메뉴 건너뛰기




Volumn 48, Issue 1, 2015, Pages e1-e6

Development of a prediction model and risk score for procedure-related complications in patients undergoing percutaneous computed tomography-guided lung biopsy

Author keywords

Complications; CT guided lung biopsy; Lung tumour; Pneumothorax; Risk score

Indexed keywords

ADULT; AGE; AGED; ARTICLE; BIOPSY NEEDLE; CHEST TUBE; COMPUTER ASSISTED TOMOGRAPHY; CUTTING NEEDLE; FEMALE; GENDER; HEMATOTHORAX; HUMAN; IMAGE GUIDED BIOPSY; LUNG BIOPSY; LUNG HEMORRHAGE; LUNG PARENCHYMA; LUNG VOLUME; MAJOR CLINICAL STUDY; MALE; NEEDLE; OPERATOR; PATIENT HISTORY OF CHEMOTHERAPY; PATIENT HISTORY OF RADIOTHERAPY; PERCUTANEOUS BIOPSY; PNEUMOTHORAX; POWER ANALYSIS; PREDICTION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; RISK ASSESSMENT; RISK FACTOR; THORAX RADIOGRAPHY; WORK EXPERIENCE; ADVERSE EFFECTS; INTERVENTIONAL RADIOLOGY; LUNG; LUNG DISEASE; MIDDLE AGED; PATHOLOGY; PROCEDURES; SEX DIFFERENCE; STATISTICAL MODEL; VERY ELDERLY; YOUNG ADULT;

EID: 84936886734     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezv172     Document Type: Article
Times cited : (37)

