메뉴 건너뛰기




Volumn 13, Issue 4, 2014, Pages 29-40

Diagnostic accuracy of chest ultrasonography versus chest radiography for identification of pneumothorax: A systematic review and meta-analysis

Author keywords

Diagnostic tests; Pneumothorax; Radiography; Routine; Ultrasonography

Indexed keywords

ARTICLE; DIAGNOSTIC ACCURACY; ECHOGRAPHY; EMERGENCY PHYSICIAN; GOLD STANDARD; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; META ANALYSIS; PNEUMOTHORAX; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; SYSTEMATIC REVIEW; THORAX RADIOGRAPHY;

EID: 84925010286     PISSN: 17350344     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (125)

References (63)
  • 2
    • 84865580177 scopus 로고    scopus 로고
    • Deaths: Leading causes for 2008
    • Heron M. Deaths: leading causes for 2008. Natl Vital Stat Rep 2012; 60 (6): 1- 94.
    • (2012) Natl Vital Stat Rep , vol.60 , Issue.6 , pp. 1-94
    • Heron, M.1
  • 3
    • 84899896626 scopus 로고    scopus 로고
    • Positron emission tomography in the follow-up of cutaneous malignant melanoma patients: A systematic review
    • Danielsen M, Højgaard L, Kjær A, Fischer BM. Positron emission tomography in the follow-up of cutaneous malignant melanoma patients: a systematic review. Am J Nucl Med Mol Imaging 2013; 4 (1): 17- 28.
    • (2013) Am J Nucl Med Mol Imaging , vol.4 , Issue.1 , pp. 17-28
    • Danielsen, M.1    Højgaard, L.2    Kjær, A.3    Fischer, B.M.4
  • 5
    • 84907022007 scopus 로고    scopus 로고
    • Accuracy of Ultrasonography in Confirmation of Adequate Reduction of Distal Radius Fractures
    • Esmailian M, Zargarbashi EH, Masoumi B, Karami M. Accuracy of Ultrasonography in Confirmation of Adequate Reduction of Distal Radius Fractures. Emergency 2013;1(1):7- 10.
    • (2013) Emergency , vol.1 , Issue.1 , pp. 7-10
    • Esmailian, M.1    Zargarbashi, E.H.2    Masoumi, B.3    Karami, M.4
  • 6
    • 77949401345 scopus 로고    scopus 로고
    • Medical imaging in the 21st century--getting the best bang for the rad
    • Brenner DJ. Medical imaging in the 21st century--getting the best bang for the rad. N Engl J Med 2010; 362 (10): 943- 5.
    • (2010) N Engl J Med , vol.362 , Issue.10 , pp. 943-945
    • Brenner, D.J.1
  • 7
    • 78649519120 scopus 로고    scopus 로고
    • Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007
    • Lee J, Kirschner J, Pawa S, Wiener DE, Newman DH, Shah K. Computed tomography use in the adult emergency department of an academic urban hospital from 2001 to 2007. Ann Emerg Med 2010; 56 (6): 591- 6.
    • (2010) Ann Emerg Med , vol.56 , Issue.6 , pp. 591-596
    • Lee, J.1    Kirschner, J.2    Pawa, S.3    Wiener, D.E.4    Newman, D.H.5    Shah, K.6
  • 8
    • 70349091037 scopus 로고    scopus 로고
    • Clinical prediction rules for identifying adults at very low risk for intra-abdominal injuries after blunt trauma
    • Holmes JF, Wisner DH, McGahan JP, Mower WR, Kuppermann N. Clinical prediction rules for identifying adults at very low risk for intra-abdominal injuries after blunt trauma. Ann Emerg Med 2009; 54 (4): 575- 84.
    • (2009) Ann Emerg Med , vol.54 , Issue.4 , pp. 575-584
    • Holmes, J.F.1    Wisner, D.H.2    McGahan, J.P.3    Mower, W.R.4    Kuppermann, N.5
  • 9
    • 75449109863 scopus 로고    scopus 로고
    • Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma
    • Wilkerson RG, Stone MB. Sensitivity of bedside ultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma. Acad Emerg Med 2010; 17 (1): 11- 7.
