메뉴 건너뛰기




Volumn 37, Issue 9, 2010, Pages 5054-5065

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Author keywords

aneurysm; CFD simulation; sensitivity analysis; time intensity curve; virtual angiography

Indexed keywords

DECISION MAKING; FLOW FIELDS; MEAN SQUARE ERROR; PARAMETER ESTIMATION; PHANTOMS; RELIABILITY; RISK ASSESSMENT; SENSITIVITY ANALYSIS;

EID: 77956331218     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3483066     Document Type: Article
Times cited : (20)

References (31)
  • 1
    • 24644456444 scopus 로고    scopus 로고
    • Ruptured intracranial aneurysms in the elderly: Epidemiology, diagnosis, and management
    • 10.1385/NCC:2:2:119 1541-6933
    • J. Sedat, M. Dib, D. Rasendrarijao, D. Fontaine, M. Lonjon, and P. Paquis, " Ruptured intracranial aneurysms in the elderly: epidemiology, diagnosis, and management.," Neurocrit. Care 2, 119-123 (2005). 10.1385/NCC:2:2:119 1541-6933
    • (2005) Neurocrit. Care , vol.2 , pp. 119-123
    • Sedat, J.1    Dib, M.2    Rasendrarijao, D.3    Fontaine, D.4    Lonjon, M.5    Paquis, P.6
  • 2
    • 54849426265 scopus 로고    scopus 로고
    • Numerical simulations of flow in cerebral aneurysms: Comparison of CFD results and in vivo MRI measurements
    • JBENDY 0148-0731 .10.1115/1.2970056
    • V. L. Rayz, L. Boussel, G. Acevedo-Bolton, A. J. Martin, W. L. Young, M. T. Lawton, R. Higashida, and D. Saloner, " Numerical simulations of flow in cerebral aneurysms: Comparison of CFD results and in vivo MRI measurements.," J. Biomech. Eng. JBENDY 0148-0731 130 (5), 051011-1-051011-9 (2008). 10.1115/1.2970056
    • (2008) J. Biomech. Eng. , vol.130 , Issue.5 , pp. 0510111-0510119
    • Rayz, V.L.1    Boussel, L.2    Acevedo-Bolton, G.3    Martin, A.J.4    Young, W.L.5    Lawton, M.T.6    Higashida, R.7    Saloner, D.8
  • 3
    • 77956314547 scopus 로고    scopus 로고
    • PIV validation of pulsatile flow in a patient specific aneurysm CFD model
    • JBMCB5 0021-9290,. 10.1016/S0021-9290(06)84455-6
    • M. D. Ford, H. N. Nikolov, J. S. Milner, D. W. Holdsworth, and D. A. Steinman, " PIV validation of pulsatile flow in a patient specific aneurysm CFD model.," J. Biomech. JBMCB5 0021-9290 39, S363 (2006). 10.1016/S0021-9290(06)84455-6
    • (2006) J. Biomech. , vol.39 , pp. 363
    • Ford, M.D.1    Nikolov, H.N.2    Milner, J.S.3    Holdsworth, D.W.4    Steinman, D.A.5
  • 4
    • 29144522244 scopus 로고    scopus 로고
    • Virtual angiography for visualization and validation of computational fluid dynamics models of aneurysm hemodynamics
    • ITMID4 0278-0062,. 10.1109/TMI.2005.859204
    • M. D. Ford, G. R. Stuhne, H. N. Nikolov, D. F. Habets, S. P. Lownie, D. W. Holdsworth, and D. A. Steinman, " Virtual angiography for visualization and validation of computational fluid dynamics models of aneurysm hemodynamics.," IEEE Trans. Med. Imaging ITMID4 0278-0062 24, 1586-1592 (2005). 10.1109/TMI.2005.859204
    • (2005) IEEE Trans. Med. Imaging , vol.24 , pp. 1586-1592
    • Ford, M.D.1    Stuhne, G.R.2    Nikolov, H.N.3    Habets, D.F.4    Lownie, S.P.5    Holdsworth, D.W.6    Steinman, D.A.7
  • 5
    • 34250197872 scopus 로고    scopus 로고
    • Computational fluid dynamics modeling of intracranial aneurysms: Qualitative comparison with cerebral angiography
    • ZZZZZZ 1076-6332,. 10.1016/j.acra.2007.03.008
