메뉴 건너뛰기




Volumn 74, Issue 5, 2015, Pages 908-911

Urate crystal deposition in asymptomatic hyperuricaemia and symptomatic gout: A dual energy CT study

Author keywords

[No Author keywords available]

Indexed keywords

URATE; URIC ACID;

EID: 84926624187     PISSN: 00034967     EISSN: 14682060     Source Type: Journal    
DOI: 10.1136/annrheumdis-2014-206397     Document Type: Article
Times cited : (194)

References (20)
  • 1
    • 0015310327 scopus 로고
    • The influence of temperature on the solubility of monosodium urate
    • Loeb JN. The influence of temperature on the solubility of monosodium urate. Arthritis Rheum 1972; 15:189-92.
    • (1972) Arthritis Rheum , vol.15 , pp. 189-192
    • Loeb, J.N.1
  • 2
    • 32944468985 scopus 로고    scopus 로고
    • Gout-associated uric acid crystals activate the NALP3 inflammasome
    • Martinon F, Petrilli V, Mayor A., et al. Gout-associated uric acid crystals activate the NALP3 inflammasome. Nature 2006; 440:237-41.
    • (2006) Nature , vol.440 , pp. 237-241
    • Martinon, F.1    Petrilli, V.2    Mayor, A.3
  • 3
    • 77951759092 scopus 로고    scopus 로고
    • Cellular characterization of the gouty tophus: A quantitative analysis
    • Dalbeth N, Pool B, Gamble G.D., et al. Cellular characterization of the gouty tophus: a quantitative analysis. Arthritis Rheum 2010; 62:1549-56.
    • (2010) Arthritis Rheum , vol.62 , pp. 1549-1556
    • Dalbeth, N.1    Pool, B.2    Gamble, G.D.3
  • 4
    • 0023634573 scopus 로고
    • Asymptomatic Hyperuricemia. Risks and consequences in the normative aging study
    • Campion EW, Glynn RJ, DeLabry LO Asymptomatic hyperuricemia. Risks and consequences in the Normative Aging Study. Am J Med 1987; 82:421-6.
    • (1987) Am J Med , vol.82 , pp. 421-426
    • Campion, E.W.1    Glynn, R.J.2    DeLabry, L.O.3
  • 5
    • 33745162895 scopus 로고    scopus 로고
    • Low-cost, simultaneous, single-sequence genotyping of the HLA-A, HLA-B and HLA-C loci
    • Abbott WG, Tukuitonga CF, Ofanoa M, et al Low-cost, simultaneous, single-sequence genotyping of the HLA-A, HLA-B and HLA-C loci. Tissue Antigens 2006; 68:28-37.
    • (2006) Tissue Antigens , vol.68 , pp. 28-37
    • Abbott, W.G.1    Tukuitonga, C.F.2    Ofanoa, M.3
  • 6
    • 77950538946 scopus 로고    scopus 로고
    • Epidemiology of gout in women: Fifty-two-year followup of a prospective cohort
    • Bhole V, de Vera M, Rahman MM, et al Epidemiology of gout in women: fifty-two-year followup of a prospective cohort. Arthritis Rheum 2010; 62:1069-76.
    • (2010) Arthritis Rheum , vol.62 , pp. 1069-1076
    • Bhole, V.1    De Vera, M.2    Rahman, M.M.3
  • 7
    • 81255178499 scopus 로고    scopus 로고
    • Reproducibility of musculoskeletal ultrasound for determining monosodium urate deposition: Concordance between readers
    • Howard RG, Pillinger MH, Gyftopoulos S, et al Reproducibility of musculoskeletal ultrasound for determining monosodium urate deposition: concordance between readers. Arthritis Care Res (Hoboken) 2011; 63:1456-62.
    • (2011) Arthritis Care Res (Hoboken) , vol.63 , pp. 1456-1462
    • Howard, R.G.1    Pillinger, M.H.2    Gyftopoulos, S.3
  • 8
    • 78651380618 scopus 로고    scopus 로고
    • Joint and tendon subclinical involvement suggestive of gouty arthritis in asymptomatic Hyperuricemia: An ultrasound controlled study
    • Pineda C, Amezcua-Guerra LM, Solano C., et al. Joint and tendon subclinical involvement suggestive of gouty arthritis in asymptomatic hyperuricemia: an ultrasound controlled study. Arthritis Res Ther 2011; 13:R4.
    • (2011) Arthritis Res Ther , vol.13 , pp. R4
    • Pineda, C.1    Amezcua-Guerra, L.M.2    Solano, C.3
  • 9
    • 82955198462 scopus 로고    scopus 로고
    • Diagnosis of gout in patients with asymptomatic Hyperuricaemia: A pilot ultrasound study
    • De Miguel E., Puig JG, Castillo C, et al Diagnosis of gout in patients with asymptomatic hyperuricaemia: a pilot ultrasound study. Ann Rheum Dis 2012; 71:157-8.
    • (2012) Ann Rheum Dis , vol.71 , pp. 157-158
    • De Miguel, E.1    Puig, J.G.2    Castillo, C.3
  • 10
    • 84906738807 scopus 로고    scopus 로고
    • A pilot study on dual-energy computed tomography for detection of urate deposits in renal transplant patients with asymptomatic Hyperuricemia
    • Kimura-Hayama E., Criales-Vera S, Nicolaou S., et al. A pilot study on dual-energy computed tomography for detection of urate deposits in renal transplant patients with asymptomatic hyperuricemia. J Clin Rheumatol 2014; 20:306-9.
