Does physician experience influence the interpretability of focused echocardiography images performed by a pocket device?

Author keywords

Echocardiography; Efficiency; Prehospital emergency care

Indexed keywords

ADULT; CLINICAL COMPETENCE; DEVICES; DIAGNOSTIC IMAGING; ECHOCARDIOGRAPHY; EMERGENCY; EMERGENCY HEALTH SERVICE; EQUIPMENT DESIGN; FEMALE; HEART LEFT VENTRICLE FUNCTION; HUMAN; IMAGE PROCESSING; MALE; PATHOPHYSIOLOGY; PERICARDIAL EFFUSION; PERSONAL DIGITAL ASSISTANT; PHYSICIAN; PHYSIOLOGY; POINT OF CARE SYSTEM; PROCEDURES; PROSPECTIVE STUDY; STANDARDS;

EID: 84935455861     PISSN: None     EISSN: 17577241     Source Type: Journal    
DOI: 10.1186/s13049-015-0122-2     Document Type: Article
Times cited : (24)

References (25)
  • 2
    • 62549098575 scopus 로고    scopus 로고
    • Emergency ultrasound guidelines
    • American College of Emergency P. Emergency ultrasound guidelines. Ann Emerg Med. 2009;53:550-70.
    • (2009) Ann Emerg Med , vol.53 , pp. 550-570
  • 3
    • 78649502484 scopus 로고    scopus 로고
    • Focused cardiac ultrasound in the emergent setting: a consensus statement of the American society of echocardiography and American college of emergency physicians
    • Labovitz AJ, Noble VE, Bierig M, Goldstein SA, Jones R, Kort S, et al. Focused cardiac ultrasound in the emergent setting: a consensus statement of the American society of echocardiography and American college of emergency physicians. J Am Soc Echocardiography. 2010;23:1225-30.
    • (2010) J Am Soc Echocardiography , vol.23 , pp. 1225-1230
    • Labovitz, A.J.1    Noble, V.E.2    Bierig, M.3    Goldstein, S.A.4    Jones, R.5    Kort, S.6
  • 4
    • 78650188823 scopus 로고    scopus 로고
    • New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners
    • Frederiksen CA, Juhl-Olsen P, Larsen UT, Nielsen DG, Eika B, Sloth E. New pocket echocardiography device is interchangeable with high-end portable system when performed by experienced examiners. Acta Anaesthesiol Scand. 2010;54:1217-23.
    • (2010) Acta Anaesthesiol Scand , vol.54 , pp. 1217-1223
    • Frederiksen, C.A.1    Juhl-Olsen, P.2    Larsen, U.T.3    Nielsen, D.G.4    Eika, B.5    Sloth, E.6
  • 5
    • 84858798948 scopus 로고    scopus 로고
    • Fast track echo of abdominal aortic aneurysm using a real pocket-ultrasound device at bedside
    • Dijos M, Pucheux Y, Lafitte M, Reant P, Prevot A, Mignot A, et al. Fast track echo of abdominal aortic aneurysm using a real pocket-ultrasound device at bedside. Echocardiography. 2012;29:285-90.
    • (2012) Echocardiography , vol.29 , pp. 285-290
    • Dijos, M.1    Pucheux, Y.2    Lafitte, M.3    Reant, P.4    Prevot, A.5    Mignot, A.6
  • 6
    • 84860814478 scopus 로고    scopus 로고
    • Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting
    • Biais M, Carrie C, Delaunay F, Morel N, Revel P, Janvier G. Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting. Crit Care. 2012;16:R82.
    • (2012) Crit Care , vol.16 , pp. R82
    • Biais, M.1    Carrie, C.2    Delaunay, F.3    Morel, N.4    Revel, P.5    Janvier, G.6
  • 7
    • 84891166130 scopus 로고    scopus 로고
    • Effect of prehospital ultrasound on clinical outcomes of non-trauma patients-a systematic review
    • Rudolph SS, Sorensen MK, Svane C, Hesselfeldt R, Steinmetz J. Effect of prehospital ultrasound on clinical outcomes of non-trauma patients-a systematic review. Resuscitation. 2014;85:21-30.
