메뉴 건너뛰기




Volumn 15, Issue 1, 2015, Pages

Challenges in standardization of blood pressure measurement at the population level

Author keywords

Blood pressure; Methodology; Surveillance

Indexed keywords

BLOOD PRESSURE; BLOOD PRESSURE MEASUREMENT; CLINICAL TRIAL; DEVICES; EUROPE; HEALTH SURVEY; HUMAN; HYPERTENSION; MULTICENTER STUDY; OSCILLOMETRY; PATHOPHYSIOLOGY; PHYSIOLOGY; PILOT STUDY; PROCEDURES; RETROSPECTIVE STUDY; STANDARD; STANDARDS; STATISTICS AND NUMERICAL DATA;

EID: 84928008683     PISSN: None     EISSN: 14712288     Source Type: Journal    
DOI: 10.1186/s12874-015-0020-3     Document Type: Article
Times cited : (56)

References (45)
  • 2
    • 0024428534 scopus 로고
    • Acute effects of exposure to cold on blood pressure, platelet function and sympathetic nervous activity in humans
    • 1:STN:280:DyaK3c%2FislKjtQ%3D%3D 2529881
    • Kawahara J, Sano H, Fukuzaki H, Saito K, Hirouchi H. Acute effects of exposure to cold on blood pressure, platelet function and sympathetic nervous activity in humans. Am J Hypertens. 1989;2(9):724-6.
    • (1989) Am J Hypertens , vol.2 , Issue.9 , pp. 724-726
    • Kawahara, J.1    Sano, H.2    Fukuzaki, H.3    Saito, K.4    Hirouchi, H.5
  • 4
    • 84860733386 scopus 로고    scopus 로고
    • The importance of accurate blood pressure measurement
    • 2911816 20740091
    • Handler J. The importance of accurate blood pressure measurement. Perm J. 2009;13(3):51-4.
    • (2009) Perm J , vol.13 , Issue.3 , pp. 51-54
    • Handler, J.1
  • 5
    • 0033543067 scopus 로고    scopus 로고
    • Accurate blood pressure measurement: Why does it matter?
    • 1230505 1:STN:280:DyaK1Mzpt1entA%3D%3D 10463050
    • Campbell NR, McKay DW. Accurate blood pressure measurement: why does it matter? CMAJ. 1999;161(3):277-8.
    • (1999) CMAJ , vol.161 , Issue.3 , pp. 277-278
    • Campbell, N.R.1    McKay, D.W.2
  • 7
    • 0025024896 scopus 로고
    • The measurement of blood pressure: Sitting or supine, once or twice?
    • 1:STN:280:DyaK3czmvFWnuw%3D%3D 2168453
    • Jamieson MJ, Webster J, Philips S, Jeffers TA, Scott AK, Robb OJ, et al. The measurement of blood pressure: sitting or supine, once or twice? J Hypertens. 1990;8(7):635-40.
    • (1990) J Hypertens , vol.8 , Issue.7 , pp. 635-640
    • Jamieson, M.J.1    Webster, J.2    Philips, S.3    Jeffers, T.A.4    Scott, A.K.5    Robb, O.J.6
  • 8
    • 0035352768 scopus 로고    scopus 로고
    • Effects of crossing legs on blood pressure measurement
    • 1:STN:280:DC%2BD387kvFWjuw%3D%3D 11881718
    • Keele-Smith R, Price-Daniel C. Effects of crossing legs on blood pressure measurement. Clin Nurs Res. 2001;10(2):202-13.
    • (2001) Clin Nurs Res , vol.10 , Issue.2 , pp. 202-213
    • Keele-Smith, R.1    Price-Daniel, C.2
  • 9
    • 0032989106 scopus 로고    scopus 로고
    • Arm position is important for blood pressure measurement
    • 1:STN:280:DyaK1M7pvFygsw%3D%3D 10100058
    • Netea RT, Lenders JW, Smits P, Thien T. Arm position is important for blood pressure measurement. J Hum Hypertens. 1999;13(2):105-9.