    • (2010) Acad Emerg Med , vol.17 , Issue.1 , pp. 11-17
    • Wilkerson, R.G.1    Stone, M.B.2
  • 11
    • 33646059166 scopus 로고    scopus 로고
    • A pilot study to derive clinical variables for selective chest radiography in blunt trauma patients
    • Rodriguez RM, Hendey GW, Marek G, Dery RA, Bjoring A. A pilot study to derive clinical variables for selective chest radiography in blunt trauma patients. Ann Emerg Med 2006; 47 (5): 415- 8.
    • (2006) Ann Emerg Med , vol.47 , Issue.5 , pp. 415-418
    • Rodriguez, R.M.1    Hendey, G.W.2    Marek, G.3    Dery, R.A.4    Bjoring, A.5
  • 12
    • 27844508573 scopus 로고    scopus 로고
    • Old fashion clinical judgment in the era of protocols: Is mandatory chest X-ray necessary in injured patients?
    • discussion 330-2
    • Sears BW, Luchette FA, Esposito TJ, Dickson EL, Grant M, Santaniello JM, et al. Old fashion clinical judgment in the era of protocols: is mandatory chest X-ray necessary in injured patients? J Trauma 2005; 59 (2): 324- 30; discussion 330-2.
    • (2005) J Trauma , vol.59 , Issue.2 , pp. 324-330
    • Sears, B.W.1    Luchette, F.A.2    Esposito, T.J.3    Dickson, E.L.4    Grant, M.5    Santaniello, J.M.6
  • 13
    • 84886411247 scopus 로고    scopus 로고
    • NEXUS chest: Validation of a decision instrument for selective chest imaging in blunt trauma
    • Rodriguez RM, Anglin D, Langdorf MI, Baumann BM, Hendey GW, Bradley RN, et al. NEXUS chest: validation of a decision instrument for selective chest imaging in blunt trauma. JAMA Surg 2013; 148 (10): 940- 6.
    • (2013) JAMA Surg , vol.148 , Issue.10 , pp. 940-946
    • Rodriguez, R.M.1    Anglin, D.2    Langdorf, M.I.3    Baumann, B.M.4    Hendey, G.W.5    Bradley, R.N.6
  • 15
    • 0037382387 scopus 로고    scopus 로고
    • Blunt abdominal trauma: Should US be used to detect both free fluid and organ injuries?
    • Poletti PA, Kinkel K, Vermeulen B, Irmay F, Unger PF, Terrier F. Blunt abdominal trauma: should US be used to detect both free fluid and organ injuries? Radiology 2003; 227 (1): 95- 103.
    • (2003) Radiology , vol.227 , Issue.1 , pp. 95-103
    • Poletti, P.A.1    Kinkel, K.2    Vermeulen, B.3    Irmay, F.4    Unger, P.F.5    Terrier, F.6
  • 16
    • 84924959680 scopus 로고    scopus 로고
    • Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation
    • Ojaghi Haghighi SH, Morteza Begi HR, Sorkhabi R, et al. Diagnostic Accuracy of Ultrasound in Detection of Traumatic Lens Dislocation. Emergency 2014;2(3):121-4.
    • (2014) Emergency , vol.2 , Issue.3 , pp. 121-124
    • Ojaghi Haghighi, S.H.1    Morteza Begi, H.R.2    Sorkhabi, R.3
  • 17
    • 84925006761 scopus 로고    scopus 로고
    • Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma
    • Heydari F, Esmailian M, Dehghanniri M. Diagnostic Accuracy of Ultrasonography in the Initial Evaluation of Patients with Penetrating Chest Trauma. Emergency 2014; 2(2): 81- 4.
