Volumn 149, Issue 3, 2015, Pages 799-805.e2

Embrella embolic deflection device for cerebral protection during transcatheter aortic valve replacement

Author keywords

aortic valve stenosis; cerebral embolic protection device; cerebral ischemic injury; Embrella Embolic Deflector System; intracranial embolism; transcatheter aortic valve replacement

Indexed keywords

AGED; ARTICLE; BRAIN ANGIOGRAPHY; BRAIN INJURY; BRAIN PROTECTION; BRAIN REGION; BRAIN SIZE; CLINICAL ARTICLE; COMPARATIVE STUDY; DIFFUSION WEIGHTED IMAGING; DISEASE SEVERITY; EMBOLIC PROTECTION DEVICE; FEMALE; HUMAN; MALE; NEUROIMAGING; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SCANNER; PERCUTANEOUS AORTIC VALVE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSIENT ISCHEMIC ATTACK; VERY ELDERLY; ADVERSE EFFECTS; AORTA VALVE; AORTIC VALVE STENOSIS; BRAIN ISCHEMIA; DEVICES; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; PATHOPHYSIOLOGY; PROSTHESIS DESIGN; RISK FACTOR; SEVERITY OF ILLNESS INDEX; TIME FACTOR; TREATMENT OUTCOME;

EID: 84926176786     PISSN: 00225223     EISSN: 1097685X     Source Type: Journal    
DOI: 10.1016/j.jtcvs.2014.05.097     Document Type: Article
Times cited : (55)

