메뉴 건너뛰기




Volumn 2015, Issue 100, 2015, Pages

Reduction of iatrogenic atrial septal defects with an anterior and inferior transseptal puncture site when operating the cryoballoon ablation catheter

Author keywords

Atrial fibrillation; Catheter ablation; Cryoballoon; Iatrogenic atrial septal defect; Issue 100; Medicine; Transseptal puncture

Indexed keywords

ATRIAL FIBRILLATION; CATHETER ABLATION; CRYOSURGERY; DEVICES; HEART CATHETERIZATION; HEART SEPTAL DEFECTS, ATRIAL; HEART VENTRICLE SEPTUM; HUMAN; PROCEDURES; RETROSPECTIVE STUDY;

EID: 84937529356     PISSN: 1940087X     EISSN: None     Source Type: Journal    
DOI: 10.3791/52811     Document Type: Article
Times cited : (18)

References (15)
  • 1
    • 0032480265 scopus 로고    scopus 로고
    • Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins
    • Haïssaguerre, M., Jais, P., Shah, D. C., et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 339, (10), 659-666 (1998).
    • (1998) N Engl J Med , vol.339 , Issue.10 , pp. 659-666
    • Haïssaguerre, M.1    Jais, P.2    Shah, D.C.3
  • 2
    • 84865278119 scopus 로고    scopus 로고
    • Patient management and follow-up, definitions, endpoints, and research trial design: A report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation
    • Heart Rhythm Society Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques
    • Calkins, H., Kuck, K. H., Cappato, R., et al. Heart Rhythm Society Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design: a report of the Heart Rhythm Society (HRS) Task Force on Catheter and Surgical Ablation of Atrial Fibrillation. Heart Rhythm. 9, (4), 632-696 (2012).
    • (2012) Heart Rhythm , vol.9 , Issue.4 , pp. 632-696
    • Calkins, H.1    Kuck, K.H.2    Cappato, R.3
  • 3
    • 80755146099 scopus 로고    scopus 로고
    • New technologies for catheter ablation of atrial fibrillation
    • Gerstenfeld, E. P. New technologies for catheter ablation of atrial fibrillation. Curr Treat Options Cardiovasc Med. 13, (5), 393-401 (2011).
    • (2011) Curr Treat Options Cardiovasc Med , vol.13 , Issue.5 , pp. 393-401
    • Gerstenfeld, E.P.1
  • 4
    • 84876283750 scopus 로고    scopus 로고
    • Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: First results of the North American Arctic Front (STOP AF) pivotal trial
    • Packer, D. L., Kowal, R. C., Wheelan, K. R., et al. Cryoballoon ablation of pulmonary veins for paroxysmal atrial fibrillation: first results of the North American Arctic Front (STOP AF) pivotal trial. J Am Coll Cardiol. 61, (16), 1713-1723 (2013).
    • (2013) J am Coll Cardiol , vol.61 , Issue.16 , pp. 1713-1723
    • Packer, D.L.1    Kowal, R.C.2    Wheelan, K.R.3
  • 5
    • 80053396531 scopus 로고    scopus 로고
    • Persistent iatrogenic atrial septal defect after pulmonary vein isolation by cryoballoon: An underrecognized complication
    • Chan, N. Y., Choy, C. C., Lau, C. L., et al. Persistent iatrogenic atrial septal defect after pulmonary vein isolation by cryoballoon: an underrecognized complication. Europace. 13, (10), 1406-1410 (2011).
    • (2011) Europace , vol.13 , Issue.10 , pp. 1406-1410
    • Chan, N.Y.1    Choy, C.C.2    Lau, C.L.3
  • 6
    • 84900328447 scopus 로고    scopus 로고
    • Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up
    • Chierchia, G. B., Di Giovanni, G., Ciconte, G., et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace. 16, (5), 639-644 (2014).
    • (2014) Europace , vol.16 , Issue.5 , pp. 639-644
    • Chierchia, G.B.1    Di Giovanni, G.2    Ciconte, G.3
  • 7
    • 84900388394 scopus 로고    scopus 로고
    • Comparison of the first and second cryoballoon: High-volume single-center safety and efficacy analysis
    • Straube, F., Dorwarth, U., Schmidt, M., et al. Comparison of the first and second cryoballoon: high-volume single-center safety and efficacy analysis. Circ Arrhythm Electrophysiol. 7, (2), 293-299 (2014).