    • (2014) Emergency , vol.2 , Issue.2 , pp. 81-84
    • Heydari, F.1    Esmailian, M.2    Dehghanniri, M.3
  • 20
    • 84888273125 scopus 로고    scopus 로고
    • The FAST and EFAST in 2013: Trauma ultrasonography: Overview, practical techniques, controversies, and new frontiers
    • Williams SR, Perera P, Gharahbaghian L. The FAST and EFAST in 2013: trauma ultrasonography: overview, practical techniques, controversies, and new frontiers. Crit Care Clin 2014; 30 (1): 119- 50, vi.
    • (2014) Crit Care Clin , vol.30 , Issue.1
    • Williams, S.R.1    Perera, P.2    Gharahbaghian, L.3
  • 21
    • 84903618707 scopus 로고    scopus 로고
    • Point-of-care ultrasound in aerospace medicine: Known and potential applications
    • Wagner MS, Garcia K, Martin DS. Point-of-care ultrasound in aerospace medicine: known and potential applications. Aviat Space Environ Med 2014; 85 (7): 730- 9.
    • (2014) Aviat Space Environ Med , vol.85 , Issue.7 , pp. 730-739
    • Wagner, M.S.1    Garcia, K.2    Martin, D.S.3
  • 22
    • 84902202099 scopus 로고    scopus 로고
    • Point-of-care lung ultrasound
    • Volpicelli G. Point-of-care lung ultrasound. Praxis (Bern 1994) 2014; 103 (12): 711-6.
    • (2014) Praxis (Bern 1994) , vol.103 , Issue.12 , pp. 711-716
    • Volpicelli, G.1
  • 23
    • 84896319081 scopus 로고    scopus 로고
    • Bedside pleural procedures by pulmonologists and nonpulmonologists: A 3-year safety audit
    • See KC, Ong V, Teoh CM, Ooi OC, Widjaja LS, Mujumdar S, et al. Bedside pleural procedures by pulmonologists and nonpulmonologists: a 3-year safety audit. Respirology 2014; 19 (3): 396- 402.
    • (2014) Respirology , vol.19 , Issue.3 , pp. 396-402
    • See, K.C.1    Ong, V.2    Teoh, C.M.3    Ooi, O.C.4    Widjaja, L.S.5    Mujumdar, S.6
  • 24
    • 85027928270 scopus 로고    scopus 로고
    • Bedside Lung Ultrasonography: A Tool for Rapid Assessment of Pneumothorax
    • Barbara DW. Bedside Lung Ultrasonography: A Tool for Rapid Assessment of Pneumothorax. Anesthesiology 2014.
    • (2014) Anesthesiology
    • Barbara, D.W.1
  • 25
    • 84903152802 scopus 로고    scopus 로고
    • Double-lung point sign in traumatic pneumothorax
    • Aspler A, Pivetta E, Stone MB. Double-lung point sign in traumatic pneumothorax. Am J Emerg Med 2014; 32 (7): 819. e1-2.
    • (2014) Am J Emerg Med , vol.32 , Issue.7
    • Aspler, A.1    Pivetta, E.2    Stone, M.B.3
  • 27
    • 84892983979 scopus 로고    scopus 로고
    • Elimination of pneumothorax and hemothorax during placement of implantable venous access ports using ultrasound and fluoroscopic guidance
    • Fankhauser GT, Fowl RJ, Stone WM, Money SR. Elimination of pneumothorax and hemothorax during placement of implantable venous access ports using ultrasound and fluoroscopic guidance. Vascular 2013.
    • (2013) Vascular
    • Fankhauser, G.T.1    Fowl, R.J.2    Stone, W.M.3    Money, S.R.4
  • 28
    • 84862654702 scopus 로고    scopus 로고
    • A portable thoracic closed drainage instrument for hemopneumothorax
    • Tang H, Pan T, Qin X, Xue L, Wu B, Zhao X, et al. A portable thoracic closed drainage instrument for hemopneumothorax. J Trauma Acute Care Surg 2012; 72 (3): 671- 5.
