-
1
-
-
84455191520
-
Brain perfusion in asphyxiated newborns treated with therapeutic hypothermia
-
Wintermark P, Hansen A, Gregas MC, Soul J, Labrecque M, Robertson RL, Warfield SK., Brain perfusion in asphyxiated newborns treated with therapeutic hypothermia. AJNR Am J Neuroradiol 2011; 32: 2023-2029.
-
(2011)
AJNR Am J Neuroradiol
, vol.32
, pp. 2023-2029
-
-
Wintermark, P.1
Hansen, A.2
Gregas, M.C.3
Soul, J.4
Labrecque, M.5
Robertson, R.L.6
Warfield, S.K.7
-
2
-
-
84866149129
-
A quantitative method for correlating observations of decreased apparent diffusion coefficient with elevated cerebral blood perfusion in newborns presenting cerebral ischemic insults
-
Pienaar R, Paldino MJ, Madan N, Krishnamoorthy KS, Alsop DC, Dehaes M, Grant PE., A quantitative method for correlating observations of decreased apparent diffusion coefficient with elevated cerebral blood perfusion in newborns presenting cerebral ischemic insults. Neuroimage 2012; 63: 1510-1518.
-
(2012)
Neuroimage
, vol.63
, pp. 1510-1518
-
-
Pienaar, R.1
Paldino, M.J.2
Madan, N.3
Krishnamoorthy, K.S.4
Alsop, D.C.5
Dehaes, M.6
Grant, P.E.7
-
3
-
-
84896718991
-
Cerebral oxygen metabolism in neonates with congenital heart disease quantified by MRI and optics
-
Jain V, Buckley EM, Licht DJ, et al., Cerebral oxygen metabolism in neonates with congenital heart disease quantified by MRI and optics. J Cereb Blood Flow Metab 2014; 34: 380-388.
-
(2014)
J Cereb Blood Flow Metab
, vol.34
, pp. 380-388
-
-
Jain, V.1
Buckley, E.M.2
Licht, D.J.3
-
4
-
-
84899676408
-
Non-invasive MRI measurements of venous oxygenation, oxygen extraction fraction and oxygen consumption in neonates
-
De Vis JB, Petersen ET, Alderliesten T, Groenendaal F, de Vries LS, van Bel F, Benders MJ, Hendrikse J., Non-invasive MRI measurements of venous oxygenation, oxygen extraction fraction and oxygen consumption in neonates. Neuroimage 2014; 95: 185-192.
-
(2014)
Neuroimage
, vol.95
, pp. 185-192
-
-
De Vis, J.B.1
Petersen, E.T.2
Alderliesten, T.3
Groenendaal, F.4
De Vries, L.S.5
Van Bel, F.6
Benders, M.J.7
Hendrikse, J.8
-
5
-
-
84930038222
-
Cerebral blood flow measurements in infants using look-locker arterial spin labeling
-
Varela M, Petersen ET, Golay X, Hajnal JV,. Cerebral blood flow measurements in infants using look-locker arterial spin labeling. J Magn Reson Imaging 2015; 41: 1591-1600.
-
(2015)
J Magn Reson Imaging
, vol.41
, pp. 1591-1600
-
-
Varela, M.1
Petersen, E.T.2
Golay, X.3
Hajnal, J.V.4
-
6
-
-
84912559803
-
Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy
-
De Vis JB, Hendrikse J, Petersen ET, de Vries LS, van Bel F, Alderliesten T, Negro S, Groenendaal F, Benders MJ., Arterial spin-labelling perfusion MRI and outcome in neonates with hypoxic-ischemic encephalopathy. Eur Radiol 2015; 25: 113-121.
-
(2015)
Eur Radiol
, vol.25
, pp. 113-121
-
-
De Vis, J.B.1
Hendrikse, J.2
Petersen, E.T.3
De Vries, L.S.4
Van Bel, F.5
Alderliesten, T.6
Negro, S.7
Groenendaal, F.8
Benders, M.J.9
-
7
-
-
33747616876
-
Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling
-
Miranda MJ, Olofsson K, Sidaros K., Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling. Pediatr Res 2006; 60: 359-363.
