메뉴 건너뛰기




Volumn 99, Issue 6, 2015, Pages 794-800

Quantitative comparison of macular segmentation performance using identical retinal regions across multiple spectral-domain optical coherence tomography instruments

Author keywords

[No Author keywords available]

Indexed keywords

A SCAN; ADULT; ALGORITHM; ARTICLE; B SCAN; CENTRAL MACULAR THICKNESS; CENTRE POINT THICKNESS; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; ERROR; FEMALE; HUMAN; HUMAN TISSUE; INCIDENCE; MALE; MEASUREMENT ACCURACY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUANTITATIVE STUDY; SEGMENTATION ERROR; SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY; VISUAL SYSTEM PARAMETERS; ARTIFACT; DEVICES; DIABETIC RETINOPATHY; DIAGNOSTIC ERROR; EPIRETINAL MEMBRANE; MACULAR DEGENERATION; MACULAR EDEMA; MIDDLE AGED; OPTICAL COHERENCE TOMOGRAPHY; PATHOLOGY; REPRODUCIBILITY; RETINA; RETINAL DISEASES; RETINAL VEIN OCCLUSION; THREE DIMENSIONAL IMAGING; WET MACULAR DEGENERATION;

EID: 84930383602     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjophthalmol-2014-305573     Document Type: Article
Times cited : (32)

