메뉴 건너뛰기




Volumn , Issue , 2014, Pages 638-645

Evaluation of the influence of rotor magnetic anisotropy on condition monitoring of 2 pole induction motors

Author keywords

[No Author keywords available]

Indexed keywords

CONDITION MONITORING; FAULT DETECTION; LAMINATING; MAGNETIC ANISOTROPY; MAGNETISM; SILICON STEEL;

EID: 84930235590     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ECCE.2014.6953455     Document Type: Conference Paper
Times cited : (12)

References (27)
  • 2
    • 0001101689 scopus 로고
    • Anisotropy of magnetic properties in non-oriented electrical steel sheets
    • M. Shiozaki, and Y. Kurosaki, "Anisotropy of magnetic properties in non-oriented electrical steel sheets," Textures and Microstructures, Vol. 11, pp. 159-170, 1989.
    • (1989) Textures and Microstructures , vol.11 , pp. 159-170
    • Shiozaki, M.1    Kurosaki, Y.2
  • 3
    • 84934296091 scopus 로고    scopus 로고
    • Anisotropy of steel sheets and consequence for Epstein test
    • Sept.
    • M. Flavio de Campos, "Anisotropy of steel sheets and consequence for Epstein test," Proc. of IMEKO World Congress, pp. 1-8, Sept. 2006.
    • (2006) Proc. of IMEKO World Congress , pp. 1-8
    • Flavio De Campos, M.1
  • 5
    • 0021487039 scopus 로고
    • Some observations on the magnetic anisotropy of non-oriented 3% si steel sheets
    • Sept.
    • J.H.R. Page, "Some observations on the magnetic anisotropy of non-oriented 3% Si steel sheets," IEEE Trans. on Magn., Vol. MAG-20, no. 5, pp. 1542-1544, Sept. 1984.
    • (1984) IEEE Trans. on Magn. , vol.MAG-20 , Issue.5 , pp. 1542-1544
    • Page, J.H.R.1
  • 6
    • 51249173468 scopus 로고
    • Effects of magnetic properties of nonoriented electrical steel sheets on motor efficiency
    • A. Honda, B. Fukuda, I. Ohyama, and Y. Mine, "Effects of magnetic properties of nonoriented electrical steel sheets on motor efficiency," Journal of Materials Engineering, Vol. 12, no. 1, pp. 41-45, 1990.
    • (1990) Journal of Materials Engineering , vol.12 , Issue.1 , pp. 41-45
    • Honda, A.1    Fukuda, B.2    Ohyama, I.3    Mine, Y.4
  • 7
    • 84961640905 scopus 로고    scopus 로고
    • Extraction and elimination of induction machines inherent asymmetry caused by lamination material anisotropy
    • Nov.
    • T.M. Wolbank, J.L. Machl, P. Macheiner, and H. Hauser, "Extraction and elimination of induction machines inherent asymmetry caused by lamination material anisotropy," Proc. of Power Electronics and Drive Systems, Vol. 1, pp. 508-513, Nov. 2003.
    • (2003) Proc. of Power Electronics and Drive Systems , vol.1 , pp. 508-513
    • Wolbank, T.M.1    Machl, J.L.2    Macheiner, P.3    Hauser, H.4
  • 9
    • 0024121951 scopus 로고
    • Noninvasive detection of broken rotor bars in operating induction motors
    • Dec.
    • G.B. Kliman, R.A. Koegl, J. Stein, R.D. Endicott, M.W. Madden, "Noninvasive detection of broken rotor bars in operating induction motors," IEEE Trans. on Ener. Conv., Vol. 3, no. 4, pp. 873-879, Dec. 1988.
    • (1988) IEEE Trans. on Ener. Conv. , vol.3 , Issue.4 , pp. 873-879
    • Kliman, G.B.1    Koegl, R.A.2    Stein, J.3    Endicott, R.D.4    Madden, M.W.5
  • 10
    • 0002726897 scopus 로고
    • On-line current monitoring - The influence of mechanical loads or a unique rotor design on the diagnosis of broken rotor bars in induction motors
    • W.T. Thomson, "On-line current monitoring - the influence of mechanical loads or a unique rotor design on the diagnosis of broken rotor bars in induction motors," Proc. of ICEM, pp. 1236-1240, 1992.