    • (2014) Resuscitation , vol.85 , pp. 21-30
    • Rudolph, S.S.1    Sorensen, M.K.2    Svane, C.3    Hesselfeldt, R.4    Steinmetz, J.5
  • 9
    • 78149371903 scopus 로고    scopus 로고
    • Focused echocardiographic evaluation in life support and peri-resuscitation of emergency patients: a prospective trial
    • Breitkreutz R, Price S, Steiger HV, Seeger FH, Ilper H, Ackermann H, et al. Focused echocardiographic evaluation in life support and peri-resuscitation of emergency patients: a prospective trial. Resuscitation. 2010;81:1527-33.
    • (2010) Resuscitation , vol.81 , pp. 1527-1533
    • Breitkreutz, R.1    Price, S.2    Steiger, H.V.3    Seeger, F.H.4    Ilper, H.5    Ackermann, H.6
  • 12
    • 85047700344 scopus 로고    scopus 로고
    • Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement
    • Jakobsen CJ, Torp P, Sloth E. Perioperative feasibility of imaging the heart and pleura in patients with aortic stenosis undergoing aortic valve replacement. Eur J Anaesthesiol. 2007;24:589-95.
    • (2007) Eur J Anaesthesiol , vol.24 , pp. 589-595
    • Jakobsen, C.J.1    Torp, P.2    Sloth, E.3
  • 13
    • 33749058841 scopus 로고    scopus 로고
    • Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic
    • Brennan JM, Ronan A, Goonewardena S, Blair JE, Hammes M, Shah D, et al. Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Clin J Am Soc Nephrol CJASN. 2006;1:749-53.
    • (2006) Clin J Am Soc Nephrol CJASN , vol.1 , pp. 749-753
    • Brennan, J.M.1    Ronan, A.2    Goonewardena, S.3    Blair, J.E.4    Hammes, M.5    Shah, D.6
  • 14
    • 34748875243 scopus 로고    scopus 로고
    • Focused training for goal-oriented hand-held echocardiography performed by noncardiologist residents in the intensive care unit
    • Vignon P, Dugard A, Abraham J, Belcour D, Gondran G, Pepino F, et al. Focused training for goal-oriented hand-held echocardiography performed by noncardiologist residents in the intensive care unit. Intensive Care Med. 2007;33:1795-9.
    • (2007) Intensive Care Med , vol.33 , pp. 1795-1799
    • Vignon, P.1    Dugard, A.2    Abraham, J.3    Belcour, D.4    Gondran, G.5    Pepino, F.6
  • 15
    • 43449109778 scopus 로고    scopus 로고
    • Hand carried echocardiography screening for LV systolic dysfunction in a pulmonary function laboratory
    • Kirkpatrick JN, Ghani SN, Spencer KT. Hand carried echocardiography screening for LV systolic dysfunction in a pulmonary function laboratory. Eur J Echocardiography. 2008;9:381-3.
    • (2008) Eur J Echocardiography , vol.9 , pp. 381-383
    • Kirkpatrick, J.N.1    Ghani, S.N.2    pencer, K.T.3
  • 17
    • 0347816076 scopus 로고    scopus 로고
    • Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome
    • Lichtenstein D, Goldstein I, Mourgeon E, Cluzel P, Grenier P, Rouby JJ. Comparative diagnostic performances of auscultation, chest radiography, and lung ultrasonography in acute respiratory distress syndrome. Anesthesiology. 2004;100:9-15.
    • (2004) Anesthesiology , vol.100 , pp. 9-15
    • Lichtenstein, D.1    Goldstein, I.2    Mourgeon, E.3    Cluzel, P.4    Grenier, P.5    Rouby, J.J.6
  • 19
    • 84897958453 scopus 로고    scopus 로고
    • Availability and practice of bedside ultrasonography in emergency rooms and prehospital setting: a French survey