References (18)
  • 1
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: Acute and late outcomes of the multicenter Canadian experience
    • J. Rodes-Cabau, J.G. Webb, A. Cheung, J. Ye, E. Dumont, and C.M. Feindel Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience J Am Coll Cardiol 55 2010 1080 1090
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1080-1090
    • Rodes-Cabau, J.1    Webb, J.G.2    Cheung, A.3    Ye, J.4    Dumont, E.5    Feindel, C.M.6
  • 3
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, M. Mack, D.C. Miller, J.W. Moses, and L.G. Svensson Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3    Miller, D.C.4    Moses, J.W.5    Svensson, L.G.6
  • 4
    • 78449263604 scopus 로고    scopus 로고
    • Embolic cerebral insults after transapical aortic valve implantation detected by magnetic resonance imaging
    • M. Arnold, S. Schulz-Heise, S. Achenbach, S. Ott, A. Dorfler, and D. Ropers Embolic cerebral insults after transapical aortic valve implantation detected by magnetic resonance imaging JACC Cardiovasc Interv 3 2010 1126 1132
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 1126-1132
    • Arnold, M.1    Schulz-Heise, S.2    Achenbach, S.3    Ott, S.4    Dorfler, A.5    Ropers, D.6
  • 5
    • 77949918630 scopus 로고    scopus 로고
    • Risk and fate of cerebral embolism after transfemoral aortic valve implantation: A prospective pilot study with diffusion-weighted magnetic resonance imaging
    • A. Ghanem, A. Muller, C.P. Nahle, J. Kocurek, N. Werner, and C. Hammerstingl Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusion-weighted magnetic resonance imaging J Am Coll Cardiol 55 2010 1427 1432
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1427-1432
    • Ghanem, A.1    Muller, A.2    Nahle, C.P.3    Kocurek, J.4    Werner, N.5    Hammerstingl, C.6
  • 6
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches
    • J. Rodes-Cabau, E. Dumont, R.H. Boone, E. Larose, R. Bagur, and R. Gurvitch Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches J Am Coll Cardiol 57 2011 18 28
    • (2011) J Am Coll Cardiol , vol.57 , pp. 18-28
    • Rodes-Cabau, J.1    Dumont, E.2    Boone, R.H.3    Larose, E.4    Bagur, R.5    Gurvitch, R.6
  • 7
    • 84155172936 scopus 로고    scopus 로고
    • Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: Assessment of predictive risk factors and the relationship to subsequent health status
    • T.A. Fairbairn, A.N. Mather, P. Bijsterveld, G. Worthy, S. Currie, and A.J. Goddard Diffusion-weighted MRI determined cerebral embolic infarction following transcatheter aortic valve implantation: assessment of predictive risk factors and the relationship to subsequent health status Heart 98 2012 18 23
    • (2012) Heart , vol.98 , pp. 18-23
    • Fairbairn, T.A.1    Mather, A.N.2    Bijsterveld, P.3    Worthy, G.4    Currie, S.5    Goddard, A.J.6
  • 8
    • 77649113087 scopus 로고    scopus 로고
    • Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study
    • P. Kahlert, S.C. Knipp, M. Schlamann, M. Thielmann, F. Al-Rashid, and M. Weber Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study Circulation 121 2010 870 878
    • (2010) Circulation , vol.121 , pp. 870-878
    • Kahlert, P.1    Knipp, S.C.2    Schlamann, M.3    Thielmann, M.4    Al-Rashid, F.5    Weber, M.6
  • 9
    • 50849089302 scopus 로고    scopus 로고
    • Atrial fibrillation in stroke-free patients is associated with memory impairment and hippocampal atrophy
    • S. Knecht, C. Oelschlager, T. Duning, H. Lohmann, J. Albers, and C. Stehling Atrial fibrillation in stroke-free patients is associated with memory impairment and hippocampal atrophy Eur Heart J 29 2008 2125 2132
    • (2008) Eur Heart J , vol.29 , pp. 2125-2132
    • Knecht, S.1    Oelschlager, C.2    Duning, T.3    Lohmann, H.4    Albers, J.5    Stehling, C.6
  • 11
    • 36849073170 scopus 로고    scopus 로고
    • Embolic protection devices for carotid artery stenting: Have they made a significant difference in outcomes'
    • M.D. Atkins, and R.L. Bush Embolic protection devices for carotid artery stenting: have they made a significant difference in outcomes' Semin Vasc Surg 20 2007 244 251
    • (2007) Semin Vasc Surg , vol.20 , pp. 244-251
    • Atkins, M.D.1    Bush, R.L.2
  • 13
    • 84871211131 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • A.P. Kappetein, S.J. Head, P. Genereux, N. Piazza, N.M. van Mieghem, and E.H. Blackstone Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document J Thorac Cardiovasc Surg 145 2013 6 23
    • (2013) J Thorac Cardiovasc Surg , vol.145 , pp. 6-23
    • Kappetein, A.P.1    Head, S.J.2    Genereux, P.3    Piazza, N.4    Van Mieghem, N.M.5    Blackstone, E.H.6
  • 14
    • 0037337064 scopus 로고    scopus 로고
    • Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: A systematic review of the literature
    • A. Kastrup, K. Groschel, H. Krapf, B.R. Brehm, J. Dichgans, and J.B. Schulz Early outcome of carotid angioplasty and stenting with and without cerebral protection devices: a systematic review of the literature Stroke 34 2003 813 819
    • (2003) Stroke , vol.34 , pp. 813-819
    • Kastrup, A.1    Groschel, K.2    Krapf, H.3    Brehm, B.R.4    Dichgans, J.5    Schulz, J.B.6
  • 15
    • 79959836271 scopus 로고    scopus 로고
    • A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention
    • J.P. Carpenter, J.T. Carpenter, A. Tellez, J.G. Webb, G.H. Yi, and J.F. Granada A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention J Vasc Surg 54 2011 174 181.e1
    • (2011) J Vasc Surg , vol.54 , pp. 174-181e1
    • Carpenter, J.P.1    Carpenter, J.T.2    Tellez, A.3    Webb, J.G.4    Yi, G.H.5    Granada, J.F.6
  • 16
    • 80155173398 scopus 로고    scopus 로고
    • Embol-X intraaortic filter and transaortic approach for improved cerebral protection in transcatheter aortic valve implantation
    • P.Y. Etienne, S. Papadatos, D. Pieters, E. El Khoury, F. Alexis, and J. Price Embol-X intraaortic filter and transaortic approach for improved cerebral protection in transcatheter aortic valve implantation Ann Thorac Surg 92 2011 e95 e96
    • (2011) Ann Thorac Surg , vol.92 , pp. e95-e96
    • Etienne, P.Y.1    Papadatos, S.2    Pieters, D.3    El Khoury, E.4    Alexis, F.5    Price, J.6
  • 17
    • 84865452176 scopus 로고    scopus 로고
    • First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions
    • K. Onsea, P. Agostoni, M. Samim, M. Voskuil, J. Kluin, and R. Budde First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions EuroIntervention 8 2012 51 56
    • (2012) EuroIntervention , vol.8 , pp. 51-56
    • Onsea, K.1    Agostoni, P.2    Samim, M.3    Voskuil, M.4    Kluin, J.5    Budde, R.6
  • 18
    • 84860381197 scopus 로고    scopus 로고
    • First-in-man use of a novel EPD for patients undergoing transcatheter aortic valve implantation
    • C.K. Naber, A. Ghanem, A.A. Abizaid, A. Wolf, J.M. Sinning, and N. Werner First-in-man use of a novel EPD for patients undergoing transcatheter aortic valve implantation EuroIntervention 8 2012 43 50
    • (2012) EuroIntervention , vol.8 , pp. 43-50
    • Naber, C.K.1    Ghanem, A.2    Abizaid, A.A.3    Wolf, A.4    Sinning, J.M.5    Werner, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.