메뉴 건너뛰기




Volumn 53, Issue 7, 2015, Pages 1083-1089

The clinical performance of a chemiluminescent immunoassay in detecting anti-cardiolipin and anti-β2 glycoprotein i antibodies. A comparison with a homemade ELISA method

Author keywords

anti cardiolipin (aCL) antibodies; anti phospholipid antibodies (aPL); anti phospholipid syndrome (APS); anti 2 glycoprotein I (anti 2GPI) antibodies; chemiluminescence immunoassay (CLIA); enzyme linked immunosorbent assay (ELISA)

Indexed keywords

BETA2 GLYCOPROTEIN 1 ANTIBODY; CARDIOLIPIN ANTIBODY; IMMUNOGLOBULIN G; IMMUNOGLOBULIN G ANTIBODY; IMMUNOGLOBULIN M; IMMUNOGLOBULIN M ANTIBODY; BETA2 GLYCOPROTEIN 1;

EID: 84930801033     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2014-0925     Document Type: Article
Times cited : (38)

References (36)
  • 1
    • 33344458573 scopus 로고    scopus 로고
    • International consensus statement on an update of the classification criteria for definite antiphospholipid syndrome (APS)
    • Miyakis S, Lockshin MD, Atsumi T, Branch DW, Brey RL, Cervera R, et al. International consensus statement on an update of the classification criteria for definite antiphospholipid syndrome (APS). J Thromb Haemost 2006;4:295-306.
    • (2006) J Thromb Haemost , vol.4 , pp. 295-306
    • Miyakis, S.1    Lockshin, M.D.2    Atsumi, T.3    Branch, D.W.4    Brey, R.L.5    Cervera, R.6
  • 3
    • 0345059323 scopus 로고    scopus 로고
    • Seronegative antiphospholipid syndrome
    • Hughes GR, Khamashta MA. Seronegative antiphospholipid syndrome. Ann Rheum Dis 2003;62:1127.
    • (2003) Ann Rheum Dis , vol.62 , pp. 1127
    • Hughes, G.R.1    Khamashta, M.A.2
  • 4
    • 70350004861 scopus 로고    scopus 로고
    • Update of the guidelines for lupus anticoagulant detection
    • Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis
    • Pengo V, Tripodi A, Reber G, Rand JH, Ortel TL, Galli M, et al. Update of the guidelines for lupus anticoagulant detection. Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis. J Thromb Haemost 2009;7:1737-40.
    • (2009) J Thromb Haemost , vol.7 , pp. 1737-1740
    • Pengo, V.1    Tripodi, A.2    Reber, G.3    Rand, J.H.4    Ortel, T.L.5    Galli, M.6
  • 5
    • 84858283382 scopus 로고    scopus 로고
    • British Committee for Standards in Haematology Guidelines on the investigation and management of antiphospholipid syndrome
    • Keeling D, Mackie I, Moore GW, Greer IA, Greaves M. British Committee for Standards in Haematology Guidelines on the investigation and management of antiphospholipid syndrome. Br J Haematol 2012;157:47-58.
    • (2012) Br J Haematol , vol.157 , pp. 47-58
    • Keeling, D.1    MacKie, I.2    Moore, G.W.3    Greer, I.A.4    Greaves, M.5
  • 6
    • 84925982840 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute (CLSI) CLSI document H60-A. Wayne PA: CLSI
    • Clinical and Laboratory Standards Institute (CLSI). Laboratory testing for the lupus anticoagulant; approved Guideline. CLSI document H60-A. Wayne, PA: CLSI, 2014.
    • (2014) Laboratory Testing for the Lupus Anticoagulant; Approved Guideline
  • 7
    • 84961290266 scopus 로고    scopus 로고
    • Antiphospholipid antibody testing for the antiphospholipid syndrome: A synopsis of challenges and recent guidelines
    • Favaloro EJ, Wong RC. Antiphospholipid antibody testing for the antiphospholipid syndrome: a synopsis of challenges and recent guidelines. Pathology 2014;46:481-95.
    • (2014) Pathology , vol.46 , pp. 481-495
    • Favaloro, E.J.1    Wong, R.C.2
  • 8
    • 84896716882 scopus 로고    scopus 로고
    • Standardization and harmonization of antiphospholipid antibody assays
    • Favaloro EJ, Plebani M, Lippi G. Standardization and harmonization of antiphospholipid antibody assays. Semin Thromb Hemost 2014;40:161-2.
    • (2014) Semin Thromb Hemost , vol.40 , pp. 161-162
    • Favaloro, E.J.1    Plebani, M.2    Lippi, G.3
  • 9
    • 13244292209 scopus 로고    scopus 로고
    • Proposals for the measurement of anti-b2-glycoprotein i antibodies
