메뉴 건너뛰기




Volumn 26, Issue 5, 2015, Pages 734-740

Design and performance evaluation of a linear ion trap mass analyzer featuring half round rod electrodes

Author keywords

Linear ion trap; Mass analyzer; Mass resolution; Radial ejection; Round rod electrode

Indexed keywords

ELECTRODES; MASS SPECTROMETRY; STAINLESS STEEL;

EID: 84928578907     PISSN: 10440305     EISSN: 18791123     Source Type: Journal    
DOI: 10.1007/s13361-015-1085-2     Document Type: Article
Times cited : (24)

References (34)
  • 1
    • 0030999705 scopus 로고    scopus 로고
    • An introduction to quadrupole ion trap mass spectrometry
    • 1:CAS:528:DyaK2sXivVKjtLs%3D
    • March, R.E.: An introduction to quadrupole ion trap mass spectrometry. J. Mass Spectrom. 32, 351-369 (1997)
    • (1997) J. Mass Spectrom. , vol.32 , pp. 351-369
    • March, R.E.1
  • 2
    • 0031765003 scopus 로고    scopus 로고
    • Quadrupole ion trap mass spectrometry: theory, simulation, recent developments, and applications
    • 1:CAS:528:DyaK1cXmvFOku7o%3D
    • March, R.E.: Quadrupole ion trap mass spectrometry: theory, simulation, recent developments, and applications. Rapid Commun. Mass Spectrom. 12, 1543-1554 (1998)
    • (1998) Rapid Commun. Mass Spectrom. , vol.12 , pp. 1543-1554
    • March, R.E.1
  • 3
    • 70449094032 scopus 로고    scopus 로고
    • Quadrupole ion traps
    • 1:CAS:528:DC%2BD1MXhsFaqtbfF
    • March, R.E.: Quadrupole ion traps. Mass Spectrom. Rev. 28, 961-989 (2009)
    • (2009) Mass Spectrom. Rev. , vol.28 , pp. 961-989
    • March, R.E.1
  • 4
    • 84855405567 scopus 로고    scopus 로고
    • Quantification of human uridine-diphosphate glucuronosyl transferase 1A isoforms in liver, intestine, and kidney using nanobore liquid chromatography-tandem mass spectrometry
    • 1:CAS:528:DC%2BC3MXhsVSqsb3F
    • Harbourt, D.E., Fallon, J.K., Ito, S., Baba, T., Ritter, J.K., Glish, G.L., Smith, P.C.: Quantification of human uridine-diphosphate glucuronosyl transferase 1A isoforms in liver, intestine, and kidney using nanobore liquid chromatography-tandem mass spectrometry. Anal. Chem. 84, 98-105 (2012)
    • (2012) Anal. Chem. , vol.84 , pp. 98-105
    • Harbourt, D.E.1    Fallon, J.K.2    Ito, S.3    Baba, T.4    Ritter, J.K.5    Glish, G.L.6    Smith, P.C.7
  • 5
    • 84856699962 scopus 로고    scopus 로고
    • Linear ion trap msn of enzymatically synthesized 13C-labeled fructans revealing differentiating fragmentation patterns of beta (1-2) and beta (1-6) fructans and providing a tool for oligosaccharide identification in complex mixtures
    • 1:CAS:528:DC%2BC3MXhsFOhtrbJ
    • Harrison, S., Xue, H., Lane, G., Villas-Boas, S., Rasmussen, S.: Linear ion trap msn of enzymatically synthesized 13C-labeled fructans revealing differentiating fragmentation patterns of beta (1-2) and beta (1-6) fructans and providing a tool for oligosaccharide identification in complex mixtures. Anal. Chem. 84, 1540-1548 (2012)
    • (2012) Anal. Chem. , vol.84 , pp. 1540-1548
    • Harrison, S.1    Xue, H.2    Lane, G.3    Villas-Boas, S.4    Rasmussen, S.5
