메뉴 건너뛰기




Volumn 56, Issue , 2015, Pages 6-10

Smart bandage with wireless connectivity for uric acid biosensing as an indicator of wound status

Author keywords

Amperometric sensor; Biosensor; Radio frequency identification; Smart bandage; Uric acid; Wound monitoring

Indexed keywords

AMPEROMETRIC SENSORS; BIOSENSORS; BUDGET CONTROL; DATA TRANSFER; HEALTH CARE; NEAR FIELD COMMUNICATION; ORGANIC ACIDS; RADIO WAVES; SCREEN PRINTING; VOLTAGE REGULATORS;

EID: 84927651051     PISSN: 13882481     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.elecom.2015.03.018     Document Type: Article
Times cited : (255)

References (30)
  • 3
    • 84903140688 scopus 로고    scopus 로고
    • Omics profiles in chronic venous ulcer wound fluid: Innovative applications for translational medicine
    • F. Mannello, D. Ligi, M. Canale, and J.D. Raffetto Omics profiles in chronic venous ulcer wound fluid: innovative applications for translational medicine Expert. Rev. Mol. Diagn. 14 2014 737 762
    • (2014) Expert. Rev. Mol. Diagn. , vol.14 , pp. 737-762
    • Mannello, F.1    Ligi, D.2    Canale, M.3    Raffetto, J.D.4
  • 4
    • 84862182659 scopus 로고    scopus 로고
    • Epidemiology of chronic venous disorders in geographically diverse populations: Results from the Vein Consult Program
    • E. Rabe, J.J. Guex, A. Puskas, A. Scuderi, F. Fernandez Quesada, and V.C.P. Coordinators Epidemiology of chronic venous disorders in geographically diverse populations: results from the Vein Consult Program Int. Angiol. 31 2012 105 115
    • (2012) Int. Angiol. , vol.31 , pp. 105-115
    • Rabe, E.1    Guex, J.J.2    Puskas, A.3    Scuderi, A.4    Fernandez Quesada, F.5    Coordinators, V.C.P.6
  • 6
    • 0033517356 scopus 로고    scopus 로고
    • Mechanisms of disease - Cutaneous wound healing
    • A.J. Singer, and R.A.F. Clark Mechanisms of disease - cutaneous wound healing N. Engl. J. Med. 341 1999 738 746
    • (1999) N. Engl. J. Med. , vol.341 , pp. 738-746
    • Singer, A.J.1    Clark, R.A.F.2
  • 7
    • 84893385819 scopus 로고    scopus 로고
    • Electrochemical approaches to the development of smart bandages: A mini-review
    • A. McLister, J. Phair, J. Cundell, and J. Davis Electrochemical approaches to the development of smart bandages: a mini-review Electrochem. Commun. 40 2014 96 99
    • (2014) Electrochem. Commun. , vol.40 , pp. 96-99
    • McLister, A.1    Phair, J.2    Cundell, J.3    Davis, J.4
  • 9
    • 0029087538 scopus 로고
    • Long-term costs for foot ulcers in diabetic-patients in a multidisciplinary setting
    • J. Apelqvist, G. Ragnarsontennvall, J. Larsson, and U. Persson Long-term costs for foot ulcers in diabetic-patients in a multidisciplinary setting Foot Ankle Int. 16 1995 388 394
    • (1995) Foot Ankle Int. , vol.16 , pp. 388-394
    • Apelqvist, J.1    Ragnarsontennvall, G.2    Larsson, J.3    Persson, U.4
  • 10
    • 59149087749 scopus 로고    scopus 로고
    • Topical therapies for diabetic foot ulcers: Standard treatments
    • R. White, and C. McIntosh Topical therapies for diabetic foot ulcers: standard treatments J. Wound Care 17 2008 428 432
    • (2008) J. Wound Care , vol.17 , pp. 428-432
    • White, R.1    McIntosh, C.2
  • 11
    • 84862248904 scopus 로고    scopus 로고
    • Stress and pain associated with dressing change in patients with chronic wounds
    • D. Upton, K. Solowiej, C. Hender, and K.Y. Woo Stress and pain associated with dressing change in patients with chronic wounds J. Wound Care 21 2012 53-+
    • (2012) J. Wound Care , vol.21 , pp. 53-+
    • Upton, D.1    Solowiej, K.2    Hender, C.3    Woo, K.Y.4
  • 13
    • 36949032337 scopus 로고    scopus 로고
    • Miniaturized flexible temperature sensor
    • Y. Moser, and M.A.M. Gijs Miniaturized flexible temperature sensor J. Microelectromech. Syst. 16 2007 1349 1354
    • (2007) J. Microelectromech. Syst. , vol.16 , pp. 1349-1354
    • Moser, Y.1    Gijs, M.A.M.2
  • 14
    • 35148889325 scopus 로고    scopus 로고
    • Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study