    • (1992) Proc. of ICEM , pp. 1236-1240
    • Thomson, W.T.1
  • 11
    • 84870883135 scopus 로고
    • Real time expert system for identifying rotor faults and mechanical influences in induction motor phase current
    • Sept.
    • D. Leith, and D. Rankin, "Real time expert system for identifying rotor faults and mechanical influences in induction motor phase current," Proc. of IEE Electric Machines and Drives, Sept. 1991.
    • (1991) Proc. of IEE Electric Machines and Drives
    • Leith, D.1    Rankin, D.2
  • 12
    • 0035396689 scopus 로고    scopus 로고
    • Current signature analysis to detect induction motor faults
    • July/August
    • W.T. Thomson, and M. Fenger, "Current signature analysis to detect induction motor faults," IEEE Ind. Appl. Mag., Vol. 7, no. 4, pp. 26-34 July/August 2001.
    • (2001) IEEE Ind. Appl. Mag. , vol.7 , Issue.4 , pp. 26-34
    • Thomson, W.T.1    Fenger, M.2
  • 13
    • 84884651982 scopus 로고    scopus 로고
    • Evaluation of the influence of rotor axial air duct design on condition monitoring of induction motors
    • Sept./Oct.
    • S. Lee, J. Hong, S.B. Lee, E. Wiedenbrug, M. Teska, and H. Kim, "Evaluation of the Influence of Rotor Axial Air Duct Design on Condition Monitoring of Induction Motors," IEEE Trans. on Ind. Appl., Vol. 49, no. 5, Sept./Oct. 2013.
    • (2013) IEEE Trans. on Ind. Appl. , vol.49 , Issue.5
    • Lee, S.1    Hong, J.2    Lee, S.B.3    Wiedenbrug, E.4    Teska, M.5    Kim, H.6
  • 14
    • 78751676315 scopus 로고    scopus 로고
    • Automated detection of rotor faults for inverter-fed induction machines under standstill conditions
    • Jan./Feb.
    • B. Kim, J. Yang, K. Lee, S.B. Lee, E.J. Wiedenbrug, and M.R. Shah, "Automated detection of rotor faults for inverter-fed induction machines under standstill conditions," IEEE Trans. on Ind. Appl., Vol. 47, no. 1, pp. 55-64, Jan./Feb. 2011.
    • (2011) IEEE Trans. on Ind. Appl. , vol.47 , Issue.1 , pp. 55-64
    • Kim, B.1    Yang, J.2    Lee, K.3    Lee, S.B.4    Wiedenbrug, E.J.5    Shah, M.R.6
  • 16
    • 33746342784 scopus 로고    scopus 로고
    • Validation of a new method for the diagnosis of rotor bar failures via wavelet transform in industrial induction machines
    • July/Aug.
    • J. Antonino-Daviu, M. Riera-Guasp, J.R. Folch, and M.P. Molina-Palomares "Validation of a new method for the diagnosis of rotor bar failures via wavelet transform in industrial induction machines" IEEE Trans. on Ind. Appl., Vol. 42, no. 4, pp. 990-996, July/Aug. 2006.
    • (2006) IEEE Trans. on Ind. Appl. , vol.42 , Issue.4 , pp. 990-996
    • Antonino-Daviu, J.1    Riera-Guasp, M.2    Folch, J.R.3    Molina-Palomares, M.P.4
  • 17
    • 84904647163 scopus 로고    scopus 로고
    • Reliable detection of induction motor rotor faults under the rotor axial air duct influence
    • July/Aug.
    • C. Yang, T. Kang, D. Hyun, S.B. Lee, J. Antonino-Daviu, and J. Pons-Llinares, "Reliable detection of induction motor rotor faults under the rotor axial air duct influence," IEEE Trans. on Ind. Appl., Vol. 50, no. 4, July/Aug. 2014.
    • (2014) IEEE Trans. on Ind. Appl. , vol.50 , Issue.4
    • Yang, C.1    Kang, T.2    Hyun, D.3    Lee, S.B.4    Antonino-Daviu, J.5    Pons-Llinares, J.6
  • 18
    • 84901312509 scopus 로고    scopus 로고
    • Advanced diagnosis of outer cage damage in double-squirrel-cage induction motors under time-varying conditions based on wavelet analysis
    • May/June