  • 6
    • 79954616758 scopus 로고    scopus 로고
    • Ultrasensitive characterization of site-specific glycosylation of affinity-purified haptoglobin from lung cancer patient plasma using 10 mu m i.d. porous layer open tubular liquid chromatography-linear ion trap collision-induced dissociation/electron transfer dissociation mass spectrometry
    • 1:CAS:528:DC%2BC3MXit1Wjsbk%3D
    • Wang, D., Hincapie, M., Rejtar, T., Karger, B.L.: Ultrasensitive characterization of site-specific glycosylation of affinity-purified haptoglobin from lung cancer patient plasma using 10 mu m i.d. porous layer open tubular liquid chromatography-linear ion trap collision-induced dissociation/electron transfer dissociation mass spectrometry. Anal. Chem. 83, 2029-2037 (2011)
    • (2011) Anal. Chem. , vol.83 , pp. 2029-2037
    • Wang, D.1    Hincapie, M.2    Rejtar, T.3    Karger, B.L.4
  • 7
    • 84856702449 scopus 로고    scopus 로고
    • Evaluation of front-end higher energy collision-induced dissociation on a benchtop dual-pressure linear ion trap mass spectrometer for shotgun proteomics
    • 1:CAS:528:DC%2BC3MXhs1GlsL3K
    • Bereman, M.S., Canterbury, J.D., Egertson, J.D., Horner, J., Remes, P.M., Schwartz, J., Zabrouskoy, V., MacCoss, M.J.: Evaluation of front-end higher energy collision-induced dissociation on a benchtop dual-pressure linear ion trap mass spectrometer for shotgun proteomics. Anal. Chem. 84, 1533-1539 (2012)
    • (2012) Anal. Chem. , vol.84 , pp. 1533-1539
    • Bereman, M.S.1    Canterbury, J.D.2    Egertson, J.D.3    Horner, J.4    Remes, P.M.5    Schwartz, J.6    Zabrouskoy, V.7    MacCoss, M.J.8
  • 8
    • 0001325675 scopus 로고    scopus 로고
    • A two-dimensional quadrupole ion trap mass spectrometer
    • 1:CAS:528:DC%2BD38Xjsl2lurk%3D
    • Schwartz, J.C., Senko, M.W., Syka, J.E.P.: A two-dimensional quadrupole ion trap mass spectrometer. J. Am. Soc. Mass Spectrom. 13, 659-669 (2002)
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 659-669
    • Schwartz, J.C.1    Senko, M.W.2    Syka, J.E.P.3
  • 9
    • 0036199431 scopus 로고    scopus 로고
    • A new linear ion trap mass spectrometer
    • 1:CAS:528:DC%2BD38Xit1Gjs7c%3D
    • Hager, J.W.: A new linear ion trap mass spectrometer. Rapid Commun. Mass Spectrom. 16, 512-526 (2002)
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 512-526
    • Hager, J.W.1
  • 10
    • 0141450231 scopus 로고    scopus 로고
    • Mass selective axial ion ejection from a linear quadrupole ion trap
    • 1:CAS:528:DC%2BD3sXnvFahurs%3D
    • Londry, F.A., Hager, J.W.: Mass selective axial ion ejection from a linear quadrupole ion trap. J. Am. Soc. Mass Spectrom. 14, 1130-1147 (2003)
    • (2003) J. Am. Soc. Mass Spectrom. , vol.14 , pp. 1130-1147
    • Londry, F.A.1    Hager, J.W.2
  • 11
    • 32444433051 scopus 로고    scopus 로고
    • Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source
    • 1:CAS:528:DC%2BD2MXhtlClsbrM
    • Song, Q.Y., Kothari, S., Senko, M.A., Schwartz, J.C., Amy, J.W., Stafford, G.C., Cooks, R.G., Ouyang, Z.: Rectilinear ion trap mass spectrometer with atmospheric pressure interface and electrospray ionization source. Anal. Chem. 78, 718-725 (2006)
