메뉴 건너뛰기




Volumn 8, Issue 5, 2012, Pages 597-619

Rules for scoring respiratory events in sleep: Update of the 2007 AASM manual for the scoring of sleep and associated events

(14)  Berry, Richard B a   Budhiraja, Rohit b   Gottlieb, Daniel J c   Gozal, David d   Iber, Conrad e   Kapur, Vishesh K f   Marcus, Carole L g   Mehra, Reena h   Parthasarathy, Sairam i   Quan, Stuart F j   Redline, Susan k   Strohl, Kingman P h   Ward, Sally L Davidson l   Tangredi, Michelle M m  


Author keywords

[No Author keywords available]

Indexed keywords

CARBON DIOXIDE; OXYGEN;

EID: 84868111909     PISSN: 15509389     EISSN: 15509397     Source Type: Journal    
DOI: 10.5664/jcsm.2172     Document Type: Article
Times cited : (4041)

References (114)
  • 2
    • 62549085154 scopus 로고    scopus 로고
    • The new AASM criteria for scoring hypopneas: Impact on the apnea hypopnea index
    • Ruehland WR, Rochford PD, O'Donoghue FJ, et al. The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index. Sleep 2009;32:150-7.
    • (2009) Sleep , vol.32 , pp. 150-157
    • Ruehland, W.R.1    Rochford, P.D.2    O'Donoghue, F.J.3
  • 3
    • 78649873048 scopus 로고    scopus 로고
    • Differences in overnight polysomnography scores using the adult and pediatric criteria for respiratory events in adolescents
    • Accardo JA, Shults J, Leonard MB, Traylor J, Marcus CL. Differences in overnight polysomnography scores using the adult and pediatric criteria for respiratory events in adolescents. Sleep 2010;33:1333-9.
    • (2010) Sleep , vol.33 , pp. 1333-1339
    • Accardo, J.A.1    Shults, J.2    Leonard, M.B.3    Traylor, J.4    Marcus, C.L.5
  • 4
    • 84863666521 scopus 로고    scopus 로고
    • The AASM scoring manual four years later
    • Grigg-Damberger MM. The AASM scoring manual four years later. J Clin Sleep Med 2012;8:323-32.
    • (2012) J Clin Sleep Med , vol.8 , pp. 323-332
    • Grigg-Damberger, M.M.1
  • 5
    • 70350270369 scopus 로고    scopus 로고
    • Comparison of hypopnea definitions in lean patients with known obstructive sleep apnea hypopnea syndrome
    • Guilleminault C, Hagen CC, Huynh NT. Comparison of hypopnea definitions in lean patients with known obstructive sleep apnea hypopnea syndrome. Sleep Breath 2009;13:341-7.
    • (2009) Sleep Breath , vol.13 , pp. 341-347
    • Guilleminault, C.1    Hagen, C.C.2    Huynh, N.T.3
  • 6
    • 80054750126 scopus 로고    scopus 로고
    • Validation of a polyvinylidene fluoride impedance sensor for respiratory event classification during polysomnography
    • Koo BB, Drummond C, Surovec S, Johnson N, Marvin SA, Redline S. Validation of a polyvinylidene fluoride impedance sensor for respiratory event classification during polysomnography. J Clin Sleep Med 2011;7:479-85.
    • (2011) J Clin Sleep Med , vol.7 , pp. 479-485
    • Koo, B.B.1    Drummond, C.2    Surovec, S.3    Johnson, N.4    Marvin, S.A.5    Redline, S.6
  • 7
    • 80054733291 scopus 로고    scopus 로고
    • Obstructive sleep apnea devices for out-of-center (OOC) testing: Technology evaluation
    • Collop NA, Tracy SL, Kapur V, Mehra R, et al. Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation. J Clin Sleep Med 2011;5:531-48.
    • (2011) J Clin Sleep Med , vol.5 , pp. 531-548
    • Collop, N.A.1    Tracy, S.L.2    Kapur, V.3    Mehra, R.4
  • 8
    • 34247480972 scopus 로고    scopus 로고
    • The scoring of respiratory events in sleep: Reliability and validity
    • Redline S, Budhiraja R, Kapur V, et al. The scoring of respiratory events in sleep: reliability and validity. J Clin Sleep Med 2007;3:169-200.
    • (2007) J Clin Sleep Med , vol.3 , pp. 169-200
    • Redline, S.1    Budhiraja, R.2    Kapur, V.3
  • 9
    • 0033178851 scopus 로고    scopus 로고
    • Sleep-related breathing disorders in adults: Recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force
    • American Academy of Sleep Medicine Task Force
    • American Academy of Sleep Medicine Task Force. Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research. The Report of an American Academy of Sleep Medicine Task Force. Sleep 1999;22:667-89.
    • (1999) Sleep , vol.22 , pp. 667-689
  • 13
    • 0028168020 scopus 로고
    • Flow limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea
    • Condos R, Norman RG, Krishnasamy I, et al. Flow limitation as a noninvasive assessment of residual upper-airway resistance during continuous positive airway pressure therapy of obstructive sleep apnea. Am J Respir Crit Care Med 1994;150:475-80.
    • (1994) Am J Respir Crit Care Med , vol.150 , pp. 475-480
    • Condos, R.1    Norman, R.G.2    Krishnasamy, I.3
  • 14
    • 47849085832 scopus 로고    scopus 로고
    • Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea
    • Kushida CA, Chediak A, Berry RB, et al. Clinical guidelines for the manual titration of positive airway pressure in patients with obstructive sleep apnea. J Clin Sleep Med 2008;4:157-71.
    • (2008) J Clin Sleep Med , vol.4 , pp. 157-171
    • Kushida, C.A.1    Chediak, A.2    Berry, R.B.3
  • 15
    • 78149338344 scopus 로고    scopus 로고
    • Best clinical practices for the sleep center adjustment of noninvasive positive pressure ventilation (NPPV) in stable chronic alveolar hypoventilation syndromes
    • Berry RB, Chediak A, Brown LK, et al. Best clinical practices for the sleep center adjustment of noninvasive positive pressure ventilation (NPPV) in stable chronic alveolar hypoventilation syndromes. J Clin Sleep Med 2010;6:491-509.
