메뉴 건너뛰기




Volumn 114 PART 1, Issue , 2008, Pages 259-272

Method for coupling three-dimensional transient pollutant transport into one-dimensional transport simulation based on concentration response factor

Author keywords

[No Author keywords available]

Indexed keywords

ADVECTION; FLOW FIELDS; HEATING; ONE DIMENSIONAL; REFRIGERATION; STEADY FLOW; CONTAMINATION; LINEAR EQUATIONS; THREE DIMENSIONAL;

EID: 55849089967     PISSN: 00012505     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (17)

References (15)
  • 1
    • 0032647807 scopus 로고    scopus 로고
    • COMIS - An international multizone airflow and contaminant transport model
    • Feustel, H. E. 1999. COMIS - An international multizone airflow and contaminant transport model. Energy and Buildings, 30, 3-18.
    • (1999) Energy and Buildings , vol.30 , pp. 3-18
    • Feustel, H.E.1
  • 2
    • 0037333676 scopus 로고    scopus 로고
    • Simulating air flow and temperature distribution inside buildings using a modified version of COMIS with sub-zonal divisions
    • Ren, Z. and Stewart, J. 2003. Simulating air flow and temperature distribution inside buildings using a modified version of COMIS with sub-zonal divisions. Energy and Buildings, 35, 257-271.
    • (2003) Energy and Buildings , vol.35 , pp. 257-271
    • Ren, Z.1    Stewart, J.2
  • 3
    • 0027874254 scopus 로고
    • Improvement of multizone model predictions by detailed flow path values from CFD calculation
    • Schaelin A., Dorer, V., Van der Mass, J. and Moser, A. 1993. Improvement of multizone model predictions by detailed flow path values from CFD calculation. ASHRAE Transactions, 93-7-4, 709-720.
    • (1993) ASHRAE Transactions, 93-7-4 , pp. 709-720
    • Schaelin, A.1    Dorer, V.2    Van der Mass, J.3    Moser, A.4
  • 4
    • 34548709040 scopus 로고    scopus 로고
    • Theoretical and numerical studies of coupling multizone and CFD models for building air distribution simulations
    • in press
    • Wang, L. and Chen. Q. 2007. Theoretical and numerical studies of coupling multizone and CFD models for building air distribution simulations. Indoor Air (in press).
    • (2007) Indoor Air
    • Wang, L.1    Chen, Q.2
  • 5
    • 0004220252 scopus 로고
    • Asakura Shoten, in Japanese
    • Hino, M. 1977. Spectral analysis. Asakura Shoten. (in Japanese)
    • (1977) Spectral analysis
    • Hino, M.1
  • 6
    • 55849153705 scopus 로고    scopus 로고
    • Committee of air-conditioning system standards of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan (SHASE). 1972. The calculation method of dynamic air-conditioning load by a computer. SHASE. (in Japanese).
    • Committee of air-conditioning system standards of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan (SHASE). 1972. The calculation method of dynamic air-conditioning load by a computer. SHASE. (in Japanese).
  • 7
    • 55849092320 scopus 로고
    • The Japan Society of Refrigeration and Air Conditioning Engineers JSRAE, in Japanese
    • Matsuo, Yoh. 1970. Calculation method of heat gain of solar radiation. The Japan Society of Refrigeration and Air Conditioning Engineers (JSRAE). (in Japanese).
    • (1970) Calculation method of heat gain of solar radiation
    • Matsuo, Y.1
  • 8
    • 0002662812 scopus 로고
    • Cooling Load Calculation by Thermal Response Factor Method
    • Stephenson, D. G. and Mitalas, G. P. 1967. Cooling Load Calculation by Thermal Response Factor Method. ASHRAE Transactions, Vol. 73, Part I.
    • (1967) ASHRAE Transactions , vol.73 , Issue.PART I
    • Stephenson, D.G.1    Mitalas, G.P.2
  • 12
    • 55849122807 scopus 로고    scopus 로고
    • Kato, S., Ito, K. and Murakami, S. 2000. Study of Normalized Concentration in an Occupied Zone, Visitation Frequency and Purging Flow Rate under Various Ventilation System, Part 1 Study on evaluation of Ventilation Effectiveness of Occupied Zone in Office Space. SHASE. (in Japanese).
    • Kato, S., Ito, K. and Murakami, S. 2000. Study of Normalized Concentration in an Occupied Zone, Visitation Frequency and Purging Flow Rate under Various Ventilation System, Part 1 Study on evaluation of Ventilation Effectiveness of Occupied Zone in Office Space. SHASE. (in Japanese).
  • 13
    • 55849109032 scopus 로고    scopus 로고
    • Ito, K. and Kato, S. 2005. Study of Normalized Concentration, Visitation Frequency and Purging Flow Rate under the Condition to Set up Furniture in Occupied Zone, Part 2 Study on evaluation of Ventilation Effectiveness of Occupied Zone in Office Space. SHASE. (in Japanese).
    • Ito, K. and Kato, S. 2005. Study of Normalized Concentration, Visitation Frequency and Purging Flow Rate under the Condition to Set up Furniture in Occupied Zone, Part 2 Study on evaluation of Ventilation Effectiveness of Occupied Zone in Office Space. SHASE. (in Japanese).
  • 15
    • 2442433925 scopus 로고
    • Towards the ultimate conservative difference scheme, V: A second-order sequel to Godunov's method
    • Van Leer, B. 1979. Towards the ultimate conservative difference scheme, V: a second-order sequel to Godunov's method. Journal of Computational Physics ;32;101-36.
    • (1979) Journal of Computational Physics , vol.32 , pp. 101-136
    • Van Leer, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.