메뉴 건너뛰기




Volumn 8, Issue 5, 2015, Pages 725-727

Filtering the truth behind cerebral embolization during transcatheter aortic valve replacement

Author keywords

aortic stenosis; cerebral emboli; embolic protection; transcatheter aortic valve replacement

Indexed keywords

ARTIFICIAL EMBOLISM; BRAIN EMBOLISM; COMORBIDITY; DOPPLER ECHOGRAPHY; EMBOLIC PROTECTION DEVICE; HEART ATRIUM ARRHYTHMIA; HIGH RISK PATIENT; HUMAN; NOTE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; TRANSCATHETER AORTIC VALVE IMPLANTATION; ADVERSE EFFECTS; AORTA VALVE; FEMALE; FOREIGN-BODY MIGRATION; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; INTRACRANIAL EMBOLISM; MALE; THROMBOSIS;

EID: 84929160055     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2015.01.017     Document Type: Editorial
Times cited : (6)

References (17)
  • 1
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • C.R. Smith, M.B. Leon, and M.J. Mack Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 2
    • 84899811656 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement with a self-expanding prosthesis
    • D.H. Adams, J.J. Popma, and M.J. Reardon Transcatheter aortic-valve replacement with a self-expanding prosthesis N Engl J Med 370 2014 1790 1798
    • (2014) N Engl J Med , vol.370 , pp. 1790-1798
    • Adams, D.H.1    Popma, J.J.2    Reardon, M.J.3
  • 3
    • 84860467838 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation and cerebrovascular events: The current state of the art
    • B.G. Hynes, and J. Rodes-Cabau Transcatheter aortic valve implantation and cerebrovascular events: the current state of the art Ann N Y Acad Sci 1254 2012 151 163
    • (2012) Ann N y Acad Sci , vol.1254 , pp. 151-163
    • Hynes, B.G.1    Rodes-Cabau, J.2
  • 4
    • 84872871894 scopus 로고    scopus 로고
    • Trends in outcome after transfemoral transcatheter aortic valve implantation
    • N.M. Van Mieghem, A. Chieffo, and N. Dumonteil Trends in outcome after transfemoral transcatheter aortic valve implantation Am Heart J 165 2013 183 192
    • (2013) Am Heart J , vol.165 , pp. 183-192
    • Van Mieghem, N.M.1    Chieffo, A.2    Dumonteil, N.3
  • 5
    • 84922540805 scopus 로고    scopus 로고
    • Outcomes after transfemoral transcatheter aortic valve replacement: A comparison of the randomized PARTNER (Placement of AoRTic TraNscathetER Valves) trial with the NRCA (Nonrandomized Continued Access) registry
    • W.F. Fearon, S. Kodali, and D. Doshi Outcomes after transfemoral transcatheter aortic valve replacement: a comparison of the randomized PARTNER (Placement of AoRTic TraNscathetER Valves) trial with the NRCA (Nonrandomized Continued Access) registry J Am Coll Cardiol Intv 7 2014 1245 1251
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 1245-1251
    • Fearon, W.F.1    Kodali, S.2    Doshi, D.3
  • 6
    • 84865848038 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study
    • P. Kahlert, F. Al-Rashid, and P. Dottger Cerebral embolization during transcatheter aortic valve implantation: a transcranial Doppler study Circulation 126 2012 1245 1255
    • (2012) Circulation , vol.126 , pp. 1245-1255
    • Kahlert, P.1    Al-Rashid, F.2    Dottger, P.3
  • 7
    • 84871330882 scopus 로고    scopus 로고
    • Timing, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation
    • L. Nombela-Franco, J.G. Webb, and P.P. de Jaegere Timing, predictive factors, and prognostic value of cerebrovascular events in a large cohort of patients undergoing transcatheter aortic valve implantation Circulation 126 2012 3041 3053
    • (2012) Circulation , vol.126 , pp. 3041-3053
    • Nombela-Franco, L.1    Webb, J.G.2    De Jaegere, P.P.3
  • 8
    • 84904970354 scopus 로고    scopus 로고
    • Outcomes with post-dilation following transcatheter aortic valve replacement: The PARTNER i trial (placement of aortic transcatheter valve)
    • R.T. Hahn, P. Pibarot, and J. Webb Outcomes with post-dilation following transcatheter aortic valve replacement: the PARTNER I trial (placement of aortic transcatheter valve) J Am Coll Cardiol Intv 7 2014 781 789
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 781-789
    • Hahn, R.T.1    Pibarot, P.2    Webb, J.3
  • 9
    • 84908169883 scopus 로고    scopus 로고
    • Cerebrovascular events post-transcatheter aortic valve replacement in a large cohort of patients: A FRANCE-2 registry substudy
    • D. Tchetche, B. Farah, and L. Misuraca Cerebrovascular events post-transcatheter aortic valve replacement in a large cohort of patients: a FRANCE-2 registry substudy J Am Coll Cardiol Intv 7 2014 1138 1145