    • (2010) J Clin Sleep Med , vol.6 , pp. 491-509
    • Berry, R.B.1    Chediak, A.2    Brown, L.K.3
  • 16
    • 0028822801 scopus 로고
    • Time-course of stepwise CPAP titration: Behavior of respiratory and neurological variables
    • Montserrat JM, Ballester E, Olivi H, et al. Time-course of stepwise CPAP titration: behavior of respiratory and neurological variables. Am J Respir Crit Care Med 1995;152:1854-959.
    • (1995) Am J Respir Crit Care Med , vol.152 , pp. 1854-1959
    • Montserrat, J.M.1    Ballester, E.2    Olivi, H.3
  • 17
    • 0020314216 scopus 로고
    • The respiratory inductive plethysmograph: A new non-invasive monitor of respiration
    • Cohn MA, Rao AS, Broudy M, et al. The respiratory inductive plethysmograph: a new non-invasive monitor of respiration. Bull Eur Physiopathol Respir 1982:18:643-8.
    • (1982) Bull Eur Physiopathol Respir , vol.18 , pp. 643-648
    • Cohn, M.A.1    Rao, A.S.2    Broudy, M.3
  • 19
    • 10444288829 scopus 로고    scopus 로고
    • Noninvasive monitoring of respiratory mechanics during sleep
    • Farré R, Montserrat JM, Navajas D. Noninvasive monitoring of respiratory mechanics during sleep. Eur Respir J 2004;24:1052-60.
    • (2004) Eur Respir J , vol.24 , pp. 1052-1060
    • Farré, R.1    Montserrat, J.M.2    Navajas, D.3
  • 20
    • 0034061533 scopus 로고    scopus 로고
    • Detection of inspiratory flow limitation during sleep by computer assisted respiratory inductive plethysmography
    • Kaplan V, Zhang JN, Russi EW, Bloch KE. Detection of inspiratory flow limitation during sleep by computer assisted respiratory inductive plethysmography. Eur Respir J 2000;15:570-8.
    • (2000) Eur Respir J , vol.15 , pp. 570-578
    • Kaplan, V.1    Zhang, J.N.2    Russi, E.W.3    Bloch, K.E.4
  • 21
    • 0026742539 scopus 로고
    • Goldman M Accuracy of respiratory inductive plethysmography during wakefulness and sleep in patients with obstructive sleep apnea
    • Cantineau JP, Escourrou P, Sartene R, Gaultier C, Goldman M Accuracy of respiratory inductive plethysmography during wakefulness and sleep in patients with obstructive sleep apnea. Chest 1992;102:1145-51.
    • (1992) Chest , vol.102 , pp. 1145-1151
    • Cantineau, J.P.1    Escourrou, P.2    Sartene, R.3    Gaultier, C.4
  • 23
    • 0035891568 scopus 로고    scopus 로고
    • Accuracy of nasal cannula pressure recordings for assessment of ventilation during sleep
    • Thurnheer R, Xie X, Bloch KE. Accuracy of nasal cannula pressure recordings for assessment of ventilation during sleep. Am J Respir Crit Care Med 2001;146:1914-9.
    • (2001) Am J Respir Crit Care Med , vol.146 , pp. 1914-1919
    • Thurnheer, R.1    Xie, X.2    Bloch, K.E.3
  • 24
    • 0031750697 scopus 로고    scopus 로고
    • Assessment of inspiratory flow limitation invasively and noninvasively during sleep
    • Clark SA, Wilson CR, Satoh M, et al. Assessment of inspiratory flow limitation invasively and noninvasively during sleep. Am J Respir Crit Care Med 1998;158:713-22.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 713-722
    • Clark, S.A.1    Wilson, C.R.2    Satoh, M.3
  • 25
    • 29144451400 scopus 로고    scopus 로고
    • Improved detection of obstructive events in childhood sleep apnoea with the use of the nasal cannula and the differentiated sum signal
    • Griffiths A, Maul J, Wilson A, Stick S. Improved detection of obstructive events in childhood sleep apnoea with the use of the nasal cannula and the differentiated sum signal. J Sleep Res 2005;14:431-6.
    • (2005) J Sleep Res , vol.14 , pp. 431-436
    • Griffiths, A.1    Maul, J.2    Wilson, A.3    Stick, S.4
  • 26
    • 0024501468 scopus 로고
    • Calibration of respiratory inductive plethysmograph during natural breathing
    • Sackner MA, Watson H, Belsito AS, et al. Calibration of respiratory inductive plethysmograph during natural breathing. J Appl Physiol 1989;66:410-20.
    • (1989) J Appl Physiol , vol.66 , pp. 410-420
    • Sackner, M.A.1    Watson, H.2    Belsito, A.S.3
  • 27
    • 0141997171 scopus 로고    scopus 로고
    • Assessment of thoracoabdominal bands to detect respiratory effort-related arousals
    • Masa JF, Corral J, Martin MJ, et al. Assessment of thoracoabdominal bands to detect respiratory effort-related arousals. Eur Resp J 2003;33:661-7.
    • (2003) Eur Resp J , vol.33 , pp. 661-667
    • Masa, J.F.1    Corral, J.2    Martin, M.J.3
  • 28
    • 0032917844 scopus 로고    scopus 로고
    • Accuracy of respiratory inductive plethysmography for the diagnosis of upper airway resistance syndrome
    • Loube DI, Andrada T, Howard RS. Accuracy of respiratory inductive plethysmography for the diagnosis of upper airway resistance syndrome. Chest 1999;115:1333-7.
    • (1999) Chest , vol.115 , pp. 1333-1337
    • Loube, D.I.1    Andrada, T.2    Howard, R.S.3
  • 30
    • 0031408629 scopus 로고    scopus 로고
    • Detection of respiratory events during NPSG: Nasal cannula/pressure sensor versus thermistor
    • Norman RG, Ahmed MM, Walsleben JA, Rapoport DM. Detection of respiratory events during NPSG: nasal cannula/pressure sensor versus thermistor. Sleep 1997;20:1175-84.
    • (1997) Sleep , vol.20 , pp. 1175-1184
    • Norman, R.G.1    Ahmed, M.M.2    Walsleben, J.A.3    Rapoport, D.M.4
  • 31
    • 0034666060 scopus 로고    scopus 로고
    • Non-invasive detection of respiratory effort-related arousals (RERAs) by a nasal cannula/pressure transducer system
    • Ayappa I, Norman RG, Krieger AC, et al. Non-invasive detection of respiratory effort-related arousals (RERAs) by a nasal cannula/pressure transducer system. Sleep 2000;23:763-71.
