메뉴 건너뛰기




Volumn 10, Issue 4, 2014, Pages 583-606

Imaging in forensic radiology: an illustrated guide for postmortem computed tomography technique and protocols

Author keywords

Forensic imaging; PMCT; PMCTA; Postmortem computed tomography; Protocol; Virtopsy; Virtual autopsy

Indexed keywords

AUTOPSY; BONE; CAUSE OF DEATH; COMPUTER ASSISTED TOMOGRAPHY; DENTISTRY; HUMAN; POSTMORTEM CHANGE; PRACTICE GUIDELINE; PREDICTIVE VALUE; PROCEDURES; QUALITY CONTROL; RADIOGRAPHY; REPRODUCIBILITY; STANDARDS; WHOLE BODY IMAGING;

EID: 84934277338     PISSN: 1547769X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s12024-014-9555-6     Document Type: Review
Times cited : (163)

References (88)
  • 1
    • 84876716523 scopus 로고    scopus 로고
    • The rise of forensic and post-mortem radiology—analysis of the literature between the year 2000 and 2011
    • Baglivo M, Winklhofer S, Hatch GM, Ampanozi G, Thali MJ, Ruder TD. The rise of forensic and post-mortem radiology—analysis of the literature between the year 2000 and 2011. JOFRI. 2013;1:3–9.
    • (2013) JOFRI , vol.1 , pp. 3-9
    • Baglivo, M.1    Winklhofer, S.2    Hatch, G.M.3    Ampanozi, G.4    Thali, M.J.5    Ruder, T.D.6
  • 2
    • 85079028009 scopus 로고    scopus 로고
    • Forensic radiology in historical perspective
    • Thali MJ, Viner M, Brogdon BG, (eds), CRC Press, Boca Raton:
    • Brogdon BG. Forensic radiology in historical perspective. In: Thali MJ, Viner M, Brogdon BG, editors. Brogdon’s forensic radiology. 2nd ed. Boca Raton: CRC Press; 2010. p. 3–7.
    • (2010) Brogdon’s forensic radiology , pp. 3-7
    • Brogdon, B.G.1
  • 3
    • 53049092274 scopus 로고    scopus 로고
    • Post-mortem radiology—a new sub-speciality?
    • PID: 18929036
    • O’Donnell C, Woodford N. Post-mortem radiology—a new sub-speciality? Clin Radiol. 2008;63:1189–94.
    • (2008) Clin Radiol , vol.63 , pp. 1189-1194
    • O’Donnell, C.1    Woodford, N.2
  • 4
    • 51649121157 scopus 로고    scopus 로고
    • Forensic institutes across the world place CT or MRI scanners or both into their mortuaries
    • PID: 18695489
    • Rutty GN, Morgan B, O’Donnell C, Leth PM, Thali M. Forensic institutes across the world place CT or MRI scanners or both into their mortuaries. J Trauma. 2008;65:493–4.
    • (2008) J Trauma , vol.65 , pp. 493-494
    • Rutty, G.N.1    Morgan, B.2    O’Donnell, C.3    Leth, P.M.4    Thali, M.5
  • 5
    • 0017778659 scopus 로고
    • A computer-tomographical examination of cranial bullet wounds (author’s transl)
    • PID: 602451
    • Wüllenweber R, Schneider V, Grumme T. A computer-tomographical examination of cranial bullet wounds (author’s transl). Z Rechtsmed. 1977;80(3):227–46.
    • (1977) Z Rechtsmed , vol.80 , Issue.3 , pp. 227-246
    • Wüllenweber, R.1    Schneider, V.2    Grumme, T.3
  • 7
    • 0004007339 scopus 로고    scopus 로고
    • (ed), CRC Press LCC, Boca Raton:
    • Brogdon BG, editor. Forensic radiology. 1st ed. Boca Raton: CRC Press LCC; 1998.
    • (1998) Forensic radiology
    • Brogdon, B.G.1
  • 15
    • 84939929273 scopus 로고    scopus 로고
    • The Virtopsy Project. Accessed 1 June 2013
    • The Virtopsy Project. http://www.virtopsy.com. Accessed 1 June 2013.
  • 16
    • 84883756872 scopus 로고    scopus 로고
    • Virtual autopsy: time for a clinical trial
    • PID: 23435726
    • Pollanen MS, Woodford N. Virtual autopsy: time for a clinical trial. Forensic Sci Med Pathol. 2013;9(3):427–8.