-
(2006)
Pediatr Res
, vol.60
, pp. 359-363
-
-
Miranda, M.J.1
Olofsson, K.2
Sidaros, K.3
-
8
-
-
84883122328
-
Brain perfusion in encephalopathic newborns after therapeutic hypothermia
-
Massaro AN, Bouyssi-Kobar M, Chang T, Vezina LG, du Plessis AJ, Limperopoulos C., Brain perfusion in encephalopathic newborns after therapeutic hypothermia. AJNR Am J Neuroradiol 2013; 34: 1649-1655.
-
(2013)
AJNR Am J Neuroradiol
, vol.34
, pp. 1649-1655
-
-
Massaro, A.N.1
Bouyssi-Kobar, M.2
Chang, T.3
Vezina, L.G.4
Du Plessis, A.J.5
Limperopoulos, C.6
-
9
-
-
84893789827
-
Quantitative assessment of global cerebral metabolic rate of oxygen (CMRO2) in neonates using MRI
-
Liu P, Huang H, Rollins N, Chalak LF, Jeon T, Halovanic C, Lu H., Quantitative assessment of global cerebral metabolic rate of oxygen (CMRO2) in neonates using MRI. NMR Biomed 2014; 27: 332-340.
-
(2014)
NMR Biomed
, vol.27
, pp. 332-340
-
-
Liu, P.1
Huang, H.2
Rollins, N.3
Chalak, L.F.4
Jeon, T.5
Halovanic, C.6
Lu, H.7
-
10
-
-
84919839320
-
Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia
-
Alsop DC, Detre JA, Golay X, et al., Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: a consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. Magn Reson Med 2015; 73: 102-116.
-
(2015)
Magn Reson Med
, vol.73
, pp. 102-116
-
-
Alsop, D.C.1
Detre, J.A.2
Golay, X.3
-
11
-
-
0031883407
-
Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging
-
van Zijl PC, Eleff SM, Ulatowski JA, Oja JM, Ulug AM, Traystman RJ, Kauppinen RA., Quantitative assessment of blood flow, blood volume and blood oxygenation effects in functional magnetic resonance imaging. Nat Med 1998; 4: 159-167.
-
(1998)
Nat Med
, vol.4
, pp. 159-167
-
-
Van Zijl, P.C.1
Eleff, S.M.2
Ulatowski, J.A.3
Oja, J.M.4
Ulug, A.M.5
Traystman, R.J.6
Kauppinen, R.A.7
-
12
-
-
0033386478
-
Determination of oxygen extraction ratios by magnetic resonance imaging
-
Oja JM, Gillen JS, Kauppinen RA, Kraut M, van Zijl PC., Determination of oxygen extraction ratios by magnetic resonance imaging. J Cereb Blood Flow Metab 1999; 19: 1289-1295.
-
(1999)
J Cereb Blood Flow Metab
, vol.19
, pp. 1289-1295
-
-
Oja, J.M.1
Gillen, J.S.2
Kauppinen, R.A.3
Kraut, M.4
Van Zijl, P.C.5
-
13
-
-
0034894866
-
Measurement of tissue oxygen extraction ratios from venous blood T(2): Increased precision and validation of principle
-
Golay X, Silvennoinen MJ, Zhou J, Clingman CS, Kauppinen RA, Pekar JJ, van Zij PC., Measurement of tissue oxygen extraction ratios from venous blood T(2): increased precision and validation of principle. Magn Reson Med 2001; 46: 282-291.
-
(2001)
Magn Reson Med
, vol.46
, pp. 282-291
-
-
Golay, X.1
Silvennoinen, M.J.2
Zhou, J.3
Clingman, C.S.4
Kauppinen, R.A.5
Pekar, J.J.6
Van Zij, P.C.7
-
14
-
-
0035095912
-
Water proton MR properties of human blood at 1.5 Tesla: Magnetic susceptibility, T(1), T(2), T∗(2), and non-Lorentzian signal behavior
-
Spees WM, Yablonskiy DA, Oswood MC, Ackerman JJ., Water proton MR properties of human blood at 1.5 Tesla: magnetic susceptibility, T(1), T(2), T∗(2), and non-Lorentzian signal behavior. Magn Reson Med 2001; 45: 533-542.
