메뉴 건너뛰기




Volumn , Issue , 2014, Pages 6699-6701

Validation of computational fluid dynamics methods with anatomically exact, 3D printed MRI phantoms and 4D pcMRI

Author keywords

[No Author keywords available]

Indexed keywords

3D PRINTERS; COST EFFECTIVENESS; MAGNETIC RESONANCE IMAGING; PHANTOMS; SCANNING;

EID: 84929484270     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2014.6945165     Document Type: Conference Paper
Times cited : (19)

References (11)
  • 1
    • 84862530589 scopus 로고    scopus 로고
    • Intracranial aneurysms, cancer, x-rays, and computational fluid dynamics
    • Jun.
    • C. M. Strother and J. Jiang, "Intracranial aneurysms, cancer, x-rays, and computational fluid dynamics," AJNR Am J Neuroradiol, Vol. 33, pp. 991-2, Jun.
    • AJNR Am J Neuroradiol , vol.33 , pp. 991-992
    • Strother, C.M.1    Jiang, J.2
  • 2
    • 84858649371 scopus 로고    scopus 로고
    • Counterpoint: Realizing the clinical utility of computational fluid dynamics - Closing the gap
    • Mar.
    • J. R. Cebral and H. Meng, "Counterpoint: realizing the clinical utility of computational fluid dynamics - closing the gap," AJNR Am J Neuroradiol, Vol. 33, pp. 396-8, Mar.
    • AJNR Am J Neuroradiol , vol.33 , pp. 396-398
    • Cebral, J.R.1    Meng, H.2
  • 3
    • 84856965554 scopus 로고    scopus 로고
    • Comprehensive validation of computational fluid dynamics simulations of in-vivo blood flow in patient-specific cerebral aneurysms
    • Feb.
    • Q. Sun, A. Groth, and T. Aach, "Comprehensive validation of computational fluid dynamics simulations of in-vivo blood flow in patient-specific cerebral aneurysms," Med Phys, Vol. 39, pp. 742-54, Feb.
    • Med Phys , vol.39 , pp. 742-754
    • Sun, Q.1    Groth, A.2    Aach, T.3
  • 4
    • 77956331218 scopus 로고    scopus 로고
    • Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms
    • Sep.
    • Q. Sun, A. Groth, M. Bertram, I. Waechter, T. Bruijns, R. Hermans, and T. Aach, "Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms," Med Phys, Vol. 37, pp. 5054-65, Sep.
    • Med Phys , vol.37 , pp. 5054-5065
    • Sun, Q.1    Groth, A.2    Bertram, M.3    Waechter, I.4    Bruijns, T.5    Hermans, R.6    Aach, T.7
  • 6
    • 58249087210 scopus 로고    scopus 로고
    • Evaluation of intracranial aneurysms with 7 T versus 1. 5 T time-of-flight MR angiography - Initial experience
    • Jan
    • C. Monninghoff, S. Maderwald, J. M. Theysohn, O. Kraff, S. C. Ladd, M. E. Ladd, M. Forsting, H. H. Quick, and I. Wanke, "Evaluation of intracranial aneurysms with 7 T versus 1. 5 T time-of-flight MR angiography - initial experience," Rofo, Vol. 181, pp. 16-23, Jan 2009.
    • (2009) Rofo , vol.181 , pp. 16-23
    • Monninghoff, C.1    Maderwald, S.2    Theysohn, J.M.3    Kraff, O.4    Ladd, S.C.5    Ladd, M.E.6    Forsting, M.7    Quick, H.H.8    Wanke, I.9
  • 7
    • 80855134306 scopus 로고    scopus 로고
    • Flow characteristics in a canine aneurysm model: A comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations
    • Nov.
    • J. Jiang, K. Johnson, K. Valen-Sendstad, K. A. Mardal, O. Wieben, and C. Strother, "Flow characteristics in a canine aneurysm model: a comparison of 4D accelerated phase-contrast MR measurements and computational fluid dynamics simulations," Med Phys, Vol. 38, pp. 6300-12, Nov.
    • Med Phys , vol.38 , pp. 6300-6312
    • Jiang, J.1    Johnson, K.2    Valen-Sendstad, K.3    Mardal, K.A.4    Wieben, O.5    Strother, C.6
  • 8
    • 78650816491 scopus 로고    scopus 로고
    • In-vivo quantification of wall motion in cerebral aneurysms from 2D cine phase contrast magnetic resonance images
    • Oct 26
    • C. Karmonik, O. Diaz, R. Grossman, and R. Klucznik, "In-Vivo Quantification of Wall Motion in Cerebral Aneurysms from 2D Cine Phase Contrast Magnetic Resonance Images," Rofo, Oct 26 2009.
    • (2009) Rofo
    • Karmonik, C.1    Diaz, O.2    Grossman, R.3    Klucznik, R.4
  • 9
    • 47849110068 scopus 로고    scopus 로고
    • Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD
    • C. Karmonik, R. Klucznik, and G. Benndorf, "Comparison of velocity patterns in an AComA aneurysm measured with 2D phase contrast MRI and simulated with CFD," Technol Health Care, Vol. 16, pp. 119-28, 2008.
    • (2008) Technol Health Care , vol.16 , pp. 119-128
    • Karmonik, C.1    Klucznik, R.2    Benndorf, G.3
  • 10
    • 84885109943 scopus 로고    scopus 로고
    • Quantification of speed-up and accuracy of multi-CPU computational flow dynamics simulations of hemodynamics in a posterior communicating artery aneurysm of complex geometry
    • Nov.
    • C. Karmonik, C. Yen, E. Gabriel, S. Partovi, M. Horner, Y. J. Zhang, R. P. Klucznik, O. Diaz, and R. G. Grossman, "Quantification of speed-up and accuracy of multi-CPU computational flow dynamics simulations of hemodynamics in a posterior communicating artery aneurysm of complex geometry," J Neurointerv Surg, Vol. 5 Suppl 3, pp. iii48-55, Nov.
    • J Neurointerv Surg , vol.5 , pp. iii4855
    • Karmonik, C.1    Yen, C.2    Gabriel, E.3    Partovi, S.4    Horner, M.5    Zhang, Y.J.6    Klucznik, R.P.7    Diaz, O.8    Grossman, R.G.9
  • 11
    • 42949160153 scopus 로고    scopus 로고
    • Blood flow in cerebral aneurysms: Comparison of phase contrast magnetic resonance and computational fluid dynamics - Preliminary experience
    • Mar
    • C. Karmonik, R. Klucznik, and G. Benndorf, "Blood flow in cerebral aneurysms: comparison of phase contrast magnetic resonance and computational fluid dynamics - preliminary experience," Rofo, Vol. 180, pp. 209-15, Mar 2008.
    • (2008) Rofo , vol.180 , pp. 209-215
    • Karmonik, C.1    Klucznik, R.2    Benndorf, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.