    • (2013) Forensic Sci Med Pathol , vol.9 , Issue.3 , pp. 427-428
    • Pollanen, M.S.1    Woodford, N.2
  • 17
    • 84855852846 scopus 로고    scopus 로고
    • Virtual autopsy as an alternative to traditional medical autopsy in the intensive care unit: a prospective cohort study
    • PID: 22250143
    • Wichmann D, Obbelode F, Vogel H, Hoepker WW, Nierhaus A, Braune S, Sauter G, Pueschel K, Kluge S. Virtual autopsy as an alternative to traditional medical autopsy in the intensive care unit: a prospective cohort study. Ann Intern Med. 2012;156(2):123–30.
    • (2012) Ann Intern Med , vol.156 , Issue.2 , pp. 123-130
    • Wichmann, D.1    Obbelode, F.2    Vogel, H.3    Hoepker, W.W.4    Nierhaus, A.5    Braune, S.6    Sauter, G.7    Pueschel, K.8    Kluge, S.9
  • 18
    • 84867400499 scopus 로고    scopus 로고
    • Virtual CT autopsy in clinical pathology: feasibility in clinical autopsies
    • PID: 22729140
    • Westphal SE, Apitzsch J, Penzkofer T, Mahnken AH, Knüchel R. Virtual CT autopsy in clinical pathology: feasibility in clinical autopsies. Virchows Arch. 2012;461(2):211–9.
    • (2012) Virchows Arch , vol.461 , Issue.2 , pp. 211-219
    • Westphal, S.E.1    Apitzsch, J.2    Penzkofer, T.3    Mahnken, A.H.4    Knüchel, R.5
  • 21
    • 80051570415 scopus 로고    scopus 로고
    • A state-of-the-art pipeline for postmortem CT and MRI visualization: from data acquisition to interactive image interpretation at autopsy
    • PID: 21498285
    • Persson A, Lindblom M, Jackowski C. A state-of-the-art pipeline for postmortem CT and MRI visualization: from data acquisition to interactive image interpretation at autopsy. Acta Radiol. 2011;52(5):522–36.
    • (2011) Acta Radiol , vol.52 , Issue.5 , pp. 522-536
    • Persson, A.1    Lindblom, M.2    Jackowski, C.3
  • 23
    • 34249077020 scopus 로고    scopus 로고
    • Virtual autopsy: two- and three-dimensional multidetector CT findings in drowning with autopsy comparison
    • PID: 17517939
    • Levy AD, Harcke HT, Getz JM, Mallak CT, Caruso JL, Pearse L, Frazier AA, Galvin JR. Virtual autopsy: two- and three-dimensional multidetector CT findings in drowning with autopsy comparison. Radiology. 2007;243(3):862–8.
    • (2007) Radiology , vol.243 , Issue.3 , pp. 862-868
    • Levy, A.D.1    Harcke, H.T.2    Getz, J.M.3    Mallak, C.T.4    Caruso, J.L.5    Pearse, L.6    Frazier, A.A.7    Galvin, J.R.8
  • 24
    • 34147173764 scopus 로고    scopus 로고
    • Autopsy radiography: digital radiographs (DR) vs multidetector computed tomography (MDCT) in high-velocity gunshot-wound victims
    • PID: 17325457
    • Harcke HT, Levy AD, Abbott RM, Mallak CT, Getz JM, Champion HR, Pearse L. Autopsy radiography: digital radiographs (DR) vs multidetector computed tomography (MDCT) in high-velocity gunshot-wound victims. Am J Forensic Med Pathol. 2007;28(1):13–9.
    • (2007) Am J Forensic Med Pathol , vol.28 , Issue.1 , pp. 13-19
    • Harcke, H.T.1    Levy, A.D.2    Abbott, R.M.3    Mallak, C.T.4    Getz, J.M.5    Champion, H.R.6    Pearse, L.7
  • 25
    • 84873710183 scopus 로고    scopus 로고
    • Comparison of whole-body post mortem 3D CT and autopsy evaluation in accidental blunt force traumatic death using the abbreviated injury scale classification
    • PID: 22947431
    • Daly B, Abboud S, Ali Z, Sliker C, Fowler D. Comparison of whole-body post mortem 3D CT and autopsy evaluation in accidental blunt force traumatic death using the abbreviated injury scale classification. Forensic Sci Int. 2013;225(1–3):20–6.