    • (1999) J Hum Hypertens , vol.13 , Issue.2 , pp. 105-109
    • Netea, R.T.1    Lenders, J.W.2    Smits, P.3    Thien, T.4
  • 10
    • 0031909537 scopus 로고    scopus 로고
    • Does it matter whether blood pressure measurements are taken with subjects sitting or supine?
    • 1:STN:280:DyaK1c3hs12qtQ%3D%3D 9557918
    • Netea RT, Smits P, Lenders JW, Thien T. Does it matter whether blood pressure measurements are taken with subjects sitting or supine? J Hypertens. 1998;16(3):263-8.
    • (1998) J Hypertens , vol.16 , Issue.3 , pp. 263-268
    • Netea, R.T.1    Smits, P.2    Lenders, J.W.3    Thien, T.4
  • 11
    • 12444277817 scopus 로고    scopus 로고
    • European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement
    • 12714851
    • O'Brien E, Asmar R, Beilin L, Imai Y, Mallion JM, Mancia G, et al. European society of hypertension recommendations for conventional, ambulatory and home blood pressure measurement. J Hypertens. 2003;21(5):821-48.
    • (2003) J Hypertens , vol.21 , Issue.5 , pp. 821-848
    • O'Brien, E.1    Asmar, R.2    Beilin, L.3    Imai, Y.4    Mallion, J.M.5    Mancia, G.6
  • 12
    • 0036528818 scopus 로고    scopus 로고
    • The effect of differences in measurement procedure on the comparability of blood pressure estimates in multi-centre studies
    • 12048426
    • Schulze MB, Kroke A, Saracci R, Boeing H. The effect of differences in measurement procedure on the comparability of blood pressure estimates in multi-centre studies. Blood Press Monit. 2002;7(2):95-104.
    • (2002) Blood Press Monit , vol.7 , Issue.2 , pp. 95-104
    • Schulze, M.B.1    Kroke, A.2    Saracci, R.3    Boeing, H.4
  • 13
    • 0001849046 scopus 로고
    • The British hypertension society protocol for the evaluation of blood pressure measuring devices
    • O'Brien E, Petrie J, Little W, de Swiet M, Padfield P. The British hypertension society protocol for the evaluation of blood pressure measuring devices. J Hypertens. 1993;11 Suppl 2:S43-62.
    • (1993) J Hypertens , vol.11 , pp. 43-S62
    • O'Brien, E.1    Petrie, J.2    Little, W.3    De Swiet, M.4    Padfield, P.5
  • 14
    • 76449087188 scopus 로고    scopus 로고
    • European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults
    • 20110786
    • O'Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R, et al. European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit. 2010;15(1):23-38.
    • (2010) Blood Press Monit , vol.15 , Issue.1 , pp. 23-38
    • O'Brien, E.1    Atkins, N.2    Stergiou, G.3    Karpettas, N.4    Parati, G.5    Asmar, R.6
  • 16
    • 0023758416 scopus 로고
    • Effects of bell versus diaphragm on indirect blood-pressure measurement
    • 3417461
    • Mauro AMP. Effects of bell versus diaphragm on indirect blood-pressure measurement. Heart Lung. 1988;17(5):489-94.
    • (1988) Heart Lung , vol.17 , Issue.5 , pp. 489-494
    • Mauro, A.M.P.1
  • 17
    • 18844411617 scopus 로고    scopus 로고
    • Bell or diaphragm in the measurement of blood pressure?
    • 1:CAS:528:DC%2BD2MXhtlOiurk%3D 15716689
    • Kantola I, Vesalainen R, Kangassalo K, Kariluoto A. Bell or diaphragm in the measurement of blood pressure? J Hypertens. 2005;23(3):499-503.
    • (2005) J Hypertens , vol.23 , Issue.3 , pp. 499-503
    • Kantola, I.1    Vesalainen, R.2    Kangassalo, K.3    Kariluoto, A.4
  • 18
    • 23944444279 scopus 로고    scopus 로고
    • Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care
    • 16077263
    • Coleman AJ, Steel SD, Ashworth M, Vowler SL, Shennan A. Accuracy of the pressure scale of sphygmomanometers in clinical use within primary care. Blood Press Monit. 2005;10(4):181-8.