    • Standardization Group of the European Forum on Antiphospholipid Antibodies
    • Reber G, Tincani A, Sanmarco M, de Moerloose P, Boffa MC. Proposals for the measurement of anti-b2-glycoprotein I antibodies. Standardization Group of the European Forum on Antiphospholipid Antibodies. J Thromb Haemost 2004;2:1860-2.
    • (2004) J Thromb Haemost , vol.2 , pp. 1860-1862
    • Reber, G.1    Tincani, A.2    Sanmarco, M.3    De Moerloose, P.4    Boffa, M.C.5
  • 10
    • 7044260448 scopus 로고    scopus 로고
    • Minimal requirements for antiphospholipid antibodies ELISAs proposed by the European Forum on antiphospholipid antibodies
    • Tincani A, Allegri F, Balestrieri G, Reber G, Sanmarco M, Meroni P, et al. Minimal requirements for antiphospholipid antibodies ELISAs proposed by the European Forum on antiphospholipid antibodies. Thromb Res 2004;114:553-8.
    • (2004) Thromb Res , vol.114 , pp. 553-558
    • Tincani, A.1    Allegri, F.2    Balestrieri, G.3    Reber, G.4    Sanmarco, M.5    Meroni, P.6
  • 13
    • 0035985646 scopus 로고    scopus 로고
    • Revisiting the anticardiolipin test and its standardization
    • Harris EN, Pierangeli SS. Revisiting the anticardiolipin test and its standardization. Lupus 2002;11:269-75.
    • (2002) Lupus , vol.11 , pp. 269-275
    • Harris, E.N.1    Pierangeli, S.S.2
  • 14
    • 84855294117 scopus 로고    scopus 로고
    • International consensus guidelines on anticardiolipin and anti-2-glycoprotein i testing: Report from the 13th International Congress on Antiphospholipid Antibodies
    • Lakos G, Favaloro EJ, Harris EN, Meroni PL, Tincani A, Wong RC, et al. International consensus guidelines on anticardiolipin and anti-2-glycoprotein I testing: report from the 13th International Congress on Antiphospholipid Antibodies. Arthritis Rheum 2012;64:1-10.
    • (2012) Arthritis Rheum , vol.64 , pp. 1-10
    • Lakos, G.1    Favaloro, E.J.2    Harris, E.N.3    Meroni, P.L.4    Tincani, A.5    Wong, R.C.6
  • 15
    • 82955173886 scopus 로고    scopus 로고
    • Standards and reference materials for the anticardiolipin and anti-2glycoprotein i assays: A report of recommendations from the APL Task Force at the 13th International Congress on Antiphospholipid Antibodies
    • Pierangeli SS, Favaloro EJ, Lakos G, Meroni PL, Tincani A, Wong RC. Standards and reference materials for the anticardiolipin and anti-2glycoprotein I assays: a report of recommendations from the APL Task Force at the 13th International Congress on Antiphospholipid Antibodies. Clin Chim Act 2012;413:358-60.
    • (2012) Clin Chim Act , vol.413 , pp. 358-360
    • Pierangeli, S.S.1    Favaloro, E.J.2    Lakos, G.3    Meroni, P.L.4    Tincani, A.5    Wong, R.C.6
  • 16
    • 50249154439 scopus 로고    scopus 로고
    • A quarter of a century in anticardiolipin antibody testing and attempted standardization has led us to here which is Semin
    • Pierangeli SS, Harris EN. A quarter of a century in anticardiolipin antibody testing and attempted standardization has led us to here, which is Semin Thromb Hemost 2008;34:313-28.
    • (2008) Thromb Hemost , vol.34 , pp. 313-328
    • Pierangeli, S.S.1    Harris, E.N.2
  • 17
    • 50249150452 scopus 로고    scopus 로고
    • Technical aspects in laboratory testing for antiphospholipid antibodies: Is standardization an impossible dream
    • Reber G, Boehlen F, de Moerloose P. Technical aspects in laboratory testing for antiphospholipid antibodies: is standardization an impossible dream Semin Thromb Hemost 2008;34:340-6.
    • (2008) Semin Thromb Hemost , vol.34 , pp. 340-346
    • Reber, G.1    Boehlen, F.2    De Moerloose, P.3
  • 18
    • 11144353893 scopus 로고    scopus 로고
    • A multi-centre evaluation of the intra-assay and inter-assay variation of commercial and in-house anti-cardiolipin antibody assays
    • Wong R, Favaloro E, Pollock W, Wilson R, Hendle M, Adelstein S. A multi-centre evaluation of the intra-assay and inter-assay variation of commercial and in-house anti-cardiolipin antibody assays. Pathology 2004;36:182-92.