    • (2013) Forensic Sci Int , vol.225 , Issue.1-3 , pp. 20-26
    • Daly, B.1    Abboud, S.2    Ali, Z.3    Sliker, C.4    Fowler, D.5
  • 26
    • 84857053247 scopus 로고    scopus 로고
    • The effectiveness of postmortem multidetector computed tomography in the detection of fatal findings related to cause of non-traumatic death in the emergency department
    • PID: 21861187
    • Takahashi N, Higuchi T, Shiotani M, Hirose Y, Shibuya H, Yamanouchi H, Hashidate H, Funayama K. The effectiveness of postmortem multidetector computed tomography in the detection of fatal findings related to cause of non-traumatic death in the emergency department. Eur Radiol. 2012;22(1):152–60.
    • (2012) Eur Radiol , vol.22 , Issue.1 , pp. 152-160
    • Takahashi, N.1    Higuchi, T.2    Shiotani, M.3    Hirose, Y.4    Shibuya, H.5    Yamanouchi, H.6    Hashidate, H.7    Funayama, K.8
  • 27
    • 79952739594 scopus 로고    scopus 로고
    • Postmortem pulmonary edema: a comparison between immediate and delayed postmortem computed tomography
    • Shiotani S, Kobayashi T, Hayakawa H, Kikuchi K, Kohno M. Postmortem pulmonary edema: a comparison between immediate and delayed postmortem computed tomography. Leg Med (Tokyo). 2011;13(3):151–5.
    • (2011) Leg Med (Tokyo) , vol.13 , Issue.3 , pp. 151-155
    • Shiotani, S.1    Kobayashi, T.2    Hayakawa, H.3    Kikuchi, K.4    Kohno, M.5
  • 29
    • 79952204470 scopus 로고    scopus 로고
    • Imaging the dead. Can supplement but not replace autopsy in medicolegal death investigation
    • PID: 21193510
    • O’Donnell CJ, Woodford N. Imaging the dead. Can supplement but not replace autopsy in medicolegal death investigation. BMJ. 2010;341:c7415.
    • (2010) BMJ , vol.341 , pp. c7415
    • O’Donnell, C.J.1    Woodford, N.2
  • 30
    • 84876340960 scopus 로고    scopus 로고
    • Forensic scientist’s implication regarding medical autopsies: experience in a French university hospital (CHU Toulouse)
    • PID: 23582834
    • Capuani C, Guilbeau-Frugier C, Dedouit F, Rougé D, Delisle MB, Telmon N. Forensic scientist’s implication regarding medical autopsies: experience in a French university hospital (CHU Toulouse). Ann Pathol. 2013;33(2):87–92.
    • (2013) Ann Pathol , vol.33 , Issue.2 , pp. 87-92
    • Capuani, C.1    Guilbeau-Frugier, C.2    Dedouit, F.3    Rougé, D.4    Delisle, M.B.5    Telmon, N.6
  • 31
    • 69549091773 scopus 로고    scopus 로고
    • Computerized tomography used as a routine procedure at postmortem investigations
    • PID: 19696574
    • Leth PM. Computerized tomography used as a routine procedure at postmortem investigations. Am J Forensic Med Pathol. 2009;30(3):219–22.
    • (2009) Am J Forensic Med Pathol , vol.30 , Issue.3 , pp. 219-222
    • Leth, P.M.1
  • 32
    • 70350434501 scopus 로고    scopus 로고
    • Report from the medico-legal autopsy of the exhumed corpse of general Władysław Sikorski
    • PID: 19711813
    • Woźniak K, Gross A, Konopka T, Pohl J, Kłys M. Report from the medico-legal autopsy of the exhumed corpse of general Władysław Sikorski. Arch Med Sadowej Kryminol. 2009;59(1):15–21.
    • (2009) Arch Med Sadowej Kryminol , vol.59 , Issue.1 , pp. 15-21
    • Woźniak, K.1    Gross, A.2    Konopka, T.3    Pohl, J.4    Kłys, M.5
  • 33
    • 84883788532 scopus 로고    scopus 로고
    • Different conditions and strategies to utilize forensic radiology in the cities of Melbourne, Australia and Berlin, Germany
    • PID: 23543464
    • Bedford PJ, Oesterhelweg L. Different conditions and strategies to utilize forensic radiology in the cities of Melbourne, Australia and Berlin, Germany. Forensic Sci Med Pathol. 2013;9(3):321–6.
