메뉴 건너뛰기




Volumn 10, Issue 8, 2014, Pages 879-885

Home-based diagnosis of obstructive sleep apnea in an urban population

Author keywords

Comparative effectiveness research; OSA; Portable monitoring

Indexed keywords

ADULT; APNEA HYPOPNEA INDEX; AREA UNDER THE CURVE; ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; CROSSOVER PROCEDURE; DIAGNOSTIC ACCURACY; EPWORTH SLEEPINESS SCALE; FEMALE; HOME DIAGNOSTIC TEST; HUMAN; LABORATORY DIAGNOSIS; MAJOR CLINICAL STUDY; MALE; OXYGEN SATURATION; PATIENT MONITORING; PATIENT PREFERENCE; POLYSOMNOGRAPHY; PREDICTIVE VALUE; QUESTIONNAIRE; RANDOMIZED CONTROLLED TRIAL; SENSITIVITY AND SPECIFICITY; SLEEP; SLEEP DISORDERED BREATHING; SLEEP PARAMETERS; URBAN POPULATION; MIDDLE AGED; PHYSIOLOGIC MONITORING; PROCEDURES; SELF CARE; SLEEP APNEA, OBSTRUCTIVE;

EID: 84937122676     PISSN: 15509389     EISSN: 15509397     Source Type: Journal    
DOI: 10.5664/jcsm.3960     Document Type: Article
Times cited : (67)

References (48)
  • 1
    • 77957919992 scopus 로고    scopus 로고
    • Portable-monitor testing: An alternative strategy for managing patients with obstructive sleep apnea
    • Kuna ST. Portable-monitor testing: an alternative strategy for managing patients with obstructive sleep apnea. Respir Care 2010;55:1196-215.
    • (2010) Respir Care , vol.55 , pp. 1196-1215
    • Kuna, S.T.1
  • 2
    • 38849206434 scopus 로고    scopus 로고
    • Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients
    • Portable Monitoring Task Force of the American Academy of Sleep Medicine
    • Collop NA, Anderson WM, Boehlecke B, et al. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2007;3:737-47.
    • (2007) J Clin Sleep Med , vol.3 , pp. 737-747
    • Collop, N.A.1    Anderson, W.M.2    Boehlecke, B.3
  • 3
    • 84875223548 scopus 로고    scopus 로고
    • Portable monitoring for obstructive sleep apnea: The horse is out of the barn-avoiding pitfalls
    • Mohsenin V. Portable monitoring for obstructive sleep apnea: the horse is out of the barn-avoiding pitfalls. Am J Med 2013;126:e1-3.
    • Am J Med , vol.2013
    • Mohsenin, V.1
  • 4
    • 79953712386 scopus 로고    scopus 로고
    • An official ATS/AASM/ACCP/ERS workshop report: Research priorities in ambulatory management of adults with obstructive sleep apnea
    • Kuna ST, Badr MS, Kimoff RJ, et al. An official ATS/AASM/ACCP/ERS workshop report: Research priorities in ambulatory management of adults with obstructive sleep apnea. Proc Am Thorac Soc 2011;8:1-16.
    • (2011) Proc Am Thorac Soc , vol.8 , pp. 1-16
    • Kuna, S.T.1    Badr, M.S.2    Kimoff, R.J.3
  • 5
    • 83255188757 scopus 로고    scopus 로고
    • Canadian Thoracic Society 2011 guideline update: Diagnosis and treatment of sleep disordered breathing
    • Fleetham J, Ayas N, Bradley D, et al. Canadian Thoracic Society 2011 guideline update: diagnosis and treatment of sleep disordered breathing. Can Respir J 2011;18:25-47.
    • (2011) Can Respir J , vol.18 , pp. 25-47
    • Fleetham, J.1    Ayas, N.2    Bradley, D.3
  • 6
    • 79953695937 scopus 로고    scopus 로고
    • Portable monitoring in sleep apnoea: The way forward?
    • McNicholas WT, Levy P. Portable monitoring in sleep apnoea: the way forward? Eur Respir J 2011;37:749-51.