    • (2005) Blood Press Monit , vol.10 , Issue.4 , pp. 181-188
    • Coleman, A.J.1    Steel, S.D.2    Ashworth, M.3    Vowler, S.L.4    Shennan, A.5
  • 19
    • 77449106884 scopus 로고    scopus 로고
    • Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
    • 19339994
    • de Greeff A, Lorde I, Wilton A, Seed P, Coleman AJ, Shennan AH. Calibration accuracy of hospital-based non-invasive blood pressure measuring devices. J Hum Hypertens. 2010;24(1):58-63.
    • (2010) J Hum Hypertens , vol.24 , Issue.1 , pp. 58-63
    • De Greeff, A.1    Lorde, I.2    Wilton, A.3    Seed, P.4    Coleman, A.J.5    Shennan, A.H.6
  • 20
    • 0000595816 scopus 로고
    • Standardisation of observers in blood-pressure measurement
    • 1:STN:280:DyaF2M%2FmtlSlsw%3D%3D 14258545
    • Rose G. Standardisation of observers in blood-pressure measurement. Lancet. 1965;1(7387):673-4.
    • (1965) Lancet , vol.1 , Issue.7387 , pp. 673-674
    • Rose, G.1
  • 21
    • 0035962451 scopus 로고    scopus 로고
    • ABC of hypertension: Blood pressure measurement. Part II-conventional sphygmomanometry: Technique of auscultatory blood pressure measurement
    • 1120188 1:STN:280:DC%2BD3MzgvFemug%3D%3D 11325773
    • Beevers G, Lip GY, O'Brien E. ABC of hypertension: blood pressure measurement. Part II-conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ. 2001;322(7293):1043-7.
    • (2001) BMJ , vol.322 , Issue.7293 , pp. 1043-1047
    • Beevers, G.1    Lip, G.Y.2    O'Brien, E.3
  • 22
    • 8844244275 scopus 로고    scopus 로고
    • End-digit preference in blood pressure recordings of patients with ischaemic heart disease in primary care
    • 15037875
    • de Lusignan S, Belsey J, Hague N, Dzregah B. End-digit preference in blood pressure recordings of patients with ischaemic heart disease in primary care. J Hum Hypertens. 2004;18(4):261-5.
    • (2004) J Hum Hypertens , vol.18 , Issue.4 , pp. 261-265
    • De Lusignan, S.1    Belsey, J.2    Hague, N.3    Dzregah, B.4
  • 23
    • 0022589119 scopus 로고
    • Terminal digit preference in blood pressure measurements: Effects on epidemiological associations
    • 1:STN:280:DyaL287mslWisQ%3D%3D 3957533
    • Hessel PA. Terminal digit preference in blood pressure measurements: effects on epidemiological associations. Int J Epidemiol. 1986;15(1):122-5.
    • (1986) Int J Epidemiol , vol.15 , Issue.1 , pp. 122-125
    • Hessel, P.A.1
  • 24
    • 0023025564 scopus 로고
    • Observer error in blood pressure measurement
    • 1491295 1:STN:280:DyaL2s%2FgtFOrsQ%3D%3D 3756693
    • Neufeld PD, Johnson DL. Observer error in blood pressure measurement. CMAJ. 1986;135(6):633-7.
    • (1986) CMAJ , vol.135 , Issue.6 , pp. 633-637
    • Neufeld, P.D.1    Johnson, D.L.2
  • 25
    • 12344334280 scopus 로고    scopus 로고
    • Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension
    • 15472497
    • Turner MJ, Baker AB, Kam PC. Effects of systematic errors in blood pressure measurements on the diagnosis of hypertension. Blood Press Monit. 2004;9(5):249-53.
    • (2004) Blood Press Monit , vol.9 , Issue.5 , pp. 249-253
    • Turner, M.J.1    Baker, A.B.2    Kam, P.C.3
  • 26
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure measurement in humans: A statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research
    • 1:CAS:528:DC%2BD2cXhtFaiu7rI 15611362
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN, et al. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the subcommittee of professional and public education of the American Heart Association Council on high blood pressure research. Hypertension. 2005;45(1):142-61.