    • (2000) Sleep , vol.23 , pp. 763-771
    • Ayappa, I.1    Norman, R.G.2    Krieger, A.C.3
  • 32
    • 0035113202 scopus 로고    scopus 로고
    • Performance of nasal prongs in sleep studies
    • Hernandez L, Ballester E, Farre R, et al. Performance of nasal prongs in sleep studies. Chest 2001;119:442-50.
    • (2001) Chest , vol.119 , pp. 442-450
    • Hernandez, L.1    Ballester, E.2    Farre, R.3
  • 33
    • 0031939916 scopus 로고    scopus 로고
    • Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopneas
    • Farré R, Montserrat JM, Rotger M, et al. Accuracy of thermistors and thermocouples as flow-measuring devices for detecting hypopneas. Eur Respir J 1998;11:179-82.
    • (1998) Eur Respir J , vol.11 , pp. 179-182
    • Farré, R.1    Montserrat, J.M.2    Rotger, M.3
  • 34
    • 24944508067 scopus 로고    scopus 로고
    • Comparison of respiratory event detection by a polyvinylidene fluoride film airflow sensor and a pneumotachograph in sleep apnea patients
    • Berry RB, Koch GL, Trautz S, Wagner MH. Comparison of respiratory event detection by a polyvinylidene fluoride film airflow sensor and a pneumotachograph in sleep apnea patients. Chest 2005;128:1331-8.
    • (2005) Chest , vol.128 , pp. 1331-1338
    • Berry, R.B.1    Koch, G.L.2    Trautz, S.3    Wagner, M.H.4
  • 35
    • 58849098679 scopus 로고    scopus 로고
    • Validation of a single-channel airflow monitor for screening of sleep-disordered breathing
    • Nakano H, Tanigawa T, Ohnishi Y, Validation of a single-channel airflow monitor for screening of sleep-disordered breathing. Eur Respir J 2008;32:1060-7.
    • (2008) Eur Respir J , vol.32 , pp. 1060-1067
    • Nakano, H.1    Tanigawa, T.2    Ohnishi, Y.3
  • 36
    • 0035131749 scopus 로고    scopus 로고
    • Relevance of linearizing nasal prongs for assessing hypopneas and flow limitation during sleep
    • Farré R, Rigau J, Montserrat JM, et al. Relevance of linearizing nasal prongs for assessing hypopneas and flow limitation during sleep. Am J Respir Crit Care Med 2001;163:494-7.
    • (2001) Am J Respir Crit Care Med , vol.163 , pp. 494-497
    • Farré, R.1    Rigau, J.2    Montserrat, J.M.3
  • 37
    • 0026068230 scopus 로고
    • Accuracy of respiratory inductance plethysmograph in measuring tidal volume during sleep
    • Whyte KF, Gugger M, Gould GA, et al. Accuracy of respiratory inductance plethysmograph in measuring tidal volume during sleep. J Appl Physiol 1991;71:1866-71.
    • (1991) J Appl Physiol , vol.71 , pp. 1866-1871
    • Whyte, K.F.1    Gugger, M.2    Gould, G.A.3
  • 38
    • 0036682889 scopus 로고    scopus 로고
    • Validation of nasal pressure for the identification of apneas/hypopneas during sleep
    • Heitman SJ, Atkar RS, Hajduk EA, et al. Validation of nasal pressure for the identification of apneas/hypopneas during sleep. Am J Respir Crit Care Med 2002;166:386-91.
    • (2002) Am J Respir Crit Care Med , vol.166 , pp. 386-391
    • Heitman, S.J.1    Atkar, R.S.2    Hajduk, E.A.3
  • 39
    • 0033837113 scopus 로고    scopus 로고
    • Comparison of apnea identified by respiratory inductance plethysmography with that detected by end-tidal CO (2) or thermistor
    • The CHIME Study Group
    • Weese-Mayer DE, Corwin MJ, Peucker MR, et al. Comparison of apnea identified by respiratory inductance plethysmography with that detected by end-tidal CO(2) or thermistor. The CHIME Study Group. Am J Respir Crit Care Med 2000;162(2 Pt 1):471-80.
    • (2000) Am J Respir Crit Care Med , vol.162 , Issue.2 PART 1 , pp. 471-480
    • Weese-Mayer, D.E.1    Corwin, M.J.2    Peucker, M.R.3
  • 40
    • 0022365828 scopus 로고
    • Sleep and respiration: Terminology and methodology
    • West P, Kryger MH. Sleep and respiration: Terminology and methodology. Clin Chest Med 1985;6:706.
    • (1985) Clin Chest Med , vol.6 , pp. 706
    • West, P.1    Kryger, M.H.2
  • 41
    • 0030898184 scopus 로고    scopus 로고
    • Comparison of direct and indirect measurement of respiratory airflow: Implications for hypopneas
    • Berg S, Haight JSJ, Yap V, et al. Comparison of direct and indirect measurement of respiratory airflow: implications for hypopneas. Sleep 1997;20:60-4.
    • (1997) Sleep , vol.20 , pp. 60-64
    • Berg, S.1    Haight, J.S.J.2    Yap, V.3
  • 42
    • 0036213782 scopus 로고    scopus 로고
    • Technical protocol for the use of esophageal manometry in the diagnosis of sleep-related breathing disorders
    • Kushida CA, Giacomini A, Lee MK, Guilleminault C, et al. Technical protocol for the use of esophageal manometry in the diagnosis of sleep-related breathing disorders. Sleep Med 2002;3:163-73.
    • (2002) Sleep Med , vol.3 , pp. 163-173
    • Kushida, C.A.1    Giacomini, A.2    Lee, M.K.3    Guilleminault, C.4
  • 43
    • 0030955123 scopus 로고    scopus 로고
    • Assessment of respiratory effort by means of strain gauges and esophageal pressure swings: A comparative study
    • Boudewyns A, Willemen M, Wagemans M, De Cock W, Van de Heyning P, De Backer W. Assessment of respiratory effort by means of strain gauges and esophageal pressure swings: a comparative study. Sleep 1997;20:168-70.