    • (2013) Forensic Sci Med Pathol , vol.9 , Issue.3 , pp. 321-326
    • Bedford, P.J.1    Oesterhelweg, L.2
  • 34
    • 58149154525 scopus 로고    scopus 로고
    • An alternative approach to computerized tomography (CT) in forensic pathology
    • PID: 19070977
    • Thomsen AH, Jurik AG, Uhrenholt L, Vesterby A. An alternative approach to computerized tomography (CT) in forensic pathology. Forensic Sci Int. 2009;183(1–3):87–90.
    • (2009) Forensic Sci Int , vol.183 , Issue.1-3 , pp. 87-90
    • Thomsen, A.H.1    Jurik, A.G.2    Uhrenholt, L.3    Vesterby, A.4
  • 36
    • 84855824360 scopus 로고    scopus 로고
    • To image or to autopsy?
    • PID: 22250149
    • Burton EC, Mossa-Basha M. To image or to autopsy? Ann Intern Med. 2012;156(2):158–9.
    • (2012) Ann Intern Med , vol.156 , Issue.2 , pp. 158-159
    • Burton, E.C.1    Mossa-Basha, M.2
  • 37
    • 77955091643 scopus 로고    scopus 로고
    • Clinical radiology and postmortem imaging (Virtopsy) are not the same: specific and unspecific postmortem signs
    • Christe A, Flach P, Ross S, Spendlove D, Bolliger S, Vock P, Thali MJ. Clinical radiology and postmortem imaging (Virtopsy) are not the same: specific and unspecific postmortem signs. Leg Med (Tokyo). 2010;12(5):215–22.
    • (2010) Leg Med (Tokyo) , vol.12 , Issue.5 , pp. 215-222
    • Christe, A.1    Flach, P.2    Ross, S.3    Spendlove, D.4    Bolliger, S.5    Vock, P.6    Thali, M.J.7
  • 38
    • 84939929274 scopus 로고    scopus 로고
    • Clinical and Forensic Radiology are not the same Boca Raton, Brogdon’s forensic radiology London, New York, Washington, DC: CRC Press, Taylor & Francis Group
    • Flach PM, Ross SG, Thali MJ. Clinical and Forensic Radiology are not the same. In: Thali MJ, Viner MD, Brogdon BG, editors. Brogdon’s forensic radiology. 2nd ed. Boca Raton, London, New York, Washington, DC: CRC Press, Taylor & Francis Group; 2010. p. 409–440.
    • (2010) , pp. 409-440
    • Flach, P.M.1    Ross, S.G.2    Thali, M.J.3    Thali, M.J.4    Viner, M.D.5    Brogdon, B.G.6
  • 40
    • 24644436515 scopus 로고    scopus 로고
    • Evaluation of a 16-MDCT scanner in an emergency department: initial clinical experience and workflow analysis
    • PID: 15972429
    • Gralla J, Spycher F, Pignolet C, Ozdoba C, Vock P, Hoppe H. Evaluation of a 16-MDCT scanner in an emergency department: initial clinical experience and workflow analysis. AJR. 2005;185:232–8.
    • (2005) AJR , vol.185 , pp. 232-238
    • Gralla, J.1    Spycher, F.2    Pignolet, C.3    Ozdoba, C.4    Vock, P.5    Hoppe, H.6
  • 41
    • 0032732933 scopus 로고    scopus 로고
    • Helical CT in emergency radiology
    • COI: 1:STN:280:DC%2BD3c%2FhvV2jtA%3D%3D, PID: 10551209
    • Novelline RA, Rhea JT, Rao PM, Stuk JL. Helical CT in emergency radiology. Radiology. 1999;213:321–39.
    • (1999) Radiology , vol.213 , pp. 321-339
    • Novelline, R.A.1    Rhea, J.T.2    Rao, P.M.3    Stuk, J.L.4
  • 43
    • 84939929275 scopus 로고    scopus 로고
    • Computed Tomography (CT) Guidelines. Accessed 19 Apr 2013
    • Computed Tomography (CT) Guidelines. http://www.acr.org/Quality-Safety/Standards-Guidelines/Practice-Guidelines-by-Modality/CT. Accessed 19 Apr 2013.
  • 44
    • 80052428533 scopus 로고    scopus 로고
    • Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality
    • PID: 21472460
    • Karlo C, Gnannt R, Frauenfelder T, Leschka S, Brüesch M, Wanner GA, Alkadhi H. Whole-body CT in polytrauma patients: effect of arm positioning on thoracic and abdominal image quality. Emerg Radiol. 2011;18:285–93.
