메뉴 건너뛰기




Volumn 12, Issue 1, 2012, Pages 895-904

Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength

Author keywords

CW NIRS; Oximeter; Phantom; Plethysmograph; Pulsatile; Reflectance pulse oximetry

Indexed keywords

ARTERY; ARTICLE; COMPUTER SIMULATION; ELECTRONICS; HEAD; IMAGE QUALITY; INSTRUMENTATION; OXIMETRY; PHYSIOLOGY; PRESSURE; PULSE RATE; SIGNAL PROCESSING; VASCULARIZATION;

EID: 84856248008     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s120100895     Document Type: Article
Times cited : (17)

References (17)
  • 2
    • 33751337831 scopus 로고    scopus 로고
    • Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
    • doi: 10.1117/1.2335429
    • Pogue, B.W.; Patterson, M.S. Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. J. Biomed. Opt. 2006, doi: 10.1117/1.2335429.
    • (2006) J. Biomed. Opt
    • Pogue, B.W.1    Patterson, M.S.2
  • 3
    • 13244252339 scopus 로고    scopus 로고
    • Multilayer modeling of reflectance pulse oximetry
    • Reuss, J.L. Multilayer modeling of reflectance pulse oximetry. IEEE Trans. Biomed Eng. 2005, 52, 153-159.
    • (2005) IEEE Trans. Biomed Eng , vol.52 , pp. 153-159
    • Reuss, J.L.1
  • 5
    • 66549123011 scopus 로고    scopus 로고
    • Adjustable fetal phantom for pulse oximetry
    • Stuban, N.; Niwayama, M. Adjustable fetal phantom for pulse oximetry. Rev. Sci. Instrum. 2009, 80, 054301:1-054301:4.
    • (2009) Rev. Sci. Instrum , vol.80
    • Stuban, N.1    Niwayama, M.2
  • 6
    • 0024523226 scopus 로고
    • Principles of pulse oximetry: Theoretical and practical considerations
    • Alexander, C.M.; Teller, L.E.; Gross, J.B. Principles of pulse oximetry: Theoretical and practical considerations. Anesth. Analg. 1989, 68, 368-376.
    • (1989) Anesth. Analg , vol.68 , pp. 368-376
    • Alexander, C.M.1    Teller, L.E.2    Gross, J.B.3
  • 7
    • 12344251727 scopus 로고    scopus 로고
    • A primer on radiometry
    • Kirkpatrick, S.J. A primer on radiometry. Dent. Mater. 2005, 21, 21-26.
    • (2005) Dent. Mater , vol.21 , pp. 21-26
    • Kirkpatrick, S.J.1
  • 8
    • 0025551790 scopus 로고
    • A review of the optical properties of biological tissues
    • Cheong, W.F.; Prahl, S.A.; Welch, A.J. A review of the optical properties of biological tissues. IEEE J. Quantum Electron. 1990, 26, 2166-2185.
    • (1990) IEEE J. Quantum Electron , vol.26 , pp. 2166-2185
    • Cheong, W.F.1    Prahl, S.A.2    Welch, A.J.3
  • 9
    • 0027447714 scopus 로고
    • Measurement of the optical properties of the skull in the wavelength range 650-950 nm
    • Firbank, M.; Hiraoka, M.; Essenpreis, M.; Delpy, D.T. Measurement of the optical properties of the skull in the wavelength range 650-950 nm. Phys. Med. Biol. 1993, 38, 503-510.
    • (1993) Phys. Med. Biol , vol.38 , pp. 503-510
    • Firbank, M.1    Hiraoka, M.2    Essenpreis, M.3    Delpy, D.T.4
  • 10
    • 23044449569 scopus 로고    scopus 로고
    • Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm
    • doi: 10.1088/0022-3727/38/15/004
    • Bashkatov, A.N.; Genina, E.A.; Kochubey, V.I.; Tuchin, V.V. Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm. J. Phys. D Appl. Phys. 2005, doi: 10.1088/0022-3727/38/15/004.
    • (2005) J. Phys. D Appl. Phys
    • Bashkatov, A.N.1    Genina, E.A.2    Kochubey, V.I.3    Tuchin, V.V.4
  • 11
    • 33749831497 scopus 로고    scopus 로고
    • Optical properties of human cranial bone in the spectral range from 800 to 2000 nm
    • doi: 10.1117/12.697305
    • Bashkatov, A.N.; Genina, E.A.; Kochubey, V.I.; Tuchin, V.V. Optical properties of human cranial bone in the spectral range from 800 to 2000 nm. Proc. SPIE 2006, doi: 10.1117/12.697305.
    • (2006) Proc. SPIE
    • Bashkatov, A.N.1    Genina, E.A.2    Kochubey, V.I.3    Tuchin, V.V.4
  • 14
    • 0032714683 scopus 로고    scopus 로고
    • Optical properties of circulating human blood in the wavelength range 400-2500 nm
    • Roggan, A.; Friebel, M.; Dörschel, K.; Hahn, A.; Müller, G. Optical properties of circulating human blood in the wavelength range 400-2500 nm. J. Biomed. Opt. 1999, 4, 36-46.
    • (1999) J. Biomed. Opt , vol.4 , pp. 36-46
    • Roggan, A.1    Friebel, M.2    Dörschel, K.3    Hahn, A.4    Müller, G.5
  • 16
    • 0031076227 scopus 로고    scopus 로고
    • A new family of sensors for pulse oximetry
    • Siegfrid, K.; Friedemann, N. A new family of sensors for pulse oximetry. Hewlett-Packard J. 1997, 48, 1-17.
    • (1997) Hewlett-Packard J , vol.48 , pp. 1-17
    • Siegfrid, K.1    Friedemann, N.2
  • 17
    • 0032226241 scopus 로고    scopus 로고
    • A near-infrared muscle oximeter that can correct the influence of a subcutaneous fat layer
    • Yamamoto, K.; Niwayama, M.; Lin, L.; Shiga, T.; Kudo, N.; Takahashi, M. A near-infrared muscle oximeter that can correct the influence of a subcutaneous fat layer. Proc. SPIE 1998, 3257, 146-155.
    • (1998) Proc. SPIE , vol.3257 , pp. 146-155
    • Yamamoto, K.1    Niwayama, M.2    Lin, L.3    Shiga, T.4    Kudo, N.5    Takahashi, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.