-
1
-
-
77955504672
-
Continuous glucose monitoring: Realtime algorithms for calibration, filtering, and alarms
-
Mar
-
B.W. Bequette. Continuous glucose monitoring: realtime algorithms for calibration, filtering, and alarms. J Diabetes Sci Technol, 4(2):404-18, Mar 2010.
-
(2010)
J Diabetes Sci Technol
, vol.4
, Issue.2
, pp. 404-418
-
-
Bequette, B.W.1
-
3
-
-
1642416875
-
Missed insulin meal boluses and elevated hemoglobin A1c levels in children receiving insulin pump therapy
-
Mar
-
J. Burdick, H. P. Chase, R. H. Slover, K. Knievel, L. Scrimgeour, A. K. Maniatis, and G. J. Klingensmith. Missed insulin meal boluses and elevated hemoglobin A1c levels in children receiving insulin pump therapy. Pediatrics, 113(3 Pt 1):e221-224, Mar 2004.
-
(2004)
Pediatrics
, vol.113
, Issue.3
, pp. e221-224
-
-
Burdick, J.1
Chase, H.P.2
Slover, R.H.3
Knievel, K.4
Scrimgeour, L.5
Maniatis, A.K.6
Klingensmith, G.J.7
-
4
-
-
77954454354
-
Diabetes: Models, signals, and control
-
Jan
-
C. Cobelli, C. D. Man, G. Sparacino, L. Magni, G. De Nicolao, and B. P. Kovatchev. Diabetes: Models, Signals, and Control. IEEE Rev Biomed Eng, 2:54-96, Jan 2009.
-
(2009)
IEEE Rev Biomed Eng
, vol.2
, pp. 54-96
-
-
Cobelli, C.1
Man, C.D.2
Sparacino, G.3
Magni, L.4
De Nicolao, G.5
Kovatchev, B.P.6
-
5
-
-
80755148728
-
Artificial pancreas: Past, present, future
-
Nov
-
C. Cobelli, E. Renard, and B. Kovatchev. Artificial pancreas: past, present, future. Diabetes, 60(11):2672-2682, Nov 2011.
-
(2011)
Diabetes
, vol.60
, Issue.11
, pp. 2672-2682
-
-
Cobelli, C.1
Renard, E.2
Kovatchev, B.3
-
6
-
-
84896872193
-
The UVa/Padova type 1 diabetes simulator: New features
-
in press
-
C. Dalla Man, F. Micheletto, D. Lv, M. Breton, B. Kovatchev, and C. Cobelli. The UVa/Padova type 1 diabetes simulator: new features. J Diabetes Sci Technol, in press.
-
J Diabetes Sci Technol
-
-
Dalla Man, C.1
Micheletto, F.2
Lv, D.3
Breton, M.4
Kovatchev, B.5
Cobelli, C.6
-
7
-
-
84872538703
-
An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects
-
Feb.
-
A. Facchinetti, S. Del Favero, G. Sparacino, and C. Cobelli. An online failure detection method of the glucose sensor-insulin pump system: Improved overnight safety of type-1 diabetic subjects. IEEE Transactions on Biomedical Engineering, 60(2):406-16, Feb. 2013.
-
(2013)
IEEE Transactions on Biomedical Engineering
, vol.60
, Issue.2
, pp. 406-416
-
-
Facchinetti, A.1
Del Favero, S.2
Sparacino, G.3
Cobelli, C.4
-
9
-
-
70949107024
-
Insulin pump failures are still frequent: A prospective study over 6 years from 2001 to 2007
-
Dec
-
I. Guilhem, B. Balkau, F. Lecordier, J. M. Malecot, S. Elbadii, A. M. Leguerrier, J. Y. Poirier, C. Derrien, and F. Bonnet. Insulin pump failures are still frequent: a prospective study over 6 years from 2001 to 2007. Diabetologia, 52:2662-2664, Dec 2009.
-
(2009)
Diabetologia
, vol.52
, pp. 2662-2664
-
-
Guilhem, I.1
Balkau, B.2
Lecordier, F.3
Malecot, J.M.4
Elbadii, S.5
Leguerrier, A.M.6
Poirier, J.Y.7
Derrien, C.8
Bonnet, F.9
-
10
-
-
84858756238
-
Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response - Part II: Examples and application
-
May
-
K. L. Helton, B. D. Ratner, and N. A. Wisniewski. Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and foreign body response-part II: examples and application. J Diabetes Sci Technol, 5:647-656, May 2011.
-
(2011)
J Diabetes Sci Technol
, vol.5
, pp. 647-656
-
-
Helton, K.L.1
Ratner, B.D.2
Wisniewski, N.A.3
-
11
-
-
84869083356
-
Robust fault detection system for insulin pump therapy using continuous glucose monitoring
-
Sep
-
P. Herrero, R. Calm, J. Veh, J. Armengol, P. Georgiou, N. Oliver, and C. Tomazou. Robust fault detection system for insulin pump therapy using continuous glucose monitoring. J Diabetes Sci Technol, 6(5):1131-41, Sep 2012.
-
(2012)
J Diabetes Sci Technol
, vol.6
, Issue.5
, pp. 1131-1141
-
-
Herrero, P.1
Calm, R.2
Veh, J.3
Armengol, J.4
Georgiou, P.5
Oliver, N.6
Tomazou, C.7
-
12
-
-
33645051466
-
Continuous glucose monitoring and closed-loop systems
-
Jan
-
R. Hovorka. Continuous glucose monitoring and closed-loop systems. Diabet. Med., 23:1-12, Jan 2006.
-
(2006)
Diabet. Med.