    • (1997) Sleep , vol.20 , pp. 168-170
    • Boudewyns, A.1    Willemen, M.2    Wagemans, M.3    De Cock, W.4    Van De Heyning, P.5    De Backer, W.6
  • 45
    • 0027672856 scopus 로고
    • Measurement of breath amplitudes: Comparison of three noninvasive respiratory monitors to integrated pneumotachograph
    • Adams JA, Zabaleta IA, Stroh D, Sackner MA. Measurement of breath amplitudes: comparison of three noninvasive respiratory monitors to integrated pneumotachograph. Pediatr Pulmonol 1993;16:254-8.
    • (1993) Pediatr Pulmonol , vol.16 , pp. 254-258
    • Adams, J.A.1    Zabaleta, I.A.2    Stroh, D.3    Sackner, M.A.4
  • 46
    • 0009935803 scopus 로고
    • Non-invasive respiratory monitoring
    • Scharf SM, Cassidy SS, eds. New York: Marcel Dekker
    • Sackner MA, Kreiger BP. Non-invasive respiratory monitoring. In: Scharf SM, Cassidy SS, eds. Heart-lung interactions in health and disease. New York: Marcel Dekker, 1989: 663-805.
    • (1989) Heart-lung Interactions in Health and Disease , pp. 663-805
    • Sackner, M.A.1    Kreiger, B.P.2
  • 47
    • 14644444597 scopus 로고    scopus 로고
    • Comparison of pleural pressure and transcutaneous diaphragmatic electromyogram in obstructive sleep apnea syndrome
    • Stoohs RA, Blum HC, Knaack L, Butsch-von-der-Heydt B, Guilleminault C. Comparison of pleural pressure and transcutaneous diaphragmatic electromyogram in obstructive sleep apnea syndrome. Sleep 2005;28:321-9.
    • (2005) Sleep , vol.28 , pp. 321-329
    • Stoohs, R.A.1    Blum, H.C.2    Knaack, L.3    Butsch-Von-Der-Heydt, B.4    Guilleminault, C.5
  • 49
    • 77956293226 scopus 로고    scopus 로고
    • Misconceptions in reporting oxygen saturation
    • Toffaletti J, Zijlstra WG. Misconceptions in reporting oxygen saturation. Anesth Anal 2007;105:S5-9.
    • (2007) Anesth Anal , vol.105
    • Toffaletti, J.1    Zijlstra, W.G.2
  • 51
  • 53
    • 0028107949 scopus 로고
    • Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep
    • Sanders MH, Kern NB, Costantino JP, et al. Accuracy of end-tidal and transcutaneous PCO2 monitoring during sleep. Chest 1994;106:472-83.
    • (1994) Chest , vol.106 , pp. 472-483
    • Sanders, M.H.1    Kern, N.B.2    Costantino, J.P.3
  • 54
    • 69249245163 scopus 로고    scopus 로고
    • The design, use, and results of transcutaneous carbon dioxide analysis: Current and future directions
    • Eberhard P. The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions. Anesth Analg 2007;195:S48-S52
    • (2007) Anesth Analg , vol.195
    • Eberhard, P.1
  • 55
    • 37549047635 scopus 로고    scopus 로고
    • Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation
    • Storre JH, Steurer B, Kabitz HJ, Dreher M, Windisch W. Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation. Chest 2007;132:1810-6.
    • (2007) Chest , vol.132 , pp. 1810-1816
    • Storre, J.H.1    Steurer, B.2    Kabitz, H.J.3    Dreher, M.4    Windisch, W.5
  • 56
    • 69549135433 scopus 로고    scopus 로고
    • Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea
    • Kasuya Y, Akça O, Sessler DI, Ozaki M, Komatsu R. Accuracy of postoperative end-tidal Pco2 measurements with mainstream and sidestream capnography in non-obese patients and in obese patients with and without obstructive sleep apnea. Anesthesiology 2009;111:609-15.
    • (2009) Anesthesiology , vol.111 , pp. 609-615
    • Kasuya, Y.1    Akça, O.2    Sessler, D.I.3    Ozaki, M.4    Komatsu, R.5
  • 57
    • 79953305687 scopus 로고    scopus 로고
    • Capnography for assessing nocturnal hypoventilation and predicting compliance with subsequent noninvasive ventilation in patients with ALS
    • Kim SM, Park KS, Nam H, et al. Capnography for assessing nocturnal hypoventilation and predicting compliance with subsequent noninvasive ventilation in patients with ALS. PLoS One 2011;6:e17893.
    • (2011) PLoS One , vol.6
    • Kim, S.M.1    Park, K.S.2    Nam, H.3
  • 59
    • 78649936011 scopus 로고    scopus 로고
    • Transcutaneous monitoring as a replacement for arterial pCO2 monitoring during nocturnal non-invasive ventilation
    • Storre JH, Magnet F, Dreher M, et al. Transcutaneous monitoring as a replacement for arterial pCO2 monitoring during nocturnal non-invasive ventilation. Respir Med 2011;105:143-50.
    • (2011) Respir Med , vol.105 , pp. 143-150
    • Storre, J.H.1    Magnet, F.2    Dreher, M.3
  • 60
  • 61
    • 24944543851 scopus 로고    scopus 로고
    • Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea
    • Senn O, Clarenbach CF, Kaplan V, et al. Monitoring carbon dioxide tension and arterial oxygen saturation by a single earlobe sensor in patients with critical illness or sleep apnea. Chest 2005;128:1291-6.
    • (2005) Chest , vol.128 , pp. 1291-1296
    • Senn, O.1    Clarenbach, C.F.2    Kaplan, V.3
  • 62
    • 33845589962 scopus 로고    scopus 로고
    • Transcutaneous carbon dioxide monitoring and capnography during pediatric polysomnography
    • Kirk VG, Batuyong ED, Bohn SG. Transcutaneous carbon dioxide monitoring and capnography during pediatric polysomnography. Sleep 2006;29:1601-8.
    • (2006) Sleep , vol.29 , pp. 1601-1608
    • Kirk, V.G.1    Batuyong, E.D.2    Bohn, S.G.3
  • 63
    • 65749098782 scopus 로고    scopus 로고
    • Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors
    • Hirabayashi M, Fujiwara C, Ohtani N, Kagawa S, Kamide M. Transcutaneous PCO2 monitors are more accurate than end-tidal PCO2 monitors. J Anesth 2009;23:198-202.
