메뉴 건너뛰기




Volumn 446, Issue , 2015, Pages 128-131

A clinical and laboratory approach used to elucidate discordant results of high-sensitivity troponin T and troponin I

Author keywords

Heterophile antibodies; Immunoassay interference; Troponin

Indexed keywords

CREATINE KINASE MB; HETEROPHILE ANTIBODY; HIGH SENSITIVITY TROPONIN T; MYOGLOBIN; TROPONIN I; TROPONIN T; UNCLASSIFIED DRUG; IMMUNOGLOBULIN M; MONOCLONAL ANTIBODY;

EID: 84928716760     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2015.03.046     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 84896739990 scopus 로고    scopus 로고
    • Analytically false or true positive elevations of high sensitivity cardiac troponin: a systematic approach
    • Vafaie M., Biener M., Mueller M., et al. Analytically false or true positive elevations of high sensitivity cardiac troponin: a systematic approach. Heart 2014, 100:508-514.
    • (2014) Heart , vol.100 , pp. 508-514
    • Vafaie, M.1    Biener, M.2    Mueller, M.3
  • 2
    • 33748932343 scopus 로고    scopus 로고
    • False positive cardiac troponin results in patients without acute myocardial infarction
    • Lum G., Solarz D.E., Farney L. False positive cardiac troponin results in patients without acute myocardial infarction. Lab Med 2006, 37:546-550.
    • (2006) Lab Med , vol.37 , pp. 546-550
    • Lum, G.1    Solarz, D.E.2    Farney, L.3
  • 3
    • 84872486936 scopus 로고    scopus 로고
    • A case of false positive troponin elevation: role of the biological laboratory
    • Dupont J., Fromonot J., Franceschi F., et al. A case of false positive troponin elevation: role of the biological laboratory. Int J Cardiol 2013, 162:e66-e67.
    • (2013) Int J Cardiol , vol.162 , pp. e66-e67
    • Dupont, J.1    Fromonot, J.2    Franceschi, F.3
  • 5
    • 52949085535 scopus 로고    scopus 로고
    • Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department
    • Pernet P., Bénéteau-Burnat B., Hermand C., Vaubourdolle M. Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department. Am J Emerg Med 2008, 26(969):e1-e2.
    • (2008) Am J Emerg Med , vol.26 , Issue.969 , pp. e1-e2
    • Pernet, P.1    Bénéteau-Burnat, B.2    Hermand, C.3    Vaubourdolle, M.4
  • 6
    • 84884789108 scopus 로고    scopus 로고
    • Interference from heterophilic antibodies in troponin testing. Case report and systematic review of the literature
    • Lippi G., Aloe R., Meschi T., Borghi L., Cervellin G. Interference from heterophilic antibodies in troponin testing. Case report and systematic review of the literature. Clin Chim Acta 2013, 426:79-84.
    • (2013) Clin Chim Acta , vol.426 , pp. 79-84
    • Lippi, G.1    Aloe, R.2    Meschi, T.3    Borghi, L.4    Cervellin, G.5
  • 8
    • 84885439463 scopus 로고    scopus 로고
    • Endogenous antibody interferences in immunoassays
    • Emerson J.F., Lai K.K.Y. Endogenous antibody interferences in immunoassays. Lab Med 2013, 44:69-73.
    • (2013) Lab Med , vol.44 , pp. 69-73
    • Emerson, J.F.1    Lai, K.K.Y.2
  • 9
    • 84855176252 scopus 로고    scopus 로고
    • Analytical error and interference in immunoassay: minimizing risk
    • Sturgeon C.M., Viljoen A. Analytical error and interference in immunoassay: minimizing risk. Ann Clin Biochem 2011, 48:418-432.
    • (2011) Ann Clin Biochem , vol.48 , pp. 418-432
    • Sturgeon, C.M.1    Viljoen, A.2
  • 10
    • 0037934622 scopus 로고    scopus 로고
    • Screening for interference in immunoassays
    • Emerson J.F., Ngo G., Emerson S.S. Screening for interference in immunoassays. Clin Chem 2003, 49:1163-1169.
    • (2003) Clin Chem , vol.49 , pp. 1163-1169
    • Emerson, J.F.1    Ngo, G.2    Emerson, S.S.3
  • 11
    • 25144458776 scopus 로고    scopus 로고
    • Interferences in immunoassay
    • Tate J., Ward G. Interferences in immunoassay. Clin Biochem Rev 2004, 25:105-120.
    • (2004) Clin Biochem Rev , vol.25 , pp. 105-120
    • Tate, J.1    Ward, G.2
  • 12
    • 84856068587 scopus 로고    scopus 로고
    • Analytical characteristics of high-sensitivity cardiac troponin assays
    • Apple F.S., Collinson P.O. Analytical characteristics of high-sensitivity cardiac troponin assays. Clin Chem 2012, 58:54-61.
    • (2012) Clin Chem , vol.58 , pp. 54-61
    • Apple, F.S.1    Collinson, P.O.2
  • 13
    • 84884736438 scopus 로고    scopus 로고
    • Fluctuation of spuriously elevated troponin I: a case report
    • Ghali S., Lewis K., Kazan V., et al. Fluctuation of spuriously elevated troponin I: a case report. Case Rep Crit Care 2012, 2012:585879. 10.1155/2012/585879.
    • (2012) Case Rep Crit Care , vol.2012 , pp. 585879
    • Ghali, S.1    Lewis, K.2    Kazan, V.3
  • 14
    • 84856076075 scopus 로고    scopus 로고
    • Concordance, variance, and outliers in 4 contemporary cardiac troponin assays: implications for harmonization
    • Ungerer J.P., Marquart L., O'Rourke P.K., Wilgen U., Pretorius C.J. Concordance, variance, and outliers in 4 contemporary cardiac troponin assays: implications for harmonization. Clin Chem 2012, 58:274-283.
    • (2012) Clin Chem , vol.58 , pp. 274-283
    • Ungerer, J.P.1    Marquart, L.2    O'Rourke, P.K.3    Wilgen, U.4    Pretorius, C.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.