    • (2011) Emerg Radiol , vol.18 , pp. 285-293
    • Karlo, C.1    Gnannt, R.2    Frauenfelder, T.3    Leschka, S.4    Brüesch, M.5    Wanner, G.A.6    Alkadhi, H.7
  • 45
    • 84939929276 scopus 로고    scopus 로고
    • Postmortem Angiography Brogdon’s forensic radiology Boca Raton, London, New York, Washington, DC: CRC Press, Taylor & Francis Group
    • Ross SG, Flach PM, Thali MJ. Postmortem Angiography. In: Thali MJ, Viner MD, Brogdon BG, editors. Brogdon’s forensic radiology. 2nd ed. Boca Raton, London, New York, Washington, DC: CRC Press, Taylor & Francis Group; 2010. p. 449–460.
    • (2010) , pp. 449-460
    • Ross, S.G.1    Flach, P.M.2    Thali, M.J.3    Thali, M.J.4    Viner, M.D.5    Brogdon, B.G.6
  • 46
    • 84862705489 scopus 로고    scopus 로고
    • Sudden death after chest pain: feasibility of virtual autopsy with postmortem CT angiography and biopsy
    • PID: 22570504
    • Ross SG, Thali MJ, Bolliger S, Germerott T, Ruder TD, Flach PM. Sudden death after chest pain: feasibility of virtual autopsy with postmortem CT angiography and biopsy. Radiology. 2012;264(1):250–9.
    • (2012) Radiology , vol.264 , Issue.1 , pp. 250-259
    • Ross, S.G.1    Thali, M.J.2    Bolliger, S.3    Germerott, T.4    Ruder, T.D.5    Flach, P.M.6
  • 47
    • 75149170175 scopus 로고    scopus 로고
    • Postmortem whole-body computed tomography angiography visualizing vascular rupture in a case of fatal car crash
    • PID: 20073614
    • Flach PM, Ross SG, Bolliger SA, Preiss US, Thali MJ, Spendlove D. Postmortem whole-body computed tomography angiography visualizing vascular rupture in a case of fatal car crash. Arch Pathol Lab Med. 2010;134(1):115–9.
    • (2010) Arch Pathol Lab Med , vol.134 , Issue.1 , pp. 115-119
    • Flach, P.M.1    Ross, S.G.2    Bolliger, S.A.3    Preiss, U.S.4    Thali, M.J.5    Spendlove, D.6
  • 48
    • 33847219352 scopus 로고    scopus 로고
    • Postmortem angiography: review of former and current methods
    • PID: 17312075
    • Grabherr S, Djonov V, Yen K, Thali MJ, Dirnhofer R. Postmortem angiography: review of former and current methods. AJR. 2007;188:832–8.
    • (2007) AJR , vol.188 , pp. 832-838
    • Grabherr, S.1    Djonov, V.2    Yen, K.3    Thali, M.J.4    Dirnhofer, R.5
  • 50
    • 41149093071 scopus 로고    scopus 로고
    • Whole body postmortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver
    • PID: 18366581
    • Jackowski C, Persson A, Thali MJ. Whole body postmortem angiography with a high viscosity contrast agent solution using poly ethylene glycol as contrast agent dissolver. J Forensic Sci. 2008;53:465–8.
    • (2008) J Forensic Sci , vol.53 , pp. 465-468
    • Jackowski, C.1    Persson, A.2    Thali, M.J.3
  • 52
    • 79960961547 scopus 로고    scopus 로고
    • Post-mortem computed tomography angiography: past, present and future
    • PID: 21153718
    • Saunders SL, Morgan B, Raj V, Rutty GN. Post-mortem computed tomography angiography: past, present and future. Forensic Sci Med Pathol. 2011;7:271–7.
    • (2011) Forensic Sci Med Pathol , vol.7 , pp. 271-277
    • Saunders, S.L.1    Morgan, B.2    Raj, V.3    Rutty, G.N.4
  • 56
    • 0035148654 scopus 로고    scopus 로고
    • Patriquin L, Kassarjian A, Barish M, Casserley L, O’Brien M, Andry C, Eustace S. Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience. J Magn Reson Imaging. 2001;13(2):277–87. Erratum in: J Magn Reson Imaging 2001 May;13(5):818
    • Patriquin L, Kassarjian A, Barish M, Casserley L, O’Brien M, Andry C, Eustace S. Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience. J Magn Reson Imaging. 2001;13(2):277–87. Erratum in: J Magn Reson Imaging 2001 May;13(5):818.
