-
1
-
-
0026880567
-
Adaptive cancellation technique in processing myoelectric activity of respiratory muscles
-
Akkiraju P., Reddy D.C. Adaptive cancellation technique in processing myoelectric activity of respiratory muscles. IEEE Trans Biomed Eng 1992, 39(6):652-655.
-
(1992)
IEEE Trans Biomed Eng
, vol.39
, Issue.6
, pp. 652-655
-
-
Akkiraju, P.1
Reddy, D.C.2
-
2
-
-
56049119916
-
Frequency and conduction velocity analysis of the abductor pollicis brevis muscle during early fatigue
-
Barandun M., von Tscharner V., Meuli-Simmen C., Bowen V., Valderrabano V. Frequency and conduction velocity analysis of the abductor pollicis brevis muscle during early fatigue. J Electromyogr Kinesiol 2009, 19(1):65-74.
-
(2009)
J Electromyogr Kinesiol
, vol.19
, Issue.1
, pp. 65-74
-
-
Barandun, M.1
von Tscharner, V.2
Meuli-Simmen, C.3
Bowen, V.4
Valderrabano, V.5
-
3
-
-
0030054365
-
Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination
-
Bartolo A., Roberts C., Dzwonczyk R.R., Goldman E. Analysis of diaphragm EMG signals: comparison of gating vs. subtraction for removal of ECG contamination. J Appl Physiol 1996, 80(6):1898-1902.
-
(1996)
J Appl Physiol
, vol.80
, Issue.6
, pp. 1898-1902
-
-
Bartolo, A.1
Roberts, C.2
Dzwonczyk, R.R.3
Goldman, E.4
-
4
-
-
0034283148
-
New aspects to event-synchronous cancellation of ECG interference. an application of the method in diaphragmatic EMG signals
-
Deng Y., Wolf W., Schnell R., Appel U. New aspects to event-synchronous cancellation of ECG interference. an application of the method in diaphragmatic EMG signals. IEEE Trans Biomed Eng 2000, 47(9):1177-1184.
-
(2000)
IEEE Trans Biomed Eng
, vol.47
, Issue.9
, pp. 1177-1184
-
-
Deng, Y.1
Wolf, W.2
Schnell, R.3
Appel, U.4
-
5
-
-
31544456329
-
Elimination of electrocardiogram contamination from electromyogram signals: An evaluation of currently used removal techniques
-
Drake J.D., Callaghan J.P. Elimination of electrocardiogram contamination from electromyogram signals: An evaluation of currently used removal techniques. J Electromyogr Kinesiol 2006, 16(2):175-187.
-
(2006)
J Electromyogr Kinesiol
, vol.16
, Issue.2
, pp. 175-187
-
-
Drake, J.D.1
Callaghan, J.P.2
-
7
-
-
58149170158
-
Counterpoint: spectral properties of the surface EMG do not provide information about motor unit recruitment and muscle fiber type
-
Farina D. Counterpoint: spectral properties of the surface EMG do not provide information about motor unit recruitment and muscle fiber type. J Appl Physiol 2008, 105(5):1673-1674.
-
(2008)
J Appl Physiol
, vol.105
, Issue.5
, pp. 1673-1674
-
-
Farina, D.1
-
8
-
-
67650506053
-
Removing ECG noise from surface EMG signals using adaptive filtering
-
Guohua L., Brittain J.S., Holland P., Yianni J., Green A.L., Stein J.F., et al. Removing ECG noise from surface EMG signals using adaptive filtering. Neurosci Lett 2009, 462(1):14-19.
-
(2009)
Neurosci Lett
, vol.462
, Issue.1
, pp. 14-19
-
-
Guohua, L.1
Brittain, J.S.2
Holland, P.3
Yianni, J.4
Green, A.L.5
Stein, J.F.6
-
9
-
-
70350568756
-
A simple method to remove ECG artifacts from trunk muscle EMG signals
-
Hof A.L. A simple method to remove ECG artifacts from trunk muscle EMG signals. J Electromyogr Kinesiol 2009, 19(6):e554-e555.
-
(2009)
J Electromyogr Kinesiol
, vol.19
, Issue.6
-
-
Hof, A.L.1
-
11
-
-
65849095920
-
Signal processing of the surface electromyogram to gain insight into neuromuscular physiology
-
Karlsson J.S., Roeleveld K., Grönlund C., Holtermann A., Ostlund N. Signal processing of the surface electromyogram to gain insight into neuromuscular physiology. Philos Transact A Math Phys Eng Sci 2009, 367(1887):337-356.
-
(2009)
Philos Transact A Math Phys Eng Sci
, vol.367
, Issue.1887
, pp. 337-356
-
-
Karlsson, J.S.1
Roeleveld, K.2
Grönlund, C.3
Holtermann, A.4
Ostlund, N.5
-
12
-
-
14844310267
-
Aptive filtering for ECG rejection from surface EMG recordings
-
Marque C., Bisch C., Dantas R., Elayoubi S., Brosse V., Pérot C. Aptive filtering for ECG rejection from surface EMG recordings. J Electromyogr Kinesiol 2005, 15(3):310-315.