    • (2006) Anal. Chem. , vol.78 , pp. 718-725
    • Song, Q.Y.1    Kothari, S.2    Senko, M.A.3    Schwartz, J.C.4    Amy, J.W.5    Stafford, G.C.6    Cooks, R.G.7    Ouyang, Z.8
  • 12
    • 4043060624 scopus 로고    scopus 로고
    • Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer
    • 1:CAS:528:DC%2BD2cXls1Krtbg%3D
    • Ouyang, Z., Wu, G.X., Song, Y.S., Li, H.Y., Plass, W.R., Cooks, R.G.: Rectilinear ion trap: concepts, calculations, and analytical performance of a new mass analyzer. Anal. Chem. 76, 4595-4605 (2004)
    • (2004) Anal. Chem. , vol.76 , pp. 4595-4605
    • Ouyang, Z.1    Wu, G.X.2    Song, Y.S.3    Li, H.Y.4    Plass, W.R.5    Cooks, R.G.6
  • 13
    • 33748491707 scopus 로고    scopus 로고
    • Handheld rectilinear ion trap mass spectrometer
    • 1:CAS:528:DC%2BD28XnslKmuro%3D
    • Gao, L., Song, Q., Patterson, G.E., Cooks, R.G., Ouyang, Z.: Handheld rectilinear ion trap mass spectrometer. Anal. Chem. 78, 5994-6002 (2006)
    • (2006) Anal. Chem. , vol.78 , pp. 5994-6002
    • Gao, L.1    Song, Q.2    Patterson, G.E.3    Cooks, R.G.4    Ouyang, Z.5
  • 15
    • 35848950457 scopus 로고    scopus 로고
    • Miniaturization and geometry optimization of a polymer-based rectilinear ion trap
    • 1:CAS:528:DC%2BD2sXhtFSqs77P
    • Fico, M., Yu, M., Ouyang, Z., Cooks, R.G., Chappell, W.J.: Miniaturization and geometry optimization of a polymer-based rectilinear ion trap. Anal. Chem. 79, 8076-8082 (2007)
    • (2007) Anal. Chem. , vol.79 , pp. 8076-8082
    • Fico, M.1    Yu, M.2    Ouyang, Z.3    Cooks, R.G.4    Chappell, W.J.5
  • 16
    • 29744441809 scopus 로고    scopus 로고
    • Miniaturized rectilinear ion trap
    • Erickson, B.E.: Miniaturized rectilinear ion trap. Anal. Chem. 76, 305A (2004)
    • (2004) Anal. Chem. , vol.76 , pp. 305A
    • Erickson, B.E.1
  • 17
    • 79955762772 scopus 로고    scopus 로고
    • Multiplexed MS/MS in a miniature rectilinear ion trap
    • 1:CAS:528:DC%2BC3MXnt1Oiu7w%3D
    • Graichen, A.M., Vachet, R.W.: Multiplexed MS/MS in a miniature rectilinear ion trap. J. Am. Soc. Mass Spectrom. 22, 683-688 (2011)
    • (2011) J. Am. Soc. Mass Spectrom. , vol.22 , pp. 683-688
    • Graichen, A.M.1    Vachet, R.W.2
  • 18
    • 80054984622 scopus 로고    scopus 로고
    • Dual buffer gases for ion manipulation in a miniature ion trap mass spectrometer with a discontinuous atmospheric pressure interface
    • 1:CAS:528:DC%2BC3MXhtlahs7bM
    • Chen, T.-C., Xu, W., Ouyang, Z.: Dual buffer gases for ion manipulation in a miniature ion trap mass spectrometer with a discontinuous atmospheric pressure interface. Rapid Commun. Mass Spectrom. 25, 3274-3280 (2011)
    • (2011) Rapid Commun. Mass Spectrom. , vol.25 , pp. 3274-3280
    • Chen, T.-C.1    Xu, W.2    Ouyang, Z.3
  • 19
    • 64849094974 scopus 로고    scopus 로고
    • Handheld miniature ion trap mass spectrometers
    • 1:CAS:528:DC%2BD1MXjtVSisLk%3D
    • Ouyang, Z., Noll, R.J., Cooks, R.G.: Handheld miniature ion trap mass spectrometers. Anal. Chem. 81, 2421-2425 (2009)
