메뉴 건너뛰기




Volumn 8, Issue 1, 2015, Pages

A reach-out system for video microscopy analysis of ciliary motions aiding PCD diagnosis

Author keywords

Cilia; Microscopy; Portability; Video

Indexed keywords

NITRIC OXIDE;

EID: 84928715063     PISSN: None     EISSN: 17560500     Source Type: Journal    
DOI: 10.1186/s13104-015-0999-x     Document Type: Article
Times cited : (12)

References (15)
  • 4
    • 0035694436 scopus 로고    scopus 로고
    • The effects of coronavirus on human nasal ciliated respiratory epithelium
    • 1:STN:280:DC%2BD38%2FpvVyisw%3D%3D 11829103
    • Chilvers MA, McKean M, Rutman A, Myint BS, Silverman M, O'Callaghan C. The effects of coronavirus on human nasal ciliated respiratory epithelium. Eur Respir J. 2001;18:965-70.
    • (2001) Eur Respir J , vol.18 , pp. 965-970
    • Chilvers, M.A.1    McKean, M.2    Rutman, A.3    Myint, B.S.4    Silverman, M.5    O'Callaghan, C.6
  • 7
    • 0041657684 scopus 로고    scopus 로고
    • All-digital image capture and whole-field analysis of ciliary beat frequency
    • 1:STN:280:DC%2BD3szos12jtA%3D%3D 12887704
    • Sisson JH, Stoner JA, Ammons BA, Wyatt TA. All-digital image capture and whole-field analysis of ciliary beat frequency. J Microsc. 2003;211:103-11.
    • (2003) J Microsc , vol.211 , pp. 103-111
    • Sisson, J.H.1    Stoner, J.A.2    Ammons, B.A.3    Wyatt, T.A.4
  • 9
    • 84916203838 scopus 로고    scopus 로고
    • Diagnosis of primary ciliary dyskinesia: Searching for a gold standard
    • Lucas JS, Leigh MW. Diagnosis of primary ciliary dyskinesia: searching for a gold standard. Eur Respir J. 2014;44:6.
    • (2014) Eur Respir J , vol.44 , pp. 6
    • Lucas, J.S.1    Leigh, M.W.2
  • 10
    • 84886431107 scopus 로고    scopus 로고
    • Standardizing nasal nitric oxide measurement as a test for primary ciliary dyskinesia
    • 3960971 1:CAS:528:DC%2BC2cXhtlekt73P 24024753
    • Leigh MW, Hazucha MJ, Chawla KK, Baker BR, Shapiro AJ, Brown DE, et al. Standardizing nasal nitric oxide measurement as a test for primary ciliary dyskinesia. Ann Am Thorac Soc. 2013;10(6):574-81.
    • (2013) Ann Am Thorac Soc , vol.10 , Issue.6 , pp. 574-581
    • Leigh, M.W.1    Hazucha, M.J.2    Chawla, K.K.3    Baker, B.R.4    Shapiro, A.J.5    Brown, D.E.6
  • 13
    • 77954748919 scopus 로고    scopus 로고
    • Lung function in patients with primary ciliary dyskinesia: A cross-sectional and 3-decade longitudinal study
    • 20167855
    • Marthin JK, Petersen N, Skovgaard LT, Nielsen KG. Lung function in patients with primary ciliary dyskinesia: a cross-sectional and 3-decade longitudinal study. Am J Respir Crit Care Med. 2010;181(11):1262-8.
    • (2010) Am J Respir Crit Care Med , vol.181 , Issue.11 , pp. 1262-1268
    • Marthin, J.K.1    Petersen, N.2    Skovgaard, L.T.3    Nielsen, K.G.4
  • 14
    • 84864826506 scopus 로고    scopus 로고
    • Ciliary beat pattern analysis below 37°C may increase risk of primary ciliary dyskinesia misdiagnosis
    • 22871779
    • Jackson CL, Goggin PM, Lucas JS. Ciliary beat pattern analysis below 37°C may increase risk of primary ciliary dyskinesia misdiagnosis. Chest. 2012;142(2):543-4.
    • (2012) Chest , vol.142 , Issue.2 , pp. 543-544
    • Jackson, C.L.1    Goggin, P.M.2    Lucas, J.S.3
  • 15
    • 79960406244 scopus 로고    scopus 로고
    • Cooling of cilia allows functional analysis of the beat pattern for diagnostic testing
    • 21193531
    • Smith CM, Hirst RA, Bankart MJ, Jones DW, Easton AJ, Andrew PW, et al. Cooling of cilia allows functional analysis of the beat pattern for diagnostic testing. Chest. 2011;140(1):186-90.
    • (2011) Chest , vol.140 , Issue.1 , pp. 186-190
    • Smith, C.M.1    Hirst, R.A.2    Bankart, M.J.3    Jones, D.W.4    Easton, A.J.5    Andrew, P.W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.