-
(2005)
J Electromyogr Kinesiol
, vol.15
, Issue.3
, pp. 310-315
-
-
Marque, C.1
Bisch, C.2
Dantas, R.3
Elayoubi, S.4
Brosse, V.5
Pérot, C.6
-
13
-
-
33750940946
-
Noise reduction based on ICA decomposition and wavelet transform for the extraction of motor unit action potentials
-
Ren X., Yan Z., Wang Z., Hu X. Noise reduction based on ICA decomposition and wavelet transform for the extraction of motor unit action potentials. J Neurosci Method 2006, 158(2):313-322.
-
(2006)
J Neurosci Method
, vol.158
, Issue.2
, pp. 313-322
-
-
Ren, X.1
Yan, Z.2
Wang, Z.3
Hu, X.4
-
14
-
-
77955173027
-
Estimation of handgrip force using frequency-band technique during fatiguing muscle contraction
-
Soo Y., Sugi M., Yokoi H., Arai T., Nishino M., Kato R., et al. Estimation of handgrip force using frequency-band technique during fatiguing muscle contraction. J Electromyogr Kinesiol 2009, 10.1016/j.jelekin.2009.08.00.
-
(2009)
J Electromyogr Kinesiol
-
-
Soo, Y.1
Sugi, M.2
Yokoi, H.3
Arai, T.4
Nishino, M.5
Kato, R.6
-
15
-
-
57649188210
-
Wavelet-independent component analysis to remove electrocardiography contamination in surface electromyography
-
Taelman J., Van Huffel S., Spaepen A. Wavelet-independent component analysis to remove electrocardiography contamination in surface electromyography. Conf Proc IEEE Eng Med Biol Soc 2007, 2007:682-685.
-
(2007)
Conf Proc IEEE Eng Med Biol Soc
, vol.2007
, pp. 682-685
-
-
Taelman, J.1
Van Huffel, S.2
Spaepen, A.3
-
16
-
-
0035878735
-
Removal of ECG interference from the EEG recordings in small animals using independent component analysis
-
Tong S., Bezerianos A., Paul J., Zhu Y., Thakor N. Removal of ECG interference from the EEG recordings in small animals using independent component analysis. J Neurosci Method 2001, 108(1):11-17.
-
(2001)
J Neurosci Method
, vol.108
, Issue.1
, pp. 11-17
-
-
Tong, S.1
Bezerianos, A.2
Paul, J.3
Zhu, Y.4
Thakor, N.5
-
17
-
-
0033728881
-
Intensity analysis in time-frequency space of surface myoelectric signals by wavelets of specified resolution
-
von Tscharner V. Intensity analysis in time-frequency space of surface myoelectric signals by wavelets of specified resolution. J Electromyogr Kinesiol 2000, 10(6):433-445.
-
(2000)
J Electromyogr Kinesiol
, vol.10
, Issue.6
, pp. 433-445
-
-
von Tscharner, V.1
-
18
-
-
77952955600
-
-
Classification of multi muscle activation patterns of osteoarthritis patients during level walking. J Electromyogr Kinesiol [Epub ahead of print] doi:10.1016/j.jelekin.2009.11.005
-
von Tscharner V, Valderrabano V. Classification of multi muscle activation patterns of osteoarthritis patients during level walking. J Electromyogr Kinesiol [Epub ahead of print] doi:10.1016/j.jelekin.2009.11.005.
-
-
-
von Tscharner, V.1
Valderrabano, V.2
-
19
-
-
31544461209
-
Estimation of the interplay between groups of fast and slow muscle fibers of the tibialis anterior and gastrocnemius muscle while running
-
von Tscharner V., Goepfert B. Estimation of the interplay between groups of fast and slow muscle fibers of the tibialis anterior and gastrocnemius muscle while running. J Electromyogr Kinesiol 2006, 16(2):188-197.
-
(2006)
J Electromyogr Kinesiol
, vol.16
, Issue.2
, pp. 188-197
-
-
von Tscharner, V.1
Goepfert, B.2
-
20
-
-
57349153027
-
Point: spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type
-
von Tscharner V., Nigg B.M. Point: spectral properties of the surface EMG can characterize/do not provide information about motor unit recruitment strategies and muscle fiber type. J Appl Physiol 2008, 105(5):1671-1673.
-
(2008)
J Appl Physiol
, vol.105
, Issue.5
, pp. 1671-1673
-
-
von Tscharner, V.1
Nigg, B.M.2
-
21
-
-
0036326859
-
Determining patterns of motor recruitment during locomotion
-
Wakeling J.M., Kaya M., Temple G.K., Johnston I.A., Herzog W. Determining patterns of motor recruitment during locomotion. J Exp Biol 2002, 205(Pt 3):359-369.
-
(2002)
J Exp Biol
, vol.205
, Issue.PART 3
, pp. 359-369
-
-
Wakeling, J.M.1
Kaya, M.2
Temple, G.K.3
Johnston, I.A.4
Herzog, W.5
-
22
-
-
77951090874
-
A wavelet-based adaptive filter for removing ECG interference in EMGdi signals
-
Zhan C., Yeung L.F., Yang Z. A wavelet-based adaptive filter for removing ECG interference in EMGdi signals. J Electromyogr Kinesiol 2010, 20(3):542-549.
-
(2010)
J Electromyogr Kinesiol
, vol.20
, Issue.3
, pp. 542-549
-
-
Zhan, C.1
Yeung, L.F.2
Yang, Z.3
|