메뉴 건너뛰기




Volumn 276, Issue 1, 2015, Pages 228-232

Gadolinium-based contrast agent accumulates in the brain even in subjects without severe renal dysfunction: Evaluation of autopsy brain specimens with inductively coupled plasma mass spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

CONTRAST MEDIUM; GADOLINIUM;

EID: 84936147184     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2015142690     Document Type: Article
Times cited : (752)

References (16)
  • 2
    • 0033852026 scopus 로고    scopus 로고
    • Safety of approved MR contrast media for intravenous injection
    • Runge VM. Safety of approved MR contrast media for intravenous injection. J Magn Reson Imaging 2000;12(2):205-213.
    • (2000) J Magn Reson Imaging , vol.12 , Issue.2 , pp. 205-213
    • Runge, V.M.1
  • 3
    • 73649093454 scopus 로고    scopus 로고
    • Role of thermodynamic and kinetic parameters in gadolinium chelate stability
    • Idée JM, Port M, Robic C, Medina C, Sabatou M, Corot C. Role of thermodynamic and kinetic parameters in gadolinium chelate stability. J Magn Reson Imaging 2009;30(6):1249-1258.
    • (2009) J Magn Reson Imaging , vol.30 , Issue.6 , pp. 1249-1258
    • Idée, J.M.1    Port, M.2    Robic, C.3    Medina, C.4    Sabatou, M.5    Corot, C.6
  • 4
    • 73649089329 scopus 로고    scopus 로고
    • Biodistribution of gadolinium-based contrast agents, including gadolinium deposition
    • Aime S, Caravan P. Biodistribution of gadolinium-based contrast agents, including gadolinium deposition. J Magn Reson Imaging 2009;30(6):1259-1267.
    • (2009) J Magn Reson Imaging , vol.30 , Issue.6 , pp. 1259-1267
    • Aime, S.1    Caravan, P.2
  • 5
    • 84895462915 scopus 로고    scopus 로고
    • High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: Relationship with increasing cumulative dose of a gadolinium-based contrast material
    • Kanda T, Ishii K, Kawaguchi H, Kitajima K, Takenaka D. High signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images: relationship with increasing cumulative dose of a gadolinium-based contrast material. Radiology 2014;270(3):834-841.
    • (2014) Radiology , vol.270 , Issue.3 , pp. 834-841
    • Kanda, T.1    Ishii, K.2    Kawaguchi, H.3    Kitajima, K.4    Takenaka, D.5
  • 6
    • 84930826124 scopus 로고    scopus 로고
    • High signal intensity in dentate nucleus on unenhanced T1-weighted MR images: Association with linear versus macrocyclic gadolinium chelate administration
    • Jan 27 Epub ahead of print
    • Kanda T, Osawa M, Oba H, et al. High signal intensity in dentate nucleus on unenhanced T1-weighted MR images: association with linear versus macrocyclic gadolinium chelate administration. Radiology 2015 Jan 27:140364. [Epub ahead of print]
    • (2015) Radiology
    • Kanda, T.1    Osawa, M.2    Oba, H.3
  • 7
    • 84925745727 scopus 로고    scopus 로고
    • Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation
    • Errante Y, Cirimele V, Mallio CA, Di Lazzaro V, Zobel BB, Quattrocchi CC. Progressive increase of T1 signal intensity of the dentate nucleus on unenhanced magnetic resonance images is associated with cumulative doses of intravenously administered gadodiamide in patients with normal renal function, suggesting dechelation. Invest Radiol 2014;49(10):685-690.
    • (2014) Invest Radiol , vol.49 , Issue.10 , pp. 685-690
    • Errante, Y.1    Cirimele, V.2    Mallio, C.A.3    Di Lazzaro, V.4    Zobel, B.B.5    Quattrocchi, C.C.6
  • 8
    • 80155146808 scopus 로고    scopus 로고
    • Multiorgan gadolinium (Gd) deposition and fibrosis in a patient with nephrogenic systemic fibrosis: An autopsy-based review
    • Sanyal S, Marckmann P, Scherer S, Abraham JL. Multiorgan gadolinium (Gd) deposition and fibrosis in a patient with nephrogenic systemic fibrosis: an autopsy-based review. Nephrol Dial Transplant 2011;26(11):3616-3626.
