메뉴 건너뛰기




Volumn 26, Issue 4, 2012, Pages 220-227

A perfect replacement for the mercury sphygmomanometer: The case of the hybrid blood pressure monitor

Author keywords

hybrid blood pressure monitor; international protocol; mercury sphygmomanometer; office blood pressure measurement; validation

Indexed keywords

ADULT; ARTICLE; AUSCULTATION; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; HUMAN; HYBRID MERCURY FREE AUSCULTATORY BLOOD PRESSURE MONITOR; INTERMETHOD COMPARISON; MALE; MEDICAL INSTRUMENTATION; MERCURY SPHYGMOMANOMETER; PRACTICE GUIDELINE; RELIABILITY; SPHYGMOMANOMETER; STANDARDIZATION; VALIDATION STUDY;

EID: 84858708009     PISSN: 09509240     EISSN: 14765527     Source Type: Journal    
DOI: 10.1038/jhh.2011.77     Document Type: Article
Times cited : (12)

References (20)
  • 2
    • 19944429836 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals. Part 1: Blood pressure measurement in humans: A statement for professionals from the subcommittee of professional and public education of the American Heart Association council on high blood pressure research
    • DOI 10.1161/01.HYP.0000150859.47929.8e
    • Pickering TG, Hall JE, Appel LJ, Falkner BE, Graves J, Hill MN et al. Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure measurement in humans: A statement for professionalsfrom the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. Hypertension 2005; 45: 142-161. (Pubitemid 40066429)
    • (2005) Hypertension , vol.45 , Issue.1 , pp. 142-161
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6    Jones, D.W.7    Kurtz, T.8    Sheps, S.G.9    Roccella, E.J.10
  • 3
    • 0035992025 scopus 로고    scopus 로고
    • Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults
    • DOI 10.1097/00126097-200202000-00002
    • O'Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit 2002; 7: 3-17. (Pubitemid 34304045)
    • (2002) Blood Pressure Monitoring , vol.7 , Issue.1 , pp. 3-17
    • O'Brien, E.1    Pickering, T.2    Asmar, R.3    Myers, M.4    Parati, G.5    Staessen, J.6    Mengden, T.7    Imai, Y.8    Waeber, B.9    Palatini, P.10    Gerin, W.11
  • 4
    • 76449087188 scopus 로고    scopus 로고
    • Working group on blood pressure monitoring of the european society of hypertension. European society of hypertension international protocol revision 2010 for the validation of blood pressure measuring devices in adults
    • O'Brien E, Atkins N, Stergiou G, Karpettas N, Parati G, Asmar R et al. Working Group on Blood Pressure Monitoring of the European Society of Hypertension. European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults. Blood Press Monit 2010; 15: 23-38.
    • (2010) Blood Press Monit. , Issue.15 , pp. 23-38
    • O'Brien, E.1    Atkins, N.2    Stergiou, G.3    Karpettas, N.4    Parati, G.5    Asmar, R.6
  • 5
    • 0025071770 scopus 로고
    • The British hypertension society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems
    • DOI 10.1097/00004872-199007000-00004
    • O'Brien E, Petrie J, Littler W, de Swiet M, Padfield PL, O0Malley K et al. The British Hypertension Society protocol for the evaluation of automated and semiautomated blood pressure measuring devices with special reference to ambulatory systems. J Hypertens 1990; 8: 607-619. (Pubitemid 20248492)
    • (1990) Journal of Hypertension , vol.8 , Issue.7 , pp. 607-619
    • O'Brien, E.1    Petrie, J.2    Littler, W.3    De Swiet, M.4    Padfield, P.L.5    O'Malley, K.6    Jamieson, M.7    Altman, D.8    Bland, M.9    Atkins, N.10
  • 6
    • 84858700276 scopus 로고    scopus 로고
    • Association for the advancement of medical instrumentation. Clinical validation of automated measurement type. Non-invasive sphygmomanometers-Part 2. American national standards institute
    • (accessed 12 March 2011)
    • Association for the Advancement of Medical Instrumentation. Clinical validation of automated measurement type. Non-invasive sphygmomanometers-Part 2. American National Standards Institute, Inc. ANSI/ AAMI/ISO 81060-2, 2009. http://webstore.ansi.org/ RecordDetail.aspx?skANSI%2FAAMI%2FISO+81060- 2%3A2009.(accessed 12 March 2011).
    • (2009) Inc. ANSI/ AAMI/ISO , pp. 81060-81062
  • 7
    • 84858704415 scopus 로고    scopus 로고
    • Mercury in measuring devices (amendment of Council Directive 76/769/EEC)
    • (accessed 12 March
    • Mercury in measuring devices (amendment of Council Directive 76/769/EEC). Directive 2007/51/EC of the European Parliament and of the Council of 25 September 2007 http://ec.europa.eu/enterprise/chemicals/legislation/markrestr/ amendments-en.htm (accessed 12 March 2011).
    • (2011) Directive 2007/51/EC of the European Parliament and of the Council of 25 September 2007
  • 9
    • 0037301090 scopus 로고    scopus 로고
    • What will replace the mercury sphygmomanometer?
    • DOI 10.1097/00126097-200302000-00005
    • Pickering TG. What will replace the mercury sphygmomanometer? Blood Press Monit 2003; 8: 23-25. (Pubitemid 36343967)
    • (2003) Blood Pressure Monitoring , vol.8 , Issue.1 , pp. 23-25
    • Pickering, T.G.1
  • 10
    • 0035203057 scopus 로고    scopus 로고
    • The case for a hybrid sphygmomanometer
