메뉴 건너뛰기




Volumn 19, Issue 6, 2014, Pages

Examiner's finger-mounted fetal tissue oximetry

Author keywords

examiner; fetal tissue oximetry; finger pulp; near infrared spectroscopy; parturition.

Indexed keywords

OXIMETERS; OXYGEN; STATISTICAL MECHANICS;

EID: 84925550340     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.JBO.19.6.067008     Document Type: Article
Times cited : (24)

References (18)
  • 1
    • 0028027997 scopus 로고
    • Clinical value of antenatal fetal pulse oximetry
    • E. van Oudgaarden and N. Johnson, "Clinical value of antenatal fetal pulse oximetry," J. Perinat. Med. 22(4), 295-300 (1994). (Pubitemid 24343744)
    • (1994) Journal of Perinatal Medicine , vol.22 , Issue.4 , pp. 295-300
    • Van Oudgaarden, E.1    Johnson, N.2
  • 3
    • 79951627836 scopus 로고    scopus 로고
    • Fetal pulse oximetry
    • G. A. Dildy, "Fetal pulse oximetry," Clin. Obstet. Gynecol. 54(1), 66-73 (2011).
    • (2011) Clin. Obstet. Gynecol. , vol.54 , Issue.1 , pp. 66-73
    • Dildy, G.A.1
  • 6
    • 34250335267 scopus 로고    scopus 로고
    • Fetal pulse oximetry for fetal assessment in labour
    • C. E. East et al., "Fetal pulse oximetry for fetal assessment in labour," Cochrane. Database Syst. Rev. 2, CD004075 (2007).
    • (2007) Cochrane. Database Syst. Rev. , vol.2
    • East, C.E.1
  • 7
    • 84856248008 scopus 로고    scopus 로고
    • Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength
    • N. Stuban, M. Niwayama, and H. Santha, "Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength," Sensors (Basel) 12(12), 895-904 (2012).
    • (2012) Sensors (Basel) , vol.12 , Issue.12 , pp. 895-904
    • Stuban, N.1    Niwayama, M.2    Santha, H.3
  • 9
    • 0031711208 scopus 로고    scopus 로고
    • Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique
    • DOI 10.1088/0031-9155/43/9/003, PII S003191559886507X
    • C. R. Simpson et al., "Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique," Phys. Med. Biol. 43(9), 2465-2478 (1998). (Pubitemid 28414854)
    • (1998) Physics in Medicine and Biology , vol.43 , Issue.9 , pp. 2465-2478
    • Simpson, C.R.1    Kohl, M.2    Essenpreis, M.3    Cope, M.4
  • 12
    • 0025551790 scopus 로고
    • A review of the opticalproperties of biological tissues
    • W. F. Cheong, S. A. Prahl, and A. J. Welch, "A review of the opticalproperties of biological tissues," IEEE J. Quant. Electron. 26(12), 2166-2185 (1990).
    • (1990) J. Quant. Electron. , vol.26 , Issue.12 , pp. 2166-2185
    • Cheong, W.F.1    Prahl, S.A.2    Welch, A.J.3
  • 13
    • 0029060006 scopus 로고
    • Performance comparison of several published tissue near-infrared spectroscopy algorithms
    • S. J. Matcher et al., "Performance comparison of several published tissue near-infrared spectroscopy algorithms," Anal. Biochem. 227(1), 54-68 (1995).
    • (1995) Anal. Biochem. , vol.227 , Issue.1 , pp. 54-68
    • Matcher, S.J.1
  • 14
    • 12244284620 scopus 로고    scopus 로고
    • Cerebral hemoglobin concentration and oxygen saturation measured by intensity modulated optical spectroscopy in the human fetus during labor
    • DOI 10.1515/JPM.2002.078
    • J. Chipchase et al., "Cerebral hemoglobin concentration and oxygen saturation measured by intensity modulated optical spectroscopy in the human fetus during labor," J. Perinat. Med. 30(6), 502-509 (2002). (Pubitemid 36014764)
    • (2002) Journal of Perinatal Medicine , vol.30 , Issue.6 , pp. 502-509
    • Chipchase, J.1    Kirkby, D.2    Peebles, D.3    Cope, M.4    Rodeck, C.5
  • 15
    • 0034164356 scopus 로고    scopus 로고
    • Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approaches
    • V. Quaresima et al., "Noninvasive measurement of cerebral hemoglobin oxygen saturation using two near infrared spectroscopy approaches," J. Biomed. Opt. 5(2), 201-205 (2000).
    • (2000) J. Biomed. Opt. , vol.5 , Issue.2 , pp. 201-205
    • Quaresima, V.1
  • 17
    • 84888323997 scopus 로고    scopus 로고
    • Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth
    • G. Pichler et al., "Reference ranges for regional cerebral tissue oxygen saturation and fractional oxygen extraction in neonates during immediate transition after birth," J. Pediatr. 163(6), 1558-1563 (2013).
    • (2013) J. Pediatr. , vol.163 , Issue.6 , pp. 1558-1563
    • Pichler, G.1
  • 18
    • 80053489127 scopus 로고    scopus 로고
    • Pulse oximetry in pediatric practice
    • S. Fouzas, K. N. Priftis, and M. B. Anthoracopoulos, "Pulse oximetry in pediatric practice," Pediatrics 128(4), 740-752 (2011).
    • (2011) Pediatrics , vol.128 , Issue.4 , pp. 740-752
    • Fouzas, S.1    Priftis, K.N.2    Anthoracopoulos, M.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.