메뉴 건너뛰기




Volumn , Issue , 2014, Pages 4212-4215

ECG-EMG separation by using enhanced non-negative matrix factorization

Author keywords

[No Author keywords available]

Indexed keywords

ELECTROCARDIOGRAPHY; FACTORIZATION; MIXTURES; SEPARATION; SPECTROGRAPHS;

EID: 84929493401     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2014.6944553     Document Type: Conference Paper
Times cited : (14)

References (15)
  • 1
    • 0027459844 scopus 로고
    • High-pass filtering to remove electrocardiographic interference from torso EMG recordings
    • M. S. Redfern, R. E. Hughes, and D. B. Chaffin, "High-pass filtering to remove electrocardiographic interference from torso EMG recordings", Clin. Biomech., Vol. 8, pp. 44-48, 1993.
    • (1993) Clin. Biomech. , vol.8 , pp. 44-48
    • Redfern, M.S.1    Hughes, R.E.2    Chaffin, D.B.3
  • 2
    • 0034283148 scopus 로고    scopus 로고
    • New aspects to eventsynchronous cancellation of ECG interference: An application of the method in diaphragmatic EMG signals
    • Sep.
    • Y. Deng, W. Wolf, and R. Schnell, "New aspects to eventsynchronous cancellation of ECG interference: An application of the method in diaphragmatic EMG signals," IEEE Trans. Biomed. Eng., Vol. 47, no. 9, pp. 1177-1184, Sep. 2000.
    • (2000) IEEE Trans. Biomed. Eng. , vol.47 , Issue.9 , pp. 1177-1184
    • Deng, Y.1    Wolf, W.2    Schnell, R.3
  • 5
    • 79959294306 scopus 로고    scopus 로고
    • Removal of the electrocardiogram signal from surface EMG recordings using nonlinearly scaled wavelets
    • Aug.
    • V. von Tscharner, B. Eskofier, and P. Federolf, "Removal of the electrocardiogram signal from surface EMG recordings using nonlinearly scaled wavelets," J. Electromyogr. Kinesiol., Vol. 21, no. 4, pp. 683-688, Aug. 2011.
    • (2011) J. Electromyogr. Kinesiol. , vol.21 , Issue.4 , pp. 683-688
    • Von Tscharner, V.1    Eskofier, B.2    Federolf, P.3
  • 6
    • 77956419221 scopus 로고    scopus 로고
    • An automated ECG-artifact removal method for trunk muscle surface EMG recordings
    • Oct.
    • J. Mak, Y. Hu, and K. Luk, "An automated ECG-artifact removal method for trunk muscle surface EMG recordings," Med. Eng. Phys., Vol. 32, no. 8, pp. 840-848, Oct. 2010.
    • (2010) Med. Eng. Phys. , vol.32 , Issue.8 , pp. 840-848
    • Mak, J.1    Hu, Y.2    Luk, K.3
  • 8
    • 50249152311 scopus 로고    scopus 로고
    • Monaural sound source separation by non negative matrix factorization with temporal continuity and sparseness criteria
    • T. Virtanen, "Monaural sound source separation by non negative matrix factorization with temporal continuity and sparseness criteria," IEEE Trans. on Audio, Speech and Language Processing, Vol. 15, no. 3, pp. 1066-1074, 2007.
    • (2007) IEEE Trans. on Audio, Speech and Language Processing , vol.15 , Issue.3 , pp. 1066-1074
    • Virtanen, T.1
  • 11
    • 8344265287 scopus 로고    scopus 로고
    • Recognition from EMG signals by an evolutional method and non-negative matrix factorization
    • Y. Yazama, Y. Mitsukura, M. Fukumi, N. Akamatsu, "Recognition from EMG Signals by an Evolutional Method and Non-negative Matrix Factorization" Lecture Notes in Computer Science 2773, pp. 594-600, 2003.
    • (2003) Lecture Notes in Computer Science , vol.2773 , pp. 594-600
    • Yazama, Y.1    Mitsukura, Y.2    Fukumi, M.3    Akamatsu, N.4
  • 12
    • 0033592606 scopus 로고    scopus 로고
    • Learning the parts of objects by non-negative matrix factorization
    • D. Lee and H. S. Seung, "Learning the parts of objects by non-negative matrix factorization", Nature, 401:788-791, 1999.
    • (1999) Nature , vol.401 , pp. 788-791
    • Lee, D.1    Seung, H.S.2
  • 13
    • 84898964201 scopus 로고    scopus 로고
    • Algorithms for non-negative matrix factorization
    • V. T. Todd Leen, Tom Dietterich, editor MIT Press, Cambridge, MA
    • D. Lee and H. S. Seung, "Algorithms for non-negative matrix factorization", In V. T. Todd Leen, Tom Dietterich, editor, Advances in Neural Information Processing Systems 13, pages 556-562. MIT Press, Cambridge, MA, 2001.
    • (2001) Advances in Neural Information Processing Systems , vol.13 , pp. 556-562
    • Lee, D.1    Seung, H.S.2
  • 15
    • 77951090874 scopus 로고    scopus 로고
    • A wavelet-based adaptive filter for removing ECG interference in EMGdi signals
    • C. Zhan, L. F. Yeung, and Z. Yang, "A wavelet-based adaptive filter for removing ECG interference in EMGdi signals," J. Electromyogr. Kinesiol. no. 20, pp. 542-549, 2010.
    • (2010) J. Electromyogr. Kinesiol , Issue.20 , pp. 542-549
    • Zhan, C.1    Yeung, L.F.2    Yang, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.