메뉴 건너뛰기




Volumn 199, Issue 6, 2012, Pages 1186-1192

Postmortem Whole-Body MRI in traumatic causes of death

Author keywords

MRI; Postmortem imaging; Trauma; Virtual autopsy

Indexed keywords

ACCIDENTAL DEATH; AGED; AORTA INJURY; ARM FRACTURE; ARTICLE; AUTOPSY; CAUSE OF DEATH; CLINICAL ARTICLE; CLINICAL PROTOCOL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC IMAGING; DIAGNOSTIC TEST ACCURACY STUDY; FALSE POSITIVE RESULT; FEMALE; HEART RUPTURE; HEMATOMA; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; INFANT; LACERATION; LIVER RUPTURE; LUNG CONTUSION; LUNG PARENCHYMA; MALE; PNEUMOTHORAX; POSTHUMOUS CARE; PRIORITY JOURNAL; RIB FRACTURE; SENSITIVITY AND SPECIFICITY; SKULL INJURY; SPINAL HEMATOMA; SPINE FRACTURE; SPLEEN RUPTURE; STANDARDIZATION; STRANGULATION; SUBARACHNOID HEMORRHAGE; SUBDURAL HEMATOMA; WHOLE BODY MRI;

EID: 84870883477     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.12.8767     Document Type: Article
Times cited : (42)