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 1138-1145
    • Tchetche, D.1    Farah, B.2    Misuraca, L.3
  • 10
    • 84929177144 scopus 로고    scopus 로고
    • Incidence and predictors of debris embolizing to the brain during transcatheter aortic valve implantation
    • N.M. Van Mieghem, N. El Faquir, and Z. Rahhab Incidence and predictors of debris embolizing to the brain during transcatheter aortic valve implantation J Am Coll Cardiol Intv 8 2015 718 724
    • (2015) J Am Coll Cardiol Intv , vol.8 , pp. 718-724
    • Van Mieghem, N.M.1    El Faquir, N.2    Rahhab, Z.3
  • 11
    • 84878544469 scopus 로고    scopus 로고
    • Histopathology of embolic debris captured during transcatheter aortic valve replacement
    • N.M. Van Mieghem, M.E. Schipper, and E. Ladich Histopathology of embolic debris captured during transcatheter aortic valve replacement Circulation 127 2013 2194 2201
    • (2013) Circulation , vol.127 , pp. 2194-2201
    • Van Mieghem, N.M.1    Schipper, M.E.2    Ladich, E.3
  • 12
    • 84880280776 scopus 로고    scopus 로고
    • Quantity, particle size, and histologic composition of embolic debris collected in a distal protection filter after carotid angioplasty and stenting: Correlation with patient characteristics, timing of carotid artery stenting, and procedural details
    • J.H. van Laanen, J.M. Hendriks, H.J. Verhagen, and H.M. van Beusekom Quantity, particle size, and histologic composition of embolic debris collected in a distal protection filter after carotid angioplasty and stenting: correlation with patient characteristics, timing of carotid artery stenting, and procedural details J Thorac Cardiovasc Surg 146 2013 492 495
    • (2013) J Thorac Cardiovasc Surg , vol.146 , pp. 492-495
    • Van Laanen, J.H.1    Hendriks, J.M.2    Verhagen, H.J.3    Van Beusekom, H.M.4
  • 13
    • 84925137432 scopus 로고    scopus 로고
    • Pathology of embolic debris in carotid artery stenting
    • H. Matsukawa, M. Fujii, and A. Uemura Pathology of embolic debris in carotid artery stenting Acta Neurol Scand 131 2015 197 202
    • (2015) Acta Neurol Scand , vol.131 , pp. 197-202
    • Matsukawa, H.1    Fujii, M.2    Uemura, A.3
  • 14
    • 84901048870 scopus 로고    scopus 로고
    • Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: A meta-analysis and systematic review of literature
    • G. Athappan, R.D. Gajulapalli, and P. Sengodan Influence of transcatheter aortic valve replacement strategy and valve design on stroke after transcatheter aortic valve replacement: a meta-analysis and systematic review of literature J Am Coll Cardiol 63 2014 2101 2110
    • (2014) J Am Coll Cardiol , vol.63 , pp. 2101-2110
    • Athappan, G.1    Gajulapalli, R.D.2    Sengodan, P.3
  • 15
    • 84908164006 scopus 로고    scopus 로고
    • Feasibility and exploratory efficacy evaluation of the Embrella Embolic Deflector system for the prevention of cerebral emboli in patients undergoing transcatheter aortic valve replacement: The PROTAVI-C pilot study
    • J. Rodes-Cabau, P. Kahlert, and F.J. Neumann Feasibility and exploratory efficacy evaluation of the Embrella Embolic Deflector system for the prevention of cerebral emboli in patients undergoing transcatheter aortic valve replacement: the PROTAVI-C pilot study J Am Coll Cardiol Intv 7 2014 1146 1155
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 1146-1155
    • Rodes-Cabau, J.1    Kahlert, P.2    Neumann, F.J.3
  • 16
    • 85034085376 scopus 로고    scopus 로고
    • First report of the DEFLECT i trial. A prospective, single arm feasibility study to evaluate the safety and performance of the Keystone Heart Triguard embolic deflection device in patients undergoing transcatheter aortic valve replacement
    • May 21-24 Paris, France
    • Mullen M. First report of the DEFLECT I trial. A prospective, single arm feasibility study to evaluate the safety and performance of the Keystone Heart Triguard embolic deflection device in patients undergoing transcatheter aortic valve replacement. Paper presented at: EuroPCR; May 21-24, 2013; Paris, France.
    • (2013) EuroPCR
    • Mullen, M.1
  • 17
    • 85018138319 scopus 로고    scopus 로고
    • The CLEAN-TAVI trial (Late-Breaking Clinical Trials)
    • September 13-17 Washington, DC
    • Linke A. The CLEAN-TAVI trial (Late-Breaking Clinical Trials). Presented at Transcatheter Cardiovascular Therapeutics; September 13-17, 2014; Washington, DC.
    • (2014) Transcatheter Cardiovascular Therapeutics
    • Linke, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.