    • (2005) Hypertension , vol.45 , Issue.1 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6
  • 27
    • 14844330152 scopus 로고    scopus 로고
    • WHO MONICA Project. MONICA manual
    • WHO MONICA Project. MONICA manual, part III: population survey, section 1: population survey data component. Volume 2012. 1997. Available at URL: http://www.thl.fi/publications/monica/manual/part3/iii-1.htm, URN:NBN:fi-fe19981131
    • (1997) Part III: Population Survey, Section 1: Population Survey Data Component , vol.2012
  • 29
    • 84897443921 scopus 로고    scopus 로고
    • 5.1 Blood pressure in Tolonen H. (Ed.) EHES manual, part B. Fieldwork procedures
    • H. Tolonen (eds) National Institute for Health and Welfare Helsinki
    • Tolonen H, Koponen P. 5.1 Blood pressure in Tolonen H. (Ed.) EHES manual, part B. Fieldwork procedures. In: Tolonen H, editor. EHES manual, part B fieldwork procedures. Helsinki: National Institute for Health and Welfare; 2013.
    • (2013) EHES Manual, Part B Fieldwork Procedures
    • Tolonen, H.1    Koponen, P.2
  • 33
    • 32744458943 scopus 로고    scopus 로고
    • Training materials. [ http://www.ehes.info/training-materials/index.htm ]
    • Training Materials
  • 34
    • 0030220091 scopus 로고    scopus 로고
    • Standardization of blood pressure measurement in an international comparative study
    • 1:STN:280:DyaK28zis1eltQ%3D%3D 8699206
    • Ataman SL, Cooper R, Rotimi C, McGee D, Osotimehin B, Kadiri S, et al. Standardization of blood pressure measurement in an international comparative study. J Clin Epidemiol. 1996;49(8):869-77.
    • (1996) J Clin Epidemiol , vol.49 , Issue.8 , pp. 869-877
    • Ataman, S.L.1    Cooper, R.2    Rotimi, C.3    McGee, D.4    Osotimehin, B.5    Kadiri, S.6
  • 35
    • 0041883662 scopus 로고    scopus 로고
    • National health and nutrition examination survey 1999-2000: Effect of observer training and protocol standardization on reducing blood pressure measurement error
    • 12954469
    • Ostchega Y, Prineas RJ, Paulose-Ram R, Grim CM, Willard G, Collins D. National health and nutrition examination survey 1999-2000: effect of observer training and protocol standardization on reducing blood pressure measurement error. J Clin Epidemiol. 2003;56(8):768-74.
    • (2003) J Clin Epidemiol , vol.56 , Issue.8 , pp. 768-774
    • Ostchega, Y.1    Prineas, R.J.2    Paulose-Ram, R.3    Grim, C.M.4    Willard, G.5    Collins, D.6
  • 36
    • 0029588480 scopus 로고
    • Assessment of blood pressure measurement quality in the baseline surveys of the WHO MONICA project
    • 8746637
    • Hense HW, Koivisto AM, Kuulasmaa K, Zaborskis A, Kupsc W, Tuomilehto J. Assessment of blood pressure measurement quality in the baseline surveys of the WHO MONICA project. J Hum Hypertens. 1995;9(12):935-46.
    • (1995) J Hum Hypertens , vol.9 , Issue.12 , pp. 935-946
    • Hense, H.W.1    Koivisto, A.M.2    Kuulasmaa, K.3    Zaborskis, A.4    Kupsc, W.5    Tuomilehto, J.6
  • 37
    • 0026058444 scopus 로고
    • Training and assessment of observers for blood-pressure measurement in hypertension research
    • 2041039
    • O'Brien E, Mee F, Tan KS, Atkins N, Omalley K. Training and assessment of observers for blood-pressure measurement in hypertension research. J Hum Hypertens. 1991;5(1):7-10.