References (30)
  • 1
    • 0038363346 scopus 로고    scopus 로고
    • Accuracy of magnetic resonance imaging in determining cause of sudden death in adults: Comparison with conventional autopsy
    • DOI 10.1046/j.1365-2559.2003.01614.x
    • Roberts IS, Benbow EW, Bisset R, et al. Accuracy of magnetic resonance imaging in determining cause of sudden death in adults: comparison with conventional autopsy. Histopathology 2003; 42: 424-430 (Pubitemid 36605584)
    • (2003) Histopathology , vol.42 , Issue.5 , pp. 424-430
    • Roberts, I.S.D.1    Benbow, E.W.2    Bisset, R.3    Jenkins, J.P.R.4    Lee, S.H.5    Reid, H.6    Jackson, A.7
  • 3
    • 0025046948 scopus 로고
    • Preautopsy magnetic resonance imaging: Initial experience
    • DOI 10.1016/0730-725X(90)90103-9
    • Ros PR, Li KC, Vo P, Baer H, Staab EV. Preautopsy magnetic resonance imaging: initial experience. Magn Reson Imaging 1990; 8:303-308 (Pubitemid 20319674)
    • (1990) Magnetic Resonance Imaging , vol.8 , Issue.3 , pp. 303-308
    • Ros, P.R.1    Li, K.C.2    Vo, P.3    Baer, H.4    Staab, E.V.5
  • 4
    • 84855858670 scopus 로고    scopus 로고
    • Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: A validation study
    • Roberts IS, Benamore RE, Benbow EW, et al. Post-mortem imaging as an alternative to autopsy in the diagnosis of adult deaths: a validation study. Lancet 2012; 379:136-142
    • (2012) Lancet , vol.379 , pp. 136-142
    • Roberts, I.S.1    Benamore, R.E.2    Benbow, E.W.3
  • 5
    • 77954778115 scopus 로고    scopus 로고
    • Utility of post-mortem autopsy via whole-body imaging: Initial observations comparing MDCT and 3.0 T MRI findings with autopsy findings
    • Cha JG, Kim DH, Kim DH, et al. Utility of post-mortem autopsy via whole-body imaging: initial observations comparing MDCT and 3.0 T MRI findings with autopsy findings. Korean J Radiol 2010; 11:395-406
    • (2010) Korean J Radiol , vol.11 , pp. 395-406
    • Cha, J.G.1    Kim, D.H.2    Kim, D.H.3
  • 6
    • 0035148654 scopus 로고    scopus 로고
    • Postmortem whole-body magnetic resonance imaging as an adjunct to autopsy: Preliminary clinical experience
    • DOI 10.1002/1522-2586(200102)13:2<277::AID-JMRI1040>3.0.CO;2-W
    • Patriquin L, Kassarjian A, Barish M, et al. Post-mortem whole-body magnetic resonance imaging as an adjunct to autopsy: preliminary clinical experience. J Magn Reson Imaging 2001; 13:277-287 (Pubitemid 32066666)
    • (2001) Journal of Magnetic Resonance Imaging , vol.13 , Issue.2 , pp. 277-287
    • Patriquin, L.1    Kassarjian, A.2    O'Brien, M.3    Andry, C.4    Eustace, S.5
  • 7
    • 16344389135 scopus 로고    scopus 로고
    • Post-mortem MRI as an adjunct to fetal or neonatal autopsy
    • DOI 10.1016/S0140-6736(05)74816-9
    • Griffiths PD, Paley MN, Whitby EH. Post-mortem MRI as an adjunct to fetal or neonatal autopsy. Lancet 2005; 365:1271-1273 (Pubitemid 40469660)
    • (2005) Lancet , vol.365 , Issue.9466 , pp. 1271-1273
    • Griffiths, P.D.1    Paley, M.N.J.2    Whitby, E.H.3
  • 8
    • 1642481011 scopus 로고    scopus 로고
    • Introduction of autopsy imaging redefines the concept of autopsy: 37 Cases of clinical experience
    • DOI 10.1046/j.1440-1827.2003.01573.x
    • Ezawa H, Yoneyama R, Kandatsu S, Yoshikawa K, Tsujii H, Harigaya K. Introduction of autopsy imaging redefines the concept of autopsy: 37 cases of clinical experience. Pathol Int 2003; 53:865-873 (Pubitemid 38130315)
    • (2003) Pathology International , vol.53 , Issue.12 , pp. 865-873
    • Ezawa, H.1    Yoneyama, R.2    Kandatsu, S.3    Yoshikawa, K.4    Tsujii, H.5    Harigaya, K.6
  • 9
    • 34548705951 scopus 로고    scopus 로고
    • Post-mortem forensic neuroimaging: Correlation of MSCT and MRI findings with autopsy results
    • Yen K, Lövblad KO, Scheurer E, et al. Post-mortem forensic neuroimaging: correlation of MSCT and MRI findings with autopsy results. Forensic Sci Int 2007; 173:21-3
    • (2007) Forensic Sci Int , vol.173 , pp. 21-23
    • Yen, K.1    Lövblad, K.O.2    Scheurer, E.3
  • 10
    • 85047684278 scopus 로고    scopus 로고
    • Abdominal trauma: Sensitivity and specificity of postmortem noncontrast imaging findings compared with autopsy findings