    • (2011) Eur Respir J , vol.37 , pp. 749-751
    • McNicholas, W.T.1    Levy, P.2
  • 7
    • 0142074238 scopus 로고    scopus 로고
    • Home diagnosis of sleep apnea: A systematic review of the literature. An evidence review cosponsored by the American Academy of Sleep Medicine, the American College of Chest Physicians, and the American Thoracic Society
    • Flemons WW, Littner MR, Rowley JA, et al. Home diagnosis of sleep apnea: a systematic review of the literature. An evidence review cosponsored by the American Academy of Sleep Medicine, the American College of Chest Physicians, and the American Thoracic Society. Chest 2003;124:1543-79.
    • (2003) Chest , vol.124 , pp. 1543-1579
    • Flemons, W.W.1    Littner, M.R.2    Rowley, J.A.3
  • 8
    • 1542434613 scopus 로고    scopus 로고
    • Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults
    • American Academy of Sleep Medicine, American Thoracic Society, American College of Chest Physicians
    • Chesson AL, Jr., Berry RB, Pack A, American Academy of Sleep Medicine, American Thoracic Society, American College of Chest Physicians. Practice parameters for the use of portable monitoring devices in the investigation of suspected obstructive sleep apnea in adults. Sleep 2003;26:907-13.
    • (2003) Sleep , vol.26 , pp. 907-913
    • Chesson Jr., A.L.1    Berry, R.B.2    Pack, A.3
  • 9
    • 0033527361 scopus 로고    scopus 로고
    • Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome
    • Netzer NC, Stoohs RA, Netzer CM, Clark K, Strohl KP. Using the Berlin Questionnaire to identify patients at risk for the sleep apnea syndrome. Ann Intern Med 1999;131:485-91.
    • (1999) Ann Intern Med , vol.131 , pp. 485-491
    • Netzer, N.C.1    Stoohs, R.A.2    Netzer, C.M.3    Clark, K.4    Strohl, K.P.5
  • 10
    • 84865306069 scopus 로고    scopus 로고
    • Sleep-disordered breathing symptoms among African-Americans in the Jackson Heart Study
    • Fulop T, Hickson DA, Wyatt SB, et al. Sleep-disordered breathing symptoms among African-Americans in the Jackson Heart Study. Sleep Med 2012;13:1039-49.
    • Sleep Med , vol.2012 , Issue.13 , pp. 1039-1049
    • Fulop, T.1    Hickson, D.A.2    Wyatt, S.B.3
  • 13
    • 43549104501 scopus 로고    scopus 로고
    • Monitoring peripheral arterial tone (PAT) to diagnose sleep apnea in the home
    • White DP. Monitoring peripheral arterial tone (PAT) to diagnose sleep apnea in the home. J Clin Sleep Med 2008;4:73.
    • (2008) J Clin Sleep Med , vol.4 , pp. 73
    • White, D.P.1
  • 14
    • 4143081465 scopus 로고    scopus 로고
    • Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: In-laboratory and ambulatory validation
    • Pittman SD, Ayas NT, MacDonald MM, Malhotra A, Fogel RB, White DP. Using a wrist-worn device based on peripheral arterial tonometry to diagnose obstructive sleep apnea: in-laboratory and ambulatory validation. Sleep 2004;27:923-33.
    • (2004) Sleep , vol.27 , pp. 923-933
    • Pittman, S.D.1    Ayas, N.T.2    MacDonald, M.M.3    Malhotra, A.4    Fogel, R.B.5    White, D.P.6
  • 15
    • 0141446369 scopus 로고    scopus 로고
    • Assessment of a wrist-worn device in the detection of obstructive sleep apnea
    • Ayas NT, Pittman S, MacDonald M, White DP. Assessment of a wrist-worn device in the detection of obstructive sleep apnea. Sleep Med 2003;4:435-42.
    • (2003) Sleep Med , vol.4 , pp. 435-442
    • Ayas, N.T.1    Pittman, S.2    MacDonald, M.3    White, D.P.4
  • 16
    • 0034255392 scopus 로고    scopus 로고
    • Rates of sensor loss in unattended home polysomnography: The influence of age, gender, obesity, and sleep-disordered breathing
    • Kapur VK, Rapoport DM, Sanders MH, et al. Rates of sensor loss in unattended home polysomnography: the influence of age, gender, obesity, and sleep-disordered breathing. Sleep 2000;23:682-8.
    • (2000) Sleep , vol.23 , pp. 682-688
    • Kapur, V.K.1    Rapoport, D.M.2    Sanders, M.H.3
  • 17
    • 0030844917 scopus 로고    scopus 로고
    • Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices
    • Obuchowski NA, McClish DK. Sample size determination for diagnostic accuracy studies involving binormal ROC curve indices. Stat Med 1997;16:1529-42.
