메뉴 건너뛰기




Volumn 25, Issue 4, 2015, Pages 415-427

Inverse identification of the release location, temporal rates, and sensor alarming time of an airborne pollutant source

Author keywords

Bayesian probability; Inverse matrix; Inverse modeling; Release rate quantification; Sensor alarm time; Source identification

Indexed keywords

CABINS (AIRCRAFT); LOCATION; MATRIX ALGEBRA; STEADY FLOW;

EID: 84930677449     PISSN: 09056947     EISSN: 16000668     Source Type: Journal    
DOI: 10.1111/ina.12153     Document Type: Article
Times cited : (46)

References (25)
  • 1
    • 68349150526 scopus 로고    scopus 로고
    • Identification of pollution sources in urban areas using reverse simulation with reversed time marching method
    • Bady, M., Kato, S. and Huang, H. (2009) Identification of pollution sources in urban areas using reverse simulation with reversed time marching method, J. Asian Archit. Build. Eng., 8, 275-282.
    • (2009) J. Asian Archit. Build. Eng. , vol.8 , pp. 275-282
    • Bady, M.1    Kato, S.2    Huang, H.3
  • 2
    • 84255194366 scopus 로고    scopus 로고
    • Contaminant source identification within a building: toward design of immume buildings
    • Bastani, A., Haghighat, F. and Kozinski, J.A. (2012) Contaminant source identification within a building: toward design of immume buildings, Build. Environ., 51, 320-329.
    • (2012) Build. Environ. , vol.51 , pp. 320-329
    • Bastani, A.1    Haghighat, F.2    Kozinski, J.A.3
  • 3
    • 67650890638 scopus 로고    scopus 로고
    • Evaluation of measurement data - Guide to the expression of uncertainty in measurement
    • JCGM 100:2008 (GUM 1995 with minor corrections), BIPM, Sèvres, France.
    • BIPM. (2008) Evaluation of measurement data - Guide to the expression of uncertainty in measurement, JCGM 100:2008 (GUM 1995 with minor corrections), BIPM, Sèvres, France.
    • (2008)
  • 4
    • 84890474527 scopus 로고    scopus 로고
    • Fast identification of multiple indoor constant contaminant sources by ideal sensors: a theoretical model and numerical validation
    • Cai, H., Li, X., Chen, Z. and Kong, L. (2013) Fast identification of multiple indoor constant contaminant sources by ideal sensors: a theoretical model and numerical validation, Indoor Built Environ., 22, 897-909.
    • (2013) Indoor Built Environ. , vol.22 , pp. 897-909
    • Cai, H.1    Li, X.2    Chen, Z.3    Kong, L.4
  • 5
    • 0000570697 scopus 로고
    • Analysis of discrete ill-posed problems by means of the L-curve
    • Hansen, P.C. (1992) Analysis of discrete ill-posed problems by means of the L-curve, SIAM Rev., 34, 561-580.
    • (1992) SIAM Rev. , vol.34 , pp. 561-580
    • Hansen, P.C.1
  • 7
    • 0001632418 scopus 로고
    • The use of the L-curve in the regularization of discrete ill-posed problems
    • Hansen, P.C. and O'Leary, D.P. (1993) The use of the L-curve in the regularization of discrete ill-posed problems, SIAM J. Sci. Comput., 14, 1487-1503.
    • (1993) SIAM J. Sci. Comput. , vol.14 , pp. 1487-1503
    • Hansen, P.C.1    O'Leary, D.P.2
  • 8
    • 80054802324 scopus 로고    scopus 로고
    • Thermal simulation: response factor analysis using three-dimensional CFD in the simulation of air conditioing control
    • Hiyama, K., Kato, S. and Ishida, Y. (2010) Thermal simulation: response factor analysis using three-dimensional CFD in the simulation of air conditioing control. Build. Simul., 3, 195-203.
    • (2010) Build. Simul. , vol.3 , pp. 195-203
    • Hiyama, K.1    Kato, S.2    Ishida, Y.3
  • 9
    • 79959769241 scopus 로고    scopus 로고