    • (2012) J Trauma Acute Care Surg , vol.72 , Issue.3 , pp. 671-675
    • Tang, H.1    Pan, T.2    Qin, X.3    Xue, L.4    Wu, B.5    Zhao, X.6
  • 29
    • 80053489172 scopus 로고    scopus 로고
    • Diagnosis of pneumothorax by radiography and ultrasonography: A metaanalysis
    • Ding W, Shen Y, Yang J, He X, Zhang M. Diagnosis of pneumothorax by radiography and ultrasonography: a metaanalysis. Chest 2011; 140 (4): 859- 66.
    • (2011) Chest , vol.140 , Issue.4 , pp. 859-866
    • Ding, W.1    Shen, Y.2    Yang, J.3    He, X.4    Zhang, M.5
  • 30
    • 84884392087 scopus 로고    scopus 로고
    • Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: Review of the literature and meta-analysis
    • Alrajab S, Youssef AM, Akkus NI, Caldito G. Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis. Crit Care 2013; 17 (5): R208.
    • (2013) Crit Care , vol.17 , Issue.5
    • Alrajab, S.1    Youssef, A.M.2    Akkus, N.I.3    Caldito, G.4
  • 31
    • 84857942235 scopus 로고    scopus 로고
    • Test characteristics of ultrasonography for the detection of pneumothorax: A systematic review and meta-analysis
    • Alrajhi K, Woo MY, Vaillancourt C. Test characteristics of ultrasonography for the detection of pneumothorax: a systematic review and meta-analysis. Chest 2012; 141 (3): 703- 8.
    • (2012) Chest , vol.141 , Issue.3 , pp. 703-708
    • Alrajhi, K.1    Woo, M.Y.2    Vaillancourt, C.3
  • 32
    • 0034685429 scopus 로고    scopus 로고
    • Meta-analysis of observational studies in epidemiology: A proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group
    • Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: a proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group. JAMA 2000; 283 (15): 2008- 12.
    • (2000) JAMA , vol.283 , Issue.15 , pp. 2008-2012
    • Stroup, D.F.1    Berlin, J.A.2    Morton, S.C.3    Olkin, I.4    Williamson, G.D.5    Rennie, D.6
  • 34
    • 0034183318 scopus 로고    scopus 로고
    • A simple method for obtaining original data from published graphs and plots
    • Sistrom CL, Mergo PJ. A simple method for obtaining original data from published graphs and plots. AJR Am J Roentgenol 2000; 174 (5): 1241- 4.
    • (2000) AJR Am J Roentgenol , vol.174 , Issue.5 , pp. 1241-1244
    • Sistrom, C.L.1    Mergo, P.J.2
  • 35
    • 0041876133 scopus 로고    scopus 로고
    • Measuring inconsistency in meta-analyses
    • Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. BMJ 2003; 327 (7414): 557- 60.
    • (2003) BMJ , vol.327 , Issue.7414 , pp. 557-560
    • Higgins, J.P.1    Thompson, S.G.2    Deeks, J.J.3    Altman, D.G.4
  • 36
    • 23644432857 scopus 로고    scopus 로고
    • The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed
    • Deeks JJ, Macaskill P, Irwig L. The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol 2005; 58 (9): 882- 93.
    • (2005) J Clin Epidemiol , vol.58 , Issue.9 , pp. 882-893
    • Deeks, J.J.1    McAskill, P.2    Irwig, L.3
  • 38
    • 0032937034 scopus 로고    scopus 로고
    • The comettail artifact: An ultrasound sign ruling out pneumothorax
    • Lichtenstein D, Mezière G, Biderman P, Gepner A. The comettail artifact: an ultrasound sign ruling out pneumothorax. Intensive Care Med 1999; 25 (4): 383- 8.
    • (1999) Intensive Care Med , vol.25 , Issue.4 , pp. 383-388
    • Lichtenstein, D.1    Mezière, G.2    Biderman, P.3    Gepner, A.4
  • 39
    • 0036787306 scopus 로고    scopus 로고
    • Traumatic pneumothorax detection with thoracic US: Correlation with chest radiography and CT--initial experience
    • Rowan KR, Kirkpatrick AW, Liu D, Forkheim KE, Mayo JR, Nicolaou S. Traumatic pneumothorax detection with thoracic US: correlation with chest radiography and CT--initial experience. Radiology 2002; 225 (1): 210- 4.