    • (2009) J Anesth , vol.23 , pp. 198-202
    • Hirabayashi, M.1    Fujiwara, C.2    Ohtani, N.3    Kagawa, S.4    Kamide, M.5
  • 64
    • 33748456788 scopus 로고    scopus 로고
    • Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: A prospective, clinical comparison with end-tidal monitoring
    • Casati A, Squicciarini G, Malagutti G, et al. Transcutaneous monitoring of partial pressure of carbon dioxide in the elderly patient: a prospective, clinical comparison with end-tidal monitoring. J Clin Anesth 2006;18:436-80.
    • (2006) J Clin Anesth , vol.18 , pp. 436-480
    • Casati, A.1    Squicciarini, G.2    Malagutti, G.3
  • 65
    • 0031410307 scopus 로고    scopus 로고
    • Hypopnea, a floating metric: Implications for prevalence, morbidity estimates, and case finding
    • Redline S, Sanders M. Hypopnea, a floating metric: implications for prevalence, morbidity estimates, and case finding. Sleep 1997;20:1209-17.
    • (1997) Sleep , vol.20 , pp. 1209-1217
    • Redline, S.1    Sanders, M.2
  • 66
    • 0034095374 scopus 로고    scopus 로고
    • Effects of varying approaches for identifying respiratory disturbances on sleep apnea assessment
    • Redline S, Kapur VK, Sanders MH, et al. Effects of varying approaches for identifying respiratory disturbances on sleep apnea assessment. Am J Respir Crit Care Med 2000;161(2 Pt 1):369-74.
    • (2000) Am J Respir Crit Care Med , vol.161 , Issue.2 PART 1 , pp. 369-374
    • Redline, S.1    Kapur, V.K.2    Sanders, M.H.3
  • 67
    • 24644459724 scopus 로고    scopus 로고
    • Polysomnographic predictors of blood pressure and hypertension: Is one index best?
    • Redline S, Min NI, Shahar E, Rapoport D, O'Connor G. Polysomnographic predictors of blood pressure and hypertension: is one index best? Sleep 2005;28:1122-30.
    • (2005) Sleep , vol.28 , pp. 1122-1130
    • Redline, S.1    Min, N.I.2    Shahar, E.3    Rapoport, D.4    O'Connor, G.5
  • 68
    • 0034820337 scopus 로고    scopus 로고
    • Impact of different criteria for defining hypopneas in the apnea-hypopnea index
    • Manser RL, Rochford P, Pierce RJ, Byrnes GB, Campbell DA. Impact of different criteria for defining hypopneas in the apnea-hypopnea index. Chest 2001;120:909-14.
    • (2001) Chest , vol.120 , pp. 909-914
    • Manser, R.L.1    Rochford, P.2    Pierce, R.J.3    Byrnes, G.B.4    Campbell, D.A.5
  • 69
    • 0018750287 scopus 로고
    • Sleep apnea, hypopnea and oxygen desaturation in normal subjects
    • Block AJ, Boysen PG, Wynne JW, et al. Sleep apnea, hypopnea and oxygen desaturation in normal subjects. N Engl J Med 1979;300:513-7.
    • (1979) N Engl J Med , vol.300 , pp. 513-517
    • Block, A.J.1    Boysen, P.G.2    Wynne, J.W.3
  • 70
    • 33646359681 scopus 로고    scopus 로고
    • Association of nocturnal arrhythmias with sleep-disordered breathing: The Sleep Heart Health Study
    • Mehra R, Benjamin EJ, Shahar E, et al. Association of nocturnal arrhythmias with sleep-disordered breathing: The Sleep Heart Health Study. Am J Respir Crit Care Med 2006;173:910-6.
    • (2006) Am J Respir Crit Care Med , vol.173 , pp. 910-916
    • Mehra, R.1    Benjamin, E.J.2    Shahar, E.3
  • 72
    • 67649499939 scopus 로고    scopus 로고
    • Nocturnal arrhythmias across a spectrum of obstructive and central sleep-disordered breathing in older men: Outcomes of sleep disorders in older men (MrOS sleep) study
    • Mehra R, Stone KL, Varosy PD, et al. Nocturnal arrhythmias across a spectrum of obstructive and central sleep-disordered breathing in older men: outcomes of sleep disorders in older men (MrOS sleep) study. Arch Intern Med 2009;169:1147-55.
    • (2009) Arch Intern Med , vol.169 , pp. 1147-1155
    • Mehra, R.1    Stone, K.L.2    Varosy, P.D.3
  • 73
    • 46849107138 scopus 로고    scopus 로고
    • Fasting glycemia in sleep disordered breathing: Lowering the threshold on oxyhemoglobin desaturation
    • Stamatakis K, Sanders MH, Caffo B, et al. Fasting glycemia in sleep disordered breathing: lowering the threshold on oxyhemoglobin desaturation. Sleep 2008;31:1018-24.
    • (2008) Sleep , vol.31 , pp. 1018-1024
    • Stamatakis, K.1    Sanders, M.H.2    Caffo, B.3
  • 74
    • 77954528745 scopus 로고    scopus 로고
    • Obstructive sleep apnea-hypopnea and incident stroke: The sleep heart health study
    • Redline S, Yenokyan G, Gottlieb DJ. Obstructive sleep apnea-hypopnea and incident stroke: the sleep heart health study. Am J Respir Crit Care Med 2010;182:269-77.
    • (2010) Am J Respir Crit Care Med , vol.182 , pp. 269-277
    • Redline, S.1    Yenokyan, G.2    Gottlieb, D.J.3
  • 75
    • 0032211801 scopus 로고    scopus 로고
    • Reliability of scoring respiratory disturbance indices and sleep staging
    • Whitney CW, Gottlieb DJ, Redline S, et al. Reliability of scoring respiratory disturbance indices and sleep staging. Sleep 1998;21:749-57.
    • (1998) Sleep , vol.21 , pp. 749-757
    • Whitney, C.W.1    Gottlieb, D.J.2    Redline, S.3
  • 76
    • 0027213807 scopus 로고
    • A cause of excessive daytime sleepiness. The upper airway resistance syndrome
    • Guilleminault C, Stoohs R, Clerk A, Cetel M, Maistros P. A cause of excessive daytime sleepiness. The upper airway resistance syndrome. Chest 1993;104:781-7.