  • 58
    • 77958574421 scopus 로고    scopus 로고
    • Langkammer C, Krebs N, Goessler W, Scheurer E, Ebner F, Yen K, Fazekas F, Ropele S. Quantitative MR imaging of brain iron: a postmortem validation study. Radiology. 2010;257(2):455–62. Erratum in: Radiology. 2011;258(3):962
    • Langkammer C, Krebs N, Goessler W, Scheurer E, Ebner F, Yen K, Fazekas F, Ropele S. Quantitative MR imaging of brain iron: a postmortem validation study. Radiology. 2010;257(2):455–62. Erratum in: Radiology. 2011;258(3):962.
  • 62
    • 78650906606 scopus 로고    scopus 로고
    • Cause of internal hemorrhage determined after exhumation: report of one case
    • PID: 20594783
    • Dedouit F, Piercecchi-Marti MD, Leonetti G, Rougé D, Telmon N. Cause of internal hemorrhage determined after exhumation: report of one case. Forensic Sci Int. 2011;204(1–3):e20–3.
    • (2011) Forensic Sci Int , vol.204 , Issue.1-3 , pp. e20-e23
    • Dedouit, F.1    Piercecchi-Marti, M.D.2    Leonetti, G.3    Rougé, D.4    Telmon, N.5
  • 63
    • 67849103475 scopus 로고    scopus 로고
    • Multidetector computed tomography findings in deaths with severe burns
    • PID: 19465802
    • Levy AD, Harcke HT, Getz JM, Mallak CT. Multidetector computed tomography findings in deaths with severe burns. Am J Forensic Med Pathol. 2009;30(2):137–41.
    • (2009) Am J Forensic Med Pathol , vol.30 , Issue.2 , pp. 137-141
    • Levy, A.D.1    Harcke, H.T.2    Getz, J.M.3    Mallak, C.T.4
  • 64
    • 80052164766 scopus 로고    scopus 로고
    • Buckle” rib fracture: an artifact following cardio-pulmonary resuscitation detected on postmortem CT
    • Yang KM, Lynch M, O’Donnell C. “Buckle” rib fracture: an artifact following cardio-pulmonary resuscitation detected on postmortem CT. Leg Med (Tokyo). 2011;13(5):233–9.
    • (2011) Leg Med (Tokyo) , vol.13 , Issue.5 , pp. 233-239
    • Yang, K.M.1    Lynch, M.2    O’Donnell, C.3
  • 66
    • 34249857538 scopus 로고    scopus 로고
    • Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT
    • PID: 17495293
    • Lee MJ, Kim S, Lee SA, Song HT, Huh YM, Kim DH, Han SH, Suh JS. Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multi-detector CT. RadioGraphics. 2007;27(3):791–803.
    • (2007) RadioGraphics , vol.27 , Issue.3 , pp. 791-803
    • Lee, M.J.1    Kim, S.2    Lee, S.A.3    Song, H.T.4    Huh, Y.M.5    Kim, D.H.6    Han, S.H.7    Suh, J.S.8
  • 67
    • 69649098336 scopus 로고    scopus 로고
    • Is differentiation of frequently encountered foreign bodies in corpses possible by Hounsfield density measurement?
    • PID: 19627414
    • Bolliger SA, Oesterhelweg L, Spendlove D, Ross S, Thali MJ. Is differentiation of frequently encountered foreign bodies in corpses possible by Hounsfield density measurement? J Forensic Sci. 2009;54(5):1119–22.
    • (2009) J Forensic Sci , vol.54 , Issue.5 , pp. 1119-1122
    • Bolliger, S.A.1    Oesterhelweg, L.2    Spendlove, D.3    Ross, S.4    Thali, M.J.5
  • 68
    • 33745278859 scopus 로고    scopus 로고
    • Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT–3D color encoded automatic discrimination of dental restorations
    • COI: 1:STN:280:DC%2BD28zns1Gntg%3D%3D, PID: 16778631
    • Jackowski C, Lussi A, Classens M, Kilchoer T, Bolliger S, Aghayev E, Criste A, Dirnhofer R, Thali MJ. Extended CT scale overcomes restoration caused streak artifacts for dental identification in CT–3D color encoded automatic discrimination of dental restorations. J Comput Assist Tomogr. 2006;30(3):510–3.