    • Y. Gritli, F. Filippetti, L. Zarri, "Advanced diagnosis of outer cage damage in double-squirrel-cage induction motors under time-varying conditions based on wavelet analysis," IEEE Trans. on Ind. Appl., Vol. 50, no. 3, pp. 1791-1800 May/June 2014.
    • (2014) IEEE Trans. on Ind. Appl. , vol.50 , Issue.3 , pp. 1791-1800
    • Gritli, Y.1    Filippetti, F.2    Zarri, L.3
  • 19
    • 3242877165 scopus 로고    scopus 로고
    • On-line diagnosis of inverter-fed induction machines using high-frequency signal injection
    • Jul./Aug.
    • F. Briz, M.W. Degner, A. Diez, and J.M. Guerrero, "On-line diagnosis of inverter-fed induction machines using high-frequency signal injection," IEEE Trans. Ind. Appl., Vol. 40, no. 4, pp. 1153-1161, Jul./Aug. 2004.
    • (2004) IEEE Trans. Ind. Appl. , vol.40 , Issue.4 , pp. 1153-1161
    • Briz, F.1    Degner, M.W.2    Diez, A.3    Guerrero, J.M.4
  • 20
    • 79954457393 scopus 로고    scopus 로고
    • Monitoring of rotor-bar defects in inverter-fed induction machines at zero load and speed
    • May
    • T.M. Wolbank, P. Nussbaumer, C. Hao, and P.E. Macheiner, "Monitoring of rotor-bar defects in inverter-fed induction machines at zero load and speed," IEEE Trans. on Ind. Electron., Vol. 58, no. 5, pp. 1468-1478, May 2011.
    • (2011) IEEE Trans. on Ind. Electron. , vol.58 , Issue.5 , pp. 1468-1478
    • Wolbank, T.M.1    Nussbaumer, P.2    Hao, C.3    Macheiner, P.E.4
  • 21
    • 0021138236 scopus 로고
    • Broken bar in a squirrel-cage rotor of an induction motor, Part 1: Description by superimposed fault-currents (in German)
    • W. Deleroi, "Broken bar in a squirrel-cage rotor of an induction motor, Part 1: description by superimposed fault-currents (in German)," Archiv fur Elektrotechnik 67, pp. 91-99, 1984.
    • (1984) Archiv Fur Elektrotechnik 67 , pp. 91-99
    • Deleroi, W.1
  • 22
    • 84861518172 scopus 로고    scopus 로고
    • Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics
    • June
    • T.J. Sobczyk, and W. Maciolek, "Diagnostics of rotor-cage faults supported by effects due to higher MMF harmonics," Proc. of Power Tech Conf., Vol. 2, pp. 5-9, June 2003.
    • (2003) Proc. of Power Tech Conf. , vol.2 , pp. 5-9
    • Sobczyk, T.J.1    Maciolek, W.2
  • 25
    • 20544439623 scopus 로고    scopus 로고
    • Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults
    • May/June
    • H. Henao, H. Razik, and G.A. Capolino, "Analytical approach of the stator current frequency harmonics computation for detection of induction machine rotor faults," IEEE Trans. on Ind. Appl., Vol. 41, no. 3, pp. 801-807 May/June 2005.
    • (2005) IEEE Trans. on Ind. Appl. , vol.41 , Issue.3 , pp. 801-807
    • Henao, H.1    Razik, H.2    Capolino, G.A.3
  • 26
    • 40449096322 scopus 로고    scopus 로고
    • Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault diagnosis
    • Feb.
    • B. Akin, U. Orguner, H.A. Toliyat, and M. Rayner, "Low order PWM inverter harmonics contributions to the inverter-fed induction machine fault diagnosis," IEEE Trans. on Ind. Electron., Vol. 55, no. 2, pp. 610-619, Feb. 2008.
    • (2008) IEEE Trans. on Ind. Electron. , vol.55 , Issue.2 , pp. 610-619
    • Akin, B.1    Orguner, U.2    Toliyat, H.A.3    Rayner, M.4
  • 27
    • 0004134267 scopus 로고    scopus 로고
    • Madison, WI: Wisconsin Power Electronics Research Center, Univ. Wisconsin
    • T.A. Lipo, Introduction to AC machine design. Madison, WI: Wisconsin Power Electronics Research Center, Univ. Wisconsin, 2007.
    • (2007) Introduction to AC Machine Design
    • Lipo, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.