    • (1993) Chest , vol.104 , pp. 781-787
    • Guilleminault, C.1    Stoohs, R.2    Clerk, A.3    Cetel, M.4    Maistros, P.5
  • 77
    • 34247478581 scopus 로고    scopus 로고
    • The scoring of arousal in sleep: Reliability, validity, and alternatives
    • Bonnet MH, Doghramji K, Roehrs T, et al. The scoring of arousal in sleep: reliability, validity, and alternatives. J Clin Sleep Med 2007;3:133-45.
    • (2007) J Clin Sleep Med , vol.3 , pp. 133-145
    • Bonnet, M.H.1    Doghramji, K.2    Roehrs, T.3
  • 78
    • 0035883701 scopus 로고    scopus 로고
    • Characterization of obstructive nonapneic respiratory events in moderate sleep apnea syndrome
    • Cracowski C, Pepin JL, Wuyam B, Levy P. Characterization of obstructive nonapneic respiratory events in moderate sleep apnea syndrome. Am J Respir Crit Care Med 2001;164:944-8.
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 944-948
    • Cracowski, C.1    Pepin, J.L.2    Wuyam, B.3    Levy, P.4
  • 79
    • 69249102051 scopus 로고    scopus 로고
    • Apnoeic and obstructive nonapnoeic sleep respiratory events
    • Masa JF, Corral J, Teran J, et al. Apnoeic and obstructive nonapnoeic sleep respiratory events. Eur Respir J 2009;34:156-61.
    • (2009) Eur Respir J , vol.34 , pp. 156-161
    • Masa, J.F.1    Corral, J.2    Teran, J.3
  • 80
    • 0032819962 scopus 로고    scopus 로고
    • Relationship of arousals from sleep to sympathetic nervous system activity and BP in obstructive sleep apnea
    • Loredo JS, Ziegler MG, Ancoli-Israel S, et al. Relationship of arousals from sleep to sympathetic nervous system activity and BP in obstructive sleep apnea. Chest 1999;116:655-9.
    • (1999) Chest , vol.116 , pp. 655-659
    • Loredo, J.S.1    Ziegler, M.G.2    Ancoli-Israel, S.3
  • 81
    • 0027523757 scopus 로고
    • Sympathetic-nerve activity during sleep in normal subjects
    • Somers VK, Dyken ME, Mark AL, et al. Sympathetic-nerve activity during sleep in normal subjects. N Engl J Med 1993;328:303-7.
    • (1993) N Engl J Med , vol.328 , pp. 303-307
    • Somers, V.K.1    Dyken, M.E.2    Mark, A.L.3
  • 82
    • 33745130432 scopus 로고    scopus 로고
    • Differences in polysomnography predictors for hypertension and impaired glucose tolerance
    • Sulit L, Storfer-Isser A, Kirchner HL, Redline S. Differences in polysomnography predictors for hypertension and impaired glucose tolerance. Sleep 2006;29:777-83.
    • (2006) Sleep , vol.29 , pp. 777-783
    • Sulit, L.1    Storfer-Isser, A.2    Kirchner, H.L.3    Redline, S.4
  • 83
    • 3543007749 scopus 로고    scopus 로고
    • Sleep-disordered breathing and white matter disease in the brainstem in older adults
    • Ding J, Nieto FJ, Beauchamp NJ Jr., et al. Sleep-disordered breathing and white matter disease in the brainstem in older adults. Sleep 2004;27:474-9.
    • (2004) Sleep , vol.27 , pp. 474-479
    • Ding, J.1    Nieto, F.J.2    Beauchamp Jr., N.J.3
  • 84
    • 79953664146 scopus 로고    scopus 로고
    • Sleep disordered breathing with excessive daytime sleepiness is a risk factor for mortality in older adults
    • Gooneratne NS, Richards KC, Joffe M, et al. Sleep disordered breathing with excessive daytime sleepiness is a risk factor for mortality in older adults. Sleep 2011;34:435-42.
    • (2011) Sleep , vol.34 , pp. 435-442
    • Gooneratne, N.S.1    Richards, K.C.2    Joffe, M.3
  • 85
    • 84155163819 scopus 로고    scopus 로고
    • Associations between sleep architecture and sleep-disordered breathing and cognition in older communitydwelling men: The Osteoporotic Fractures in Men Sleep Study
    • Blackwell T, Yaffe K, Ancoli-Israel S, Redline S, et al. Associations between sleep architecture and sleep-disordered breathing and cognition in older communitydwelling men: the Osteoporotic Fractures in Men Sleep Study. J Am Geriatr Soc 2011;59:2217-25.
    • (2011) J Am Geriatr Soc , vol.59 , pp. 2217-2225
    • Blackwell, T.1    Yaffe, K.2    Ancoli-Israel, S.3    Redline, S.4
  • 86
    • 0022385201 scopus 로고
    • Physiological determinants of nocturnal arterial oxygenation in patients with obstructive sleep apnea
    • Bradley TD, Martinez D, Rutherford R, et al. Physiological determinants of nocturnal arterial oxygenation in patients with obstructive sleep apnea. J Appl Physiol 1985;59:1364-8.
    • (1985) J Appl Physiol , vol.59 , pp. 1364-1368
    • Bradley, T.D.1    Martinez, D.2    Rutherford, R.3
  • 87
    • 70349880544 scopus 로고    scopus 로고
    • The impact of obesity on oxygen desaturation during sleep disordered breathing
    • Peppard PE, Ward NR, Morrell MJ. The impact of obesity on oxygen desaturation during sleep disordered breathing. Am J Respir Crit Care Med 2009;180:788-93.
    • (2009) Am J Respir Crit Care Med , vol.180 , pp. 788-793
    • Peppard, P.E.1    Ward, N.R.2    Morrell, M.J.3
  • 88
    • 84876782995 scopus 로고    scopus 로고
    • Centers For Medicare & Medicaid Services U.S. Department of Health and Human Services, (revision effective date 2/4/2011).
    • Centers for Medicare & Medicaid Services, "LCD for Respiratory Assist Devices (L11504, L5023, L11493)," U.S. Department of Health and Human Services, (revision effective date 2/4/2011).
    • LCD for Respiratory Assist Devices (L11504, L5023, L11493)
  • 89
    • 27744454801 scopus 로고    scopus 로고
    • Continuous positive airway pressure for central sleep apnea and heart failure
    • Bradley TD, Logan AG, Kimoff RJ, et al. Continuous positive airway pressure for central sleep apnea and heart failure. N Engl J Med 2005;353:2025-33.