References (25)
  • 1
    • 73149114866 scopus 로고    scopus 로고
    • CT-fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge co-axial cutting needles: diagnostic yield and risk factors for diagnostic failure
    • Hiraki T, Mimura H, Gobara H, Shibamoto K, Inoue D, Matsui Y et al. CT-fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge co-axial cutting needles: diagnostic yield and risk factors for diagnostic failure. Chest 2009;136:1612-7.
    • (2009) Chest , vol.136 , pp. 1612-1617
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3    Shibamoto, K.4    Inoue, D.5    Matsui, Y.6
  • 2
    • 20444466557 scopus 로고    scopus 로고
    • Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic considerations
    • Gupta S, Seaberg K, Wallace MJ, Madoff DC, Morello FA Jr, Ahrar K et al. Imaging-guided percutaneous biopsy of mediastinal lesions: different approaches and anatomic considerations. Radiographics 2005;25:763-88.
    • (2005) Radiographics , vol.25 , pp. 763-788
    • Gupta, S.1    Seaberg, K.2    Wallace, M.J.3    Madoff, D.C.4    Morello, F.A.5    Ahrar, K.6
  • 3
    • 65349165823 scopus 로고    scopus 로고
    • EGFR mutations are detected comparably in cytologic and surgical pathology specimens of nonsmall cell lung cancer
    • Smouse JH, Cibas ES, Janne PA, Joshi VA, Zou KH, Lindeman NI. EGFR mutations are detected comparably in cytologic and surgical pathology specimens of nonsmall cell lung cancer. Cancer Cytopathol 2009;117: 67-72.
    • (2009) Cancer Cytopathol , vol.117 , pp. 67-72
    • Smouse, J.H.1    Cibas, E.S.2    Janne, P.A.3    Joshi, V.A.4    Zou, K.H.5    Lindeman, N.I.6
  • 4
    • 3843082728 scopus 로고    scopus 로고
    • Percutaneous CT-guided core needle biopsy versus fine needle aspiration in diagnosing pneumonia and mimics of pneumonia
    • Thanos L, Galani P, Mylona S, Pomoni M, Mpatakis N. Percutaneous CT-guided core needle biopsy versus fine needle aspiration in diagnosing pneumonia and mimics of pneumonia. Cardiovasc Intervent Radiol 2004; 27:329-34.
    • (2004) Cardiovasc Intervent Radiol , vol.27 , pp. 329-334
    • Thanos, L.1    Galani, P.2    Mylona, S.3    Pomoni, M.4    Mpatakis, N.5
  • 5
    • 79959621623 scopus 로고    scopus 로고
    • CT-guided Percutaneous needle biopsy of the chest: preprocedural evaluation and technique
    • Wu C, Maher MM, Shepard JO. CT-guided Percutaneous needle biopsy of the chest: preprocedural evaluation and technique. Am J Roentgenol 2011;196:511-4.
    • (2011) Am J Roentgenol , vol.196 , pp. 511-514
    • Wu, C.1    Maher, M.M.2    Shepard, J.O.3
  • 6
    • 79960497280 scopus 로고    scopus 로고
    • Complications of CT-guided Percutaneous needle biopsy of the chest: prevention and management
    • Wu C, Maher MM, Shepard JO. Complications of CT-guided Percutaneous needle biopsy of the chest: prevention and management. Am J Roentgenol 2011;196:678-82.
    • (2011) Am J Roentgenol , vol.196 , pp. 678-682
    • Wu, C.1    Maher, M.M.2    Shepard, J.O.3
  • 7
    • 0033041451 scopus 로고    scopus 로고
    • Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax
    • Cox JE, Chiles C, McManus CM, Aquino SL, Choplin RH. Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax. Radiology 1999;212:165-8.
    • (1999) Radiology , vol.212 , pp. 165-168
    • Cox, J.E.1    Chiles, C.2    McManus, C.M.3    Aquino, S.L.4    Choplin, R.H.5
  • 9
    • 45849132404 scopus 로고    scopus 로고
    • Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
    • Khan MF, Straub R, Moghaddam SR, Maataoui A, Gurung J, Wagner TOF et al. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 2008;18: 1356-63.
    • (2008) Eur Radiol , vol.18 , pp. 1356-1363
    • Khan, M.F.1    Straub, R.2    Moghaddam, S.R.3    Maataoui, A.4    Gurung, J.5    Wagner, T.O.F.6
  • 10
    • 0141954905 scopus 로고    scopus 로고
    • CT-guided lung biopsy: factors influencing diagnostic yield and complication rate
    • Anderson JM, Murchison J, Patel D. CT-guided lung biopsy: factors influencing diagnostic yield and complication rate. Clinic Radiol 2003;58: 791-7.
    • (2003) Clinic Radiol , vol.58 , pp. 791-797
    • Anderson, J.M.1    Murchison, J.2    Patel, D.3
  • 11
    • 77956054842 scopus 로고    scopus 로고
    • Management of spontaneous pneumothorax: British Thoracic Society pleural disease guideline 2010
    • BTS Pleural Disease Guideline Group.
    • MacDuff A, Arnold A, Harvey J; BTS Pleural Disease Guideline Group. Management of spontaneous pneumothorax: British Thoracic Society pleural disease guideline 2010. Thorax 2010;65:ii18-31.