-
(2001)
Magn Reson Med
, vol.45
, pp. 533-542
-
-
Spees, W.M.1
Yablonskiy, D.A.2
Oswood, M.C.3
Ackerman, J.J.4
-
15
-
-
0037225632
-
Comparison of the dependence of blood R2 and R2∗ on oxygen saturation at 1.5 and 4.7 Tesla
-
Silvennoinen MJ, Clingman CS, Golay X, Kauppinen RA, van Zijl PC., Comparison of the dependence of blood R2 and R2∗ on oxygen saturation at 1.5 and 4.7 Tesla. Magn Reson Med 2003; 49: 47-60.
-
(2003)
Magn Reson Med
, vol.49
, pp. 47-60
-
-
Silvennoinen, M.J.1
Clingman, C.S.2
Golay, X.3
Kauppinen, R.A.4
Van Zijl, P.C.5
-
16
-
-
4243184848
-
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
-
Lu H, Clingman C, Golay X, van Zijl PC., Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med 2004; 52: 679-682.
-
(2004)
Magn Reson Med
, vol.52
, pp. 679-682
-
-
Lu, H.1
Clingman, C.2
Golay, X.3
Van Zijl, P.C.4
-
17
-
-
60549112411
-
Human whole blood T2 relaxometry at 3 Tesla
-
Chen JJ, Pike GB., Human whole blood T2 relaxometry at 3 Tesla. Magn Reson Med 2009; 61: 249-254.
-
(2009)
Magn Reson Med
, vol.61
, pp. 249-254
-
-
Chen, J.J.1
Pike, G.B.2
-
18
-
-
84355163087
-
Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation
-
Lu H, Xu F, Grgac K, Liu P, Qin Q, van Zijl P., Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation. Magn Reson Med 2012; 67: 42-49.
-
(2012)
Magn Reson Med
, vol.67
, pp. 42-49
-
-
Lu, H.1
Xu, F.2
Grgac, K.3
Liu, P.4
Qin, Q.5
Van Zijl, P.6
-
19
-
-
24144448806
-
T1, T2 relaxation and magnetization transfer in tissue at 3T
-
Stanisz GJ, Odrobina EE, Pun J, Escaravage M, Graham SJ, Bronskill MJ, Henkelman RM., T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005; 54: 507-512.
-
(2005)
Magn Reson Med
, vol.54
, pp. 507-512
-
-
Stanisz, G.J.1
Odrobina, E.E.2
Pun, J.3
Escaravage, M.4
Graham, S.J.5
Bronskill, M.J.6
Henkelman, R.M.7
-
20
-
-
84885298584
-
Hematocrit and oxygenation dependence of blood (1)H(2)O T(1) at 7 Tesla
-
Grgac K, van Zijl PC, Qin Q., Hematocrit and oxygenation dependence of blood (1)H(2)O T(1) at 7 Tesla. Magn Reson Med 2013; 70: 1153-1159.
-
(2013)
Magn Reson Med
, vol.70
, pp. 1153-1159
-
-
Grgac, K.1
Van Zijl, P.C.2
Qin, Q.3
-
21
-
-
84900802854
-
Dependence of blood T(2) on oxygenation at 7 T: In vitro calibration and in vivo application
-
Krishnamurthy LC, Liu P, Xu F, Uh J, Dimitrov I, Lu H., Dependence of blood T(2) on oxygenation at 7 T: in vitro calibration and in vivo application. Magn Reson Med 2014; 71: 2035-2042.
-
(2014)
Magn Reson Med
, vol.71
, pp. 2035-2042
-
-
Krishnamurthy, L.C.1
Liu, P.2
Xu, F.3
Uh, J.4
Dimitrov, I.5
Lu, H.6
-
22
-
-
77957292924
-
Dependence of blood R2 relaxivity on CPMG echo-spacing at 2.35 and 7 T
-
Gardener AG, Francis ST, Prior M, Peters A, Gowland PA., Dependence of blood R2 relaxivity on CPMG echo-spacing at 2.35 and 7 T. Magn Reson Med 2010; 64: 967-974.