    • (2014) Circ Arrhythm Electrophysiol , vol.7 , Issue.2 , pp. 293-299
    • Straube, F.1    Dorwarth, U.2    Schmidt, M.3
  • 8
    • 84900452110 scopus 로고    scopus 로고
    • One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon
    • Metzner, A., Reissmann, B., Rausch, P., et al. One-year clinical outcome after pulmonary vein isolation using the second-generation 28-mm cryoballoon. Circ Arrhythm Electrophysiol. 7, (2), 288-292 (2014).
    • (2014) Circ Arrhythm Electrophysiol , vol.7 , Issue.2 , pp. 288-292
    • Metzner, A.1    Reissmann, B.2    Rausch, P.3
  • 9
    • 84905923920 scopus 로고    scopus 로고
    • One-year follow-up after single procedure cryoballoon ablation: A comparison between the first and second generation balloon
    • Giovanni, G. D., Wauters, K., Chierchia, G. B., et al. One-year follow-up after single procedure cryoballoon ablation: A comparison between the first and second generation balloon. J Cardiovasc Electrophysiol. 25, (8), 834-839 (2014).
    • (2014) J Cardiovasc Electrophysiol , vol.25 , Issue.8 , pp. 834-839
    • Giovanni, G.D.1    Wauters, K.2    Chierchia, G.B.3
  • 10
    • 84905859071 scopus 로고    scopus 로고
    • Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation
    • Bordignon, S., Dugo, D., et al. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 25, (8), 840-844 (2014).
    • (2014) J Cardiovasc Electrophysiol , vol.25 , Issue.8 , pp. 840-844
    • Bordignon, S.1    Dugo, D.2
  • 11
    • 84926676443 scopus 로고    scopus 로고
    • Differences of two cryoballoon generations: Insights from the prospective multicentre, multinational FREEZE Cohort Substudy
    • Straube, F., Dorwarth, U., Vogt, J., et al. Differences of two cryoballoon generations: insights from the prospective multicentre, multinational FREEZE Cohort Substudy. Europace. 16, (10), 1434-1442 (2014).
    • (2014) Europace , vol.16 , Issue.10 , pp. 1434-1442
    • Straube, F.1    Dorwarth, U.2    Vogt, J.3
  • 12
    • 77957726642 scopus 로고    scopus 로고
    • Transseptal puncture using minimally invasive echocardiography during atrial fibrillation ablation
    • Mitchell-Heggs, L., Lellouche, N., Deal, L., et al. Transseptal puncture using minimally invasive echocardiography during atrial fibrillation ablation. Europace. 12, (10), 1435-1438 (2010).
    • (2010) Europace , vol.12 , Issue.10 , pp. 1435-1438
    • Mitchell-Heggs, L.1    Lellouche, N.2    Deal, L.3
  • 13
    • 64949092842 scopus 로고    scopus 로고
    • The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: A prospective observational single centre study
    • Chun, K. R., Schmidt, B., Metzner, A., et al. The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study. Eur Heart J. 30, (6), 699-709 (2009).
    • (2009) Eur Heart J , vol.30 , Issue.6 , pp. 699-709
    • Chun, K.R.1    Schmidt, B.2    Metzner, A.3
  • 14
    • 74549189389 scopus 로고    scopus 로고
    • Characterization of conduction recovery after pulmonary vein isolation using the 'single big cryoballoon' technique
    • Chun, K. R., Nuyens, D., et al. Characterization of conduction recovery after pulmonary vein isolation using the 'single big cryoballoon' technique. Heart Rhythm. 7, (2), 184-190 (2010).
    • (2010) Heart Rhythm , vol.7 , Issue.2 , pp. 184-190
    • Chun, K.R.1    Nuyens, D.2
  • 15
    • 79953282950 scopus 로고    scopus 로고
    • A rare complication of radiofrequency catheter ablation of left atrial tachycardia: Atrial septal dissection and left atrial hematoma formation
    • Ciçekçioğlu, H., Diker, E., Aydoğdu, S. A rare complication of radiofrequency catheter ablation of left atrial tachycardia: atrial septal dissection and left atrial hematoma formation. Turk Kardiyol Dern Ars. 38, (4), 279-281 (2010).
    • (2010) Turk Kardiyol Dern Ars , vol.38 , Issue.4 , pp. 279-281
    • Ciçekçioğlu, H.1    Diker, E.2    Aydoğdu, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.