    • (2002) Radiology , vol.225 , Issue.1 , pp. 210-214
    • Rowan, K.R.1    Kirkpatrick, A.W.2    Liu, D.3    Forkheim, K.E.4    Mayo, J.R.5    Nicolaou, S.6
  • 40
    • 4444313942 scopus 로고    scopus 로고
    • Hand-held thoracic sonography for detecting posttraumatic pneumothoraces: The Extended Focused Assessment with Sonography for Trauma (EFAST)
    • Kirkpatrick AW, Sirois M, Laupland KB, Liu D, Rowan K, Ball CG, et al. Hand-held thoracic sonography for detecting posttraumatic pneumothoraces: the Extended Focused Assessment with Sonography for Trauma (EFAST). J Trauma 2004; 57 (2): 288- 95.
    • (2004) J Trauma , vol.57 , Issue.2 , pp. 288-295
    • Kirkpatrick, A.W.1    Sirois, M.2    Laupland, K.B.3    Liu, D.4    Rowan, K.5    Ball, C.G.6
  • 41
    • 23944521630 scopus 로고    scopus 로고
    • A prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax
    • Blaivas M, Lyon M, Duggal S. A prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax. Acad Emerg Med 2005; 12 (9): 844- 9.
    • (2005) Acad Emerg Med , vol.12 , Issue.9 , pp. 844-849
    • Blaivas, M.1    Lyon, M.2    Duggal, S.3
  • 42
    • 22844441654 scopus 로고    scopus 로고
    • Value of high-resolution ultrasound in detecting a pneumothorax
    • Chung MJ, Goo JM, Im JG, Cho JM, Cho SB, Kim SJ. Value of high-resolution ultrasound in detecting a pneumothorax. Eur Radiol 2005; 15 (5): 930- 5.
    • (2005) Eur Radiol , vol.15 , Issue.5 , pp. 930-935
    • Chung, M.J.1    Goo, J.M.2    Im, J.G.3    Cho, J.M.4    Cho, S.B.5    Kim, S.J.6
  • 43
    • 14644417785 scopus 로고    scopus 로고
    • Accuracy of transthoracic sonography in excluding post-interventional pneumothorax and hydropneumothorax. Comparison to chest radiography
    • Reissig A, Kroegel C. Accuracy of transthoracic sonography in excluding post-interventional pneumothorax and hydropneumothorax. Comparison to chest radiography. Eur J Radiol 2005; 53 (3): 463- 70.
    • (2005) Eur J Radiol , vol.53 , Issue.3 , pp. 463-470
    • Reissig, A.1    Kroegel, C.2
  • 47
    • 34447641451 scopus 로고    scopus 로고
    • Rapid detection of pneumothorax by ultrasonography in patients with multiple trauma
    • Zhang M, Liu ZH, Yang JX, Gan JX, Xu SW, You XD, et al. Rapid detection of pneumothorax by ultrasonography in patients with multiple trauma. Crit Care 2006; 10 (4): R112.
    • (2006) Crit Care , vol.10 , Issue.4
    • Zhang, M.1    Liu, Z.H.2    Yang, J.X.3    Gan, J.X.4    Xu, S.W.5    You, X.D.6
  • 48
    • 38349076400 scopus 로고    scopus 로고
    • Occult traumatic pneumothorax: Diagnostic accuracy of lung ultrasonography in the emergency department
    • Soldati G, Testa A, Sher S, Pignataro G, La Sala M, Silveri NG. Occult traumatic pneumothorax: diagnostic accuracy of lung ultrasonography in the emergency department. Chest 2008; 133 (1): 204-11.
    • (2008) Chest , vol.133 , Issue.1 , pp. 204-211
    • Soldati, G.1    Testa, A.2    Sher, S.3    Pignataro, G.4    La Sala, M.5    Silveri, N.G.6
  • 49
    • 66449114697 scopus 로고    scopus 로고
    • Sonographic detection of pneumothorax by radiology residents as part of extended focused assessment with sonography for trauma
    • Brook OR, Beck-Razi N, Abadi S, Filatov J, Ilivitzki A, Litmanovich D, et al. Sonographic detection of pneumothorax by radiology residents as part of extended focused assessment with sonography for trauma. J Ultrasound Med 2009; 28 (6): 749- 55.