References (25)
  • 1
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D, Swanson EA, Lin CP, et al. Optical coherence tomography. Science 1991;254:1178-81.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 3
    • 0036629502 scopus 로고    scopus 로고
    • In vivo human retinal imaging by Fourier domain optical coherence tomography
    • Wojtkowski M, Leitgeb R, Kowalczyk A, et al. In vivo human retinal imaging by Fourier domain optical coherence tomography. J Biomed Opt 2002;7:457-63.
    • (2002) J Biomed Opt , vol.7 , pp. 457-463
    • Wojtkowski, M.1    Leitgeb, R.2    Kowalczyk, A.3
  • 4
    • 79251481152 scopus 로고    scopus 로고
    • Retinal optical coherence tomography: Past, present and future perspectives
    • Geitzenauer W, Hitzenberger CK, Schmidt-Erfurth UM. Retinal optical coherence tomography: past, present and future perspectives. Br J Ophthalmol 2011;95:171-7.
    • (2011) Br J Ophthalmol , vol.95 , pp. 171-177
    • Geitzenauer, W.1    Hitzenberger, C.K.2    Schmidt-Erfurth, U.M.3
  • 5
    • 0028875360 scopus 로고
    • Quantitative assessment of macular edema with optical coherence tomography
    • Hee MR, Puliafito CA, Wong C, et al. Quantitative assessment of macular edema with optical coherence tomography. Arch Ophthalmol 1995;113:1019-29.
    • (1995) Arch Ophthalmol , vol.113 , pp. 1019-1029
    • Hee, M.R.1    Puliafito, C.A.2    Wong, C.3
  • 6
    • 0029787327 scopus 로고    scopus 로고
    • Optical coherence tomography of age-related macular degeneration and choroidal neovascularization
    • Hee MR, Baumal CR, Puliafito CA, et al. Optical coherence tomography of age-related macular degeneration and choroidal neovascularization. Ophthalmology 1996;103:1260-70.
    • (1996) Ophthalmology , vol.103 , pp. 1260-1270
    • Hee, M.R.1    Baumal, C.R.2    Puliafito, C.A.3
  • 7
    • 33947403618 scopus 로고    scopus 로고
    • An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (Lucentis) for neovascular age-related macular degeneration
    • Fung AE, Lalwani GA, Rosenfeld PJ, et al. An optical coherence tomography-guided, variable dosing regimen with intravitreal ranibizumab (Lucentis) for neovascular age-related macular degeneration. Am J Ophthalmol 2007;143:566-83.
    • (2007) Am J Ophthalmol , vol.143 , pp. 566-583
    • Fung, A.E.1    Lalwani, G.A.2    Rosenfeld, P.J.3
  • 8
    • 77952889477 scopus 로고    scopus 로고
    • Ranibizumab for macular edema following central retinal vein occlusion: Six-month primary end point results of a phase III study
    • e1
    • Brown DM, Campochiaro PA, Singh RP, et al. Ranibizumab for macular edema following central retinal vein occlusion: six-month primary end point results of a phase III study. Ophthalmology 2010;117:1124-33.e1.
    • (2010) Ophthalmology , vol.117 , pp. 1124-1133
    • Brown, D.M.1    Campochiaro, P.A.2    Singh, R.P.3
  • 9
    • 77952891051 scopus 로고    scopus 로고
    • Ranibizumab for macular edema following branch retinal vein occlusion: Six-month primary end point results of a phase III study
    • e1
    • Campochiaro PA, Heier JS, Feiner L, et al. Ranibizumab for macular edema following branch retinal vein occlusion: six-month primary end point results of a phase III study. Ophthalmology 2010;117:1102-12.e1.
    • (2010) Ophthalmology , vol.117 , pp. 1102-1112
    • Campochiaro, P.A.1    Heier, J.S.2    Feiner, L.3
  • 10
    • 79953311138 scopus 로고    scopus 로고
    • The RESTORE study: Ranibizumab monotherapy or combined with laser versus laser monotherapy for diabetic macular edema
    • Mitchell P, Bandello F, Schmidt-Erfurth U, et al. The RESTORE study: ranibizumab monotherapy or combined with laser versus laser monotherapy for diabetic macular edema. Ophthalmology 2011;118:615-25.
    • (2011) Ophthalmology , vol.118 , pp. 615-625
    • Mitchell, P.1    Bandello, F.2    Schmidt-Erfurth, U.3
  • 11
    • 31644448419 scopus 로고    scopus 로고
    • Errors in retinal thickness measurements obtained by optical coherence tomography
    • Sadda SR, Wu Z, Walsh AC, et al. Errors in retinal thickness measurements obtained by optical coherence tomography. Ophthalmology 2006;113:285-93.
    • (2006) Ophthalmology , vol.113 , pp. 285-293
    • Sadda, S.R.1    Wu, Z.2    Walsh, A.C.3
  • 12
    • 47049106131 scopus 로고    scopus 로고
    • Optical coherence tomography: Limits of the retinal-mapping program in age-related macular degeneration
    • Krebs I, Haas P, Zeiler F, et al. Optical coherence tomography: limits of the retinal-mapping program in age-related macular degeneration. Br J Ophthalmol 2008;92:933-5.
    • (2008) Br J Ophthalmol , vol.92 , pp. 933-935
    • Krebs, I.1    Haas, P.2    Zeiler, F.3
  • 13
    • 70349440977 scopus 로고    scopus 로고
    • Assessment of artifacts and reproducibility across spectral- and time-domain optical coherence tomography devices
    • Ho J, Sull AC, Vuong LN, et al. Assessment of artifacts and reproducibility across spectral- and time-domain optical coherence tomography devices. Ophthalmology 2009;116:1960-70.
    • (2009) Ophthalmology , vol.116 , pp. 1960-1970
    • Ho, J.1    Sull, A.C.2    Vuong, L.N.3
  • 14
    • 70350440496 scopus 로고    scopus 로고
    • Comparison of retinal thickness measurements and segmentation performance of four different spectral and time domain OCT devices in neovascular age-related macular degeneration
