , pp. 2597-2606
    • Baumueller, S.1    Winklehner, A.2    Karlo, C.3
  • 4
    • 84873989593 scopus 로고    scopus 로고
    • Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT patterns of pulmonary disease
    • Christe A, Charimo-Torrente J, Roychoudhury K, Vock P, Roos JE. Accuracy of low-dose computed tomography (CT) for detecting and characterizing the most common CT patterns of pulmonary disease. Eur J Radiol 2013; 82:e142-e150
    • (2013) Eur J Radiol , vol.82 , pp. e142-e150
    • Christe, A.1    Charimo-Torrente, J.2    Roychoudhury, K.3    Vock, P.4    Roos, J.E.5
  • 5
    • 84881169238 scopus 로고    scopus 로고
    • Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT
    • Xu Y, He W, Chen H, Hu Z, Li J, Zhang T. Impact of the adaptive statistical iterative reconstruction technique on image quality in ultra-low-dose CT. Clin Radiol 2013; 68:902-908
    • (2013) Clin Radiol , vol.68 , pp. 902-908
    • Xu, Y.1    He, W.2    Chen, H.3    Hu, Z.4    Li, J.5    Zhang, T.6
  • 6
    • 84868319541 scopus 로고    scopus 로고
    • Radiation dose reduction of chest CT with iterative reconstruction in image space Part 1 Studies on image quality using dual source CT
    • Hwang HJ, Seo JB, Lee JS, et al. Radiation dose reduction of chest CT with iterative reconstruction in image space. Part 1 Studies on image quality using dual source CT. Korean J Radiol 2012; 13:711-719
    • (2012) Korean J Radiol , vol.13 , pp. 711-719
    • Hwang, H.J.1    Seo, J.B.2    Lee, J.S.3
  • 7
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection Part 1 Evaluation of image noise reduction in 32 patients
    • Pontana F, Pagniez J, Flohr T, et al. Chest computed tomography using iterative reconstruction vs filtered back projection Part 1 Evaluation of image noise reduction in 32 patients. Eur Radiol 2011; 21:627-635
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 8
    • 84878598953 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: Preliminary observations
    • Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X. Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol 2013; 23:360-366
    • (2013) Eur Radiol , vol.23 , pp. 360-366
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3    Becker, C.D.4    Montet, X.5
  • 9
    • 84896319309 scopus 로고    scopus 로고
    • Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction
    • Lee SW, Kim Y, Shim SS, et al. Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstruction. Eur Radiol 2014; 24:817-826
    • (2014) Eur Radiol , vol.24 , pp. 817-826
    • Lee, S.W.1    Kim, Y.2    Shim, S.S.3
  • 10
    • 80053922582 scopus 로고    scopus 로고
    • Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection
    • Moscariello A, Takx RA, Schoepf UJ, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection. Eur Radiol 2011; 21:2130-2138
    • (2011) Eur Radiol , vol.21 , pp. 2130-2138
    • Moscariello, A.1    Takx, R.A.2    Schoepf, U.J.3
  • 12
    • 8644226203 scopus 로고    scopus 로고
    • The feasibility of low-dose CT for pulmonary metastasis in patients with primary gynecologic malignancy
    • Weng MJ, Wu MT, Pan HB, Kan YY, Yang CF. The feasibility of low-dose CT for pulmonary metastasis in patients with primary gynecologic malignancy. Clin Imaging 2004; 28:408-414
    • (2004) Clin Imaging , vol.28 , pp. 408-414
    • Weng, M.J.1    Wu, M.T.2    Pan, H.B.3    Kan, Y.Y.4    Yang, C.F.5
  • 13
    • 0042132003 scopus 로고    scopus 로고
    • Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    • Karabulut N, Toru M, Gelebek V, Gulsun M, Ariyurek OM. Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules. Eur Radiol 2002; 12:2764-2769
    • (2002) Eur Radiol , vol.12 , pp. 2764-2769
    • Karabulut, N.1    Toru, M.2    Gelebek, V.3    Gulsun, M.4    Ariyurek, O.M.5
  • 14
    • 70350508400 scopus 로고    scopus 로고
    • Cystic fibrosis: Are volumetric ultra-low-dose expiratory CT scans sufficient for monitoring related lung disease?
    • Loeve M, Lequin MH, de Bruijne M, et al. Cystic fibrosis: are volumetric ultra-low-dose expiratory CT scans sufficient for monitoring related lung disease? Radiology 2009; 253:223-229
    • (2009) Radiology , vol.253 , pp. 223-229
    • Loeve, M.1    Lequin, M.H.2    De Bruijne, M.3
  • 15
    • 41649097351 scopus 로고    scopus 로고
    • Ultra-low-dose MDCT of the chest: Influence on automated lung nodule detection
    • Lee JY, Chung MJ, Yi CA, Lee KS. Ultra-low-dose MDCT of the chest: influence on automated lung nodule detection. Korean J Radiol 2008; 9:95-101
    • (2008) Korean J Radiol , vol.9 , pp. 95-101
    • Lee, J.Y.1    Chung, M.J.2    Yi, C.A.3    Lee, K.S.4
  • 16
    • 77953939681 scopus 로고    scopus 로고
    • Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Ackman JB, et al. Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology 2010; 256:261-269
    • (2010) Radiology , vol.256 , pp. 261-269
    • Prakash, P.1    Kalra, M.K.2    Ackman, J.B.3
  • 17
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of lowdose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
    • Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q. Abdominal CT: comparison of lowdose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR 2010; 195:713-719
    • (2010) AJR , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3    Silva, A.C.4    Paden, R.G.5    Wu, Q.6
  • 18
    • 84866864966 scopus 로고    scopus 로고
    • Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: Comparison with standard-dose CT for image noise reduction and radiological findings
    • Ohno Y, Takenaka D, Kanda T, et al. Adaptive iterative dose reduction using 3D processing for reduced-and low-dose pulmonary CT: comparison with standard-dose CT for image noise reduction and radiological findings. AJR 2012; 199:[web] W477-W485
    • (2012) AJR , vol.199 , pp. W477-W485
    • Ohno, Y.1    Takenaka, D.2    Kanda, T.3
  • 19
    • 84873157669 scopus 로고    scopus 로고
    • CT coronary angiography: Image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection
    • Wang R, Schoepf UJ, Wu R, et al. CT coronary angiography: image quality with sinogram-affirmed iterative reconstruction compared with filtered back-projection. Clin Radiol 2013; 68:272-278
    • (2013) Clin Radiol , vol.68 , pp. 272-278
    • Wang, R.1    Schoepf, U.J.2    Wu, R.3
  • 20
    • 83555174941 scopus 로고    scopus 로고
    • Raw data-based iterative reconstruction in body CTA: Evaluation of radiation dose saving potential
    • Winklehner A, Karlo C, Puippe G, et al. Raw data-based iterative reconstruction in body CTA: evaluation of radiation dose saving potential. Eur Radiol 2011; 21:2521-2526
    • (2011) Eur Radiol , vol.21 , pp. 2521-2526
    • Winklehner, A.1    Karlo, C.2    Puippe, G.3
  • 21
    • 84864713607 scopus 로고    scopus 로고
    • Modelbased iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, et al. Modelbased iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 2012; 22:1613-1623
    • (2012) Eur Radiol , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.