    • Bobbia X, Hansel N, Muller L, Claret PG, Moreau A, Genre Grandpierre R, et al. Availability and practice of bedside ultrasonography in emergency rooms and prehospital setting: a French survey. Ann Fr Anesth Reanim. 2014;33:e29-33.
    • (2014) Ann Fr Anesth Reanim , vol.33 , pp. e29-33
    • Bobbia, X.1    Hansel, N.2    Muller, L.3    Claret, P.G.4    Moreau, A.5    Genre Grandpierre, R.6
  • 20
    • 31044452471 scopus 로고    scopus 로고
    • Ultrasonography in community emergency departments in the United States: access to ultrasonography performed by consultants and status of emergency physician-performed ultrasonography
    • Moore CL, Molina AA, Lin H. Ultrasonography in community emergency departments in the United States: access to ultrasonography performed by consultants and status of emergency physician-performed ultrasonography. Ann Emerg Med. 2006;47:147-53.
    • (2006) Ann Emerg Med , vol.47 , pp. 147-153
    • Moore, C.L.1    Molina, A.A.2    Lin, H.3
  • 21
    • 69949154686 scopus 로고    scopus 로고
    • Diffusion and practice of ultrasound in emergency medicine departments in Italy
    • Sofia S, Angelini F, Cianci V, Copetti R, Farina R, Scuderi M. Diffusion and practice of ultrasound in emergency medicine departments in Italy. J Ultrasound. 2009;12:112-7.
    • (2009) J Ultrasound , vol.12 , pp. 112-117
    • Sofia, S.1    Angelini, F.2    Cianci, V.3    Copetti, R.4    Farina, R.5    Scuderi, M.6
  • 22
    • 84896463543 scopus 로고    scopus 로고
    • Point-of-care ultrasound in medical education-stop listening and look
    • Solomon SD, Saldana F. Point-of-care ultrasound in medical education-stop listening and look. N Engl J Med. 2014;370:1083-5.
    • (2014) N Engl J Med , vol.370 , pp. 1083-1085
    • Solomon, S.D.1    Saldana, F.2
  • 23
    • 84890787312 scopus 로고    scopus 로고
    • Right ventricular dilatation on bedside echocardiography performed by emergency physicians aids in the diagnosis of pulmonary embolism
    • Dresden S, Mitchell P, Rahimi L, Leo M, Rubin-Smith J, Bibi S, et al. Right ventricular dilatation on bedside echocardiography performed by emergency physicians aids in the diagnosis of pulmonary embolism. Ann Emerg Med. 2014;63:16-24.
    • (2014) Ann Emerg Med , vol.63 , pp. 16-24
    • Dresden, S.1    Mitchell, P.2    Rahimi, L.3    Leo, M.4    Rubin-Smith, J.5    Bibi, S.6
  • 24
    • 84872249894 scopus 로고    scopus 로고
    • Accuracy of emergency physician-performed ultrasonography in the diagnosis of deep-vein thrombosis: a systematic review and meta-analysis
    • Pomero F, Dentali F, Borretta V, Bonzini M, Melchio R, Douketis JD, et al. Accuracy of emergency physician-performed ultrasonography in the diagnosis of deep-vein thrombosis: a systematic review and meta-analysis. Thromb Haemost. 2013;109:137-45.
    • (2013) Thromb Haemost , vol.109 , pp. 137-145
    • Pomero, F.1    Dentali, F.2    Borretta, V.3    Bonzini, M.4    Melchio, R.5    Douketis, J.D.6
  • 25
    • 84867054087 scopus 로고    scopus 로고
    • Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
    • Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B, et al. Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012;16:R188.
    • (2012) Crit Care , vol.16 , pp. R188
    • Muller, L.1    Bobbia, X.2    Toumi, M.3    Louart, G.4    Molinari, N.5    Ragonnet, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.