    • (2014) J Clin Rheumatol , vol.20 , pp. 306-309
    • Kimura-Hayama, E.1    Criales-Vera, S.2    Nicolaou, S.3
  • 11
    • 84931005829 scopus 로고    scopus 로고
    • Features of urate deposition in patients with gouty arthritis of the foot using dual-energy computed tomography
    • Published Online First
    • Sun Y, Ma L, Zhou Y., et al. Features of urate deposition in patients with gouty arthritis of the foot using dual-energy computed tomography. Int J Rheum Dis 2013. Published Online First.
    • (2013) Int J Rheum Dis
    • Sun, Y.1    Ma, L.2    Zhou, Y.3
  • 12
    • 70349378460 scopus 로고    scopus 로고
    • Dual energy computed tomography in tophaceous gout
    • Choi HK, Al-Arfaj AM, Eftekhari A., et al. Dual energy computed tomography in tophaceous gout. Ann Rheum Dis 2009; 68:1609-12.
    • (2009) Ann Rheum Dis , vol.68 , pp. 1609-1612
    • Choi, H.K.1    Al-Arfaj, A.M.2    Eftekhari, A.3
  • 13
    • 84855199323 scopus 로고    scopus 로고
    • Assessment of tophus size: A comparison between physical measurement methods and dual-energy computed tomography scanning
    • Dalbeth N, Aati O, Gao A., et al. Assessment of tophus size: a comparison between physical measurement methods and dual-energy computed tomography scanning. J Clin Rheumatol 2012; 18:23-7.
    • (2012) J Clin Rheumatol , vol.18 , pp. 23-27
    • Dalbeth, N.1    Aati, O.2    Gao, A.3
  • 14
    • 84906098734 scopus 로고    scopus 로고
    • Artifacts in dual-energy CT gout protocol: A review of 50 suspected cases with an artifact identification guide
    • Mallinson PI, Coupal T, Reisinger C., et al. Artifacts in dual-energy CT gout protocol: a review of 50 suspected cases with an artifact identification guide. AJR Am J Roentgenol 2014; 203:W103-9.
    • (2014) AJR Am J Roentgenol , vol.203 , pp. W103-9
    • Mallinson, P.I.1    Coupal, T.2    Reisinger, C.3
  • 15
    • 78751679715 scopus 로고    scopus 로고
    • Development of a computed tomography method of scoring bone erosion in patients with gout: Validation and clinical implications
    • Dalbeth N, Doyle A, Boyer L., et al. Development of a computed tomography method of scoring bone erosion in patients with gout: validation and clinical implications. Rheumatology (Oxford) 2011; 50:410-16.
    • (2011) Rheumatology (Oxford) , vol.50 , pp. 410-416
    • Dalbeth, N.1    Doyle, A.2    Boyer, L.3
  • 16
    • 67651225617 scopus 로고    scopus 로고
    • Mechanisms of bone erosion in gout: A quantitative analysis using plain radiography and computed tomography
    • Dalbeth N, Clark B, Gregory K., et al. Mechanisms of bone erosion in gout: a quantitative analysis using plain radiography and computed tomography. Ann Rheum Dis 2009; 68:1290-5.
    • (2009) Ann Rheum Dis , vol.68 , pp. 1290-1295
    • Dalbeth, N.1    Clark, B.2    Gregory, K.3
  • 17
    • 34247625586 scopus 로고    scopus 로고
    • Computed tomography measurement of tophus volume: Comparison with physical measurement
    • Dalbeth N, Clark B, Gregory K., et al. Computed tomography measurement of tophus volume: comparison with physical measurement. Arthritis Rheum 2007; 57:461-5.
    • (2007) Arthritis Rheum , vol.57 , pp. 461-465
    • Dalbeth, N.1    Clark, B.2    Gregory, K.3
  • 18
    • 84901636779 scopus 로고    scopus 로고
    • Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout
    • Huppertz A, Hermann KG, Diekhoff T, et al Systemic staging for urate crystal deposits with dual-energy CT and ultrasound in patients with suspected gout. Rheumatol Int 2014; 34:763-71.
    • (2014) Rheumatol Int , vol.34 , pp. 763-771
    • Huppertz, A.1    Hermann, K.G.2    Diekhoff, T.3
  • 19
    • 84898824246 scopus 로고    scopus 로고
    • Gout tophus detection - A comparison of dual-energy CT (DECT) and histology
    • Melzer R, Pauli C, Treumann T., et al. Gout tophus detection-a comparison of dual-energy CT (DECT) and histology. Semin Arthritis Rheum 2014; 43:662-5.
    • (2014) Semin Arthritis Rheum , vol.43 , pp. 662-665
    • Melzer, R.1    Pauli, C.2    Treumann, T.3
  • 20
    • 85027906973 scopus 로고    scopus 로고
    • Relationship between structural joint damage and urate deposition in gout: A plain radiography and dual-energy CT study
    • Dalbeth N, Aati O, Kalluru R., et al. Relationship between structural joint damage and urate deposition in gout: a plain radiography and dual-energy CT study. Ann Rheum Dis 2014.
    • (2014) Ann Rheum Dis
    • Dalbeth, N.1    Aati, O.2    Kalluru, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.