    • (2011) Nephrol Dial Transplant , vol.26 , Issue.11 , pp. 3616-3626
    • Sanyal, S.1    Marckmann, P.2    Scherer, S.3    Abraham, J.L.4
  • 9
    • 78650306746 scopus 로고    scopus 로고
    • Quantification of gadolinium in fresh skin and serum samples from patients with nephrogenic systemic fibrosis
    • Christensen KN, Lee CU, Hanley MM, Leung N, Moyer TP, Pittelkow MR. Quantification of gadolinium in fresh skin and serum samples from patients with nephrogenic systemic fibrosis. J Am Acad Dermatol 2011;64(1):91-96.
    • (2011) J Am Acad Dermatol , vol.64 , Issue.1 , pp. 91-96
    • Christensen, K.N.1    Lee, C.U.2    Hanley, M.M.3    Leung, N.4    Moyer, T.P.5    Pittelkow, M.R.6
  • 10
    • 1342344681 scopus 로고    scopus 로고
    • Comparison of Gd DTPA-BMA (Omniscan) versus Gd HP-DO3A (ProHance) retention in human bone tissue by inductively coupled plasma atomic emission spectroscopy
    • Gibby WA, Gibby KA, Gibby WA. Comparison of Gd DTPA-BMA (Omniscan) versus Gd HP-DO3A (ProHance) retention in human bone tissue by inductively coupled plasma atomic emission spectroscopy. Invest Radiol 2004;39(3):138-142.
    • (2004) Invest Radiol , vol.39 , Issue.3 , pp. 138-142
    • Gibby, W.A.1    Gibby, K.A.2    Gibby, W.A.3
  • 11
    • 33745910870 scopus 로고    scopus 로고
    • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy
    • White GW, Gibby WA, Tweedle MF. Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy. Invest Radiol 2006;41(3):272-278.
    • (2006) Invest Radiol , vol.41 , Issue.3 , pp. 272-278
    • White, G.W.1    Gibby, W.A.2    Tweedle, M.F.3
  • 13
    • 78349291543 scopus 로고    scopus 로고
    • Gadolinium released from MR contrast agents is deposited in brain tumors: In situ demonstration using scanning electron microscopy with energy dispersive X-ray spectroscopy
    • Xia D, Davis RL, Crawford JA, Abraham JL. Gadolinium released from MR contrast agents is deposited in brain tumors: in situ demonstration using scanning electron microscopy with energy dispersive X-ray spectroscopy. Acta Radiol 2010;51(10):1126-1136.
    • (2010) Acta Radiol , vol.51 , Issue.10 , pp. 1126-1136
    • Xia, D.1    Davis, R.L.2    Crawford, J.A.3    Abraham, J.L.4
  • 14
    • 84930850951 scopus 로고    scopus 로고
    • Intracranial gadolinium deposition after contrast-enhanced MR imaging
    • Mar 5 Epub ahead of print
    • McDonald RJ, McDonald JS, Kallmes DF, et al. Intracranial gadolinium deposition after contrast-enhanced MR imaging. Radiology 2015 Mar 5:150025. [Epub ahead of print]
    • (2015) Radiology
    • McDonald, R.J.1    McDonald, J.S.2    Kallmes, D.F.3
  • 15
    • 52049085751 scopus 로고    scopus 로고
    • Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions
    • Sieber MA, Lengsfeld P, Frenzel T, et al. Preclinical investigation to compare different gadolinium-based contrast agents regarding their propensity to release gadolinium in vivo and to trigger nephrogenic systemic fibrosis-like lesions. Eur Radiol 2008;18(10):2164-2173.
    • (2008) Eur Radiol , vol.18 , Issue.10 , pp. 2164-2173
    • Sieber, M.A.1    Lengsfeld, P.2    Frenzel, T.3
  • 16
    • 37549017297 scopus 로고    scopus 로고
    • A preclinical study to investigate the development of nephrogenic systemic fibrosis: A possible role for gadolinium-based contrast media
    • Sieber MA, Pietsch H, Walter J, Haider W, Frenzel T, Weinmann HJ. A preclinical study to investigate the development of nephrogenic systemic fibrosis: a possible role for gadolinium-based contrast media. Invest Radiol 2008;43(1):65-75.
    • (2008) Invest Radiol , vol.43 , Issue.1 , pp. 65-75
    • Sieber, M.A.1    Pietsch, H.2    Walter, J.3    Haider, W.4    Frenzel, T.5    Weinmann, H.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.