    • J. R. Cebral, R. S. Pergolizzi, and C. M. Putman, " Computational fluid dynamics modeling of intracranial aneurysms: Qualitative comparison with cerebral angiography.," Acad. Radiol. ZZZZZZ 1076-6332 14, 804-813 (2007). 10.1016/j.acra.2007.03.008
    • (2007) Acad. Radiol. , vol.14 , pp. 804-813
    • Cebral, J.R.1    Pergolizzi, R.S.2    Putman, C.M.3
  • 9
    • 33846412594 scopus 로고    scopus 로고
    • Validation of CFD simulations of cerebral aneurysms with implication of geometric variations
    • JBENDY 0148-0731 .10.1115/1.2354209
    • Y. Hoi, S. H. Woodward, M. Kim, D. B. Taulbee, and H. Meng, " Validation of CFD simulations of cerebral aneurysms with implication of geometric variations.," J. Biomech. Eng. JBENDY 0148-0731 128 (6), 844-851 (2006). 10.1115/1.2354209
    • (2006) J. Biomech. Eng. , vol.128 , Issue.6 , pp. 844-851
    • Hoi, Y.1    Woodward, S.H.2    Kim, M.3    Taulbee, D.B.4    Meng, H.5
  • 10
    • 34447320750 scopus 로고    scopus 로고
    • Flow in simplified and real models of intracranial aneurysms
    • IJHFD2 0142-727X,. 10.1016/j.ijheatfluidflow.2007.04.004
    • G. Paál,. Ugron, I. Szikora, and I. Bojtár, " Flow in simplified and real models of intracranial aneurysms.," Int. J. Heat Fluid Flow IJHFD2 0142-727X 28, 653-664 (2007). 10.1016/j.ijheatfluidflow.2007.04.004
    • (2007) Int. J. Heat Fluid Flow , vol.28 , pp. 653-664
    • Paál, G.1    Ugron, .2    Szikora, I.3    Bojtár, I.4
  • 11
    • 72049085244 scopus 로고    scopus 로고
    • Computer-assisted extraction of intracranial aneurysms on 3D rotational angiograms for computational fluid dynamics modeling
    • MPHYA6 0094-2405,. 10.1118/1.3260841
    • H. H. Chang, G. R. Duckwiler, D. J. Valentine, and W. C. Chu, " Computer-assisted extraction of intracranial aneurysms on 3D rotational angiograms for computational fluid dynamics modeling.," Med. Phys. MPHYA6 0094-2405 36, 5612-5621 (2009). 10.1118/1.3260841
    • (2009) Med. Phys. , vol.36 , pp. 5612-5621
    • Chang, H.H.1    Duckwiler, G.R.2    Valentine, D.J.3    Chu, W.C.4
  • 14
    • 0000852893 scopus 로고
    • Effect of acute increase in intracranial pressure on blood flow in the internal carotid artery of man
    • JCINAO 0021-9738 .10.1172/JCI105239
    • J. C. Greenfield, Jr. and G. T. Tindall, " Effect of acute increase in intracranial pressure on blood flow in the internal carotid artery of man.," J. Clin. Invest. JCINAO 0021-9738 44 (8), 1343-1351 (1965). 10.1172/JCI105239
    • (1965) J. Clin. Invest. , vol.44 , Issue.8 , pp. 1343-1351
    • Greenfield Jr., J.C.1    Tindall, G.T.2
  • 15
    • 45749109840 scopus 로고    scopus 로고
    • Flow-area relationship in internal carotid and vertebral arteries
    • ZZZZZZ 0967-3334 .10.1088/0967-3334/29/5/005
    • J. R. Cebral, M. A. Castro, C. M. Putman, and N. Alperin, " Flow-area relationship in internal carotid and vertebral arteries.," Physiol. Meas ZZZZZZ 0967-3334 29 (5), 585-594 (2008). 10.1088/0967-3334/29/5/ 005
    • (2008) Physiol. Meas , vol.29 , Issue.5 , pp. 585-594
    • Cebral, J.R.1    Castro, M.A.2    Putman, C.M.3    Alperin, N.4
  • 16
    • 0029115929 scopus 로고
    • Middle cerebral artery blood flow velocity and stable xenon-enhanced computed tomographic blood flow during balloon test occlusion of the internal carotid artery