    • (2009) J Ultrasound Med , vol.28 , Issue.6 , pp. 749-755
    • Brook, O.R.1    Beck-Razi, N.2    Abadi, S.3    Filatov, J.4    Ilivitzki, A.5    Litmanovich, D.6
  • 50
    • 84924972238 scopus 로고    scopus 로고
    • Evaluation Of The Accuracy Of Bedside Ultrasonography In The Diagnosis Of Pneumothorax In Suspicious Cases Admitted In Hazrate-Rasool Akram Hospital During 2008
    • [In Persian]
    • Mashayekhian M, Abbasi S, Farsi D, et al. Evaluation Of The Accuracy Of Bedside Ultrasonography In The Diagnosis Of Pneumothorax In Suspicious Cases Admitted In Hazrate-Rasool Akram Hospital During 2008. Razi J Med Sci. 2010;17(77):67-73. [In Persian].
    • (2010) Razi J Med Sci. , vol.17 , Issue.77 , pp. 67-73
    • Mashayekhian, M.1    Abbasi, S.2    Farsi, D.3
  • 51
    • 79958278514 scopus 로고    scopus 로고
    • Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan
    • Nagarsheth K, Kurek S. Ultrasound detection of pneumothorax compared with chest X-ray and computed tomography scan. Am Surg 2011; 77 (4): 480- 4.
    • (2011) Am Surg , vol.77 , Issue.4 , pp. 480-484
    • Nagarsheth, K.1    Kurek, S.2
  • 52
    • 79953698494 scopus 로고    scopus 로고
    • Extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax: Experience at a community based level I trauma center
    • Nandipati KC, Allamaneni S, Kakarla R, Wong A, Richards N, Satterfield J, et al. Extended focused assessment with sonography for trauma (EFAST) in the diagnosis of pneumothorax: experience at a community based level I trauma center. Injury 2011; 42 (5): 511- 4.
    • (2011) Injury , vol.42 , Issue.5 , pp. 511-514
    • Nandipati, K.C.1    Allamaneni, S.2    Kakarla, R.3    Wong, A.4    Richards, N.5    Satterfield, J.6
  • 53
    • 84858005073 scopus 로고    scopus 로고
    • Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?
    • Donmez H, Tokmak TT, Yildirim A, Buyukoglan H, Ozturk M, Yaşar Ayaz U, et al. Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma? J Clin Ultrasound 2012; 40 (3): 142- 6.
    • (2012) J Clin Ultrasound , vol.40 , Issue.3 , pp. 142-146
    • Donmez, H.1    Tokmak, T.T.2    Yildirim, A.3    Buyukoglan, H.4    Ozturk, M.5    Yaşar Ayaz, U.6
  • 54
    • 84860564601 scopus 로고    scopus 로고
    • Diagnostic accuracy of ultrasonography in the acute assessment of common thoracic lesions after trauma
    • Hyacinthe AC, Broux C, Francony G, Genty C, Bouzat P, Jacquot C, et al. Diagnostic accuracy of ultrasonography in the acute assessment of common thoracic lesions after trauma. Chest 2012; 141 (5): 1177- 83.
    • (2012) Chest , vol.141 , Issue.5 , pp. 1177-1183
    • Hyacinthe, A.C.1    Broux, C.2    Francony, G.3    Genty, C.4    Bouzat, P.5    Jacquot, C.6
  • 55
    • 84877063994 scopus 로고    scopus 로고
    • Accuracy of emergency physician-performed ultrasound in detecting traumatic pneumothorax after a 2-h training course
    • Abbasi S, Farsi D, Hafezimoghadam P, Fathi M, Zare MA. Accuracy of emergency physician-performed ultrasound in detecting traumatic pneumothorax after a 2-h training course. Eur J Emerg Med 2013; 20 (3): 173- 7.