    • (2004) Pathology , vol.36 , pp. 182-192
    • Wong, R.1    Favaloro, E.2    Pollock, W.3    Wilson, R.4    Hendle, M.5    Adelstein, S.6
  • 19
  • 20
    • 84856216805 scopus 로고    scopus 로고
    • Analytical chemiluminescence and bioluminescence: Latest achievements and new horizons
    • Roda A, Guardigli M. Analytical chemiluminescence and bioluminescence: latest achievements and new horizons. Anal Bioanal Chem 2012;402:69-76.
    • (2012) Anal Bioanal Chem , vol.402 , pp. 69-76
    • Roda, A.1    Guardigli, M.2
  • 22
    • 50249135024 scopus 로고    scopus 로고
    • Are the current attempts at standardization of antiphospholipid antibodies still useful Emerging technologies signal a shift in direction
    • Andreoli L, Rizzini S, Allegri F, Meroni P, Tincani A. Are the current attempts at standardization of antiphospholipid antibodies still useful Emerging technologies signal a shift in direction. Semin Thromb Hemost 2008;34:356-60.
    • (2008) Semin Thromb Hemost , vol.34 , pp. 356-360
    • Andreoli, L.1    Rizzini, S.2    Allegri, F.3    Meroni, P.4    Tincani, A.5
  • 23
    • 77955042053 scopus 로고    scopus 로고
    • Analytical and clinical performance of a new, automated assay panel for the diagnosis of antiphospholipid syndrome
    • De Moerloose P, Reber G, Musial J, Arnout J. Analytical and clinical performance of a new, automated assay panel for the diagnosis of antiphospholipid syndrome. J Thromb Haemost 2010;8:1540-6.
    • (2010) J Thromb Haemost , vol.8 , pp. 1540-1546
    • De Moerloose, P.1    Reber, G.2    Musial, J.3    Arnout, J.4
  • 24
    • 82355161140 scopus 로고    scopus 로고
    • Evaluation of a new set of automated chemiluminescense assays for anticardiolipin and anti-beta2-glycoprotein i antibodies in the laboratory diagnosis of the antiphospholipid syndrome
    • Persijn L, Decavele AS, Schouwers S, Devreese K. Evaluation of a new set of automated chemiluminescense assays for anticardiolipin and anti-beta2-glycoprotein I antibodies in the laboratory diagnosis of the antiphospholipid syndrome. Thromb Res 2011;128:565-9.
    • (2011) Thromb Res , vol.128 , pp. 565-569
    • Persijn, L.1    Decavele, A.S.2    Schouwers, S.3    Devreese, K.4
  • 25
    • 84873291012 scopus 로고    scopus 로고
    • Performance of two new, automated chemiluminescence assay panels for anticardiolipin and anti-beta2-glycoprotein i antibodies in the laboratory diagnosis of the antiphospholipid syndrome
    • Van Hoecke F, Persijn L, Decavele AS, Devreese K. Performance of two new, automated chemiluminescence assay panels for anticardiolipin and anti-beta2-glycoprotein I antibodies in the laboratory diagnosis of the antiphospholipid syndrome. Int J Lab Hematol 2012;34:630-40.
    • (2012) Int J Lab Hematol , vol.34 , pp. 630-640
    • Van Hoecke, F.1    Persijn, L.2    Decavele, A.S.3    Devreese, K.4
  • 27
    • 84888405844 scopus 로고    scopus 로고
    • Evaluation of different immunoassays for the detection of antiphospholipid antibodies: Report of a wet workshop during the 13th International Congress on Antiphospholipid Antibodies
    • Forastiero R, Papalardo E, Watkins M, Nguyen H, Quirbach C, Jaskal K, et al. Evaluation of different immunoassays for the detection of antiphospholipid antibodies: report of a wet workshop during the 13th International Congress on Antiphospholipid Antibodies. Clin Chim Acta 2014;428:99-105.
    • (2014) Clin Chim Acta , vol.428 , pp. 99-105
    • Forastiero, R.1    Papalardo, E.2    Watkins, M.3    Nguyen, H.4    Quirbach, C.5    Jaskal, K.6
  • 29
    • 84893642816 scopus 로고    scopus 로고
    • Clinical performance of anticardiolipin and anti2 glycoprotein i antibodies using a new automated chemiluminescent assay: Superior thrombotic prediction of combined results measured by two different methods