    • (1997) Stat Med , vol.16 , pp. 1529-1542
    • Obuchowski, N.A.1    McClish, D.K.2
  • 18
    • 77149123313 scopus 로고    scopus 로고
    • Initial use of portable monitoring versus polysomnography to confirm obstructive sleep apnea in symptomatic patients: An economic decision model
    • Ayas NT, Fox J, Epstein L, Ryan CF, Fleetham JA. Initial use of portable monitoring versus polysomnography to confirm obstructive sleep apnea in symptomatic patients: an economic decision model. Sleep Med 2010;11:320-4.
    • (2010) Sleep Med , vol.11 , pp. 320-324
    • Ayas, N.T.1    Fox, J.2    Epstein, L.3    Ryan, C.F.4    Fleetham, J.A.5
  • 19
    • 33745785255 scopus 로고    scopus 로고
    • Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography
    • Zou D, Grote L, Peker Y, Lindblad U, Hedner J. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Sleep 2006;29:367-74.
    • (2006) Sleep , vol.29 , pp. 367-374
    • Zou, D.1    Grote, L.2    Peker, Y.3    Lindblad, U.4    Hedner, J.5
  • 20
    • 0142105857 scopus 로고    scopus 로고
    • Measuring agreement between diagnostic devices
    • Flemons WW, Littner MR. Measuring agreement between diagnostic devices. Chest 2003;124:1535-42.
    • (2003) Chest , vol.124 , pp. 1535-1542
    • Flemons, W.W.1    Littner, M.R.2
  • 21
    • 77954759987 scopus 로고    scopus 로고
    • Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography
    • Prasad B, Carley DW, Herdegen JJ. Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography. Sleep Breath 2010;14:101-7.
    • (2010) Sleep Breath , vol.14 , pp. 101-107
    • Prasad, B.1    Carley, D.W.2    Herdegen, J.J.3
  • 23
    • 0023710206 scopus 로고
    • Comparing the areas under two or more correlated receiver operating characteristic curves: A nonparametric approach
    • DeLong E, DeLong, DM, Clarke-Pearson, DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988;44:837-45.
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.1    DeLong, D.M.2    Clarke-Pearson, D.L.3
  • 24
    • 0034660296 scopus 로고    scopus 로고
    • Systematic review and meta-analysis of the literature regarding the diagnosis of sleep apnea
    • Ross SD, Sheinhait IA, Harrison KJ, et al. Systematic review and meta-analysis of the literature regarding the diagnosis of sleep apnea. Sleep 2000;23:519-32.
    • (2000) Sleep , vol.23 , pp. 519-532
    • Ross, S.D.1    Sheinhait, I.A.2    Harrison, K.J.3
  • 25
    • 0023769482 scopus 로고
    • A general regression methodology for ROC curve estimation
    • Tosteson AN, Begg CB. A general regression methodology for ROC curve estimation. Med Decis Making 1988;8:204-15.
    • (1988) Med Decis Making , vol.8 , pp. 204-215
    • Tosteson, A.N.1    Begg, C.B.2
  • 27
    • 67651158911 scopus 로고    scopus 로고
    • Development of the FOSQ-10: A short version of the Functional Outcomes of Sleep Questionnaire
    • Chasens ER, Ratcliffe SJ, Weaver TE. Development of the FOSQ-10: a short version of the Functional Outcomes of Sleep Questionnaire. Sleep 2009;32:915-9.
    • (2009) Sleep , vol.32 , pp. 915-919
    • Chasens, E.R.1    Ratcliffe, S.J.2    Weaver, T.E.3
  • 28
    • 84867123842 scopus 로고    scopus 로고
    • Continuous positive airway pressure treatment of sleepy patients with milder obstructive sleep apnea: Results of the CPAP Apnea Trial North American Program (CATNAP) randomized clinical trial
    • Weaver TE, Mancini C, Maislin G, et al. Continuous positive airway pressure treatment of sleepy patients with milder obstructive sleep apnea: results of the CPAP Apnea Trial North American Program (CATNAP) randomized clinical trial. Am J Respir Crit Care Med 2012;186:677-83.