    • Christe A, Ross S, Oesterhelweg L, et al. Abdominal trauma: sensitivity and specificity of postmortem noncontrast imaging findings compared with autopsy findings. J Trauma 2009; 66:1302-1307
    • (2009) J Trauma , vol.66 , pp. 1302-1307
    • Christe, A.1    Ross, S.2    Oesterhelweg, L.3
  • 12
    • 0034979158 scopus 로고    scopus 로고
    • Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study
    • Barkhausen J, Quick HH, Lauenstein T, et al. Wholebody MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: feasibility study. Radiology 2001; 220: 252-256 (Pubitemid 32577994)
    • (2001) Radiology , vol.220 , Issue.1 , pp. 252-256
    • Barkhausen, J.1    Quick, H.H.2    Lauenstein, T.3    Goyen, M.4    Ruehm, S.G.5    Laub, G.6    Debatin, J.F.7    Ladd, M.E.8
  • 13
    • 33748259463 scopus 로고    scopus 로고
    • Emerging techniques: Whole-body screening and staging with MRI
    • DOI 10.1002/jmri.20666
    • Lauenstein TC, Semelka RC. Emerging techniques: whole-body screening and staging with MRI. J Magn Reson Imaging 2006; 24:489-498 (Pubitemid 44320550)
    • (2006) Journal of Magnetic Resonance Imaging , vol.24 , Issue.3 , pp. 489-498
    • Lauenstein, T.C.1    Semelka, R.C.2
  • 14
    • 33746879532 scopus 로고    scopus 로고
    • Total-body MR-imaging in oncology
    • DOI 10.1007/s00330-006-0199-0
    • Schaefer JF, Schlemmer HP. Total-body MR-imaging in oncology. Eur Radiol 2006; 16:2000-2015 (Pubitemid 44193185)
    • (2006) European Radiology , vol.16 , Issue.9 , pp. 2000-2015
    • Schaefer, J.F.1    Schlemmer, H.-P.W.2
  • 15
    • 33747821382 scopus 로고    scopus 로고
    • Cardiac cine imaging at 3 tesla: Initial experience with a 32-element body-array coil
    • DOI 10.1097/01.rli.0000223896.70095.49, PII 0000442420060800000001
    • Fenchel M, Deshpande VS, Nael K, et al. Cardiac cine imaging at 3 Tesla: initial experience with a 32-element body-array coil. Invest Radiol 2006; 41:601-608 (Pubitemid 44284167)
    • (2006) Investigative Radiology , vol.41 , Issue.8 , pp. 601-608
    • Fenchel, M.1    Deshpande, V.S.2    Nael, K.3    Finn, J.P.4    Miller, S.5    Ruehm, S.6    Laub, G.7
  • 16
    • 28044445671 scopus 로고    scopus 로고
    • High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography: Experience on a 32-channel system
    • DOI 10.1097/01.rli.0000185878.61270.b0
    • Schmidt GP, Baur-Melnyk A, Herzog P, et al. High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomographycomputed tomography: experience on a 32-channel system. Invest Radiol 2005; 40:743-753 (Pubitemid 41690430)
    • (2005) Investigative Radiology , vol.40 , Issue.12 , pp. 743-753
    • Schmidt, G.P.1    Baur-Melnyk, A.2    Herzog, P.3    Schmid, R.4    Tiling, R.5    Schmidt, M.6    Reiser, M.F.7    Schoenberg, S.O.8
  • 17
    • 33749496212 scopus 로고    scopus 로고
    • Virtopsy: Minimally invasive, imaging-guided virtual autopsy
    • DOI 10.1148/rg.265065001
    • Dirnhofer R, Jackowski C, Vock P, Potter K, Thali MJ. Virtopsy: minimally invasive, imaging-guided virtual autopsy. RadioGraphics 2006; 26:1305-1333 (Pubitemid 44518766)
    • (2006) Radiographics , vol.26 , Issue.5 , pp. 1305-1333
    • Dirnhofer, R.1    Jackowski, C.2    Vock, P.3    Potter, K.4    Thali, M.J.5
  • 18
    • 14844293464 scopus 로고    scopus 로고
    • VIRTOPSY - Scientific documentation, reconstruction and animation in forensic: Individual and real 3D data based geo-metric approach including optical body/object surface and radiological CT/MRI scanning
    • JFS2004290
    • Thali MJ, Braun M, Buck U, et al. Virtopsy: scientific documentation, reconstruction and animation in forensic: individual and real 3D data based geo-metric approach including optical body/object surface and radiological CT/MRI scanning. J Forensic Sci 2005; 50:428-442 (Pubitemid 40344270)
    • (2005) Journal of Forensic Sciences , vol.50 , Issue.2 , pp. 428-442
    • Thali, M.J.1    Braun, M.2    Buck, U.3    Aghayev, E.4    Jackowski, C.5    Vock, P.6    Sonnenschein, M.7    Dirnhofer, R.8
  • 20
    • 77649226775 scopus 로고    scopus 로고
    • Characteristic signal intensity changes on postmortem magnetic resonance imaging of the brain
    • Kobayashi T, Shiotani S, Kaga K, et al. Characteristic signal intensity changes on postmortem magnetic resonance imaging of the brain. Jpn J Radiol 2010; 28:8-14
