메뉴 건너뛰기




Volumn 50, Issue 8, 2015, Pages 481-482

Commentary on T1-Weighted Hypersignal in the Deep Cerebellar Nuclei after Repeated Administrations of Gadolinium-Based Contrast Agents in Healthy Rats: Difference between Linear and Macrocyclic Agents

Author keywords

[No Author keywords available]

Indexed keywords

GADOBUTROL; GADODIAMIDE; GADOLINIUM; GADOLINIUM CHELATE; GADOLINIUM PENTETATE MEGLUMINE; GADOTERATE MEGLUMINE; GADOTERIDOL; GADOVERSETAMIDE; METAL CHELATE; CONTRAST MEDIUM; GADOLINIUM PENTETATE; MEGLUMINE; ORGANOMETALLIC COMPOUND;

EID: 84937575803     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0000000000000182     Document Type: Note
Times cited : (29)

References (22)
  • 1
    • 84937562438 scopus 로고    scopus 로고
    • T1-weighted hypersignal in the deep cerebellar nuclei following repeated administrations of gadolinium-based contrast agents in healthy rats: Difference between linear and macrocyclic agents
    • Robert P, Lehéricy S, Sylvie G, T1-weighted hypersignal in the deep cerebellar nuclei following repeated administrations of gadolinium-based contrast agents in healthy rats: difference between linear and macrocyclic agents. Invest Radiol. 2015; 50: 473-480.
    • (2015) Invest Radiol , vol.50 , pp. 473-480
    • Robert, P.1    Lehéricy, S.2    Sylvie, G.3
  • 2
    • 84925745727 scopus 로고    scopus 로고
    • Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation
    • Errante Y, Cirimele V, Mallio CA, Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation. Invest Radiol. 2014; 49: 685-690.
    • (2014) Invest Radiol , vol.49 , pp. 685-690
    • Errante, Y.1    Cirimele, V.2    Mallio, C.A.3
  • 3
    • 84895462915 scopus 로고    scopus 로고
    • High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: Relationship with increasing cumulative dose of a gadolinium-based contrast material
    • Kanda T, Ishii K, Kawaguchi H, High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology. 2014; 270: 834-841.
    • (2014) Radiology , vol.270 , pp. 834-841
    • Kanda, T.1    Ishii, K.2    Kawaguchi, H.3
  • 4
    • 84930826124 scopus 로고    scopus 로고
    • High signal intensity in dentate nucleus on unenhanced T1-weighted MR images: Association with linear versus macrocyclic gadolinium chelate administration
    • Kanda T, Osawa M, Oba H, High signal intensity in dentate nucleus on unenhanced T1-weighted MR images: association with linear versus macrocyclic gadolinium chelate administration. Radiology. 2015; 275: 803-809.
    • (2015) Radiology , vol.275 , pp. 803-809
    • Kanda, T.1    Osawa, M.2    Oba, H.3
  • 5
    • 84931833555 scopus 로고    scopus 로고
    • Gadodiamide and dentate nucleus T1 hyperintensity in patients with meningioma evaluated by multiple follow-up contrast-enhanced magnetic resonance examinations with no systemic interval therapy
    • Quattrocchi CC, Mallio CA, Errante Y, Gadodiamide and dentate nucleus T1 hyperintensity in patients with meningioma evaluated by multiple follow-up contrast-enhanced magnetic resonance examinations with no systemic interval therapy. Invest Radiol. 2015; 50: 470-472.
    • (2015) Invest Radiol , vol.50 , pp. 470-472
    • Quattrocchi, C.C.1    Mallio, C.A.2    Errante, Y.3
  • 6
    • 84930863146 scopus 로고    scopus 로고
    • Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent
    • Radbruch A, Weberling LD, Kieslich PJ, Gadolinium retention in the dentate nucleus and globus pallidus is dependent on the class of contrast agent. Radiology. 2015; 275: 783-791.
    • (2015) Radiology , vol.275 , pp. 783-791
    • Radbruch, A.1    Weberling, L.D.2    Kieslich, P.J.3
  • 7
    • 84930850951 scopus 로고    scopus 로고
    • Intracranial gadolinium deposition after contrast-enhanced MR imaging
    • McDonald RJ, McDonald JS, Kallmes DF, Intracranial gadolinium deposition after contrast-enhanced MR imaging. Radiology. 2015; 275: 772-782.
    • (2015) Radiology , vol.275 , pp. 772-782
    • McDonald, R.J.1    McDonald, J.S.2    Kallmes, D.F.3
  • 8
    • 84936147184 scopus 로고    scopus 로고
    • Gadolinium-based contrast agent accumulates in the brain even in subjects without severe renal dysfunction: Evaluation of autopsy brain specimens with inductively coupled plasma mass spectroscopy
    • Kanda T, Fukusato T, Matsuda M, Gadolinium-based contrast agent accumulates in the brain even in subjects without severe renal dysfunction: evaluation of autopsy brain specimens with inductively coupled plasma mass spectroscopy. Radiology. 2015; 142690.
    • (2015) Radiology , pp. 142690
    • Kanda, T.1    Fukusato, T.2    Matsuda, M.3
  • 9
    • 33645289942 scopus 로고    scopus 로고
    • Gadolinium-a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?
    • Grobner T,. Gadolinium-a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis? Nephrol Dial Transplant. 2006; 21: 1104-1108.
    • (2006) Nephrol Dial Transplant , vol.21 , pp. 1104-1108
    • Grobner, T.1
  • 10
    • 33846223894 scopus 로고    scopus 로고
    • Nephrogenic systemic fibrosis: A review of 6 cases temporally related to gadodiamide injection (Omniscan)