    • (2013) Eur J Emerg Med , vol.20 , Issue.3 , pp. 173-177
    • Abbasi, S.1    Farsi, D.2    Hafezimoghadam, P.3    Fathi, M.4    Zare, M.A.5
  • 56
    • 84879504263 scopus 로고    scopus 로고
    • Value of ultrasound in diagnosis of pneumothorax: A prospective study
    • Jalli R, Sefidbakht S, Jafari SH. Value of ultrasound in diagnosis of pneumothorax: a prospective study. Emerg Radiol 2013; 20 (2): 131- 4.
    • (2013) Emerg Radiol , vol.20 , Issue.2 , pp. 131-134
    • Jalli, R.1    Sefidbakht, S.2    Jafari, S.H.3
  • 57
    • 84925016104 scopus 로고    scopus 로고
    • Evaluation of the accuracy of portable ultrasound (eFAST) for detection of pneumothorax
    • [in persian]
    • Karimi E, Safari S, Shekarchi B. Evaluation of the accuracy of portable ultrasound (eFAST) for detection of pneumothorax. J Army Univ Med Sci. 2013;11(3):225-30. [in persian].
    • (2013) J Army Univ Med Sci. , vol.11 , Issue.3 , pp. 225-230
    • Karimi, E.1    Safari, S.2    Shekarchi, B.3
  • 58
    • 84879110498 scopus 로고    scopus 로고
    • Clinician-performed Beside Ultrasound for the Diagnosis of Traumatic Pneumothorax
    • Ku BS, Fields JM, Carr B, Everett WW, Gracias VH, Dean AJ. Clinician-performed Beside Ultrasound for the Diagnosis of Traumatic Pneumothorax. West J Emerg Med 2013; 14 (2): 103- 8.
    • (2013) West J Emerg Med , vol.14 , Issue.2 , pp. 103-108
    • Ku, B.S.1    Fields, J.M.2    Carr, B.3    Everett, W.W.4    Gracias, V.H.5    Dean, A.J.6
  • 59
    • 84878943174 scopus 로고    scopus 로고
    • Bedside sonography for detection of postprocedure pneumothorax
    • Shostak E, Brylka D, Krepp J, Pua B, Sanders A. Bedside sonography for detection of postprocedure pneumothorax. J Ultrasound Med 2013; 32 (6): 1003- 9.
    • (2013) J Ultrasound Med , vol.32 , Issue.6 , pp. 1003-1009
    • Shostak, E.1    Brylka, D.2    Krepp, J.3    Pua, B.4    Sanders, A.5
  • 60
    • 84880088769 scopus 로고    scopus 로고
    • Impact of the practice of "Extended Focused Assessment with Sonography for Trauma" (e-FAST) on clinical decision in the emergency department
    • Uz I, Yürüktümen A, Boydak B, Bayraktaroğlu S, Ozçete E, Cevrim O, et al. Impact of the practice of "Extended Focused Assessment with Sonography for Trauma" (e-FAST) on clinical decision in the emergency department. Ulus Travma Acil Cerrahi Derg 2013; 19 (4): 327- 32.
    • (2013) Ulus Travma Acil Cerrahi Derg , vol.19 , Issue.4 , pp. 327-332
    • Uz, I.1    Yürüktümen, A.2    Boydak, B.3    Bayraktaroğlu, S.4    Ozçete, E.5    Cevrim, O.6
  • 61
    • 84922061242 scopus 로고    scopus 로고
    • First-line sonographic diagnosis of pneumothorax in major trauma: Accuracy of e-FAST and comparison with multidetector computed tomography
    • Ianniello S, Di Giacomo V, Sessa B, Miele V. First-line sonographic diagnosis of pneumothorax in major trauma: accuracy of e-FAST and comparison with multidetector computed tomography. Radiol Med 2014; 119 (9): 674- 80.
    • (2014) Radiol Med , vol.119 , Issue.9 , pp. 674-680
    • Ianniello, S.1    Di Giacomo, V.2    Sessa, B.3    Miele, V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.