    • (2005) N Engl J Med , vol.353 , pp. 2025-2033
    • Bradley, T.D.1    Logan, A.G.2    Kimoff, R.J.3
  • 90
    • 0034142392 scopus 로고    scopus 로고
    • Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure
    • Javaheri S. Effects of continuous positive airway pressure on sleep apnea and ventricular irritability in patients with heart failure. Circulation 2000;101:392-7.
    • (2000) Circulation , vol.101 , pp. 392-397
    • Javaheri, S.1
  • 91
    • 0034604274 scopus 로고    scopus 로고
    • Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration
    • Sin DD, Logan AG, Fitzgerald FS, Liu PP, Bradley TD. Effects of continuous positive airway pressure on cardiovascular outcomes in heart failure patients with and without Cheyne-Stokes respiration. Circulation 2000;102:61-6.
    • (2000) Circulation , vol.102 , pp. 61-66
    • Sin, D.D.1    Logan, A.G.2    Fitzgerald, F.S.3    Liu, P.P.4    Bradley, T.D.5
  • 92
    • 0033596937 scopus 로고    scopus 로고
    • Prognostic value of nocturnal Cheyne-Stokes respiration in chronic heart failure
    • Lanfranchi PA, Braghiroli A, Bosimini E, et al. Prognostic value of nocturnal Cheyne-Stokes respiration in chronic heart failure. Circulation 1999;99:1435-40.
    • (1999) Circulation , vol.99 , pp. 1435-1440
    • Lanfranchi, P.A.1    Braghiroli, A.2    Bosimini, E.3
  • 93
    • 77951025075 scopus 로고    scopus 로고
    • Shift in sleep apnoea type in heart failure patients in the CANPAP trial
    • Ryan CM, Floras JS, Logan AG, et al. Shift in sleep apnoea type in heart failure patients in the CANPAP trial. Eur Respir J 2010;35:592-7.
    • (2010) Eur Respir J , vol.35 , pp. 592-597
    • Ryan, C.M.1    Floras, J.S.2    Logan, A.G.3
  • 94
    • 20144389345 scopus 로고    scopus 로고
    • Practice parameters for polysomnography and related procedures: An update for 2005
    • Kushida CA, Littner MR, Morgenthaler TI, et al. Practice parameters for polysomnography and related procedures: an update for 2005. Sleep 2005;28:499-521.
    • (2005) Sleep , vol.28 , pp. 499-521
    • Kushida, C.A.1    Littner, M.R.2    Morgenthaler, T.I.3
  • 95
    • 0032994209 scopus 로고    scopus 로고
    • Indications for positive airway pressure treatment of adult obstructive sleep apnea patients: A consensus statement
    • Loube DI, Gay PC, Strohl KP, Pack AI, White DP, Collop NA. Indications for positive airway pressure treatment of adult obstructive sleep apnea patients: a consensus statement. Chest 1999;115:863-6.
    • (1999) Chest , vol.115 , pp. 863-866
    • Loube, D.I.1    Gay, P.C.2    Strohl, K.P.3    Pack, A.I.4    White, D.P.5    Collop, N.A.6
  • 96
    • 0011319079 scopus 로고
    • Alterations in blood gases during natural sleep and narcolepsy; A correlation with the electroencephalographic stages of sleep
    • Birchfield RI, Sieker HO, Heyman A. Alterations in blood gases during natural sleep and narcolepsy; a correlation with the electroencephalographic stages of sleep. Neurology 1958;8:107-12.
    • (1958) Neurology , vol.8 , pp. 107-112
    • Birchfield, R.I.1    Sieker, H.O.2    Heyman, A.3
  • 97
    • 0014582528 scopus 로고
    • Cardiovascular and respiratory changes during sleep in normal and hypertensive subjects
    • Bristow JD, Honour AJ, Pickering TG, Sleight P. Cardiovascular and respiratory changes during sleep in normal and hypertensive subjects. Cardiovasc Res 1969;3:476-85.
    • (1969) Cardiovasc Res , vol.3 , pp. 476-485
    • Bristow, J.D.1    Honour, A.J.2    Pickering, T.G.3    Sleight, P.4
  • 98
    • 0026447177 scopus 로고
    • Normal polysomnographic values for children and adolescents
    • Marcus CL, Omlin KJ, Basinki DJ, et al. Normal polysomnographic values for children and adolescents. Am Rev Respir Dis 1992;146(5 Pt 1):1235-9.
    • (1992) Am Rev Respir Dis , vol.146 , Issue.5 PART 1 , pp. 1235-1239
    • Marcus, C.L.1    Omlin, K.J.2    Basinki, D.J.3
  • 99
    • 1642380377 scopus 로고    scopus 로고
    • Normal polysomnographic respiratory values in children and adolescents
    • Uliel S, Tauman R, Greenfeld M, Sivan Y. Normal polysomnographic respiratory values in children and adolescents. Chest 2004;125:872-8.
    • (2004) Chest , vol.125 , pp. 872-878
    • Uliel, S.1    Tauman, R.2    Greenfeld, M.3    Sivan, Y.4
  • 100
    • 33645021995 scopus 로고    scopus 로고
    • Polysomnographic characteristics in normal preschool and early school-aged children
    • Montgomery-Downs HE, O'Brien LM, Gulliver TE, Gozal D. Polysomnographic characteristics in normal preschool and early school-aged children. Pediatrics 2006;117:741-53.
    • (2006) Pediatrics , vol.117 , pp. 741-753
    • Montgomery-Downs, H.E.1    O'Brien, L.M.2    Gulliver, T.E.3    Gozal, D.4
  • 101
    • 0023522588 scopus 로고
    • Changes in transcutaneous PCO2 with sleep in normal subjects and in patients with chronic respiratory diseases
    • Midgren B, Hansson L. Changes in transcutaneous PCO2 with sleep in normal subjects and in patients with chronic respiratory diseases. Eur J Respir Dis 1987;71:388-94.