-
(2010)
Magn Reson Med
, vol.64
, pp. 967-974
-
-
Gardener, A.G.1
Francis, S.T.2
Prior, M.3
Peters, A.4
Gowland, P.A.5
-
23
-
-
0345067032
-
Measurement of fetal hemoglobin in newborn infants; Correlation with gestational age and intrauterine hypoxia
-
Cook CD, Brodie HR, Allen DW., Measurement of fetal hemoglobin in newborn infants; correlation with gestational age and intrauterine hypoxia. Pediatrics 1957; 20: 272-278.
-
(1957)
Pediatrics
, vol.20
, pp. 272-278
-
-
Cook, C.D.1
Brodie, H.R.2
Allen, D.W.3
-
24
-
-
0017181512
-
Changing blood picture in sickle-cell anaemia from shortly after birth to adolescence
-
Davis LR., Changing blood picture in sickle-cell anaemia from shortly after birth to adolescence. J Clin Pathol 1976; 29: 898-901.
-
(1976)
J Clin Pathol
, vol.29
, pp. 898-901
-
-
Davis, L.R.1
-
25
-
-
33748469898
-
Effect of delayed sampling on umbilical cord arterial and venous lactate and blood gases in clamped and unclamped vessels
-
Armstrong L, Stenson B., Effect of delayed sampling on umbilical cord arterial and venous lactate and blood gases in clamped and unclamped vessels. Arch Dis Child Fetal Neonatal Ed 2006; 91: F342-F345.
-
(2006)
Arch Dis Child Fetal Neonatal Ed
, vol.91
, pp. F342-F345
-
-
Armstrong, L.1
Stenson, B.2
-
26
-
-
49049091751
-
Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI
-
Lu H, Ge Y., Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI. Magn Reson Med 2008; 60: 357-363.
-
(2008)
Magn Reson Med
, vol.60
, pp. 357-363
-
-
Lu, H.1
Ge, Y.2
-
27
-
-
58249136113
-
Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: Data from a multihospital health care system
-
Jopling J, Henry E, Wiedmeier SE, Christensen RD., Reference ranges for hematocrit and blood hemoglobin concentration during the neonatal period: data from a multihospital health care system. Pediatrics 2009; 123: e333-e337.
-
(2009)
Pediatrics
, vol.123
, pp. e333-e337
-
-
Jopling, J.1
Henry, E.2
Wiedmeier, S.E.3
Christensen, R.D.4
-
28
-
-
0026320313
-
Fast selective black blood MR imaging
-
Edelman RR, Chien D, Kim D., Fast selective black blood MR imaging. Radiology 1991; 181: 655-660.
-
(1991)
Radiology
, vol.181
, pp. 655-660
-
-
Edelman, R.R.1
Chien, D.2
Kim, D.3
-
29
-
-
0041591021
-
Functional magnetic resonance imaging based on changes in vascular space occupancy
-
Lu H, Golay X, Pekar JJ, Van Zijl PC., Functional magnetic resonance imaging based on changes in vascular space occupancy. Magn Reson Med 2003; 50: 263-274.
-
(2003)
Magn Reson Med
, vol.50
, pp. 263-274
-
-
Lu, H.1
Golay, X.2
Pekar, J.J.3
Van Zijl, P.C.4
-
30
-
-
84961398839
-
Simultaneous OEF and Haematocrit assessment using T2 Prepared Blood Relaxation Imaging with Inversion Recovery
-
Melbourn, Australia, Abstract 472
-
Petersen ET, De Vis JB, Alderliesten T, Kersbergen KJ, Benders MJ, Hendrikse J, van den Berg CAT,. Simultaneous OEF and Haematocrit assessment using T2 Prepared Blood Relaxation Imaging with Inversion Recovery. In Proceedings of the 20th Annual Meeting of ISMRM, Melbourn, Australia, 2012. Abstract 472.
-
(2012)
Proceedings of the 20th Annual Meeting of ISMRM
-
-
Petersen, E.T.1
De Vis, J.B.2
Alderliesten, T.3
Kersbergen, K.J.4
Benders, M.J.5
Hendrikse, J.6
Van Den Berg, C.A.T.7
-
31
-
-
84874377980
-
Test-retest reproducibility of a rapid method to measure brain oxygen metabolism
-
Liu P, Xu F, Lu H., Test-retest reproducibility of a rapid method to measure brain oxygen metabolism. Magn Reson Med 2013; 69: 675-681.