    • SJCCA7 0039-2499
    • W. A. Kofke, P. Brauer, R. Policare, S. Penthany, D. Barker, and J. Horton, " Middle cerebral artery blood flow velocity and stable xenon-enhanced computed tomographic blood flow during balloon test occlusion of the internal carotid artery.," Stroke SJCCA7 0039-2499 26, 1603-1606 (1995).
    • (1995) Stroke , vol.26 , pp. 1603-1606
    • Kofke, W.A.1    Brauer, P.2    Policare, R.3    Penthany, S.4    Barker, D.5    Horton, J.6
  • 17
    • 0034940509 scopus 로고    scopus 로고
    • Blood flow velocity in the middle cerebral artery in heavy alcohol drinkers
    • ZZZZZZ 0735-0414 .10.1093/alcalc/36.4.346
    • Z. Gdovinová, " Blood flow velocity in the middle cerebral artery in heavy alcohol drinkers.," Alcohol Alcohol ZZZZZZ 0735-0414 36 (4), 346-348 (2001). 10.1093/alcalc/36.4.346
    • (2001) Alcohol Alcohol , vol.36 , Issue.4 , pp. 346-348
    • Gdovinová, Z.1
  • 18
    • 0033918821 scopus 로고    scopus 로고
    • MRI measures of middle cerebral artery diameter in conscious humans during simulated orthostasis
    • SJCCA7 0039-2499 ()
    • J. M. Serrador, P. A. Picot, B. K. Rutt, J. K. Shoemaker, and R. L. Bondar, " MRI measures of middle cerebral artery diameter in conscious humans during simulated orthostasis.," Stroke SJCCA7 0039-2499 31 (7), 1672-1678 (2000).
    • (2000) Stroke , vol.31 , Issue.7 , pp. 1672-1678
    • Serrador, J.M.1    Picot, P.A.2    Rutt, B.K.3    Shoemaker, J.K.4    Bondar, R.L.5
  • 21
    • 17444424630 scopus 로고    scopus 로고
    • Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity
    • ITMID4 0278-0062,. 10.1109/TMI.2005.844159
    • J. R. Cebral, M. A. Castro, S. Appanaboyina, C. M. Putman, D. Millan, and A. F. Frangi, " Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity.," IEEE Trans. Med. Imaging ITMID4 0278-0062 24, 457-467 (2005). 10.1109/TMI.2005.844159
    • (2005) IEEE Trans. Med. Imaging , vol.24 , pp. 457-467
    • Cebral, J.R.1    Castro, M.A.2    Appanaboyina, S.3    Putman, C.M.4    Millan, D.5    Frangi, A.F.6
  • 22
    • 70350725913 scopus 로고    scopus 로고
    • The mixability of angiographic contrast with arterial blood
    • MPHYA6 0094-2405,. 10.1118/1.3243079
    • B. B. Lieber, C. Sadasivan, Q. Hao, J. Seong, and L. Cesar, " The mixability of angiographic contrast with arterial blood.," Med. Phys. MPHYA6 0094-2405 36, 5064-5078 (2009). 10.1118/1.3243079
    • (2009) Med. Phys. , vol.36 , pp. 5064-5078
    • Lieber, B.B.1    Sadasivan, C.2    Hao, Q.3    Seong, J.4    Cesar, L.5
  • 23
    • 34548843352 scopus 로고    scopus 로고
    • CFD analysis of viscous non-Newtonian flow under the influence of a superimposed rotational vibration
    • CPFLBI 0045-7930,. 10.1016/j.compfluid.2007.03.015
    • E. Eesa and M. Barigou, " CFD analysis of viscous non-Newtonian flow under the influence of a superimposed rotational vibration.," Comput. Fluids CPFLBI 0045-7930 37, 24-34 (2008). 10.1016/j.compfluid.2007.03.015
    • (2008) Comput. Fluids , vol.37 , pp. 24-34
    • Eesa, E.1    Barigou, M.2
  • 24
    • 46149142859 scopus 로고
    • Solution of the implicitly discretized fluid flow equation by operator splitting
    • JCTPAH 0021-9991,. 10.1016/0021-9991(86)90099-9