    • (2006) J Comput Assist Tomogr , vol.30 , Issue.3 , pp. 510-513
    • Jackowski, C.1    Lussi, A.2    Classens, M.3    Kilchoer, T.4    Bolliger, S.5    Aghayev, E.6    Criste, A.7    Dirnhofer, R.8    Thali, M.J.9
  • 70
    • 84855206616 scopus 로고    scopus 로고
    • Postmortem 24-h interval computed tomography findings on intrahepatic gas development and changes of liver parenchyma radiopacity
    • COI: 1:STN:280:DC%2BC38%2FpslWnsw%3D%3D, PID: 21862251
    • Fischer F, Grimm J, Kirchhoff C, Reiser MF, Graw M, Kirchhoff S. Postmortem 24-h interval computed tomography findings on intrahepatic gas development and changes of liver parenchyma radiopacity. Forensic Sci Int. 2012;214(1–3):118–23.
    • (2012) Forensic Sci Int , vol.214 , Issue.1-3 , pp. 118-123
    • Fischer, F.1    Grimm, J.2    Kirchhoff, C.3    Reiser, M.F.4    Graw, M.5    Kirchhoff, S.6
  • 71
    • 71449087812 scopus 로고    scopus 로고
    • Progressive gas formation in a deceased person during mortuary storage demonstrated on computed tomography
    • PID: 19669956
    • Singh MK, O’Donnell C, Woodford NW. Progressive gas formation in a deceased person during mortuary storage demonstrated on computed tomography. Forensic Sci Med Pathol. 2009;5(3):236–42.
    • (2009) Forensic Sci Med Pathol , vol.5 , Issue.3 , pp. 236-242
    • Singh, M.K.1    O’Donnell, C.2    Woodford, N.W.3
  • 73
    • 33645220363 scopus 로고    scopus 로고
    • Dental CT imaging as a screening tool for dental profiling: advantages and limitations
    • PID: 16423234
    • Thali MJ, Markwalder T, Jackowski C, Sonnenschein M, Dirnhofer R. Dental CT imaging as a screening tool for dental profiling: advantages and limitations. J Forensic Sci. 2006;51(1):113–9.
    • (2006) J Forensic Sci , vol.51 , Issue.1 , pp. 113-119
    • Thali, M.J.1    Markwalder, T.2    Jackowski, C.3    Sonnenschein, M.4    Dirnhofer, R.5
  • 75
    • 70350714251 scopus 로고    scopus 로고
    • Post-mortem imaging of laryngohyoid fractures in strangulation incidents: first results
    • COI: 1:STN:280:DC%2BD1Mjkslyhsg%3D%3D
    • Kempter M, Ross S, Spendlove D, Flach PM, Preiss U, Thali MJ, Bolliger SA. Post-mortem imaging of laryngohyoid fractures in strangulation incidents: first results. Leg Med (Tokyo). 2009;11(6):267–71.
    • (2009) Leg Med (Tokyo) , vol.11 , Issue.6 , pp. 267-271
    • Kempter, M.1    Ross, S.2    Spendlove, D.3    Flach, P.M.4    Preiss, U.5    Thali, M.J.6    Bolliger, S.A.7
  • 76
    • 76449106400 scopus 로고    scopus 로고
    • Sieswerda-Hoogendoorn T, van Rijn RR. Current techniques in postmortem imaging with specific attention to paediatric applications. Pediatr Radiol. 2010;40(2):141–52; quiz 259
    • Sieswerda-Hoogendoorn T, van Rijn RR. Current techniques in postmortem imaging with specific attention to paediatric applications. Pediatr Radiol. 2010;40(2):141–52; quiz 259.
  • 77
    • 63049130733 scopus 로고    scopus 로고
    • Pediatric skeletal trauma: use of multiplanar reformatted and three-dimensional 64-Row multidetector CT in the emergency department
    • PID: 19168841
    • Fayad LM, Corl F, Fishman EK. Pediatric skeletal trauma: use of multiplanar reformatted and three-dimensional 64-Row multidetector CT in the emergency department. RadioGraphics. 2009;29:135–50.
    • (2009) RadioGraphics , vol.29 , pp. 135-150
    • Fayad, L.M.1    Corl, F.2    Fishman, E.K.3
  • 78
    • 84939929280 scopus 로고    scopus 로고
    • International Society of Forensic Radiology and Imaging (ISFRI). Accessed 1 June 2013
    • International Society of Forensic Radiology and Imaging (ISFRI). http://www.isfri.com. Accessed 1 June 2013.