    • (2009) Anal. Chem. , vol.81 , pp. 2421-2425
    • Ouyang, Z.1    Noll, R.J.2    Cooks, R.G.3
  • 20
    • 67249094274 scopus 로고    scopus 로고
    • Ion trap array mass analyzer: structure and performance
    • 1:CAS:528:DC%2BD1MXlvVyqsbk%3D
    • Li, X., Jiang, G., Luo, C., Xu, F., Wang, Y., Ding, L., Ding, C.-F.: Ion trap array mass analyzer: structure and performance. Anal. Chem. 81, 4840-4846 (2009)
    • (2009) Anal. Chem. , vol.81 , pp. 4840-4846
    • Li, X.1    Jiang, G.2    Luo, C.3    Xu, F.4    Wang, Y.5    Ding, L.6    Ding, C.-F.7
  • 21
    • 84873107377 scopus 로고    scopus 로고
    • Analytical performance of printed circuit board ion trap array mass analyzer with electrospray ionization
    • 1:CAS:528:DC%2BC3sXhtVGlsrjP
    • Chu, Y.-Q., Xiao, Y., Ling, X., Ding, C.-F.: Analytical performance of printed circuit board ion trap array mass analyzer with electrospray ionization. Chin. J. Anal. Chem. 41, 152-158 (2013)
    • (2013) Chin. J. Anal. Chem. , vol.41 , pp. 152-158
    • Chu, Y.-Q.1    Xiao, Y.2    Ling, X.3    Ding, C.-F.4
  • 22
    • 84881586365 scopus 로고    scopus 로고
    • Multiple mass analysis using an ion trap array (ITA) mass analyzer
    • 1:CAS:528:DC%2BC3sXht1ektr3N
    • Xiao, Y., Chu, Y., Ling, X., Ding, Z., Xu, C., Ding, L., Ding, C.-F.: Multiple mass analysis using an ion trap array (ITA) mass analyzer. J. Am. Soc. Mass Spectrom. 24, 1420-1427 (2013)
    • (2013) J. Am. Soc. Mass Spectrom. , vol.24 , pp. 1420-1427
    • Xiao, Y.1    Chu, Y.2    Ling, X.3    Ding, Z.4    Xu, C.5    Ding, L.6    Ding, C.-F.7
  • 23
    • 84887096815 scopus 로고    scopus 로고
    • Optimization of ion trap array mass analyzer by computer simulation
    • Luo, C., Ding, C.-F.: Optimization of ion trap array mass analyzer by computer simulation. Chin. J. Anal. Chem. 40, 989-995 (2012)
    • (2012) Chin. J. Anal. Chem. , vol.40 , pp. 989-995
    • Luo, C.1    Ding, C.-F.2
  • 24
    • 84902766858 scopus 로고    scopus 로고
    • Novel linear ion trap mass analyzer built with triangular electrodes
    • 1:CAS:528:DC%2BC2cXos1Wmu7c%3D
    • Xiao, Y., Ding, Z., Xu, C., Dai, X., Fang, X., Ding, C.-F.: Novel linear ion trap mass analyzer built with triangular electrodes. Anal. Chem. 86, 5733-5739 (2014)
    • (2014) Anal. Chem. , vol.86 , pp. 5733-5739
    • Xiao, Y.1    Ding, Z.2    Xu, C.3    Dai, X.4    Fang, X.5    Ding, C.-F.6
  • 25
    • 38849163615 scopus 로고    scopus 로고
    • Monitoring of toxic compounds in air using a handheld rectilinear ion trap mass spectrometer
    • 1:CAS:528:DC%2BD1cXis1yitw%3D%3D
    • Keil, A., Hernandez-Soto, H., Noll, R.J., Fico, M., Gao, L., Ouyang, Z., Cooks, R.G.: Monitoring of toxic compounds in air using a handheld rectilinear ion trap mass spectrometer. Anal. Chem. 80, 734-741 (2008)
    • (2008) Anal. Chem. , vol.80 , pp. 734-741
    • Keil, A.1    Hernandez-Soto, H.2    Noll, R.J.3    Fico, M.4    Gao, L.5    Ouyang, Z.6    Cooks, R.G.7
  • 26
    • 84873341371 scopus 로고    scopus 로고