    • (1987) Eur J Respir Dis , vol.71 , pp. 388-394
    • Midgren, B.1    Hansson, L.2
  • 102
    • 0028937818 scopus 로고
    • Changes in total pulmonary resistance and PCO2 between wakefulness and sleep in normal human subjects
    • Morrell MJ, Harty HR, Adams L, et al. Changes in total pulmonary resistance and PCO2 between wakefulness and sleep in normal human subjects. J Appl Physiol 1995;78:1339-49.
    • (1995) J Appl Physiol , vol.78 , pp. 1339-1349
    • Morrell, M.J.1    Harty, H.R.2    Adams, L.3
  • 103
    • 0031179434 scopus 로고    scopus 로고
    • Changes in the arterial PCO2 during a single night's sleep in patients with obstructive sleep apnea
    • Chin K, Hirai M, Kuriyama T, et al. Changes in the arterial PCO2 during a single night's sleep in patients with obstructive sleep apnea. Intern Med 1997;36:454-60.
    • (1997) Intern Med , vol.36 , pp. 454-460
    • Chin, K.1    Hirai, M.2    Kuriyama, T.3
  • 104
    • 0030068831 scopus 로고    scopus 로고
    • Increased mortality associated with Cheyne- Stokes respiration in patients with congestive heart failure
    • Hanly PJ, Zuberi-Khokhar NS. Increased mortality associated with Cheyne- Stokes respiration in patients with congestive heart failure. Am J Respir Crit Care Med 1996;153:272-6.
    • (1996) Am J Respir Crit Care Med , vol.153 , pp. 272-276
    • Hanly, P.J.1    Zuberi-Khokhar, N.S.2
  • 106
    • 75149172688 scopus 로고    scopus 로고
    • Cheyne- Stokes respiration in heart failure: Cycle length is dependent on left ventricular ejection fraction
    • Wedewardt J, Bitter T, Prinz C, Faber L, Horstkotte D, Oldenburg O. Cheyne- Stokes respiration in heart failure: cycle length is dependent on left ventricular ejection fraction. Sleep Med 2010;11:137-42.
    • (2010) Sleep Med , vol.11 , pp. 137-142
    • Wedewardt, J.1    Bitter, T.2    Prinz, C.3    Faber, L.4    Horstkotte, D.5    Oldenburg, O.6
  • 107
    • 58549100482 scopus 로고    scopus 로고
    • Central periodic breathing during sleep in 74 patients with acute ischemic stroke-neurogenic and cardiogenic factors
    • Siccoli MM, Valko PO, Hermann DM, Bassetti CL. Central periodic breathing during sleep in 74 patients with acute ischemic stroke-neurogenic and cardiogenic factors. J Neurol 2008;255:1687-92
    • (2008) J Neurol , vol.255 , pp. 1687-1689
    • Siccoli, M.M.1    Valko, P.O.2    Hermann, D.M.3    Bassetti, C.L.4
  • 108
    • 68949107226 scopus 로고    scopus 로고
    • Sleep-disordered breathing in heart failure with normal left ventricular ejection fraction
    • Bitter T, Faber L, Hering D, Langer C, Horstkotte D, Oldenburg O. Sleep-disordered breathing in heart failure with normal left ventricular ejection fraction. Eur J Heart Fail 2009;11:602-8.
    • (2009) Eur J Heart Fail , vol.11 , pp. 602-608
    • Bitter, T.1    Faber, L.2    Hering, D.3    Langer, C.4    Horstkotte, D.5    Oldenburg, O.6
  • 109
    • 0035895316 scopus 로고    scopus 로고
    • Overnight shift from obstructive to central apneas in patients with heart failure: Role of PCO2 and circulatory delay
    • Tkacova R, Niroumand M, Lorenzi-Filho G, Bradley TD. Overnight shift from obstructive to central apneas in patients with heart failure: role of PCO2 and circulatory delay. Circulation 2001;103:238-43.
    • (2001) Circulation , vol.103 , pp. 238-243
    • Tkacova, R.1    Niroumand, M.2    Lorenzi-Filho, G.3    Bradley, T.D.4
  • 110
    • 25444493121 scopus 로고    scopus 로고
    • Cheyne-Stokes respiration in patients hospitalised for heart failure
    • Sep 20
    • Mared L, Cline C, Erhardt L, et al. Cheyne-Stokes respiration in patients hospitalised for heart failure. Respir Res 2004 Sep 20;5:14.
    • (2004) Respir Res , vol.5 , pp. 14
    • Mared, L.1    Cline, C.2    Erhardt, L.3
  • 111
    • 77949705477 scopus 로고    scopus 로고
    • Implications of Cheyne-Stokes breathing in advanced systolic heart failure
    • Amir O Reisfeld D, Sberro H, et al. Implications of Cheyne-Stokes breathing in advanced systolic heart failure. Clin Cardiol 2010;33:E8-12.
    • (2010) Clin Cardiol , vol.33
    • Amir Reisfeld O, D.1    Sberro, H.2
  • 112
    • 57349181190 scopus 로고    scopus 로고
    • Polysomnographic values in children undergoing puberty: Pediatric vs. adult respiratory rules in adolescents
    • Tapia IE, Karamessinis L, Bandla P, et al. Polysomnographic values in children undergoing puberty: pediatric vs. adult respiratory rules in adolescents. Sleep 2008;31:1737-44.
    • (2008) Sleep , vol.31 , pp. 1737-1744
    • Tapia, I.E.1    Karamessinis, L.2    Bandla, P.3
  • 113
    • 0035795604 scopus 로고    scopus 로고
    • Cardiorespiratory events recorded on home monitors: Comparison of healthy infants with those at increased risk for SIDS
    • Ramanathan R, Corwin MJ, Hunt CE, et al. Cardiorespiratory events recorded on home monitors: comparison of healthy infants with those at increased risk for SIDS. JAMA 2001;285:2199-207.
    • (2001) JAMA , vol.285 , pp. 2199-2207
    • Ramanathan, R.1    Corwin, M.J.2    Hunt, C.E.3
  • 114
    • 0022096004 scopus 로고
    • Apnea and periodic breathing in normal full term infants during the first twelve months
    • Kelly DH, Stellwagen LM, Kaitz E, Shannon DC. Apnea and periodic breathing in normal full term infants during the first twelve months. Pediatr Pulmonol 1985;1:215-9
    • (1985) Pediatr Pulmonol , vol.1 , pp. 215-219
    • Kelly, D.H.1    Stellwagen, L.M.2    Kaitz, E.3    Shannon, D.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.