    • (2010) Thorax , vol.65 , pp. ii18-31
    • MacDuff, A.1    Arnold, A.2    Harvey, J.3
  • 12
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • Yeow KM, Su IH, Pan KT, Tsay PK, Lui KW, Cheung YC et al. Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 2004;126:748-54.
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.M.1    Su, I.H.2    Pan, K.T.3    Tsay, P.K.4    Lui, K.W.5    Cheung, Y.C.6
  • 13
    • 84906733866 scopus 로고    scopus 로고
    • CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage?
    • De Filippo M, Saba L, Silva M, Zagaria R, Concari G, Nizzoli R et al. CT-guided biopsy of pulmonary nodules: is pulmonary hemorrhage a complication or an advantage? Diagn Interv Radiol 2014;20:421-5.
    • (2014) Diagn Interv Radiol , vol.20 , pp. 421-425
    • De Filippo, M.1    Saba, L.2    Silva, M.3    Zagaria, R.4    Concari, G.5    Nizzoli, R.6
  • 15
    • 0036247314 scopus 로고    scopus 로고
    • The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor
    • Saji H, Nakamura H, Tsuchida T, Tsuboi M, Kawate N, Konaka C et al. The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor. Chest 2002;121:1521-6.
    • (2002) Chest , vol.121 , pp. 1521-1526
    • Saji, H.1    Nakamura, H.2    Tsuchida, T.3    Tsuboi, M.4    Kawate, N.5    Konaka, C.6
  • 16
    • 0028227102 scopus 로고
    • Risk of pneumothorax not increased by obstructive lung disease in percutaneous needle biopsy
    • Anderson CL, Crespo JC, Lie TH. Risk of pneumothorax not increased by obstructive lung disease in percutaneous needle biopsy. Chest 1994;105: 1705-8.
    • (1994) Chest , vol.105 , pp. 1705-1708
    • Anderson, C.L.1    Crespo, J.C.2    Lie, T.H.3
  • 17
    • 0029064627 scopus 로고
    • CT-guided automated needle biopsy of the chest
    • Haramati LBC. CT-guided automated needle biopsy of the chest. Am J Roentgenol 1995;165:53-5.
    • (1995) Am J Roentgenol , vol.165 , pp. 53-55
    • Haramati, L.B.C.1
  • 18
    • 0035140373 scopus 로고    scopus 로고
    • Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?
    • Ko JP, Shepard JO, Drucker EA, Aquino SL, Sharma A, Sabloff B et al. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors? Radiology 2001;218:491-6.
    • (2001) Radiology , vol.218 , pp. 491-496
    • Ko, J.P.1    Shepard, J.O.2    Drucker, E.A.3    Aquino, S.L.4    Sharma, A.5    Sabloff, B.6
  • 19
    • 84910034263 scopus 로고    scopus 로고
    • Correlation between collateral ventilation and interlobar lung fissures
    • Diso D, Anile M, Carillo C, Ruberto F, Patella M, Russo E et al. Correlation between collateral ventilation and interlobar lung fissures. Respiration 2014;88:315-9.
    • (2014) Respiration , vol.88 , pp. 315-319
    • Diso, D.1    Anile, M.2    Carillo, C.3    Ruberto, F.4    Patella, M.5    Russo, E.6
  • 21
    • 33344463602 scopus 로고    scopus 로고
    • Pulmonary emphysema: objective quantification at multi-detector row CT-comparison with macroscopic and microscopic morphometry
    • Madani A, Zanen J, de Maertelaer V, Gevenois PA. Pulmonary emphysema: objective quantification at multi-detector row CT-comparison with macroscopic and microscopic morphometry. Radiology 2006;238: 1036-43.
    • (2006) Radiology , vol.238 , pp. 1036-1043
    • Madani, A.1    Zanen, J.2    de Maertelaer, V.3    Gevenois, P.A.4
  • 22
    • 84871333095 scopus 로고    scopus 로고
    • CT-guided percutaneous core needle biopsy for small (=20 mm) pulmonary lesions
    • Li Y, Du Y, Yang HF, Yu JH, Yu JH, Xu XX. CT-guided percutaneous core needle biopsy for small (=20 mm) pulmonary lesions. Clin Radiol 2013;68: 43-8.
    • (2013) Clin Radiol , vol.68 , pp. 43-48
    • Li, Y.1    Du, Y.2    Yang, H.F.3    Yu, J.H.4    Yu, J.H.5    Xu, X.X.6
  • 25
    • 80052964102 scopus 로고    scopus 로고
    • Comparative effectiveness of radial probe endobronchial ultrasound versus CT-guided needle biopsy for evaluation of peripheral pulmonary lesions: a randomized pragmatic trial
    • Steinfort DP, Vincent J, Heinze S, Antippa P, Irving LB. Comparative effectiveness of radial probe endobronchial ultrasound versus CT-guided needle biopsy for evaluation of peripheral pulmonary lesions: a randomized pragmatic trial. Respir Med 2011;105:1704-11.
    • (2011) Respir Med , vol.105 , pp. 1704-1711
    • Steinfort, D.P.1    Vincent, J.2    Heinze, S.3    Antippa, P.4    Irving, L.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.