메뉴 건너뛰기




Volumn 61, Issue 2, 2015, Pages 144-149

Device Exchange in HeartMate II Recipients: Long-Term Outcomes and Risk of Thrombosis Recurrence

Author keywords

CF LVAD; Exchange; LVAD; Malfunction; Sternotomy; Subcostal; Thrombosis

Indexed keywords

BLOOD VESSELS; DISEASES; FAILURE (MECHANICAL); ION EXCHANGE;

EID: 84937629018     PISSN: 10582916     EISSN: 1538943X     Source Type: Journal    
DOI: 10.1097/MAT.0000000000000170     Document Type: Article
Times cited : (31)

References (14)
  • 1
    • 84892148459 scopus 로고    scopus 로고
    • Unexpected abrupt increase in left ventricular assist device thrombosis
    • Starling RC, Moazami N, Silvestry SC, Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med 2014 370 33 40
    • (2014) N Engl J Med , vol.370 , pp. 33-40
    • Starling, R.C.1    Moazami, N.2    Silvestry, S.C.3
  • 2
    • 84892177900 scopus 로고    scopus 로고
    • Intermacs analysis of pump thrombosis in the HeartMate II left ventricular assist device
    • Kirklin JK, Naftel DC, Kormos RL, Intermacs analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 2014 33 12 22
    • (2014) J Heart Lung Transplant , vol.33 , pp. 12-22
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 3
    • 84892181492 scopus 로고    scopus 로고
    • Continuous-flow left ventricular assist device exchange: Clinical outcomes
    • Ota T, Yerebakan H, Akashi H, Continuous-flow left ventricular assist device exchange: clinical outcomes. J Heart Lung Transplant 2014 33 65 70
    • (2014) J Heart Lung Transplant , vol.33 , pp. 65-70
    • Ota, T.1    Yerebakan, H.2    Akashi, H.3
  • 4
    • 42949136384 scopus 로고    scopus 로고
    • Clinical experience with sternotomy versus subcostal approach for exchange of the HeartMate XVE to the HeartMate II ventricular assist device
    • Gregoric ID, Bruckner BA, Jacob L, Clinical experience with sternotomy versus subcostal approach for exchange of the HeartMate XVE to the HeartMate II ventricular assist device. Ann Thorac Surg 2008 85 1646 1649
    • (2008) Ann Thorac Surg , vol.85 , pp. 1646-1649
    • Gregoric, I.D.1    Bruckner, B.A.2    Jacob, L.3
  • 5
    • 77957561535 scopus 로고    scopus 로고
    • Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation
    • Uriel N, Pak SW, Jorde UP, Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol 2010 56 1207 1213
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1207-1213
    • Uriel, N.1    Pak, S.W.2    Jorde, U.P.3
  • 6
    • 77952583879 scopus 로고    scopus 로고
    • Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy
    • Slaughter MS, Naka Y, John R, Post-operative heparin may not be required for transitioning patients with a HeartMate II left ventricular assist system to long-term warfarin therapy. J Heart Lung Transplant 2010 29 616 624
    • (2010) J Heart Lung Transplant , vol.29 , pp. 616-624
    • Slaughter, M.S.1    Naka, Y.2    John, R.3
  • 7
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • Rose EA, Gelijns AC, Moskowitz AJ, Randomized Evaluation of Mechanical Assistance for the Treatment of Congestive Heart Failure (REMATCH) Study Group Long-term use of a left ventricular assist device for end-stage heart failure. N Engl J Med 2001 345 1435 1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 8
    • 84860820973 scopus 로고    scopus 로고
    • Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy
    • Park SJ, Milano CA, Tatooles AJ, HeartMate II Clinical Investigators Outcomes in advanced heart failure patients with left ventricular assist devices for destination therapy. Circ Heart Fail 2012 5 241 248
    • (2012) Circ Heart Fail , vol.5 , pp. 241-248
    • Park, S.J.1    Milano, C.A.2    Tatooles, A.J.3
  • 9
    • 84867890273 scopus 로고    scopus 로고
    • Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: The Columbia ramp study
    • Uriel N, Morrison KA, Garan AR, Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: the Columbia ramp study. J Am Coll Cardiol 2012 60 1764 1775
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1764-1775
    • Uriel, N.1    Morrison, K.A.2    Garan, A.R.3
  • 11
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, HeartMate II Investigators Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009 361 2241 2251
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 12
    • 84872765576 scopus 로고    scopus 로고
    • Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality
    • Moazami N, Milano CA, John R, HeartMate II Investigators Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality. Ann Thorac Surg 2013 95 500 505
    • (2013) Ann Thorac Surg , vol.95 , pp. 500-505
    • Moazami, N.1    Milano, C.A.2    John, R.3
  • 13
    • 84875342292 scopus 로고    scopus 로고
    • Device exchange after primary left ventricular assist device implantation: Indications and outcomes
    • discussion 1267
    • Stulak JM, Cowger J, Haft JW, Romano MA, Aaronson KD, Pagani FD, Device exchange after primary left ventricular assist device implantation: indications and outcomes. Ann Thorac Surg 2013 95 1262 1267. discussion 1267
    • (2013) Ann Thorac Surg , vol.95 , pp. 1262-1267
    • Stulak, J.M.1    Cowger, J.2    Haft, J.W.3    Romano, M.A.4    Aaronson, K.D.5    Pagani, F.D.6
  • 14
    • 84892157543 scopus 로고    scopus 로고
    • Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon
    • Uriel N, Han J, Morrison KA, Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon. J Heart Lung Transplant 2014 33 51 59
    • (2014) J Heart Lung Transplant , vol.33 , pp. 51-59
    • Uriel, N.1    Han, J.2    Morrison, K.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.