    • R. I. Issa, " Solution of the implicitly discretized fluid flow equation by operator splitting.," J. Comput. Phys. JCTPAH 0021-9991 62, 40-65 (1986). 10.1016/0021-9991(86)90099-9
    • (1986) J. Comput. Phys. , vol.62 , pp. 40-65
    • Issa, R.I.1
  • 25
    • 38349048315 scopus 로고    scopus 로고
    • Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass
    • ZZZZZZ 1010-7940,. 10.1016/j.ejcts.2007.11.021
    • Y. Tokuda, M. H. Song, Y. Ueda, A. Usui, T. Akita, S. Yoneyama, and S. Maruyama, " Three-dimensional numerical simulation of blood flow in the aortic arch during cardiopulmonary bypass.," Eur. J. Cardiothorac Surg. ZZZZZZ 1010-7940 33, 164-167 (2008). 10.1016/j.ejcts.2007.11.021
    • (2008) Eur. J. Cardiothorac Surg. , vol.33 , pp. 164-167
    • Tokuda, Y.1    Song, M.H.2    Ueda, Y.3    Usui, A.4    Akita, T.5    Yoneyama, S.6    Maruyama, S.7
  • 26
    • 33751209778 scopus 로고    scopus 로고
    • Patient-specific computational fluid dynamics modeling of anterior communicating artery aneurysms: A study of the sensitivity of intra-aneurysm flow patterns to flow conditions in the carotid arteries
    • ZZZZZZ 0195-6108
    • M. A. Castro, C. M. Putman, and J. R. Cebral, " Patient-specific computational fluid dynamics modeling of anterior communicating artery aneurysms: A study of the sensitivity of intra-aneurysm flow patterns to flow conditions in the carotid arteries.," AJNR Am. J. Neuroradiol. ZZZZZZ 0195-6108 27, 2061-2068 (2006).
    • (2006) AJNR Am. J. Neuroradiol. , vol.27 , pp. 2061-2068
    • Castro, M.A.1    Putman, C.M.2    Cebral, J.R.3
  • 27
    • 0037393677 scopus 로고    scopus 로고
    • Image-based computational simulation of flow dynamics in a giant intracranial aneurysm
    • ZZZZZZ 0195-6108
    • D. A. Steinmann, J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth, " Image-based computational simulation of flow dynamics in a giant intracranial aneurysm.," AJNR Am. J. Neuroradiol. ZZZZZZ 0195-6108 24, 556-566 (2003).
    • (2003) AJNR Am. J. Neuroradiol. , vol.24 , pp. 556-566
    • Steinmann, D.A.1    Milner, J.S.2    Norley, C.J.3    Lownie, S.P.4    Holdsworth, D.W.5
  • 28
    • 33845613667 scopus 로고    scopus 로고
    • The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: A CFD model compared to in vivo ultrasound measurement
    • JBMCB5 0021-9290,. 10.1016/j.jbiomech.2005.12.008
    • N. M. Maurits, G. E. Loots, and A. E. P. Veldman, " The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: A CFD model compared to in vivo ultrasound measurement.," J. Biomech. JBMCB5 0021-9290 40, 427-436 (2007). 10.1016/j.jbiomech.2005.12.008
    • (2007) J. Biomech. , vol.40 , pp. 427-436
    • Maurits, N.M.1    Loots, G.E.2    Veldman, A.E.P.3
  • 30
    • 0036146596 scopus 로고    scopus 로고
    • "Cerebral blood flow pulsatility deficits in HIV+poly substance abusers: Differences associated with antiviral medications
    • DADEDV 0376-8716,. 10.1016/S0376-8716(01)00158-2
    • R. I. Herning, K. Tate, W. Better, and J. L. Cadet, "Cerebral blood flow pulsatility deficits in HIV+poly substance abusers: Differences associated with antiviral medications.," Drug Alcohol Depend. DADEDV 0376-8716 65, 129-135 (2002). 10.1016/S0376-8716(01)00158-2
    • (2002) Drug Alcohol Depend. , vol.65 , pp. 129-135
    • Herning, R.I.1    Tate, K.2    Better, W.3    Cadet, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.