    • Am J Respir Crit Care Med , vol.2012 , Issue.186 , pp. 677-683
    • Weaver, T.E.1    Mancini, C.2    Maislin, G.3
  • 29
    • 79955491551 scopus 로고    scopus 로고
    • Noninferiority of functional outcome in ambulatory management of obstructive sleep apnea
    • Kuna ST, Gurubhagavatula I, Maislin G, et al. Noninferiority of functional outcome in ambulatory management of obstructive sleep apnea. Am J Respir Crit Care Med 2011;183:1238-44.
    • (2011) Am J Respir Crit Care Med , vol.183 , pp. 1238-1244
    • Kuna, S.T.1    Gurubhagavatula, I.2    Maislin, G.3
  • 30
    • 33748286726 scopus 로고    scopus 로고
    • Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry
    • Pittman SD, Pillar G, Berry RB, Malhotra A, MacDonald MM, White DP. Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry. Sleep Breath 2006;10:123-31.
    • (2006) Sleep Breath , vol.10 , pp. 123-131
    • Pittman, S.D.1    Pillar, G.2    Berry, R.B.3    Malhotra, A.4    MacDonald, M.M.5    White, D.P.6
  • 33
    • 84876169322 scopus 로고    scopus 로고
    • Beliefs and attitudes toward obstructive sleep apnea evaluation and treatment among blacks
    • Shaw R, McKenzie S, Taylor T, et al. Beliefs and attitudes toward obstructive sleep apnea evaluation and treatment among blacks. J Natl Med Assoc 2012;104:510-9.
    • J Natl Med Assoc , vol.2012 , Issue.104 , pp. 510-519
    • Shaw, R.1    McKenzie, S.2    Taylor, T.3
  • 34
    • 84878036920 scopus 로고    scopus 로고
    • Reliability of the Watch-PAT 200 in detecting sleep apnea in highway bus drivers
    • Yuceege M, Firat H, Demir A, Ardic S. Reliability of the Watch-PAT 200 in detecting sleep apnea in highway bus drivers. J Clin Sleep Med 2013;9:339-44.
    • J Clin Sleep Med , vol.2013 , Issue.9 , pp. 339-344
    • Yuceege, M.1    Firat, H.2    Demir, A.3    Ardic, S.4
  • 35
    • 85027944881 scopus 로고    scopus 로고
    • Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea
    • Weimin L, Rongguang W, Dongyan H, Xiaoli L, Wei J, Shiming Y. Assessment of a portable monitoring device WatchPAT 200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 2013;270:3099-105.
    • Eur Arch Otorhinolaryngol , vol.2013 , Issue.270 , pp. 3099-3105
    • Weimin, L.1    Rongguang, W.2    Dongyan, H.3    Xiaoli, L.4    Wei, J.5    Shiming, Y.6
  • 36
    • 84868111909 scopus 로고    scopus 로고
    • Rules for scoring respiratory events in sleep: Update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine
    • Berry RB, Budhiraja R, Gottlieb DJ, et al. Rules for scoring respiratory events in sleep: update of the 2007 AASM Manual for the Scoring of Sleep and Associated Events. Deliberations of the Sleep Apnea Definitions Task Force of the American Academy of Sleep Medicine. J Clin Sleep Med 2012;8:597-619.
    • J Clin Sleep Med , vol.2012 , Issue.8 , pp. 597-619
    • Berry, R.B.1    Budhiraja, R.2    Gottlieb, D.J.3
  • 37
    • 84858613399 scopus 로고    scopus 로고
    • AASM criteria for scoring respiratory events: Interaction between apnea sensor and hypopnea definition
    • Thornton AT, Singh P, Ruehland WR, Rochford PD. AASM criteria for scoring respiratory events: interaction between apnea sensor and hypopnea definition. Sleep 2012;35:425-32.
    • Sleep , vol.2012 , Issue.35 , pp. 425-432
    • Thornton, A.T.1    Singh, P.2    Ruehland, W.R.3    Rochford, P.D.4
  • 38
    • 85133606289 scopus 로고    scopus 로고
    • Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: A systematic review and meta-analysis
    • El Shayeb M, Topfer LA, Stafinski T, Pawluk L, Menon D. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis. CMAJ 2014;186:E25-51.
    • CMAJ , vol.2014
    • El Shayeb, M.1    Topfer, L.A.2    Stafinski, T.3    Pawluk, L.4    Menon, D.5
  • 39
    • 0037114686 scopus 로고    scopus 로고
    • Short-term variability of respiration and sleep during unattended nonlaboratory polysomnography - The Sleep Heart Health Study
    • corrected
    • Quan SF, Griswold ME, Iber C et al. Short-term variability of respiration and sleep during unattended nonlaboratory polysomnography-the Sleep Heart Health Study. [corrected]. Sleep 2002;25:843-9.