    • (1991) J Hum Hypertens , vol.5 , Issue.1 , pp. 7-10
    • O'Brien, E.1    Mee, F.2    Tan, K.S.3    Atkins, N.4    Omalley, K.5
  • 38
    • 84928032492 scopus 로고    scopus 로고
    • European Commission Commission Regulation (EU) No 847/2012 on 19 September 2012 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the registration, evaluation, authorisation and restriction of chemicals (REACH) as regards mercury. In 847/2012. Edited by European Commission. Off J Eur Union, L253, 20.9.2012
    • European Commission. Commission Regulation (EU) No 847/2012 on 19 September 2012 amending Annex XVII to Regulation (EC) No 1907/2006 of the European Parliament and of the council on the registration, evaluation, authorisation and restriction of chemicals (REACH) as regards mercury. In 847/2012. Edited by European Commission. Off J Eur Union, L253, 20.9.2012.
  • 39
    • 84872961991 scopus 로고    scopus 로고
    • Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: National health and nutrition examination survey, 2009-2010
    • Ostchega Y, Zhang G, Sorlie P, Hughes JP, Reed-Gillette DS, Nwankwo T, et al. Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: national health and nutrition examination survey, 2009-2010. Natl Health Stat Report. 2012: (59):1-15.
    • (2012) Natl Health Stat Report , vol.59 , pp. 1-15
    • Ostchega, Y.1    Zhang, G.2    Sorlie, P.3    Hughes, J.P.4    Reed-Gillette, D.S.5    Nwankwo, T.6
  • 40
    • 78650309842 scopus 로고    scopus 로고
    • A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol
    • 20827175
    • Pruijm MT, Wuerzner G, Glatz N, Alwan H, Ponte B, Ackermann D, et al. A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol. Blood Press Monit. 2010;15(6):322-5.
    • (2010) Blood Press Monit , vol.15 , Issue.6 , pp. 322-325
    • Pruijm, M.T.1    Wuerzner, G.2    Glatz, N.3    Alwan, H.4    Ponte, B.5    Ackermann, D.6
  • 41
    • 84858708009 scopus 로고    scopus 로고
    • A perfect replacement for the mercury sphygmomanometer: The case of the hybrid blood pressure monitor
    • 1:STN:280:DC%2BC38zhtFWqtw%3D%3D 21900952
    • Stergiou GS, Karpettas N, Kollias A, Destounis A, Tzamouranis D. A perfect replacement for the mercury sphygmomanometer: the case of the hybrid blood pressure monitor. J Hum Hypertens. 2012;26(4):220-7.
    • (2012) J Hum Hypertens , vol.26 , Issue.4 , pp. 220-227
    • Stergiou, G.S.1    Karpettas, N.2    Kollias, A.3    Destounis, A.4    Tzamouranis, D.5
  • 42
    • 0023836953 scopus 로고
    • Recommendations for human blood pressure determination by sphygmomanometers. Report of a special task force appointed by the steering committee, American Heart Association
    • Frohlich ED, Grim CM, Labarthe DR, Maxwell MH, Perloff D, Weidman WH. Recommendations for human blood pressure determination by sphygmomanometers. Report of a special task force appointed by the steering committee, American Heart Association. Hypertension. 1988;11(2):209A-22A.
    • (1988) Hypertension , vol.11 , Issue.2 , pp. 209A-222A
    • Frohlich, E.D.1    Grim, C.M.2    Labarthe, D.R.3    Maxwell, M.H.4    Perloff, D.5    Weidman, W.H.6
  • 43
    • 0025382804 scopus 로고
    • The preference for the final digits in blood pressure determination: A continuing education experience
    • 2104131
    • Fornells JM, Borras JM, Balaguer-Vintro I. The preference for the final digits in blood pressure determination: a continuing education experience. Aten Primaria. 1990;7(2):102-5.
    • (1990) Aten Primaria , vol.7 , Issue.2 , pp. 102-105
    • Fornells, J.M.1    Borras, J.M.2    Balaguer-Vintro, I.3
  • 44
    • 0026427715 scopus 로고
    • How reliable is conventional blood pressure registration? Comparison with a semi-automatic device
    • 2028135
    • Kolb C, Huss R, Mengden T, Vetter W. How reliable is conventional blood pressure registration? Comparison with a semi-automatic device. Schweiz Rundsch Med Prax. 1991;80(12):286-90.
    • (1991) Schweiz Rundsch Med Prax , vol.80 , Issue.12 , pp. 286-290
    • Kolb, C.1    Huss, R.2    Mengden, T.3    Vetter, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.