  • 79
    • 77149146161 scopus 로고    scopus 로고
    • Virtobot–a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy
    • PID: 19806611
    • Ebert LC, Ptacek W, Naether S, Fürst M, Ross S, Buck U, Weber S, Thali M. Virtobot–a multi-functional robotic system for 3D surface scanning and automatic post mortem biopsy. Int J Med Robot. 2010;6(1):18–27.
    • (2010) Int J Med Robot , vol.6 , Issue.1 , pp. 18-27
    • Ebert, L.C.1    Ptacek, W.2    Naether, S.3    Fürst, M.4    Ross, S.5    Buck, U.6    Weber, S.7    Thali, M.8
  • 80
    • 79960631568 scopus 로고    scopus 로고
    • Getting in touch–3D printing in forensic imaging
    • PID: 21602004
    • Ebert LC, Thali MJ, Ross S. Getting in touch–3D printing in forensic imaging. Forensic Sci Int. 2011;211(1–3):e1–6.
    • (2011) Forensic Sci Int , vol.211 , Issue.1-3 , pp. e1-e6
    • Ebert, L.C.1    Thali, M.J.2    Ross, S.3
  • 81
    • 84868238548 scopus 로고    scopus 로고
    • You can’t touch this: touch-free navigation through radiological images
    • PID: 22064490
    • Ebert LC, Hatch G, Ampanozi G, Thali MJ, Ross S. You can’t touch this: touch-free navigation through radiological images. Surg Innov. 2012;19(3):301–7.
    • (2012) Surg Innov , vol.19 , Issue.3 , pp. 301-307
    • Ebert, L.C.1    Hatch, G.2    Ampanozi, G.3    Thali, M.J.4    Ross, S.5
  • 82
    • 80052873251 scopus 로고    scopus 로고
    • Forensic application of postmortem diffusion-weighted and diffusion tensor MR imaging of the human brain in situ
    • COI: 1:STN:280:DC%2BC3MfisVOrtQ%3D%3D, PID: 21659482
    • Scheurer E, Lovblad KO, Kreis R, Maier SE, Boesch C, Dirnhofer R, Yen K. Forensic application of postmortem diffusion-weighted and diffusion tensor MR imaging of the human brain in situ. AJNR. 2011;32(8):1518–24.
    • (2011) AJNR , vol.32 , Issue.8 , pp. 1518-1524
    • Scheurer, E.1    Lovblad, K.O.2    Kreis, R.3    Maier, S.E.4    Boesch, C.5    Dirnhofer, R.6    Yen, K.7
  • 84
    • 84862834900 scopus 로고    scopus 로고
    • Postmortem ventilation: a new method for improved detection of pulmonary pathologies in forensic imaging
    • Germerott T, Flach PM, Preiss US, Ross SG, Thali MJ. Postmortem ventilation: a new method for improved detection of pulmonary pathologies in forensic imaging. Leg Med (Tokyo). 2012;14(5):223–8.
    • (2012) Leg Med (Tokyo) , vol.14 , Issue.5 , pp. 223-228
    • Germerott, T.1    Flach, P.M.2    Preiss, U.S.3    Ross, S.G.4    Thali, M.J.5
  • 87
    • 19144365226 scopus 로고    scopus 로고
    • Statistical evaluation of time-dependent metabolite concentrations: estimation of post-mortem intervals based on in situ 1H-MRS of the brain
    • COI: 1:CAS:528:DC%2BD2MXltlCrs7s%3D, PID: 15578674
    • Scheurer E, Ith M, Dietrich D, Kreis R, Hüsler J, Dirnhofer R, Boesch C. Statistical evaluation of time-dependent metabolite concentrations: estimation of post-mortem intervals based on in situ 1H-MRS of the brain. NMR Biomed. 2005;18(3):163–72.
    • (2005) NMR Biomed , vol.18 , Issue.3 , pp. 163-172
    • Scheurer, E.1    Ith, M.2    Dietrich, D.3    Kreis, R.4    Hüsler, J.5    Dirnhofer, R.6    Boesch, C.7
  • 88
    • 84871919909 scopus 로고    scopus 로고
    • High risk medicolegal autopsies: is a full postmortem examination necessary?
    • PID: 23087327
    • Fryer EP, Traill ZC, Benamore RE, Roberts IS. High risk medicolegal autopsies: is a full postmortem examination necessary? J Clin Pathol. 2013;66(1):1–7.
    • (2013) J Clin Pathol , vol.66 , Issue.1 , pp. 1-7
    • Fryer, E.P.1    Traill, Z.C.2    Benamore, R.E.3    Roberts, I.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.