    • (2002) Sleep , vol.25 , pp. 843-849
    • Quan, S.F.1    Griswold, M.E.2    Iber, C.3
  • 40
    • 64149098535 scopus 로고    scopus 로고
    • Assessment of the test-retest reliability of laboratory polysomnography
    • Levendowski DJ, Zack N, Rao S, et al. Assessment of the test-retest reliability of laboratory polysomnography. Sleep Breath 2009;13:163-7.
    • (2009) Sleep Breath , vol.13 , pp. 163-167
    • Levendowski, D.J.1    Zack, N.2    Rao, S.3
  • 41
    • 79957948169 scopus 로고    scopus 로고
    • An integrated health-economic analysis of diagnostic and therapeutic strategies in the treatment of moderate-to-severe obstructive sleep apnea
    • Pietzsch JB, Garner A, Cipriano LE, Linehan JH. An integrated health-economic analysis of diagnostic and therapeutic strategies in the treatment of moderate-to-severe obstructive sleep apnea. Sleep 2011;34:695-709.
    • (2011) Sleep , vol.34 , pp. 695-709
    • Pietzsch, J.B.1    Garner, A.2    Cipriano, L.E.3    Linehan, J.H.4
  • 42
    • 80054733291 scopus 로고    scopus 로고
    • Obstructive sleep apnea devices for out-of-center (OOC) testing: Technology evaluation
    • Collop NA, Tracy SL, Kapur V, et al. Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation. J Clin Sleep Med 2011;7:531-48.
    • (2011) J Clin Sleep Med , vol.7 , pp. 531-548
    • Collop, N.A.1    Tracy, S.L.2    Kapur, V.3
  • 43
    • 80054754518 scopus 로고    scopus 로고
    • Identification of patients with sleep disordered breathing: Comparing the four-variable screening tool, STOP, STOP-Bang, and Epworth Sleepiness Scales
    • Silva GE, Vana KD, Goodwin JL, Sherrill DL, Quan SF. Identification of patients with sleep disordered breathing: comparing the four-variable screening tool, STOP, STOP-Bang, and Epworth Sleepiness Scales. J Clin Sleep Med 2011;7:467-72.
    • (2011) J Clin Sleep Med , vol.7 , pp. 467-472
    • Silva, G.E.1    Vana, K.D.2    Goodwin, J.L.3    Sherrill, D.L.4    Quan, S.F.5
  • 44
    • 77953285717 scopus 로고    scopus 로고
    • A systematic review of screening questionnaires for obstructive sleep apnea
    • Abrishami A, Khajehdehi A, Chung F. A systematic review of screening questionnaires for obstructive sleep apnea. Can J Anaesth 2010;57:423-38.
    • (2010) Can J Anaesth , vol.57 , pp. 423-438
    • Abrishami, A.1    Khajehdehi, A.2    Chung, F.3
  • 46
    • 34447284535 scopus 로고    scopus 로고
    • Sleep estimation using wrist actigraphy in adolescents with and without sleep disordered breathing: A comparison of three data modes
    • Johnson NL, Kirchner HL, Rosen CL, et al. Sleep estimation using wrist actigraphy in adolescents with and without sleep disordered breathing: a comparison of three data modes. Sleep 2007;30:899-905.
    • (2007) Sleep , vol.30 , pp. 899-905
    • Johnson, N.L.1    Kirchner, H.L.2    Rosen, C.L.3
  • 47
    • 79959299647 scopus 로고    scopus 로고
    • Sleep staging based on autonomic signals: A multi-center validation study
    • Hedner J, White DP, Malhotra A, et al. Sleep staging based on autonomic signals: a multi-center validation study. J Clin Sleep Med 2011;7:301-6.
    • (2011) J Clin Sleep Med , vol.7 , pp. 301-306
    • Hedner, J.1    White, D.P.2    Malhotra, A.3
  • 48
    • 79751489715 scopus 로고    scopus 로고
    • Home set-up polysomnography in the assessment of suspected obstructive sleep apnea
    • Campbell AJ, Neill AM. Home set-up polysomnography in the assessment of suspected obstructive sleep apnea. J Sleep Res 2011;20:207-13.
    • (2011) J Sleep Res , vol.20 , pp. 207-213
    • Campbell, A.J.1    Neill, A.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.