    • DOI 10.1097/00126097-200108000-00002
    • Pickering T. The case for a hybrid sphygmomanometer. Blood Press Monit 2001; 6: 177-179. (Pubitemid 33116412)
    • (2001) Blood Pressure Monitoring , vol.6 , Issue.4 , pp. 177-179
    • Pickering, T.1
  • 11
    • 34547656096 scopus 로고    scopus 로고
    • Automated measurement of blood pressure in routine clinical practice
    • Myers MG, Godwin M. Automated measurement of blood pressure in routine clinical practice. J Clin Hypertens 2007; 9: 267-270.
    • (2007) J. Clin. Hypertens , vol.9 , pp. 267-270
    • Myers, M.G.1    Godwin, M.2
  • 12
    • 40049083842 scopus 로고    scopus 로고
    • Office blood pressure measurement with electronic devices: Has the time come?
    • DOI 10.1038/ajh.2007.78, PII AJH200778
    • Stergiou GS. Office blood pressure measurement with electronic devices: has the time come? Am J Hypertens 2008; 21: 246. (Pubitemid 351323284)
    • (2008) American Journal of Hypertension , vol.21 , Issue.3 , pp. 246
    • Stergiou, G.S.1
  • 13
    • 79954632013 scopus 로고    scopus 로고
    • Impact of applying the more stringent validation criteria of the revised European society of hypertension international protocol 2010 on previous validation studies
    • Stergiou G, Karpettas N, Atkins N, O'Brien E. Impact of applying the more stringent validation criteria of the revised European Society of Hypertension International Protocol 2010 on previous validation studies. Blood Press Monit 2011; 16: 67-73.
    • (2011) Blood Press Monit. , Issue.16 , pp. 67-73
    • Stergiou, G.1    Karpettas, N.2    Atkins, N.3    O'Brien, E.4
  • 14
    • 78650309842 scopus 로고    scopus 로고
    • A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol
    • Pruijm MT, Wuerzner G, Glatz N, Alwan H, Ponte B, Ackermann D et al. A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol. Blood Press Monit 2010; 15: 322-325.
    • (2010) Blood Press Monit. , vol.15 , pp. 322-325
    • Pruijm, M.T.1    Wuerzner, G.2    Glatz, N.3    Alwan, H.4    Ponte, B.5    Ackermann, D.6
  • 15
    • 1842531924 scopus 로고    scopus 로고
    • The Accoson Greenlight 300™, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults
    • DOI 10.1097/00126097-200402000-00004
    • Graves JW, Tibor M, Murtagh B, Klein L, Sheps SG. The Accoson Greenlight 300, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults. Blood Press Monit 2004; 9: 13-17. (Pubitemid 38429428)
    • (2004) Blood Pressure Monitoring , vol.9 , Issue.1 , pp. 13-17
    • Graves, J.W.1    Tibor, M.2    Murtagh, B.3    Klein, L.4    Sheps, S.G.5
  • 16
    • 38349063257 scopus 로고    scopus 로고
    • Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the international protocol
    • Stergiou GS, Giovas PP, Gkinos CP, Tzamouranis DG. Validation of the A&D UM-101 professional hybrid device for office blood pressure measurement according to the International Protocol. Blood Press Monit 2008; 13: 37-42.
    • (2008) Blood Press Monit. , vol.13 , pp. 37-42
    • Stergiou, G.S.1    Giovas, P.P.2    Gkinos, C.P.3    Tzamouranis, D.G.4
  • 17
    • 77149175979 scopus 로고    scopus 로고
    • Validation of three professional devices measuring office blood pressure according to three different methods: The omron bp10, the omron hbp t105 and the pic indolor professional
    • Asmar R, Khabouth J, Mattar J, Pecchioli V, Germano G. Validation of three professional devices measuring office blood pressure according to three different methods: The Omron BP10, the Omron HBP T105 and the Pic Indolor Professional. J Hypertens 2010; 28: 452-458.
    • (2010) J. Hypertens , vol.28 , pp. 452-458
    • Asmar, R.1    Khabouth, J.2    Mattar, J.3    Pecchioli, V.4    Germano, G.5
  • 18
    • 77955918547 scopus 로고    scopus 로고
    • Development and validation of a blinded hybrid device according to the European Hypertension Society protocol: Nissei DM- 3000
    • Tasker F, De Greeff A, Shennan AH. Development and validation of a blinded hybrid device according to the European Hypertension Society protocol: Nissei DM- 3000. J Hum Hypertens 2010; 24: 609-616.
    • (2010) J. Hum. Hypertens , vol.24 , pp. 609-616
    • Tasker, F.1    De Greeff, A.2    Shennan, A.H.3
  • 19
    • 84857189221 scopus 로고    scopus 로고
    • dabls Educational Trust (accessed 12 March
    • dabls Educational Trust. Devices for Blood Pressure Measurement. http://www.dableducational. org(accessed 12 March 2011).
    • (2011) Devices for Blood Pressure Measurement
  • 20
    • 76449109838 scopus 로고    scopus 로고
    • European Society of Hypertension International Protocol for the validation of blood pressure monitors: A critical review of its application and rationale for revision
    • Stergiou GS, Karpettas N, Atkins N, O'Brien E. European Society of Hypertension International Protocol for the validation of blood pressure monitors: A critical review of its application and rationale for revision. Blood Press Monit 2010; 15: 39-48.
    • (2010) Blood Press Monit. , vol.15 , pp. 39-48
    • Stergiou, G.S.1    Karpettas, N.2    Atkins, N.3    O'Brien, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.