-
(2013)
Magn Reson Med
, vol.69
, pp. 675-681
-
-
Liu, P.1
Xu, F.2
Lu, H.3
-
32
-
-
69549120342
-
Cerebral blood flow and metabolism in the developing fetus
-
du Plessis AJ., Cerebral blood flow and metabolism in the developing fetus. Clin Perinatol 2009; 36: 531-548.
-
(2009)
Clin Perinatol
, vol.36
, pp. 531-548
-
-
Du Plessis, A.J.1
-
33
-
-
84894352084
-
Biomarkers for severity of neonatal hypoxic-ischemic encephalopathy and outcomes in newborns receiving hypothermia therapy
-
e461
-
Chalak LF, Sanchez PJ, Adams-Huet B, Laptook AR, Heyne RJ, Rosenfeld CR., Biomarkers for severity of neonatal hypoxic-ischemic encephalopathy and outcomes in newborns receiving hypothermia therapy. J Pediatr 2014; 164: 468-474 e461.
-
(2014)
J Pediatr
, vol.164
, pp. 468-474
-
-
Chalak, L.F.1
Sanchez, P.J.2
Adams-Huet, B.3
Laptook, A.R.4
Heyne, R.J.5
Rosenfeld, C.R.6
-
34
-
-
84922404167
-
Non-invasive assessment of neonatal brain oxygen metabolism: A review of newly available techniques
-
Liu P, Chalak LF, Lu H., Non-invasive assessment of neonatal brain oxygen metabolism: a review of newly available techniques. Early Hum Dev 2014; 90: 695-701.
-
(2014)
Early Hum Dev
, vol.90
, pp. 695-701
-
-
Liu, P.1
Chalak, L.F.2
Lu, H.3
-
35
-
-
78851469408
-
A method for rapid in vivo measurement of blood T1
-
Varela M, Hajnal JV, Petersen ET, Golay X, Merchant N, Larkman DJ., A method for rapid in vivo measurement of blood T1. NMR Biomed 2011; 24: 80-88.
-
(2011)
NMR Biomed
, vol.24
, pp. 80-88
-
-
Varela, M.1
Hajnal, J.V.2
Petersen, E.T.3
Golay, X.4
Merchant, N.5
Larkman, D.J.6
-
36
-
-
77957304423
-
In vivo venous blood T1 measurement using inversion recovery true-FISP in children and adults
-
Wu WC, Jain V, Li C, Giannetta M, Hurt H, Wehrli FW, Wang DJ., In vivo venous blood T1 measurement using inversion recovery true-FISP in children and adults. Magn Reson Med 2010; 64: 1140-1147.
-
(2010)
Magn Reson Med
, vol.64
, pp. 1140-1147
-
-
Wu, W.C.1
Jain, V.2
Li, C.3
Giannetta, M.4
Hurt, H.5
Wehrli, F.W.6
Wang, D.J.7
-
37
-
-
0020679339
-
Geometry of neonatal and adult red blood cells
-
Linderkamp O, Wu PY, Meiselman HJ., Geometry of neonatal and adult red blood cells. Pediatr Res 1983; 17: 250-253.
-
(1983)
Pediatr Res
, vol.17
, pp. 250-253
-
-
Linderkamp, O.1
Wu, P.Y.2
Meiselman, H.J.3
-
38
-
-
84885316008
-
In vivo blood T(1) measurements at 1.5 T, 3 T, and 7 T
-
Zhang X, Petersen ET, Ghariq E, De Vis JB, Webb AG, Teeuwisse WM, Hendrikse J, van Osch MJ., In vivo blood T(1) measurements at 1.5 T, 3 T, and 7 T. Magn Reson Med 2013; 70: 1082-1086.
-
(2013)
Magn Reson Med
, vol.70
, pp. 1082-1086
-
-
Zhang, X.1
Petersen, E.T.2
Ghariq, E.3
De Vis, J.B.4
Webb, A.G.5
Teeuwisse, W.M.6
Hendrikse, J.7
Van Osch, M.J.8
|