    • D. McColl, B. Cartlidge, and P. Connolly Real-time monitoring of moisture levels in wound dressings in vitro: an experimental study Int. J. Surg. 5 2007 316 322
    • (2007) Int. J. Surg. , vol.5 , pp. 316-322
    • McColl, D.1    Cartlidge, B.2    Connolly, P.3
  • 15
    • 70350075811 scopus 로고    scopus 로고
    • Monitoring moisture without disturbing the wound dressing
    • D. McColl, M. MacDougall, L. Watret, and P. Connolly Monitoring moisture without disturbing the wound dressing Wounds UK 5 2009 94 99
    • (2009) Wounds UK , vol.5 , pp. 94-99
    • McColl, D.1    Macdougall, M.2    Watret, L.3    Connolly, P.4
  • 17
    • 71749102388 scopus 로고    scopus 로고
    • A hydrogel-based passive wireless sensor using a flex-circuit inductive transducer
    • V. Sridhar, and K. Takahata A hydrogel-based passive wireless sensor using a flex-circuit inductive transducer Sensors Actuators A Phys. 155 2009 58 65
    • (2009) Sensors Actuators A Phys. , vol.155 , pp. 58-65
    • Sridhar, V.1    Takahata, K.2
  • 18
    • 84859865117 scopus 로고    scopus 로고
    • Miniaturized textile-based multi-layer pH-sensor for wound monitoring applications
    • A. Nocke, A. Schroter, C. Cherif, and G. Gerlach Miniaturized textile-based multi-layer pH-sensor for wound monitoring applications Autex Res. J. 12 2012 20 22
    • (2012) Autex Res. J. , vol.12 , pp. 20-22
    • Nocke, A.1    Schroter, A.2    Cherif, C.3    Gerlach, G.4
  • 21
    • 74449093891 scopus 로고    scopus 로고
    • Approaching intelligent infection diagnostics: Carbon fibre sensor for electrochemical pyocyanin detection
    • D. Sharp, P. Gladstone, R.B. Smith, S. Forsythe, and J. Davis Approaching intelligent infection diagnostics: Carbon fibre sensor for electrochemical pyocyanin detection Bioelectrochemistry 77 2010 114 119
    • (2010) Bioelectrochemistry , vol.77 , pp. 114-119
    • Sharp, D.1    Gladstone, P.2    Smith, R.B.3    Forsythe, S.4    Davis, J.5
  • 22
    • 77952015667 scopus 로고    scopus 로고
    • A thin film detection/response system for pathogenic bacteria
    • J. Zhou, A.L. Loftus, G. Mulley, and A.T.A. Jenkins A thin film detection/response system for pathogenic bacteria J. Am. Chem. Soc. 132 2010 6566 6570
    • (2010) J. Am. Chem. Soc. , vol.132 , pp. 6566-6570
    • Zhou, J.1    Loftus, A.L.2    Mulley, G.3    Jenkins, A.T.A.4
  • 25
    • 42649098903 scopus 로고    scopus 로고
    • Integrated urate sensors for detecting wound infection
    • D. Sharp, and J. Davis Integrated urate sensors for detecting wound infection Electrochem. Commun. 10 2008 709 713
    • (2008) Electrochem. Commun. , vol.10 , pp. 709-713
    • Sharp, D.1    Davis, J.2
  • 26
    • 84891624440 scopus 로고    scopus 로고
    • Laser patterned carbon-polyethylene mesh electrodes for wound diagnostics
    • J. Phair, M. Joshi, J. Benson, D. McDonald, and J. Davis Laser patterned carbon-polyethylene mesh electrodes for wound diagnostics Mater. Chem. Phys. 143 2014 991 995
    • (2014) Mater. Chem. Phys. , vol.143 , pp. 991-995
    • Phair, J.1    Joshi, M.2    Benson, J.3    McDonald, D.4    Davis, J.5
  • 29
    • 0001135767 scopus 로고    scopus 로고
    • Biochemical analysis of wound fluid from nonhealing and healing chronic leg ulcers
    • N.J. Trengove, S.R. Langton, and M.C. Stacey Biochemical analysis of wound fluid from nonhealing and healing chronic leg ulcers Wound Repair Regen. 4 1996 234 239
    • (1996) Wound Repair Regen. , vol.4 , pp. 234-239
    • Trengove, N.J.1    Langton, S.R.2    Stacey, M.C.3
  • 30
    • 70350686382 scopus 로고    scopus 로고
    • Serum vitamin C and the prevalence of vitamin C deficiency in the United States: 2003-2004 National Health and Nutrition Examination Survey (NHANES)
    • R.L. Schleicher, M.D. Carroll, E.S. Ford, and D.A. Lacher Serum vitamin C and the prevalence of vitamin C deficiency in the United States: 2003-2004 National Health and Nutrition Examination Survey (NHANES) Am. J. Clin. Nutr. 90 2009 1252 1263
    • (2009) Am. J. Clin. Nutr. , vol.90 , pp. 1252-1263
    • Schleicher, R.L.1    Carroll, M.D.2    Ford, E.S.3    Lacher, D.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.