    • Coupling 3D transient pollutant transport in a room into a flow network model with concentration response factor method
    • Hiyama, K., Ishida, Y. and Kato, S. (2008) Coupling 3D transient pollutant transport in a room into a flow network model with concentration response factor method, ASHRAE Trans., 114, 119-129.
    • (2008) ASHRAE Trans. , vol.114 , pp. 119-129
    • Hiyama, K.1    Ishida, Y.2    Kato, S.3
  • 10
    • 55849089967 scopus 로고    scopus 로고
    • Method for coupling three-dimensional transient pollutant transport into one-dimensional transport simulation based on concentration response factor
    • Ishida, Y. and Kato, S. (2008) Method for coupling three-dimensional transient pollutant transport into one-dimensional transport simulation based on concentration response factor, ASHRAE Trans., 114, 259-272.
    • (2008) ASHRAE Trans. , vol.114 , pp. 259-272
    • Ishida, Y.1    Kato, S.2
  • 11
    • 33845382594 scopus 로고    scopus 로고
    • Bayesian inference for source determination with applications to a complex urban environment
    • Keats, A., Yee, E. and Lien, F.S. (2007) Bayesian inference for source determination with applications to a complex urban environment, Atmos. Environ., 41, 465-479.
    • (2007) Atmos. Environ. , vol.41 , pp. 465-479
    • Keats, A.1    Yee, E.2    Lien, F.S.3
  • 12
    • 36749076954 scopus 로고    scopus 로고
    • Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals
    • Liu, X. and Zhai, Z. (2007) Inverse modeling methods for indoor airborne pollutant tracking: literature review and fundamentals, Indoor Air, 17, 419-438.
    • (2007) Indoor Air , vol.17 , pp. 419-438
    • Liu, X.1    Zhai, Z.2
  • 13
    • 38349010496 scopus 로고    scopus 로고
    • Location identification for indoor instantaneous point contaminant source by probability-based inverse computational fluid dynamics modelling
    • Liu, X. and Zhai, Z. (2008) Location identification for indoor instantaneous point contaminant source by probability-based inverse computational fluid dynamics modelling, Indoor Air, 18, 2-11.
    • (2008) Indoor Air , vol.18 , pp. 2-11
    • Liu, X.1    Zhai, Z.2
  • 14
    • 84886245492 scopus 로고    scopus 로고
    • Implementing state-space methods for multizone contaminant transport
    • Parker, S.T., Lorenzetti, D.M. and Sohn, M.D. (2014) Implementing state-space methods for multizone contaminant transport, Build. Environ., 71, 131-139.
    • (2014) Build. Environ. , vol.71 , pp. 131-139
    • Parker, S.T.1    Lorenzetti, D.M.2    Sohn, M.D.3
  • 15
    • 0036924559 scopus 로고    scopus 로고
    • Rapidly locating and characterizing pollutant releases in buildings
    • Sohn, M.D., Reynolds, P., Singh, N. and Gadgil, A.J. (2002) Rapidly locating and characterizing pollutant releases in buildings, J. Air Waste Manage., 52, 1422-1432.
    • (2002) J. Air Waste Manage. , vol.52 , pp. 1422-1432
    • Sohn, M.D.1    Reynolds, P.2    Singh, N.3    Gadgil, A.J.4
  • 16
    • 33646862815 scopus 로고    scopus 로고
    • Systems approach to evaluating sensor characteristics for real-time monitoring of high-risk indoor contaminant releases
    • Sreedharan, P., Sohn, M.D., Gadgil, A.J. and Nazaroff, W.W. (2006) Systems approach to evaluating sensor characteristics for real-time monitoring of high-risk indoor contaminant releases, Atmos. Environ., 40, 3490-3502.
    • (2006) Atmos. Environ. , vol.40 , pp. 3490-3502
    • Sreedharan, P.1    Sohn, M.D.2    Gadgil, A.J.3    Nazaroff, W.W.4
  • 17
    • 36348991317 scopus 로고    scopus 로고