    • Synchronized discharge ionization for analysis of volatile organic compounds using a hand-held ion trap mass spectrometer
    • 1:CAS:528:DC%2BC38XhvVGrtbzI
    • Chen, T.-C., Ouyang, Z.: Synchronized discharge ionization for analysis of volatile organic compounds using a hand-held ion trap mass spectrometer. Anal. Chem. 85, 1767-1772 (2013)
    • (2013) Anal. Chem. , vol.85 , pp. 1767-1772
    • Chen, T.-C.1    Ouyang, Z.2
  • 27
    • 0036311439 scopus 로고    scopus 로고
    • Influence of the 6th and 10th spatial harmonics on the peak shape of a quadrupole mass filter with round rods
    • 1:CAS:528:DC%2BD38XlvFKisbs%3D
    • Douglas, D.J., Konenkov, N.V.: Influence of the 6th and 10th spatial harmonics on the peak shape of a quadrupole mass filter with round rods. Rapid Commun. Mass Spectrom. 16, 1425-1431 (2002)
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1425-1431
    • Douglas, D.J.1    Konenkov, N.V.2
  • 28
    • 0011576753 scopus 로고    scopus 로고
    • Nonlinear field effects in quadrupole mass filters
    • 1:CAS:528:DyaK1MXlsFSjtLk%3D
    • Schulte, J., Shevchenko, P.V., Radchik, A.V.: Nonlinear field effects in quadrupole mass filters. Rev. Sci. Instrum. 70, 3566-3571 (1999)
    • (1999) Rev. Sci. Instrum. , vol.70 , pp. 3566-3571
    • Schulte, J.1    Shevchenko, P.V.2    Radchik, A.V.3
  • 29
    • 0034782798 scopus 로고    scopus 로고
    • Numerical investigation of the effect of electrode size on the behaviour of quadrupole mass filters
    • 1:CAS:528:DC%2BD3MXnsl2mt78%3D
    • Gibson, J.R., Taylor, S.: Numerical investigation of the effect of electrode size on the behaviour of quadrupole mass filters. Rapid Commun. Mass Spectrom. 15, 1960-1964 (2001)
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 1960-1964
    • Gibson, J.R.1    Taylor, S.2
  • 30
    • 77954519041 scopus 로고    scopus 로고
    • Quadrupole mass filters with added hexapole fields
    • 1:CAS:528:DC%2BC3cXnvVOgu78%3D
    • Xiao, Z., Zhao, X., Douglas, D.J.: Quadrupole mass filters with added hexapole fields. Rapid Commun. Mass Spectrom. 24, 1985-1992 (2010)
    • (2010) Rapid Commun. Mass Spectrom. , vol.24 , pp. 1985-1992
    • Xiao, Z.1    Zhao, X.2    Douglas, D.J.3
  • 31
  • 32
    • 84925649008 scopus 로고    scopus 로고
    • Mass resolution of linear quadrupole ion traps with round rods
    • 1:CAS:528:DC%2BC2cXhs1yisrfF
    • Douglas, D.J., Konenkov, N.V.: Mass resolution of linear quadrupole ion traps with round rods. Rapid Commun. Mass Spectrom. 28, 2252-2258 (2014)
    • (2014) Rapid Commun. Mass Spectrom. , vol.28 , pp. 2252-2258
    • Douglas, D.J.1    Konenkov, N.V.2
  • 33
    • 44949279082 scopus 로고
    • High-resolution on a quadrupole ion trap mass-spectrometer
    • 1:CAS:528:DyaK3MXltVansbs%3D
    • Schwartz, J.C., Syka, J.E.P., Jardine, I.: High-resolution on a quadrupole ion trap mass-spectrometer. J. Am. Soc. Mass Spectrom. 2, 198-204 (1991)
    • (1991) J. Am. Soc. Mass Spectrom. , vol.2 , pp. 198-204
    • Schwartz, J.C.1    Syka, J.E.P.2    Jardine, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.