    • (2010) Jpn J Radiol , vol.28 , pp. 8-14
    • Kobayashi, T.1    Shiotani, S.2    Kaga, K.3
  • 21
    • 84860767096 scopus 로고    scopus 로고
    • The influence of body temperature on image contrast in post mortem MRI
    • Ruder TD, Hatch GM, Siegenthaler L, et al. The influence of body temperature on image contrast in post mortem MRI. Eur J Radiol 2012; 81:1366-1370
    • (2012) Eur J Radiol , vol.81 , pp. 1366-1370
    • Ruder, T.D.1    Hatch, G.M.2    Siegenthaler, L.3
  • 22
    • 77955091643 scopus 로고    scopus 로고
    • Clinical radiology and postmortem imaging (virtopsy) are not the same: Specific and unspecific postmortem signs
    • Christe A, Flach P, Ross S, et al. Clinical radiology and postmortem imaging (virtopsy) are not the same: specific and unspecific postmortem signs. Leg Med (Tokyo) 2010; 12:215-222
    • (2010) Leg Med (Tokyo) , vol.12 , pp. 215-222
    • Christe, A.1    Flach, P.2    Ross, S.3
  • 23
    • 77649217790 scopus 로고    scopus 로고
    • Postmortem imaging: MDCT features of postmortem change and decomposition
    • Levy AD, Harcke HT, Mallak CT. Postmortem imaging: MDCT features of postmortem change and decomposition. Am J Forensic Med Pathol 2010; 31:12-17
    • (2010) Am J Forensic Med Pathol , vol.31 , pp. 12-17
    • Levy, A.D.1    Harcke, H.T.2    Mallak, C.T.3
  • 24
    • 0036593006 scopus 로고    scopus 로고
    • Traumatic injuries: Imaging of head injuries
    • DOI 10.1007/s00330-002-1355-9
    • Besenski N. Traumatic injuries: imaging of head injuries. Eur Radiol 2002; 12:1237-1252 (Pubitemid 36940198)
    • (2002) European Radiology , vol.12 , Issue.6 , pp. 1237-1252
    • Besenski, N.1
  • 26
    • 39049156814 scopus 로고    scopus 로고
    • Virtual autopsy using imaging: Bridging radiologic and forensic sciences. A review of the Virtopsy and similar projects
    • DOI 10.1007/s00330-007-0737-4
    • Bolliger SA, Thali MJ, Ross S, Buck U, Naether S, Vock P. Virtual autopsy using imaging: bridging radiologic and forensic sciences: a review of the Virtopsy and similar projects. Eur Radiol 2008; 18:273-282 (Pubitemid 351234046)
    • (2008) European Radiology , vol.18 , Issue.2 , pp. 273-282
    • Bolliger, S.A.1    Thali, M.J.2    Ross, S.3    Buck, U.4    Naether, S.5    Vock, P.6
  • 27
    • 34547673374 scopus 로고    scopus 로고
    • Post-mortem radiological CT identification based on classical ante-mortem X-ray examinations
    • DOI 10.1016/j.forsciint.2006.10.009, PII S0379073806006426
    • Pfaeffli M, Vock P, Dirnhofer R, Braun M, Bolliger SA, Thali MJ. Post-mortem radiological CT identification based on classical ante-mortem x-ray examinations. Forensic Sci Int 2007; 171:111-117 (Pubitemid 47211738)
    • (2007) Forensic Science International , vol.171 , Issue.2-3 , pp. 111-117
    • Pfaeffli, M.1    Vock, P.2    Dirnhofer, R.3    Braun, M.4    Bolliger, S.A.5    Thali, M.J.6
  • 28
    • 79960961547 scopus 로고    scopus 로고
    • Post-mortem computed tomography angiography: Past, present and future
    • Saunders SL, Morgan B, Raj V, Rutty GN. Post-mortem computed tomography angiography: past, present and future. Forensic Sci Med Pathol 2010; 7:271-277
    • (2010) Forensic Sci Med Pathol , vol.7 , pp. 271-277
    • Saunders, S.L.1    Morgan, B.2    Raj, V.3    Rutty, G.N.4
  • 29
    • 79251616150 scopus 로고    scopus 로고
    • Suicidal knife wound to the heart: Challenges in reconstructing wound channels with post mortem CT and CTangiography
    • Ruder TD, Ketterer T, Preiss U, et al. Suicidal knife wound to the heart: challenges in reconstructing wound channels with post mortem CT and CTangiography. Leg Med (Tokyo) 2011; 13: 91-94
    • (2011) Leg Med (Tokyo) , vol.13 , pp. 91-94
    • Ruder, T.D.1    Ketterer, T.2    Preiss, U.3
  • 30
    • 77950371257 scopus 로고    scopus 로고
    • Minimally invasive post-mortem CT-angiography in a case involving a gunshot wound
    • Ruder TD, Ross S, Preiss U, Thali MJ. Minimally invasive post-mortem CT-angiography in a case involving a gunshot wound. Leg Med (Tokyo) 2010; 12:154-156
    • (2010) Leg Med (Tokyo) , vol.12 , pp. 154-156
    • Ruder, T.D.1    Ross, S.2    Preiss, U.3    Thali, M.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.