    • Influence of indoor transport and mixing time scales on the performance of sensor systems for characterizing contaminant releases
    • Sreedharan, P., Sohn, M.D., Nazaroff, W.W. and Gadgil, A.J. (2007) Influence of indoor transport and mixing time scales on the performance of sensor systems for characterizing contaminant releases, Atmos. Environ., 41, 9530-9542.
    • (2007) Atmos. Environ. , vol.41 , pp. 9530-9542
    • Sreedharan, P.1    Sohn, M.D.2    Nazaroff, W.W.3    Gadgil, A.J.4
  • 19
    • 77957896243 scopus 로고    scopus 로고
    • Real-time identification of indoor pollutant source positions based on neural network locator of contaminant sources and optimized sensor networks
    • Vukovic, V., Tabares-Velasco, P.S. and Srebric, J. (2010) Real-time identification of indoor pollutant source positions based on neural network locator of contaminant sources and optimized sensor networks, J. Air Waste Manage., 60, 1034-1048.
    • (2010) J. Air Waste Manage. , vol.60 , pp. 1034-1048
    • Vukovic, V.1    Tabares-Velasco, P.S.2    Srebric, J.3
  • 20
    • 84881596986 scopus 로고    scopus 로고
    • A method to identify the point source of indoor gaseous contaminant based on limited on-site steady concentration measurement
    • Wang, X., Tao, W., Lu, Y. and Wang, F. (2013) A method to identify the point source of indoor gaseous contaminant based on limited on-site steady concentration measurement, Build. Simul., 6, 395-402.
    • (2013) Build. Simul. , vol.6 , pp. 395-402
    • Wang, X.1    Tao, W.2    Lu, Y.3    Wang, F.4
  • 21
    • 84864744051 scopus 로고    scopus 로고
    • Experimental verification of tracking algorithm for dynamically-releasing single indoor contaminant
    • Zhai, Z., Liu, X., Wang, H., Li, Y. and Liu, J. (2012) Experimental verification of tracking algorithm for dynamically-releasing single indoor contaminant, Build. Simul., 5, 5-14.
    • (2012) Build. Simul. , vol.5 , pp. 5-14
    • Zhai, Z.1    Liu, X.2    Wang, H.3    Li, Y.4    Liu, J.5
  • 22
    • 34249709479 scopus 로고    scopus 로고
    • Identification of contaminant sources in enclosed environments by inverse CFD modelling
    • Zhang, T. and Chen, Q. (2007a) Identification of contaminant sources in enclosed environments by inverse CFD modelling, Indoor Air, 17, 167-177.
    • (2007) Indoor Air , vol.17 , pp. 167-177
    • Zhang, T.1    Chen, Q.2
  • 23
    • 36749008448 scopus 로고    scopus 로고
    • Identification of contaminant sources in enclosed spaces by a single sensor
    • Zhang, T. and Chen, Q. (2007b) Identification of contaminant sources in enclosed spaces by a single sensor, Indoor Air, 17, 439-449.
    • (2007) Indoor Air , vol.17 , pp. 439-449
    • Zhang, T.1    Chen, Q.2
  • 24
    • 84859886115 scopus 로고    scopus 로고
    • Inversely tracking indoor airborne particles to locate their release sources
    • Zhang, T., Li, H. and Wang, S. (2012) Inversely tracking indoor airborne particles to locate their release sources, Atmos. Environ., 55, 328-338.
    • (2012) Atmos. Environ. , vol.55 , pp. 328-338
    • Zhang, T.1    Li, H.2    Wang, S.3
  • 25
    • 84878358266 scopus 로고    scopus 로고
    • An inverse model based on CFD to quantify the temporal release rate of a continuously released pollutant source
    • Zhang, T., Yin, S. and Wang, S. (2013) An inverse model based on CFD to quantify the temporal release rate of a continuously released pollutant source, Atmos. Environ., 77, 62-77.
    • (2013) Atmos. Environ. , vol.77 , pp. 62-77
    • Zhang, T.1    Yin, S.2    Wang, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.