    • Khurana A, Runge VM, Narayanan M, Nephrogenic systemic fibrosis: a review of 6 cases temporally related to gadodiamide injection (Omniscan). Invest Radiol. 2007; 42: 139-145.
    • (2007) Invest Radiol , vol.42 , pp. 139-145
    • Khurana, A.1    Runge, V.M.2    Narayanan, M.3
  • 11
    • 38149086937 scopus 로고    scopus 로고
    • High prevalence of nephrogenic systemic fibrosis in chronic renal failure patients exposed to gadodiamide, a gadolinium-containing magnetic resonance contrast agent
    • Rydahl C, Thomsen HS, Marckmann P,. High prevalence of nephrogenic systemic fibrosis in chronic renal failure patients exposed to gadodiamide, a gadolinium-containing magnetic resonance contrast agent. Invest Radiol. 2008; 43: 141-144.
    • (2008) Invest Radiol , vol.43 , pp. 141-144
    • Rydahl, C.1    Thomsen, H.S.2    Marckmann, P.3
  • 12
    • 37549017297 scopus 로고    scopus 로고
    • A preclinical study to investigate the development of nephrogenic systemic fibrosis: A possible role for gadolinium-based contrast media
    • Sieber MA, Pietsch H, Walter J, A preclinical study to investigate the development of nephrogenic systemic fibrosis: a possible role for gadolinium-based contrast media. Invest Radiol. 2008; 43: 65-75.
    • (2008) Invest Radiol , vol.43 , pp. 65-75
    • Sieber, M.A.1    Pietsch, H.2    Walter, J.3
  • 13
    • 67651115687 scopus 로고    scopus 로고
    • Impact of renal impairment on long-term retention of gadolinium in the rodent skin following the administration of gadolinium-based contrast agents
    • Pietsch H, Lengsfeld P, Steger-Hartmann T, Impact of renal impairment on long-term retention of gadolinium in the rodent skin following the administration of gadolinium-based contrast agents. Invest Radiol. 2009; 44: 226-233.
    • (2009) Invest Radiol , vol.44 , pp. 226-233
    • Pietsch, H.1    Lengsfeld, P.2    Steger-Hartmann, T.3
  • 14
    • 73649097259 scopus 로고    scopus 로고
    • Gadolinium-based contrast agents and NSF: Evidence from animal experience
    • Sieber MA, Steger-Hartmann T, Lengsfeld P, Gadolinium-based contrast agents and NSF: evidence from animal experience. J Magn Reson Imaging. 2009; 30: 1268-1276.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 1268-1276
    • Sieber, M.A.1    Steger-Hartmann, T.2    Lengsfeld, P.3
  • 15
    • 0034761039 scopus 로고    scopus 로고
    • Conception of the first magnetic resonance imaging contrast agents: A brief history
    • de Haen C,. Conception of the first magnetic resonance imaging contrast agents: a brief history. Top Magn Reson Imaging. 2001; 12: 221-230.
    • (2001) Top Magn Reson Imaging , vol.12 , pp. 221-230
    • De Haen, C.1
  • 17
    • 0021076626 scopus 로고
    • Paramagnetic agents for contrast-enhanced NMR imaging: A review
    • Runge VM, Clanton JA, Lukehart CM, Paramagnetic agents for contrast-enhanced NMR imaging: a review. AJR Am J Roentgenol. 1983; 141: 1209-1215.
    • (1983) AJR Am J Roentgenol , vol.141 , pp. 1209-1215
    • Runge, V.M.1    Clanton, J.A.2    Lukehart, C.M.3
  • 18
    • 0021915183 scopus 로고
    • Dyke award. Evaluation of contrast-enhanced MR imaging in a brain-abscess model
    • Runge VM, Clanton JA, Price AC, Dyke award. Evaluation of contrast-enhanced MR imaging in a brain-abscess model. AJNR Am J Neuroradiol. 1985; 6: 139-147.
    • (1985) AJNR Am J Neuroradiol , vol.6 , pp. 139-147
    • Runge, V.M.1    Clanton, J.A.2    Price, A.C.3
  • 19
    • 0026348501 scopus 로고
    • Clinical safety and efficacy of gadoteridol: A study in 411 patients with suspected intracranial and spinal disease
    • Runge VM, Bradley WG, Brant-Zawadzki MN, Clinical safety and efficacy of gadoteridol: a study in 411 patients with suspected intracranial and spinal disease. Radiology. 1991; 181: 701-709.
    • (1991) Radiology , vol.181 , pp. 701-709
    • Runge, V.M.1    Bradley, W.G.2    Brant-Zawadzki, M.N.3
  • 20
    • 0033852026 scopus 로고    scopus 로고
    • Safety of approved MR contrast media for intravenous injection
    • Runge VM,. Safety of approved MR contrast media for intravenous injection. J Magn Reson Imaging. 2000; 12: 205-213.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 205-213
    • Runge, V.M.1
  • 21
    • 81855220356 scopus 로고    scopus 로고
    • The developmental history of the gadolinium chelates as intravenous contrast media for magnetic resonance
    • Runge VM, Ai T, Hao D, The developmental history of the gadolinium chelates as intravenous contrast media for magnetic resonance. Invest Radiol. 2011; 46: 807-816.
    • (2011) Invest Radiol , vol.46 , pp. 807-816
    • Runge, V.M.1    Ai, T.2    Hao, D.3
  • 22
    • 33745918013 scopus 로고    scopus 로고
    • The cost of developing imaging agents for routine clinical use
    • Nunn AD,. The cost of developing imaging agents for routine clinical use. Invest Radiol. 2006; 41: 206-212.
    • (2006) Invest Radiol , vol.41 , pp. 206-212
    • Nunn, A.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.