, vol.23
, pp. 1-12
-
-
Hovorka, R.1
-
13
-
-
14844348762
-
Subspace identification of closed-loop systems by orthogonal decomposition
-
May
-
T. Katayama, H. Kawauchi, and G. Picci. Subspace identification of closed-loop systems by orthogonal decomposition. Automatica, 41:863-872, May 2005.
-
(2005)
Automatica
, vol.41
, pp. 863-872
-
-
Katayama, T.1
Kawauchi, H.2
Picci, G.3
-
14
-
-
84055225002
-
-
Patent
-
B.P. Kovatchev, M.D. Breton, C. Cobelli, and C. Dalla Man. Method, system and computer simulation environment for testing of monitoring and control strategies in diabetes. Patent WO/2008/157781, 2008.
-
(2008)
Method, System and Computer Simulation Environment for Testing of Monitoring and Control Strategies in Diabetes
-
-
Kovatchev, B.P.1
Breton, M.D.2
Cobelli, C.3
Dalla Man, C.4
-
15
-
-
61549086161
-
Missed bolus doses: Devastating for metabolic control in CSII-treated adolescents with type 1 diabetes
-
Apr
-
A. L. Olinder, A. Kernell, and B. Smide. Missed bolus doses: devastating for metabolic control in CSII-treated adolescents with type 1 diabetes. Pediatr Diabetes, 10 (2):142-148, Apr 2009.
-
(2009)
Pediatr Diabetes
, vol.10
, Issue.2
, pp. 142-148
-
-
Olinder, A.L.1
Kernell, A.2
Smide, B.3
-
16
-
-
79957459988
-
Reasons for missed meal-time insulin boluses from the perspective of adolescents using insulin pumps: 'lost focus'
-
Jun
-
A. L. Olinder, K. T. Nyhlin, and B. Smide. Reasons for missed meal-time insulin boluses from the perspective of adolescents using insulin pumps: 'lost focus'. Pediatr Diabetes, 12(4 Pt 2):402-409, Jun 2011.
-
(2011)
Pediatr Diabetes
, vol.12
, Issue.4
, pp. 402-409
-
-
Olinder, A.L.1
Nyhlin, K.T.2
Smide, B.3
-
17
-
-
84860116942
-
Insulin-pump therapy for type 1 diabetes mellitus
-
Apr
-
J. C. Pickup. Insulin-pump therapy for type 1 diabetes mellitus. N. Engl. J. Med., 366(17):1616-1624, Apr 2012.
-
(2012)
N. Engl. J. Med.
, vol.366
, Issue.17
, pp. 1616-1624
-
-
Pickup, J.C.1
-
18
-
-
52649159745
-
Insulin treatment. ISPAD clinical practice consensus guidelines 2006-2007. Type 2 diabetes mellitus in the child and adolescent
-
Oct
-
A. L. Rosenbloom, J. H. Silverstein, S. Amemiya, P. Zeitler, and G. J. Klingensmith. Insulin treatment. ISPAD Clinical Practice Consensus Guidelines 2006-2007. Type 2 diabetes mellitus in the child and adolescent. Pediatr Diabetes, 9(5):512-526, Oct 2008.
-
(2008)
Pediatr Diabetes
, vol.9
, Issue.5
, pp. 512-526
-
-
Rosenbloom, A.L.1
Silverstein, J.H.2
Amemiya, S.3
Zeitler, P.4
Klingensmith, G.J.5
-
19
-
-
78049488149
-
Pilot study for assessment of optimal frequency for changing catheters in insulin pump therapy-trouble starts on day 3
-
Jul
-
V. Schmid, C. Hohberg, M. Borchert, T. Forst, and A. Pfutzner. Pilot study for assessment of optimal frequency for changing catheters in insulin pump therapy-trouble starts on day 3. J Diabetes Sci Technol, 4:976-982, Jul 2010.
-
(2010)
J Diabetes Sci Technol
, vol.4
, pp. 976-982
-
-
Schmid, V.1
Hohberg, C.2
Borchert, M.3
Forst, T.4
Pfutzner, A.5
-
20
-
-
84898956772
-
Artificial pancreas: MPC design from clinical experience
-
Nov
-
C. Toffanin, M. Messori, F. Di Palma, G. De Nicolao, C. Cobelli, and L. Magni. Artificial pancreas: MPC design from clinical experience. Journal of Diabetes Science and Technology, 7(6):1470-1483, Nov 2013.
-
(2013)
Journal of Diabetes Science and Technology
, vol.7
, Issue.6
, pp. 1470-1483
-
-
Toffanin, C.1
Messori, M.2
Di Palma, F.3
De Nicolao, G.4
Cobelli, C.5
Magni, L.6
-
21
-
-
84860590392
-
Significant time until catheter occlusion alerts in currently marketed insulin pumps at two basal rates
-
May
-
A. C. van Bon, D. Dragt, and J. H. Devries. Significant time until catheter occlusion alerts in currently marketed insulin pumps at two Basal rates. Diabetes Technol. Ther., 14(5):447-448, May 2012.
-
(2012)
Diabetes Technol. Ther.
, vol.14
, Issue.5
, pp. 447-448
-
-
Van Bon, A.C.1
Dragt, D.2
Devries, J.H.3
|