    • Chung Y, Kim JE, Lim HS, Kim HK. Clinical performance of anticardiolipin and anti2 glycoprotein I antibodies using a new automated chemiluminescent assay: superior thrombotic prediction of combined results measured by two different methods. Blood Coagul Fibrinolysis 2014;25:10-5.
    • (2014) Blood Coagul Fibrinolysis , vol.25 , pp. 10-15
    • Chung, Y.1    Kim, J.E.2    Lim, H.S.3    Kim, H.K.4
  • 30
    • 0033498113 scopus 로고    scopus 로고
    • A chimeric antibody with the human gamma1 constant region as a putative standard for assays to detect IgG beta2-glycoprotein I-dependent anticardiolipin and anti-beta2-glycoprotein i antibodies
    • Ichikawa K, Tsutsumi A, Atsumi T, Matsuura E, Kobayashi S, Hughes GR, et al. A chimeric antibody with the human gamma1 constant region as a putative standard for assays to detect IgG beta2-glycoprotein I-dependent anticardiolipin and anti-beta2-glycoprotein I antibodies. Arthritis Rheum 1999;42:2461-70.
    • (1999) Arthritis Rheum , vol.42 , pp. 2461-2470
    • Ichikawa, K.1    Tsutsumi, A.2    Atsumi, T.3    Matsuura, E.4    Kobayashi, S.5    Hughes, G.R.6
  • 31
    • 52449102771 scopus 로고    scopus 로고
    • Influence of different IgG anticardiolipin antibody cut-off values on antiphospholipid syndrome classification
    • Ruffatti A, Olivieri S, Tonello M, Bortolati M, Bison E, Salvan E, et al. Influence of different IgG anticardiolipin antibody cut-off values on antiphospholipid syndrome classification. J Thromb Haemost 2008;6:1693-6.
    • (2008) J Thromb Haemost , vol.6 , pp. 1693-1696
    • Ruffatti, A.1    Olivieri, S.2    Tonello, M.3    Bortolati, M.4    Bison, E.5    Salvan, E.6
  • 32
    • 18544372466 scopus 로고    scopus 로고
    • Understanding interobserver agreement: The kappa statistic
    • Viera AJ, Garrett JM. Understanding interobserver agreement: the kappa statistic. Fam Med 2005;37:360-3.
    • (2005) Fam Med , vol.37 , pp. 360-363
    • Viera, A.J.1    Garrett, J.M.2
  • 33
    • 84916619949 scopus 로고    scopus 로고
    • Refinement of the cutoff values of the HemosIL AcuStar assay for the detection of anticardiolipin and anti-beta2-glycoprotein-1 antibodies
    • Fontana P, Poncet A, Lindhoff-Last E, de Moerloose P, Devreese KM. Refinement of the cutoff values of the HemosIL AcuStar assay for the detection of anticardiolipin and anti-beta2-glycoprotein-1 antibodies. J Thromb Haemost 2014;12:2034-7.
    • (2014) J Thromb Haemost , vol.12 , pp. 2034-2037
    • Fontana, P.1    Poncet, A.2    Lindhoff-Last, E.3    De Moerloose, P.4    Devreese, K.M.5
  • 34
    • 0037370733 scopus 로고    scopus 로고
    • Lupus anticoagulants are stronger risk factors for thrombosis than anticardiolipin antibodies in the antiphospholipid syndrome: A systematic review of the literature
    • Galli M, Luciani D, Bertolini G, Barbui T. Lupus anticoagulants are stronger risk factors for thrombosis than anticardiolipin antibodies in the antiphospholipid syndrome: a systematic review of the literature. Blood 2003;101:1827-32.
    • (2003) Blood , vol.101 , pp. 1827-1832
    • Galli, M.1    Luciani, D.2    Bertolini, G.3    Barbui, T.4
  • 35
    • 38349132254 scopus 로고    scopus 로고
    • Invitation to a debate on the serological criteria that define the antiphospholipid syndrome
    • Galli M, Reber G, De Moerloose P, De Groot PG. Invitation to a debate on the serological criteria that define the antiphospholipid syndrome. J Thromb Haemost 2008;6:399-401.
    • (2008) J Thromb Haemost , vol.6 , pp. 399-401
    • Galli, M.1    Reber, G.2    De Moerloose, P.3    De Groot, P.G.4
  • 36
    • 0141958839 scopus 로고    scopus 로고
    • Anti-beta 2-glycoprotein I, antiprothrombin antibodies, and the risk of thrombosis in the antiphospholipid syndrome
    • Galli M, Luciani D, Bertolini G, Barbui T. Anti-beta 2-glycoprotein I, antiprothrombin antibodies, and the risk of thrombosis in the antiphospholipid syndrome. Blood 2003;102:2717-23.
    • (2003) Blood , vol.102 , pp. 2717-2723
    • Galli, M.1    Luciani, D.2    Bertolini, G.3    Barbui, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.