    • Mylonas G, Ahlers C, Malamos P, et al. Comparison of retinal thickness measurements and segmentation performance of four different spectral and time domain OCT devices in neovascular age-related macular degeneration. Br J Ophthalmol 2009;93:1453-60.
    • (2009) Br J Ophthalmol , vol.93 , pp. 1453-1460
    • Mylonas, G.1    Ahlers, C.2    Malamos, P.3
  • 15
    • 58249089761 scopus 로고    scopus 로고
    • Segmentation error in stratus optical coherence tomography for neovascular age-related macular degeneration
    • Patel PJ, Chen FK, da Cruz L, et al. Segmentation error in stratus optical coherence tomography for neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 2009;50:399-404.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 399-404
    • Patel, P.J.1    Chen, F.K.2    Da Cruz, L.3
  • 16
    • 70350436480 scopus 로고    scopus 로고
    • Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography
    • Keane PA, Mand PS, Liakopoulos S, et al. Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography. Br J Ophthalmol 2009;93:1461-7.
    • (2009) Br J Ophthalmol , vol.93 , pp. 1461-1467
    • Keane, P.A.1    Mand, P.S.2    Liakopoulos, S.3
  • 17
    • 62649101218 scopus 로고    scopus 로고
    • Quality of the threshold algorithm in age-related macular degeneration: Stratus versus cirrus OCT
    • Krebs I, Falkner-Radler C, Hagen S, et al. Quality of the threshold algorithm in age-related macular degeneration: stratus versus cirrus OCT. Invest Ophthalmol Vis Sci 2009;50:995-1000.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 995-1000
    • Krebs, I.1    Falkner-Radler, C.2    Hagen, S.3
  • 18
    • 77952892012 scopus 로고    scopus 로고
    • Evaluation of artifacts associated with macular spectral-domain optical coherence tomography
    • e4
    • Han IC, Jaffe GJ. Evaluation of artifacts associated with macular spectral-domain optical coherence tomography. Ophthalmology 2010;117:1177-89.e4.
    • (2010) Ophthalmology , vol.117 , pp. 1177-1189
    • Han, I.C.1    Jaffe, G.J.2
  • 19
    • 77951188345 scopus 로고    scopus 로고
    • Artifacts in automatic retinal segmentation using different optical coherence tomography instruments
    • Giani A, Cigada M, Esmaili DD, et al. Artifacts in automatic retinal segmentation using different optical coherence tomography instruments. Retina 2010;30:607-16.
    • (2010) Retina , vol.30 , pp. 607-616
    • Giani, A.1    Cigada, M.2    Esmaili, D.D.3
  • 20
    • 77952634064 scopus 로고    scopus 로고
    • Comparison of macular thickness measurement and segmentation error rate between stratus and fourier-domain optical coherence tomography
    • Modjtahedi S, Chiou C, Modjtahedi B, et al. Comparison of Macular Thickness Measurement and Segmentation Error Rate Between Stratus and Fourier-Domain Optical Coherence Tomography. Ophthalmic Surg Lasers Imaging 2010;41:301.
    • (2010) Ophthalmic Surg Lasers Imaging , vol.41 , pp. 301
    • Modjtahedi, S.1    Chiou, C.2    Modjtahedi, B.3
  • 21
    • 79952317745 scopus 로고    scopus 로고
    • Evaluation of segmentation procedures using spectral domain optical coherence tomography in exudative age-related macular degeneration
    • Malamos P, Ahlers C, Mylonas G, et al. Evaluation of segmentation procedures using spectral domain optical coherence tomography in exudative age-related macular degeneration. Retina 2011;31:453-63.
    • (2011) Retina , vol.31 , pp. 453-463
    • Malamos, P.1    Ahlers, C.2    Mylonas, G.3
  • 22
    • 80054866174 scopus 로고    scopus 로고
    • Quality and reproducibility of retinal thickness measurements in two spectral domain optical coherence tomography machines
    • Krebs I, Smretschnig E, Moussa S, et al. Quality and reproducibility of retinal thickness measurements in two spectral domain optical coherence tomography machines. Invest Ophthalmol Vis Sci 2011;52:6925-33.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 6925-6933
    • Krebs, I.1    Smretschnig, E.2    Moussa, S.3
  • 23
    • 79954561803 scopus 로고    scopus 로고
    • Comparison of retinal thickness values and segmentation performance of different OCT devices in acute branch retinal vein occlusion
    • Matt G, Sacu S, Buehl W, et al. Comparison of retinal thickness values and segmentation performance of different OCT devices in acute branch retinal vein occlusion. Eye 2011;25:511-18.
    • (2011) Eye , vol.25 , pp. 511-518
    • Matt, G.1    Sacu, S.2    Buehl, W.3
  • 24
    • 84858082266 scopus 로고    scopus 로고
    • Overcoming segmentation errors in measurements of macular thickness made by spectral-domain optical coherence tomography
    • Song Y, Lee BR, Shin YW, et al. Overcoming Segmentation Errors in Measurements of Macular Thickness Made By Spectral-Domain Optical Coherence Tomography. Retina 2012;32:569-80.
    • (2012) Retina , vol.32 , pp. 569-580
    • Song, Y.1    Lee, B.R.2    Shin, Y.W.3
  • 25
    • 67649998896 scopus 로고    scopus 로고
    • Evaluation of optical coherence tomography retinal thickness parameters for use in clinical trials for neovascular age-related macular degeneration
    • Keane PA, Liakopoulos S, Jivrajka RV, et al. Evaluation of optical coherence tomography retinal thickness parameters for use in clinical trials for neovascular age-related macular degeneration. Invest Ophthalmol Vis Sci 2009;50:3378-85.
    • (2009) Invest Ophthalmol Vis Sci , vol.50 , pp. 3378-3385
    • Keane, P.A.1    Liakopoulos, S.2    Jivrajka, R.V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.